Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹38.9 L+₹1.5 L (3.96%)Rejected-Finance H 45 MAHESH NAGAR AMBALA CANTT 133001 HARYANA | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹42.4 L+₹4.9 L (13.2%)Rejected-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹43.9 L+₹6.4 L (17.1%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹44.0 L+₹6.6 L (17.6%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-56(P)/2020-21 PROVN OF CERTAIN SANCTIONED WORKS IN SECTOR A UNDER AGE B/R-II OF GE (NORTH) AMBALA CANTT
2020_MES_367827_1
GE(N)Amb-56(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹94,000
Yes
25 Jan 2021
9 Dec 2020
16 Jan 2021
9 Dec 2020
14 Jan 2021
31 Dec 2020
9 Dec 2020 - 31 Dec 2020
60 days
Amount
Schedule 'A' part-I ie B/R items
Demolition of Cement concrete (un-reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L for providing precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), kerb stone, string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and set in CM 1:4 complete with joints to match complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting exc 10 cm and n. exc 20 cm girth complete all as specified and as directed by the Engineer-in-Charge.
S & F sinks with drainage board made out of stainless steel 1mm thick sheet for kitchen or laboratory with plugs, waste pipe, brass chromium plated coupling and wastes; in-cluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connect-ing union to pipe overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge
S&F kitchen plate rack of stainless steel sheet 1mm thickness size 900mm x 750mm x250mm and having weight not less than 8.00 Kg each complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing including one shop coat of zinc chromate primer conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutters of any description area exc 1 sq. m and not exc 2 sq. m each complete all as specified and as directed by the Engineer-in-Charge
M&L factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
M&L factory made 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area n. exc 1.5 Sqm each and refixing in same opening complete all as specified and as directed by the Engineer-in-Charge
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel butt hinges 100 mm long medium weight old rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel sliding door bolt plate type 300 mm long stove enamelled black with bright bolt not less 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge
Supply only mild steel butt hinges 50 mm long medium weight old rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by engineer in charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately. complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium window side hung type without sash bars complete including chowkats made out of hollow aluminium section of size 100 x 44 x 1.6 mm and shutter frame made out of hollow aluminium section of size 100 x 44 x 1.6 mm including neccessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as aluminium tower bolts 150mm long (2 Nos.), hinges type B-21 100 mm long (2 Nos.), 100 mm long aluminium handle (1 No.) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing anodised aluminium grill of approved pattern to aluminium frame complete all as specified and as directed by the Engineer-in-Charge.
S & F steel windows or ventilators, fixed type,fabricated from heavy 'Z' steel section with glazing bars complete all as specified and as directed by the Engineer-in-Charge
S&F stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with tinned tack or stainless steel wire staple ,complete all as specified and as directed by the Engineer-in-Charge
M & L sheet glass 4.0mm thick, ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F in repair stainless steel wire cloths 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staple complete all as specified and as directed by the Engineer-in-Charge
Hacking out old broken glass (any thickness,size,quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge
M & L sheet glass 4.0mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
M&L for TMT steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT steel bars 5 mm dia upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M&L glazed ceramic coloured tiles 1st quality in vertical surfaces/skirtings/dados of size 350x250x7mm/450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut baroda Green marble stone slab 18 to 20 mm thick in kitchen cooking platform and jointed in grey cement slurrry mixed with pigment to match the shade of the slab incl cutting, rubbing and polishing over and including 20 mm thick cement screed bed in CM 1:6 and half rounding the edges of stone slab (stone slab shall fixed in one piece upto lenght of 1.80 metre and in two piece in case the lenght of cooking plateform is more than 1.80 metre) complete all as specified and as directed by the Engineer-in-Charge.
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L 10 mm thick cement plaster on brick or concrete ceiling surfaces in CM 1:3, finished even and smooth with out using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L 15 mm thick cement plaster on fair faces of brick or concrete walls in CM 1:6, finished even and smooth with out using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on other than fair faces of brick work or concrete wall surfaces in cement mortar 1:4 and including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces of wall and applying three coats white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new wooden surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new steel and iron surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of existing treatment on walls to remove any loose/unsound material,dirt, dust etc with mechanical means i.e. wire brush and air blower as required, brooming down , scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil and greasy spots and applying two coat of oil bound distemper on surfaces of walls, pillars, cornices etc complete all as specified and as directed by the Engineer-in-Charge.
S & F fancy type bib tap 15mm bore cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F 15mm bore cast copper alloy chromium plated stop valves, fancy type with long shank and cup (concealed type), screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and as directed by the Engineer-in-Charge
S & F PVC connections 60 cm long with PTMT nuts at both ends complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
M & L taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge
M & L taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge
S & F galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, including cast iron 'S' trap 100 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair 32 mm bore Low density polyethylene pipes (LDPE)of pressure rating 6kgf/cm2 in standard length suitable for WHB and sink complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) bends of any radius complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S&F 110mm bore PVC (SWR) junction single (Single T) equal or unequal etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 110mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
M & L PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge
S & F 500 litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge Note:- Tank shall be in white colour.
S & F 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
S & F of fixing GI OREO Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge. GI Metal Ceiling laying perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and applying neat cement slurry @3 Kg/Sqm complete all as specified and as directed by the Engineer-in-Charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position (framed work) complete all as specified and as directed by the Engineer-in-Charge.
M&L 2nd class Sal/Hallock hard wood in scantling (framed work) clean sawn complete all as specified and as directed by the Engineer-in-Charge.
M & L carring out roof treatment consisting of following:- 1. Cleaning of old concrete roof surface by roughening, picking, sweeping, cleaning and washing down with water to remove dust etc, 2. Brushing neat cement slurry with 3.0 kg of cement per sq. metre. 3. Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centigrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centigrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge.
S&F powder coated aluminium door made out of hollow extructed aluminium section of size 101.60 x 44.45 x 1.55 mm for chowkhat, 85 x 44.45 x 1.56 mm for vertical style of shutter, 83.5 x 44.45 x 1.54 mm for middle rail of shutter , 85 x 44.45 x 1.54 mm for top rail of shutter and 150 x 44.45 x 1.54 mm for bottom rail of shutter including neccessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as aluminium tower bolts 200 mm long (2 Nos.), hinges type B-21, 125 mm long (4 Nos.), 150 mm long aluminium handle D or disk type (2 Nos.) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 100 mm size brass mortice lock, vertical type, 6 levers with dublicate key complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, govering pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 12 mm thickness prelaminated particale board,exterior grade, prelaminated both side with decorative choice lamination and fixed to aluminium door with glazing clips, rubber etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 5.5 mm thick tinted glass to aluminium door with glazing clips, rubber etc complete all as specified and as directed by the Engineer-in-Charge.
Excavating in post holes (or similar holes) in hard /dense soil each not exceeding 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm ,watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 Type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Surface dressing not exceeding 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge exc 63mm and n exc 100mm , deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:2:4 Type B-2 using 40mm graded crushed stone aggregate as in floor/ hard standing etc and finished even and fair without using extra cement and making impressions of expennded metal, whilst the concrete is green complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:3:6 Type C-2 using 40mm graded crushed stone aggregate as in floor etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material exc 250m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1 :3 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' part-II ie E/M items
Supply and fix sheet metal enclosure for MCB DBs 12 way with 200 Amps rated bus bar single pole and neutral with one transparent acrylic main door IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps 2 Pole, 2 module 30 ma (HI immunity) sensitivity 230 volts 50 Hz with degree of protection IP 20, rated conditional short circuit ICC 10 KA complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over voltage release 230 V, single phase in one module suitable for 1Ph+N complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing indoor decorative 1 x 18/20 watt LED tube light fitting Batten type with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 18/20 W LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, T5 with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED flat panel 2' x 2' size fully difused surface/ recess mounted fitting (grid/ gypsum type) 33-36 watt , 5700K, warm/cool white with powder coating and CRCA front cover including frame with provision of PVC flexible copper conductor cable to light fitting complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 3.06 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 3.06 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6/16 amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6-40 amps 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole & netural , 240 volt, 32 amps 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply & fix modular bell push, 6 Amp, flush type, 230 volts complete all as specified and as directed by the Engr-in-charge.
Supply & fix call bell ding dong, 230 V, single pole , complete all as specified and as directed by the Engr-in-charge.
Supply & fix modular fan regulator, 2 module , electronic rotary type, 120 watt,230volts,50 Hz, AC supply suitable for celling fan any type/make/sweep complete all as specified and as directed by Engineer-in-Charge.
Supply & fix TV socket modular 2/3 pin 5 Amp, 1 way, 2 modular, 230 volts complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal enclosure for MCB DBs 8 way with 200 Amps rated bus bar single pole and neutral with one transparent acrylic main door IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection complete all as specified and as directed by the Engineer-in-Charge.
dhingra builders
Durga Enterprises
Karishan Kumar goel
singh traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .