Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹18.5 L+₹1.3 L (7.84%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹18.6 L+₹1.5 L (8.55%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹21.3 L+₹4.2 L (24.4%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹20.4 L
EMD Value
₹40,740
Closing Date
17 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND MAINT OF VARIOUS TYPES OF FAN, DESERT COOLERS AND PETTY ITEMS ETC CONNECTED TO E M NATURE OF WORKS IN THE DIFFERENT BLDG OF OTM MD ACCN AT RALAWAS UNDER GE BANAR
2022_MES_514351_2
8821/37/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Banar
₹40,740
Yes
18 Jun 2022
26 Apr 2022
19 May 2022
26 Apr 2022
17 May 2022
3 May 2022
60 days
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by EIC.
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including PVC casing caping (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point controlled by one switch, complete all as specified for the following:- (a) One light / fan point controlled by one, one-way switch, SP, 6 Amps.
One socket outlet, 3 pin, 5 Amp, 230 volt flush type on same board.
One switch socket outlet, 3 pin, 5 Amp, 230 volt flush type on independent board.
One bell/buzzar point controlled by one bell push independent
All as per item No.2 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed.
M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CONDUIT and conduit accessories,confirming to IS specifications,concealed in wall fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed for :-(a) One light / fan point controlled by one, one-way switch, SP, 6 Amps.
One socket outlet, 3 pin, 5 Amp, 230 volt flush type on same board.
One switch socket outlet, 3 pin, 5 Amp, 230 volt flush type on independent board.
One bell/buzzar point controlled by one bell push independent
Ditto all as per item No.4 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed.
Supply and fix switch piano, flush type, single pole, one way, 5 Amps 230 Volts ISI Marked. complete all as specified and directed by EIC.
Supply and fix in repair switch piano, flush type, single pole, one way, 5 Amps 230 Volts ISI Marked. complete all as specified and directed by EIC.
Supply and fix switch piano, flush type, single pole, one way 15 Amps 230 Volts ISI Marked complete all as specified and directed by EIC.
Supply and fix socket outlet 2-in-1, 3 pin, 5 Amps, flush type with shutter, ISI Marked complete all as specified and directed by EIC.
Supply and fix in repair socket outlet 2-in-1, 3 pin, 5 Amps, flush type with shutter, ISI Marked complete all as specified and directed by EIC.
Supply and fix in repair of socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, ISI Marked complete all as specified and directed by EIC.
Supply and fix switch socket combination 2-in-1, 3 pin, 5 Amps, flush type with shutter, ISI Marked complete all as specified and directed by EIC.
Supply and fix in repair switch socket combination 2-in-1, 3 pin, 5 Amps, flush type with shutter, ISI Marked complete all as specified and directed by EIC.
Supply and fix switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, ISI Marked complete all as specified and directed by EIC.
Supply and fix in repair switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, ISI Marked complete all as specified and directed by EIC.
Supply and fix electronic regulator, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd.
Supply and fix in repair electronic regulator, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd.
Supply and fix ceiling rose, surface bakelite, three terminals all as specified and as directed by EIC.
Supply and fix in repair of ceiling rose, surface bakelite, three terminals all as specified and as directed by EIC.
Supply and fix Lamp Holder PVC/polycarbonate type with back plate ISI Marked for fixing bulbs complete all as directed by EIC for batten fitting
Supply and fix in repair Lamp Holder PVC/polycarbonate type with back plate ISI Marked for fixing bulbs complete all as directed by EIC for batten fitting
Supply and fix in repair Pin Top 15 Amp ISI Marked complete all as directed by EIC.
Supply and fix buzzer, ding dong AC 230 Volt, Single pole (ISI Marked) all as specified and as directed by EIC.
Supply and fix in repair buzzer, ding dong AC 230 Volt, Single pole (ISI Marked) all as specified and as directed by EIC.
Supply and fix in repair Bell multi Musical type AC 230 Volt, Single pole (ISI Marked) all as specified and as directed by EIC.
Supply and fix in repair Bell push, AC 230 Volt, Single pole (ISI Marked) all as specified and as directed by EIC.
Supply and fix in repair SPN DB's, 12 way, 240 V, double door 200 amps rated bus bar, complete all as specified and as directed., (a) 12 way
All as per item No 27.00 but 8 way.
All as per item No 27.00 but 4 way
Supply and fix in repair 4 way TPN DB, 415 V, double door 200 amps rated bus bar, complete all as specified and as directed by EIC.
Supply and fix in repair 4 way VTPN DB, 415 V, double door 200 amps rated bus bar, including 100 Amps 4 pole, 16 KA MCCB, complete all as specified and as directed by EIC.
Supply and fix in repairs MCB SPN 32 Amps 240 volts as per directed by Engr-in-Charge
Supply and fix in repair MCCB 4 Pole 125 Amps 415 volts. 18kA Adjustableoverload setting l &fixed magnetic setting
Supply and fix in repairs MCB SP 6 Amps to 32 Amps 230 Volt complete.
Fixing only any type light fitting, surface/recess mounting type serviceable one complete all as directed.Note :- Material issued shall be under sch 'B'
M&L Sub main wiring with 2 run of single core FRLS PVC insulated and unsheathed multistranded, FRLS copper conductor size 6 sqmm cable 1100 volts grade and one run of 6 sqmm as earth wire drawn through and incl 20 mm size of of PVC conduit including accessories and fittings on wall. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. Note:- 02 runs of cable & one run of earth shall be measured as one unit.
All as per item No 34.00 but 02 runs 4 sqmm conductor cable and 01 run of 4 sqmm as earth continuity conductor.
All as per item No 34.00 but 02 runs 2.5 sqmm conductor cable and 01 run of 2.5 sqmm as earth continuity conductor.
Supply and fix in repair condenser 240 volts 2.5 MFD, Heavy duty incl testing.
Supply and fix in repair condenser 240 volts 4 MFD, Heavy duty incl testing.
Supply and fix in repair Modular metal flush box with white cover plate with frame of 3 module for mounting, switches, sockets, fan regulator, etc. Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items.
All as per item No 37.00 but 6 module
All as per item No 37.00 but 8 module cover only
As per item No 37.00 but 12 module
Supply and fix in repair switch modular 5/6 Amp single pole, one way 1 module as specified.
Supply and fix in repair switch modular 15/16 Amp single pole, one way 1 module as specified.
Supply and fix in repair Bell push modular 6 Amp single pole, one way 1 module as specified.
Supply and fix in repair Fan Regulator modular 120W single pole, one way 2 module as specified.
Supply and fix in repair Socket modular 5/6 Amp single pole, 2/3 pin 2 module as specified.
Supply and fix in repair Socket modular 15/16 Amp single pole, 2/3 pin 2 module as specified.
Supplyand fix in repair Switch socket outlet modular multipurpose 3 Pin 16 Amp and one pin 6 Amp controlled by one switch as specified and directed by EIC
Supply and fix in repair Switch socket outlet modular multipurpose 3 Pin 6 Amp flush type controlled by one switch as specified.
Inspection,checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refix the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Spare part shall be measured and paid seprately.
Taking down geysers of any type and any capacity and re-installation at any location including S&F in repair of heavy duty pin type fastener 4” long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed.
Supply only heating elements of capacity 1.50 KW.
All as per item No 48.00 but capacity 2.00 KW
Supply only thermostat cutout suitable for 1.5/2.00 KW geyser.
Supply only Stainless steel connection pipe 15mm bore,heavy duty suitable for 1.50/2.00 KW geyser.
Supply and fix in and replacement of glass wool for geysers complete all as specified.
S&F in replacement base assembly, compatible to existing gyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified.
S&F in replacement Multifuction /Non return valve ISI marked of capacity 15mm/20mm dia connecting up complete all as directed.
S&F in replacement Bronze fusible plug of capacity 25/50 litrs.
S&F in replacement indicator lamp set with wire kit for geyser of any type colour green & red complete all as specified.
S&F in replacement stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed.
S&F in replacement of stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed.
S&F in replacement outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enameled paints complete all as specified and as directed.
S&F in replacement outer body of MS sheet not less than 20 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 50 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified and as directed.
M&L for painting of outer surface of 25/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
S&F in repairs Metal Clad Plug and socket with box 20 Amp with MCB single pole complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm as per specification as per dirteced
Re-routing of existing sub main wiring any size with and including new 20 mm PVC Conduit and prepare the existing surface in good condition all as directed .
Re-routing of existing sub main wiring any size with and including new 32 mm PVC Conduit and prepare the existing surface in good condition all as directed .
Re-routing of existing sub main wiring any size with and including new 20 mm PVC casing capping and prepare the existing surface in good condition all as directed .
Re-routing of existing sub main wiring any size with and including new 25 mm PVC cassing capping and prepare the existing surface in good condition all as directed .
Supply and fixing in repair PVC casing capping 20 mm size on existing sub main wiring/point wiring any size and prepare the existing surface in good condition all as directed .
Supply and fixing in repair PVC cassing capping 25 mm size on existing sub main wiring/point wiring any size and prepare the existing surface in good condition all as directed .
Supply and fixing in repair PVC flexible pipe 20 mm size on existing sub main wiring/point wiring/ any place and prepare the existing surface in good condition all as directed .
Supply and fixing in repair PVC Conduit pipe 25 mm size on existing sub main wiring/point wiring/ any place and prepare the existing surface in good condition all as directed .
Supply and fix in repair LED Decorative wall light fixture with 9W retrofit LED lamp amade up of integral polycarbonate type wall mounted 230 V complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete.
M&L Cutting chasing in bricks/walls or concrete surfaces for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep complete all as specified and directed by Engr-in-Charge
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175mmx100mmx50mm deep complete all as specified and directed by Engr-in-Charge
M&L for replacement PVC rectangular block for mounting switches,sockets,fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mmx200mmx50mm deep complete all as specified and directed by Engr-in-Charge
Material and labour for painting to old steel surfaces of Desert cooler of Air flow capacity up to 5000 Cu M/hr with two coats of synthetic enamel spray paint hammer tone paint of approved colour make ICI paint (Dulax closs), asian paint (Apcolite), Jenson & Nicholson,over one coat of red oxide on external surface and two coats of anti corrosive black paint inside the Body tank and side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES No in 25mm height etc complete all as specified and directed by Engineer-in-Charge at site
M&L for replacement of copper conductor cable 40/0.75 Sqmm 3 core 3 to 5 m long with plug top 5 Amp inbuilt suitable for desert cooler.
M&L for Replacement of PVC water distributor with PVC pipe and PVC pipe elbow complete for desert cooler upto 5000 CFM all as directed by EIC.
M&L for replacement of Fan blade of desert cooler heavy duty HDPE suitable for 4000/5000 CFT cap complete all as directed by EIC.
M&L for replacement of Water lifting submersible pump of head 1.2 m approx suitable for desert cooler as per existing capacity.
M&L for Taking down desert cooler fan motor and supply and fixing new desert cooler fan motor with outer ring and nut-bolts for desert cooler upto 5000 CFM copper wounded, three speed approved make complete all as directed by EIC.
M&L for Taking down u/s desert cooler motor, cutting of burnt out winding and rewinding super enamelled copper conductor fixing of desert cooler motor to existing location complete all as specified and directed by Engr-in-Charge. make all as directed by EIC. Note:- Contractor will produce Guarantee letter for the rewinding of the motor minimum 1 year from the date of installarion and testing.
Supply & Fix in repairs wood wool Pad (set of three), minimum weight 0.80 kg, inside panels of desert coolers complete all as directed by EIC.
Supply & Fix in repairs capacitor 4 MFD for fan motors of desert cooler.
M&L for Replacement of rusted and leakaged body part (Water tank of Desert cooler) 4000/ 5000 CUM/hr capacity as required at site with existing gauge of sheet :-
As item No. 88.00 but herein Side lags
As item No. 80 but herein Top cover
As item No. 80 but herein Front grill with connection strip
As item No. 80 but herein Supporting legs with frame and clips incl nuts & bolts of desert cooler.
M&L for taking down fan of any type/make and size carefully from fan hook, dismantling of blades and transporting from any location in side army area to MES E/M store yard for washing throughly of bearing/bush by petrol , washing and cleaning the fan blades , body , canopy etc throughly , provision of new greasing , replacement of worn out/ defective unserviceable parts including fan rod (wherever necessary ) reassembling the same and testing the fan on full load to entire satisfaction of Engr-in-Charge Note:- (i) Replacement of defective / unserviceable parts will be paid separately under relevent items of this schedule(ii) The cost for labour to taking out and refixing the new material is deemed to be inclusive of quoted rates. (iii) Any type of petty items which are not included in this schedule will deemed to be inclusive of quoted rates.
M&L for Hanging carefully ceiling fan in hook and make connection with exsiting point wiring including provision of three core (FRLS)cable not less than 0.75 sqmm of size from ceiling rose or connector to ceiling fan complete all as directed by Engr-in-Charge. Note:- Any petty items like nut bolts washers & safety pin etc required for hanging deemed to be inclusive of quoted rates.
M&L for Removing rusts/dusts cleaning thoroughly with petrol to the ceiling fan in situ and spray painting with one coat to ceiling fan of any size and type with 1st quality synthetic enamel paint as per exsisting colour to fan body, down rod/ canopy etc and writing the MES number as MES/NT-(No) on the fan body in black paint all as directed by Engineer-in-Charge.
M&L for taking down burnt out ceiling fan of any type and size , dismantling the fan blades ,opening the cover to Cutting the existing copper winding and rewinding the armature (Rotor) with super enamelled copper wire of suitable gauge incl all insulating materials complete and re-assembling the fan, fan blades and hanging in fan hook to the same location by providing three core copper (FRLS) cable not less than 0.75 sqmm from ceiling rose or connector to fan and satisfactory testing on full speed to entire satisfaction of Engineer-in-Charge.Note:- (i) Contractor will produce guarntee letter for rewinding of fan minimum 1 year from the date of installation and testing (ii) The cost of transportation will deemed to be inclusive of quoted rates.(iii) Cost of labour for taking down and refixing will deemed to be inclusive of quoted rates.(iv) Any petty items required for fixing will deemed to be inclusive of quoted rates.
Supply andfix in repair PVC Junction box with cover 25mm as per site requirement complete
M&L for Turning of fan shaft after re-metalling and welding including cutting threading welding and the materials for exhaust fans of any size and Make.
M&L for Filling (Metalling) the worn out shaft at bush/ball bearing seat by welding and machining for proper fixing of ball bearing/bush of any size of ceiling fan complete all as specified and directed by Engr-in-Charge.
S&F in repair of fan blades set of ceiling fan for any sweep of the existing make all as directed by Engineer-in-Charge.
S&F in repair of plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws all as directed by Engineer-in-Charge.
S&F in repair rubber reels incl shackle clamp, bolts, nuts, washers split pins of appropriate size as required at site all as directed by Engr-in-charge.
S& F in repair ball bearing of suitable to ceiling fan including testing complete all as specified and directed by Engr-in-charge.Make:- SKF/NBC/SBBI
S&F in repair bush bearing made out Gun metal suitable for ceiling fan complete all as directed and specified by Engr-in-charge.
M&L for down rod of 15mm dia GI pipe heavy duty 45 cm long incl machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable to any type and sweep size of fan.
M&L for Dismantling of wall mounting Air circulating fan size 600mm sweep of any make for washing thoroughly of bearing/bush by petrol / cleaning of fan blades and body etc ,greasing and oiling complete, re-fixing the same to existing location after painting with synthetic enamel paint of approved make with spray gun of one coat as per exsisting colour , connecting and testing on full speed to entire satisfaction of Engineer-in-Charge. Note:- (i) Defective / unserviceable parts will be paid separately as supply only under relevent items of this schedule(ii) The cost of labour to taking out and refixing the new material is deemed to be inclusive of quoted rates. (iii) Any type of petty items which are not included in this schedule will deemed to be inclusive of quoted rates. of size
All as per Item No 106.00 but 380-450 mm sweep any make
Supply and fix in repair 3mm thick Plastic laminated sheet cover suitable for switch board as per site requirement as directed by Engr-in-Charge
M&L for taking down the burnt out wall mounting air ciculator fan size 600mm sweep of any make and dismantal the blades ,opening the cover to cutting the existing copper winding and rewinding the armature (Rotor) with super enamelled copper wire of suitable gauge incl all insulating materials varnishing and heating complete and refixing at same location after painting to entire body of wall mounting fan with synthetic enamel paint as per exsisting colour by using spray gun incl satisfactory testing on full speed complete all as directed by Engineer-in-Charge of the following sizes Note:-(i) Cost of items except rewinding will be measured and paid separately under relevent items of this schedule (ii) Quoted rate is deemed to be inclusive of transporting and taking down unserviceable/defective parts.of size.
All as per Ser Item No 108.00 but 400-450 mm sweep any make
Supply and fix LED Post top light fiiting 15W, 230V 50hz landscape luminaire with high power LED long life aesthetically designed with symmetrical light distribution with IP-65 230 V complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete.Make:- Havells RUBYMINIPT15WLED757PSYMTOPC or eqivalant.
Supply of condenser of 240 volts ,10 MFD suitable for wall mounting air circulating fan 600 mm incl testing.
Supply of condenser 240 volts 8 MFD suitable for wall mounting air circulating fan 450 mm incl testing.
Supply of Condenser 240 volts 6 MFD suitable for wall mounting air circulating fan 400 mm incl testing.
Supply of ball bearing of size suitable for 600 mm sweep Air circulating fan incl testing.
Supply of ball bearing of size suitable for 450/400 mm sweep Air circulating fan incl testing.
S&F in repair of damaged/defective MS fan blades for 600 mm sweep Air Circulator fan complete all as specified and directed by Engr-in-Charge.
S&F in repair of damaged/defective MS fan blades as per existing for 450/400 mm sweep Air Circulator fan complete all as specified and directed by Engr-in-Charge.
M&L for taking down exhaust fan size 450mm sweep of any make carefully from site & transporting from any location inside Army area to MES E/M store yard for stripping of fan washing thoroughly of bearing/bush by petrol, washing fan blade body etc thoroughly provision of new greasing replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same incl connection by providing three core copper (FRLS) cable not less than 0.75 Sqmm from ceiling rose to fan and testing on full speed to entire satisfaction and fixing at original location complete all as directed. Note :- 1. Replacement of parts/rewinding shall be measured and paid separately. 2. Quoted rate is deemed to be inclusive of transporting and taking down unserviceable/defective parts.
All as per item No 117.00 but 380 mm sweep any make
All as per item No 117.00 but 300 mm sweep any make
M&L for Rewinding the armature of exhaust fan size 450mm sweep of any make with super enamelled copper wire of suitable for incl all insulating materials varnishing complete incl satisfactory test run on full speed complete.
All as per item No 118.00 but 380 mm sweep any make
All as per item No 118.00 but 300 mm sweep any make
S&F ball bearing of size suitable for 300 to 450 mm exhaust fan incl testing and refixing complete.
S&F bush bearing made out Gun metal of size suitable for 450 to 300 mm of exhaust fan incl testing and refixing complete.
M&L for Replacement of supporting legs with frame and clips incl nuts & bolts of size suitable for 380 mm sweep size exhaust fan.
M&L for Replacement of supporting legs with frame and clips incl nuts & bolts of size suitable for 300 mm sweep size exhaust fan.
M&L for Replacement of MS fan blades assembly for 450 mm sweep exhaust fan.
M&L for Replacement of MS fan blades assembly for 380 mm sweep exhaust fan.
M&L for Replacement of MS fan blades assembly for 300 mm sweep exhaust fan.
S&F in repairs exhaust fan louvers suitable to any sweep including making necessary arrangement like ladder/scaff holding etc and drilling of hole for fitting of exhaust fan louvre complete all as directed by Engineer-in-Charge.
Supply and fix in repair PVC TV Socket 5 Amps 230 Volts ISI Marked. complete all as specified and directed by EIC.
S&F in repair PVC insulated copper conductor multicore FRLS 2 core 10 sqmm for 1100V conforming to IS-694:2010 complete all specification and directed by Engr-in-Charge
Shri Electrical Enterprises
Narendra General Suppliers
DIWAKAR CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .