Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAdmitted-Finance | ₹43.7 L | L1 | Admitted-Finance |
| 2 | L2₹49.0 LAdmitted-Finance | ₹49.0 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | K J JOSE L2 | Anoop Anand L1 |
|---|---|---|---|---|---|
| 1.00CIVIL WORKS EARTHWORK | |||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil and including shoring etc complete as directed , within a lead of 50 m.All kinds of soil. | 77.5 | Cum | 200 ₹15,501 | 390 ₹30,226.95 |
| 1.02 | 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. | 65.88 | Cum | 200 ₹13,175 | 350 ₹23,056.25 |
| 1.03 | 50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge | 19.74 | Cum | 700 ₹13,817.30 | 800 ₹15,791.20 |
| 1.04 | Providing and applying Anti-termite treatment by injecting chemical emulsion Imidacloprid 30.5%SC at a concentration 5 litres per sqm or as per manufacturers recommendation for preconstruction treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineerin-Charge. (Plinth area only to be measured for the payment ). | 92.55 | Sqm | 200 ₹18,510.60 | 150 ₹13,882.95 |
| 1.05 | 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). | 16.9 | Sqm | 7,500 ₹1.3 L | 750 ₹12,672 |
| 1.06 | 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. | 16.9 | Sqm | 200 ₹3,379.20 | 250 ₹4,224 |
| 2.00PCC WORKS | |||||
| 2.01 | 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 12.05 | Cum | 7,500 ₹90,390 | 9,000 ₹1.1 L |
| 3.00RCC WORK | |||||
Tender Value
₹43.1 L
EMD Value
₹50,000
Closing Date
19 Jan 2026, 3:00 pmClosed
Managing Director, INKEL Limited
1st Floor, Ajiyal Complex, Post Office Road, Kakkanad - 682030
Civil, Plumbing and Electrical Works
2026_INKEL_826655_1
NIT/INKEL/NHM/2025-26/353 dated 09/01/2026
Open Tender
Civil Works - Buildings
270 days
Thirunelloor
As per Tender Document
12 documents required · 12 mandatory
₹2,950
₹50,000
Yes
11 Feb 2026
9 Jan 2026
21 Jan 2026
10 Jan 2026
19 Jan 2026
12 Jan 2026
CIVIL WORKS EARTHWORK
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil and including shoring etc complete as directed , within a lead of 50 m.All kinds of soil.
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
Providing and applying Anti-termite treatment by injecting chemical emulsion Imidacloprid 30.5%SC at a concentration 5 litres per sqm or as per manufacturers recommendation for preconstruction treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineerin-Charge. (Plinth area only to be measured for the payment ).
4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
PCC WORKS
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
RCC WORK
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All work up to plinth level. Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of cantering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.(Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design) All work above plinth level up to floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3 Centering and shuttering including strutting, etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform
5.9.5 Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6 Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.19 Centering and shuttering including strutting, etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges
Steel reinforcement work
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Block Work
50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.1.5 Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.2.2 Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Joinery works
21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade II Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc.complete as per architectural drawings and directions of Engineer - in- Charge. Prelaminated particle board with decorative lamination on both sides.
Providing and fixing pin headed glass in Aluminium door, window, ventilator shutters and etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of Aluminium snap beading shall be paid in basic item): glass of 4.0 mm thickness partitions.
21.3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
21.3.2 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
9.84 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing roller for shutters of sliding aluminium windows with necessary screws etc.complete as approved by Engineer-in-charge
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) locking arrangement for sliding windows including necessary screws and fittings of approved make as directed by Engineer-in-charge.
9.121 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
9.122.1 Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire -retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
9.97.1 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
9.97.2 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm
9.100.1 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
9.100.2 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm
9.108.2 Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms
9.106.2 Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms
9.101.1 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern
Supplying and fixing 100mm mortice cylinder lock for aluminium door with following specification. a)Hook bolt has to be made of MS and SS for end plate and strike plate with lock set of size minimum 37mm, back set of min 20mm and hock bolt of min 18mm. b)Cylinder should be made of brass with minimum weight 0.20kg with nickel plated brass key (3 sets) and it should be of 5pin brass tumbler mechanism
50.9.15.2 Supplying and fixing 300 mm Aluminium aldrop
Steel work
9.48.2 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Flooring and waterproofing works
11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying anti skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.48.2 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
11.46.2 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Terrace waterproofing: Providing and applying water proofing treatment to Terrace with Polymer Modified waterproofing system, Brushbond (Two part) After thorough surface preparation, Sealing for floor cracks, sealing honeycombs and sealing of floor to wall joints and Pressure grouting the leakage areas etc...With non-shrink cement mortar and saturating the surface, and brush applying two coats etc complete as per the direction of engineer in charge etc complete as per the direction of engineer in charge.
22.14.1 Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Finishing works
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
5.23 Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 (1 cement : 3 fine sand).
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.2.1 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)
13.7.2 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 (1 cement : 4 fine sand)
PUBLIC HEALTH ENGINEERING SANITARY FIXTURES, BATH FITTINGS AND ACCESSORIES
17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing sanitary fixtures for handicapped toilet including one number White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, overall size 660 x 375 x 760mm. or as per approved model and shape,including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves, gasket etc.complete, wash basin, one pair mounting brackets, one number elbow operated pillar cock 3.8 LPM @ 3 Bar and all other related fittings likewaste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc., designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.
17.7.4 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
17.7.9 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked
Providing and fixing of Black colour Poly Propylene Laboratory Sink, Dimensions: external 558 x 355 x 240mm, Net weight: 2.7 kg, Temperature range: 0-80°C, 1/2” BSP Waste connection, Net weight: 0.2 kg Dimensions: Ø73, 1½” BSP with PTMT/PP waste coupling, adjustable screw on nut. including cutting and making good the walls wherever required: Polypropylene Laboratory Sink without drain board
Providing and fixing CP Wall Mounted type Sink Tap complete with Wall Flange and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.
18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
50.17.1.5 Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
18.21.2.1 Providing and fixing uplasticised PVC connection pipe with brass unions: 45 cm length15 mm nominal bore
17.28.2.1 Flexible pipe32 mm dia
Providing and fixing of C. P. Robe Hook, 60mm. Dia. x 45mm. High.
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
50.17.1.3 Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-incharge.
INTERNAL DRAINAGE
50.18.8.6.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 110mm OD
Supplying, Installing, Testing and Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye and clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil and Waste pipes -Internal).75mm OD
"Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. U bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. ""U"" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.110mm OD"
"Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts .G.I. ""U"" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. ""U"" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.75mm OD"
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A (IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735)fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps,couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I. "U"bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete. 110mm OD
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost of cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)
Providing and Fixing C.P. brass or stainless steel(SS-304) Square Flat cut single piece Gratings size 125x125 mm. Gratings for 110mm. Floor Traps.
12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
WATER SUPPLY
18.8.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
18.7.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes
18.7.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal dia pipes
18.7.4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal dia pipes
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in charge. Internal work -Exposed on wall - Ceiling and Shaft 32 mm nominal outer dia. Pipes.
18.17.1 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
18.17.2 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore
18.19.2.2 Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal boreVertical
CI Y Strainer 1 1/4” (32mm) dia - Supply, Installation, Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects.
EXTERNAL SEWERAGE AND STORM WATER DRAIN
50.18.9.8.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2
50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 32 mm nominal outer dia Pipes.
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885
19.30.1.1 Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.31.1.1 Extra for depth beyond 45 cm of brick masonry chamber: For 455x610 mm sizeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19.33 Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
51.19.ST1 Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)<br> 1. Below 15 flush capacity
2.10.1.2 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soilPipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
PLUMBING PUMP AND TANK
Supplying, Installation, testing and commissioning of 0.5 HP Single phase Open well submersible pump working at 240V,50 Hz power supply including starter & all accessories suitable for 2.5 Lps at 12 Mtr Head.
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
ELECTRICAL WORKS WIRING
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
DISTRIBUTION BOARDS
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator) 2+12 way, Double door
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
EARTHING
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
METERING
Energy meter Cubicle:Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, wall mounted metering cubicle made out of CRCA sheet complete with hinged and earthed front doors with name plate, heavy duty rubber gaskets, removable gland plates including all accessories required for complete installation as per KSEBL standard. The front door shall be with a vision panel/glass for meter reading and locking arrangement. All opening parts of the panel shall be sealable. The cubicle should have sufficient space to occupy the following devices. 32A DP Isolator - 1 No. 32A Cut out fuse with base - 1 No. Neutral Link 1 No. The cubicle should has space in additional for fixing a 32A 100mA ELCB if required.
LIGHT FIXTURES
19.1 Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
SITC of of LED Tube Lights of 20W(+/- 10% Tolerance) with minimum system lumens 2200 Lumens Extruded Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection inbuilt with electronic drive system, , SDCM<5 and CCT in between 4000K to 5700K,power factor >/=0.95, THD<10%,rated life of 50,000 hours at L70, system efficacy>110 lm/W, with a CRI > 80, or above, Luminaire shall be flicker free with ripple factor < 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same.
SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy>=100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system,power factor >0.95, THD<10%, rated life of 50,000 hours at L70 with a CRI > 80, SDCM<5 and CCT in between 4000K to 5700K, +/-300K. ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same.
Supply and fixing of 5W (+/-10% tolerance) LED Bulb with B22 base, acrylic diffuser.in the Angle batten holder
Supply of exhaust fan of 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C.in the existing opening, including making good the damage, connection, testing, commissioning etc. as required, including all accessories as required for complete installation etc complete as required.
MISCELLANEOUS ITEMS
Supplying, Fixing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Supply and providing First Aid Box
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
BOQ_1386775.xls
BOQ • 0.37 MB
Drwng.pdf
Tender Documents • 0.74 MB
Tenderdoc.pdf
Tender Documents • 0.86 MB
Addnlspec.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid