| 1 | L1₹15.8 LAccepted-AOC YOL CAMP TEH DHARAMSHALA DISTT KANGRA HP | YOL | KANGRA | HIMACHAL PRADESH | 176052 | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.0 L+₹2.3 L (14.3%)Rejected-Finance SHIVAJI NIWAS VILL CHIMBALHAR P O GEETA PEETH PALAMPUR HP 176061 | KANGRA | HIMACHAL PRADESH | 176061 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹18.5 L+₹2.8 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹18.7 L+₹3.0 L (18.8%)Rejected-Finance | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹20.6 L+₹4.8 L (30.6%)Rejected-Finance | L5 | Rejected-Finance Other Than L1 |
Tender Value
₹22.5 L
EMD Value
₹45,000
Closing Date
10 Nov 2021, 6:00 pmClosed
GE(KH)YOL
GE(KH)YOL
PROVN OF SINGLE RAMP APPROACH ROAD INCLUDING PLATFORM AND 01X SENTRY POST IN MT AREA UNDER AGE BR-I AT YOL CANTT
2021_MES_481955_1
GE/Y-44/2021-22
Open Tender
Civil Works
Item Rate
183 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(KH)YOL
₹45,000
Yes
4 Feb 2022
14 Oct 2021
17 Nov 2021
14 Oct 2021
10 Nov 2021
28 Oct 2021
Amount
PART:-Surface excavation not exceeding 30 cms deep and averaging 15cms deep and getting out in any type of soil, complete all as specified.
Add to (or deduct from) above for every 3 cm or part thereof above or below 15 cm average depthand getting out in any type of soil, complete all as specified.
Excavation in trenches n exc 1.5 metre wide & n exc 1.5 metre in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n. exc 10 Sqm on plan n exc 1.5 metre in depth and getting out in any type of soil, complete all as specified.
Excavating over area as, n exc 1.5 m deep and getting out in depth and getting out in any type of soil, complete all as specified.
Plain cement concrete M-7.5 nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete, complete, all as specified.
Fly ash brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified.
Hard core of broken stone or boulders of gauge not exc. 63mm deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for roughly finished flat surfaces of concrete, all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), etc. For roughly finished flat surfaces of concrete, all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, for roughly finished flat surfaces of concrete, all as specified.
Reinforced cement concrete (design mix) M-25 ( using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified.
Reinforced cement concrete (design mix) M-25 ( using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, all as specified.
TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , all as specified.
TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
TMT bars 6mm dia and over up to 10mm, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers and binders, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) on fair faces of brick wall or concrete surfaces, surface finished even and smooth without using extra cement with WPC , all as specified. Note :- water proofing compound shall be measured and paid separately
Rendering plaster 15mm thick in cement mortar 1:6 (1 cement :6 coarse sand) on fair faces of brick wall or stone wall surfaces, surface finished even and smooth without using extra cement, all as specified.
Three coats of white wash on newly plastered or previously undecorated surfaces of walls including preparation of surfaces complete, all as specified.
Steel windows with side hung shutters including projecting typehinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or weldedall as specified.
Applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel or steel based surfaces of any description, exceeding 10cm width or girth including preparation of surfaces, all as specified.
Three coats of white wash on newly plastered or previously undecorated surfaces of ceiling including preparation of surfaces complete, all as specified.
Sand filling under floors or in foundations including watering and consolidations, all as specified.
Plain cement concrete M-15, nominal mix, type B-1, using 20mm graded mechanically crushed stone aggregate as in floors, 40mm thick, surface finished even and fair to receive top surface, all as specified.
Rolling and consolidating formation surfaces with 8 to 12 tonne power roller complete all as specified and as directed.
150mm spread thickness soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and cambercomplete , all as specified and as directed.
100mm thick Plain cement concrete M-7.5 nominal mix, D-2, using 40mm graded mechanically crushed stone aggregate as in sub base complete all as specified.
Finishing surface of concrete roads, pavements, by floter and brooming complete, all as specified.
Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, laid to required level, gradient and camber including necessary form work complete alll specified and directed . Thickness of concrete 25 cm or less complete, all as specified and as directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, Thickness of concrete slab in 150mm complete .all as specified.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete, all as specified.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A'all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment laid over and including 50mm thick sand cushion, joints of tiles filled with dry sand and compacted with mechanical vibrator complete all as specified and directed.
Plain cement concrete M-10, nominal mix, C-1 using 20mm graded mechanically crushed stone aggregate as in lintels upto 1.5 metre clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, chamfered angles and throating, complete all as directed Note :- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Mild steel galvanized iron water tubing 25mm bore with screwed & socket joints, medium grade, in short lengths, with and including all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. laid in trenches complete, all as specified and directed.
Gun metal, globe or gate valves , screwed down, high pressure with crutch or butterfly handle, screwed both ends for 25mm bore iron pipe or for unions and fixed complete, all as specified.
Drilling and tapping GI water mains (in position for branch connection of internal bore 25mm) including provision of clamps, nutsbolt, furrle all as specified all as specified.
Part-II:-Supply , installation and testing of centrifugal monoblock water pump of capacity 1HP, 0.75kW, 240 V of frequency 50Hz energy efficient motor 2900 RPM with maximum working pressure 3.8Kg/cmsquare IP-54 protection , high suction with self priming up to 7.5m , high grade pump castings FG-200 grade with stainless steel shaft SS-410 pump set suitable for pipe 25mm bore, of head range 14-28 metre of discharege capacity 6560-2520 lph, including control panel for capacity 0.75KW 1HP monoblock pump of capacitto run 50µF capacitor start (mfd) 120/150 µF complete all as specified and directed by Engg-In-Charge. Make :- KIRLOSKAR, WASP, ITT, BEACON, MATHER &PLATT, RANDFOS, KSB
1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 4sqmm, complete all as specified.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multi strand) PVC insulated ISI Marked unsheathed cable in and including concealed PVC conduits, medium grade, ISI marked not less than 25 mm dia and conforming to IS-9537 (Part-II) 1983 with all fittings/ accessories and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire connected to common earth dolly and including pressed steel/ cast iron of suitable sizes terminal boxes made from 1.60 mm thick sheet for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one bell point, independent, controlled by one way switch/ push button complete all as specified and directed. Note:-i) Wiring colour code i.e Red/Yellow/Blue for phase , Black for neutral and Green for earth shall be maintained. ii) The wire from switch board to ceiling rose shall be of 2x1.5Sqmm +1x1.5sqmm rates for the same shall deemed to be included in item .
All as per Srl item No. '41' hereinbefore but for 3 pin 15 amps socket out let on independent with 2.5 Sqmm PVC copper conductor cable and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5/6 Amps, all as specified.
Switch socket combination 5 Pin, 5 Amp & 15 Amp flush type controlled by one switch, all as specified.
Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral ,2 way, 240 volts with 200 Amp rated bus bar, all as specified. , all as specified.
Sheet metal enclosures factory made for DBs when MCBs to be used, single pole and neutral (double Door), 4 way, 240 volts with 200 Amp rated bus bar, all as specified.
MCB SP 6 to 40 Amp, 240 Volts, 10 KA all as specified. Note:-The connection to the MCBs shall be through thimble/lugs for and rate for the same shall deemed to be included in quoted rates
MCB SPN 40 Amp, 240 Volts, 10 KA all as specified. Note:-The connection to the MCBs shall be through thimble/lugs for and rate for the same shall deemed to be included in quoted rates
Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver all in one fxture, 18 watt LED and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete , all as specified.
Energy saving, environmental friendly, 50 watt leds long life, exclusive innovative die-cast aluminium with IP66 protection and impact resistance of IK07 flood light, and including connecting up with three core twisted flexible copper conductor cable with suitable size, all as specified. including connecting up with twin core twisted flexible copper conductor cable with suitable size, including GI bracket of suitable size with clamps all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 2core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
Sand cushioning to under ground cables, 8 cm thick layer before laying and testing the cable and 15 cm thick after laying and testing of the cable in trenches complete all as specified in Clause 19.75 of MES SSR 2009 Part-I and directed by Engr-in-Charge.
Sub class 'B' bricks old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Mild steel galvanised light grade 40mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. For roughly finished flat surfaces of concrete, all as specified.
Reinforced cement concrete (design mix) M-25 ( using 20mm graded crushed stone aggregate) as in beams, cantilevers, lintel, over 1.50m span all as specified.
MM Constructions
M/S RANA BUILDERS
VIJAY KUMAR LAKHNI
m/s Sohan singh barwal and Brothers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .