Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.3 L+₹2.2 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
9 May 2020, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor
REPAIR MAINTENANCE OF SUBMERSIBLE PUMP BOOSTER PUMP STARTERS AND CONNECTED WORKS INCLUDING WATER SUPPLY PIPE LINES AND REPAIR MAINTENANCE OF SUMMER COOLING APPLIANCES AND PAINTING OF CEILING FANS AND CONNECTED WORK AT SUNDERBANI UNDER GE NORTH AKH
2020_MES_338523_1
GE(N)/AKH-02/2020-21
Open Tender
Civil Works
Item Rate
180 days
Sunderbani
E class Cat b i
8 documents required · 8 mandatory
₹500
GE North Akhnoor
₹48,000
Yes
19 Oct 2020
11 Apr 2020
12 May 2020
11 Apr 2020
9 May 2020
27 Apr 2020
Amount
Disconnecting pump, centrifugal type of capacity 15000 GPH at 120m head (coupled with electric moter, 3 phase, 415 volt, 50HP) from motor and pipe fittings both inlet and outlet, taking down from the base plate, dismantling the complete pump for necessary repairs, carring out necessary repairs to pump such as grinding /machining and polishing of serviceable CI impellers, replacement of CI bushes, spacer bushes, pump shaft, neck rings etc. and re-assembling, re-installation, connecting the suction and delivery pipes, testing and commissioning, complete all as specified & directed. Make : MaxFlow Note :- (i) The quoted rates shall be deemed to be included of loading-unloading, transportation of pumpset to approved workshop from Sunderbani to Jammu & back. (ii) Spares shall be measured & paid seperately under relevant items of BOQ as 'Supply only'.
Supply only pump shaft suitable of capacity 15000 GPH at 120m head, coupled with 50 HP motor, fixed in pump, complete all as specified & directed. Make of pump : MaxFlow
Supply only bearing of pump (02 Nos both driving and non-driving end) suitable for pump set of capacity 15000 GPH at 120m head coupled with 50 HP electric motor, complete all as specified & directed. Make: SKF/ NBC
Supply only CI spacer bush suitable for pump set of capacity 15000 GPH at 120m head coupled with 50 HP electric motor, complete all as specified & directed. Make of pump : MaxFlow
Supply only gland packing bush suitable for pump set of capacity 15000 GPH at 120m head coupled with 50 HP electric motor, complete all as specified & directed. Make of pump : MaxFlow.
Disconnecting the electric connections of electric motor 3 phase, 415 volts, 1440 RPM, 50HP Make : Kirloskar, removal of complete stator winding coils, cleaning and making surface for rewinding, rewinding the stator winding of electric motor with super enamelled copper wire of appropriate size with adequate insulating materials, sleeves, varnishing and heating up at required temperature and making electric connections, testing and commissioning complete all as specified & directed. Note: The quoted rates shall be deemed to be included cost of dismantaling, removal of stator/armature from motor, disconnecting the internal electric connections of motor and re-assembling/refitting complete after carrying out necessary repairs.
Disconnecting pump, centrifugal type of capacity 15000 GPH at 30m head (coupled with electric moter, 3 phase, 415 volt, 20 HP) from motor and pipe fittings both inlet and outlet, taking down from the base plate, dismantling the complete pump for necessary repairs, carring out necessary repairs to pump such as grinding /machining and polishing of serviceable CI impellers, replacement of CI bushes, spacer bushes, pump shaft, neck rings etc. and re-assembling, re-installation, connecting the suction and delivery pipes, testing and commissioning, complete all as specified & directed. Make : Kirloskar Note :- (i) The quoted rates shall be deemed to be included of loading-unloading, transportation of pumpset at approved workshop from Sunderbani to Jammu & back. (ii) Spares shall be measured & paid seperately under relevant items of BOQ as 'Supply only'.
Supply only bearing of pump (02 Nos both driving and non-driving end) suitable for pump set of capacity 15000 GPH at 30m head coupled with 20 HP electric motor, complete all as specified & directed. Make: SKF/ NBC
Supply only CI spacer bush suitable for pump set of capacity 15000 GPH at 30m head coupled with 20 HP electric motor, complete all as specified & directed. Make of pump : Kirloskar
Supply only gland packing bush suitable for pump set of capacity 15000 GPH at 30m head coupled with 20 HP electric motor, complete all as specified & directed. Make of pump : Kirloskar
Disconnecting the electric connections of submersible pump set motor of capacity 12.5 HP from auto transformer, starter, removing the delivery pipes, transportation of pumpset to workshop from Sunderbani to Jammu and back & re-fitting/re-connecting the same at site after carrying out necessary repairs/maint of submersible pump-motor as under :- (i) Disconnecting the MS flanged, bends by opening of nuts, bolts of the flanges and clamps from the column pipes and taking out the column pipes from Dugwell. (ii) Lifting out submersible pump set 12.5 HP from dug well after taking out column pipes. (iii) De-coupling the submersible pump & the motor from each other. (iv) Dismantling the pump & motor, carrying out necessary repairs and re-assembling the submersible pump set again after carrying out necessary repairs. (v) Lowering the submersible pump set into dugwell. (vi) Lowering the column pipes by tightning the nuts bolts of the flanges of pipes and connecting the bends complete. (vi) Testing & comissioning complete of submersible pump set after installation at Dugwell. Note :- The items required for repair will be measured and paid separately under relevant items of BOQ.
Repair to submersible motor of capacity 12.5 HP by removal of complete stator winding coils, cleaning and making surface for rewinding, rewinding the stator winding of submersible motor of capacity 12.5 HP with PVC insulated copper wire of appropriate guage with adequate insulating sleeves, grinding and polishing of rotor assembly and replacement of gun metal bushes -02 Nos, replacement of thurst plate bearings set complete and replacement of lower bush housing including grinding of motor casing slots etc making electric connections testing & commissioning complete all as specified & directed.
Dismantling of submersible pump of capacity 12.5 HP Make:KSB/ BS/ Calama for repair and re-assembling the same after carrying out the necessary repairs & replacement of following parts/spares :- (i) Pump shaft - 01 No (ii) CI suction body - 01 No (iii) Gun metal bush - 05 Nos. (iv) GM impellers - 02 Nos. (v) CI driving body - 01 No (vi) MS spacer bush - 05 Nos (vii) CI body -02 Nos (viii) Male and female CI coupling- 01 No
Supply only CI coupling TC-15/TC-16, complete all as specified & directed.
Star delta starter, manually operated, 3 phase, 415 volts suitable for 20HP induction motor including taking down old unserviceable starter, complete all as specified & directed.
Star delta starter, manually operated, 3 phase, 415 volts suitable for 30HP induction motor including taking down old unserviceable starter, complete all as specified & directed.
Star delta starter, manually operated, 3 phase, 415 volts suitable for 75HP induction motor including taking down old unserviceable starter, complete all as specified & directed.
Submersible cable with copper stranded conductor of cross sectional area 10 sqmm 3 core, 1100 volts grade, confirming to relevent IS including testing & taking down old unserviceable cable, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in any type of soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Mild Steel galvanised tube of 15mm bore with screwed socket joints medium grade together with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc and fixed complete to ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, cutting through walls, floors and making good to match with the existing specifications including taking down old unserviceable GI tubing with fittings, complete all as specified & directed.
All as per Srl item No.22 above but bore of mild steel galvanised tube 20mm.
All as per Srl item No.22 above but bore of mild steel galvanised tube 25mm.
All as per Srl item No.22 above but bore of mild steel galvanised tube 40mm.
All as per Srl item No.22 above but bore of mild steel galvanised tube 50mm.
All as per Srl item No.22 above but bore of mild steel galvanised tube 80mm.
All as per Srl item No.22 above but bore of mild steel galvanised tube 100mm.
Run lead joints to spigot and socket pipes (water mains) and pipe fittings of 100mm bore of pipe, complete all as specified & directed.
Run lead joints to spigot and socket pipes (water mains) and pipe fittings of 150mm bore of pipe, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 15mm including taking down old unserviceable gate valve, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm including taking down old unserviceable gate valve, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 25mm including taking down old unserviceable gate valve, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 40mm including taking down old unserviceable gate valve, complete all as specified & directed.
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 50mm including taking down old unserviceable gate valve, complete all as specified & directed.
Reflex (Non return) valve) 100 mm, conforming to IS-5312 with jointing material such as rubber gasket 6 mm thick, nuts, bolts and washers of size 16 mm dia of suitable length including dismantling of old unserviceable valve from existing pipe line, complete all as specified & directed.
Reflex (Non return) valve) 150 mm, conforming to IS-5312 with jointing material such as rubber gasket 6 mm thick, nuts, bolts and washers of size 16 mm dia of suitable length including dismantling of old unserviceable valve from existing pipe line, complete all as specified & directed.
Cast iron sluice valve 100mm with flanged ends drilled with iron wheel with shut and open direction casted to it, class PN-1.6 conforming to IS-14846 with brass spindle including rubber insertion sheet and jointing material such as, nuts, bolts and washers of size 16mm dia of suitable length including dismantling of old unserviceable sluice valve from existing pipe line, complete all as specified & directed.
Cast iron sluice valve 150mm with flanged ends drilled with iron wheel with shut and open direction casted to it, class PN-1.6 conforming to IS-14846 with brass spindle including rubber insertion sheet and jointing material such as, nuts, bolts and washers of size 16mm dia of suitable length including dismantling of old unserviceable sluice valve from existing pipe line, complete all as specified & directed.
Mild steel ERW pipe line of 150mm bore with 15mm thick MS flanged welded on both ends of ERW tube, nuts, bolts washer and packing material (rubber sheet) etc, pipes laid in ground or passing through yards or on pillers including taking down old unserviceable CI/ MS/ GI pipe, complete all as specified & directed . Note : The rate for cutting of road, path, culvert, floor etc for laying of pipeline and making good the damaged surface shall be deemed to be included in the quoted rate.
All as per Srl item No. 40 above but of size 100mm bore.
Brick masonry valve pit of size 1200x1200x1200mm (internal dimension) with earth work in any type of soil, PCC 1:4:8 type D-2 as in foundation, brick work in cement mortar 1:4, 23cm thick, 15mm thick plaster in cement mortar 1:4 internally and externally flush pointed in same mortar as the work proceeds, flooring shall be 40mm thick in PCC 1:2:4 (Nominal mix) type B-2 laid over 75mm thick hard core, top cover shall be made out of MS sheet 16 SWG thickness fixed in angle iron frame made out of angle size 40x40x6mm with 12mm dia handle & two number of hinges on one side and locking arrangement at other side complete including painting with two coats of sythetic enamel paint over a coat of red oxide primer, complete all as specified & as shown on drawing.
Cast iron bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto bore of pipe 150mm, complete all as specified & directed.
Chlorine testing kit complete with test tubes, solution, complete all as specified & directed.
Portalibility test of the water sample (collected at two different water points) from the authorised laboratory and submission of the report, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Cleaning of dugwell having approximately dia 6 Mtrs and depth upto 8 Mtrs by pumping out water/ muddy water by using a non clog pump, cleaning the inner walls by using wire brush, removing waste materials/ mud/ sand and depositing the same 50 Mtrs distance away from the dugwells, complete all as specified & directed. Note : Rates quoted by contractor shall be deemed to be included the dewatering of dugwell, arrangement of pumps and other T&P required for the same.
Cleaning of UG sump/ OH reservior having approximately dia 6 Mtrs and depth upto 4 Mtrs by pumping out or draining out water/ muddy water, cleaning the inner walls by using wire brush, removing chlorine scales from internal walls, waste materials/ mud/ sand and depositing the same 50 Mtrs distance away from the UG sump/OH reservior, complete all as specified & directed. Note : Rates quoted by contractor shall be deemed to be included the dewatering of dugwell, arrangement of pumps and other T&P required for the same.
REPAIR TO VOLTAGE STABLIZERS Disconnecting all electric connections of servo voltage stabilizer of capacity 20 KVA to 150 KVA, 3 phase, 415 Volts from LT panels and transporting it to approved workshop for repairs and back to station, re-install in its original position after making necessary repair including loading and unloading the voltage stabilizer , complete all as specified & directed. Note : The quoted rates shall be deemed to be included of loading-unloading, transportation of stablizer to approved workshop from Sunderbani to Jammu & back.
Drain out old transformer oil & storing in barrels for reuse after dehydration, dismantling of servo voltage stabilizer, taking out voltage stablizer assembly from casing, re-assembling it after carrying out necessary repairs, testing and commissioning the voltage stablizer of capacity 15 KVA to 150 KVA unbalanced type of any make, complete all as specified & directed. Note : Spares shall be measured & paid seperately under relevant items of BOQ.
Sensing/ control card for voltage stablizer of capacity 15 KVA to 150 KVA, complete all as specified & directed.
Servo motor capacity of 10 Kgs, 60 RPH at 240 volts of capacity 15 KVA to 150 KVA, 50 Hz, complete all as specified & directed.
Push buttons as per sample, complete all as specified & directed.
Voltmeter, 0 to 500 volts, square shape 96mm, complete all as specified & directed.
Amp meter, 0 to 300 Amps, square shape 96mm, complete all as specified & directed.
Toggle switch, complete all as specified & directed.
Rewinding of dimmer stat of capacity upto 150 KVA complete with super enamelled copper winding wire and other winding materials including insulating material, varnishing, preheating at heat chamber etc, complete all as specified & directed.
Wiring complete with suitable copper wire of required size or as per sample including accessories for voltage stabilizer of capacity 15 to 150 KVA, complete all as specified & directed.
Rewinding of voltage stablizer of capacity upto 150 KVA complete with super enamelled copper winding wire and other winding materials including insulating material, varnishing, preheating at heat chamber etc, complete all as specified & directed.
Input and output electric connections brass stud of voltage stablizer of capacity 15 KVA to 150 KVA, complete all as specified & directed.
Dehydration of the old transformer oil HV grade by heating process conforming the di-electric strength not less than 70 KV (RMS) with 4 mm gap with high viscosity in transformer as per IS-335 of 1983, filling of the dehydrated transformer oil in the casing/stoarge sump of voltage stablizer after proper cleaning & drying it in heating chamber, complete all as specified & directed.
Transformer oil HV grade having di-electric strength 70 KV (RMS) with 4 mm gap of discharge 2 sec for topping up of transformer as per IS-335 of 1983, complete all as specified & directed.
DESERT COOLER Taking down desert cooler of any type and size from the site, removing all the components such as fans, pumps, wood wool pads, PVC distributor, PVC pipe etc, preparation of surfaces for new paint by scratching old paint from inside and outside complete and refixing the same after necessary repair, complete all as specified & directed. Note : Spares shall be measured and paid for saperately under respective items.
Painting to desert coolers at site or site of work with two coats of synthetic enamelled grey paint on external surfaces, two coats of black anti corrosive paint on internal surfaces by spray painting machine including shutter, top, bottom including writing of MES NO. with 45 mm height letters, complete all as specified & directed.
Rewinding of electric motor of desert coolers of any capacity and size with copper winding wire of existing gauge including replacement of bushes and allied materials, complete all as specified & directed.
Electric motor for fan 18 / 20 " sweep, single phase, 3 speed, 100% water resistance, 100% dust proof withstand, voltage fluctuation 170V - 270V, rust proof totally enclosed with double ball bearing 1100 RPM, electric connection with copper cable of appropriate gauge including dismantling of old unserviceable electric motor, complete all as specified & directed. Make. Kenstar/ Usha/ Symphony
Mild steel bracket for cooler fan of existing size, complete all as specified & directed.
Condensor of 3.15 to 4 MFD, complete all as specified & directed.
Heavy duty MS fan blade for desert cooler of existing size, complete all as specified & directed.
Three speed electronic regulator for desert cooler, complete all as specified & directed.
PVC insulated and PVC sheathed flexible wire of 23/.0076" copper conductor, 3 core, complete all as specified & directed.
Plug top 3 pin 5 Amp for desert cooler, complete all as specified & directed.
15mm dia PVC pipe for desert cooler, complete all as specified & directed.
PVC distributor with one Inlet and three outlets heavy duty, complete all as specified & directed.
Wood wool pad of 750 gms weight, complete all as specified & directed.
Wire mesh powder coated for fixing wood wool pads, complete all as specified & directed.
Submersible / tullu pump of existing capacity, complete all as specified & directed.
Front grill steel frame of suitable size and capacity, complete all as specified & directed.
Side shutter steel frame of suitable size and capacity, complete all as specified & directed.
MS mounting fixtures/louvers for mounting of electric motor as per existing size & type, complete all as specified & directed.
WATER COOLER Taking down water cooler of any type and size from the site including removing all components such as water inlet connection, PVC waste water pipe preparation of surfaces for new paint by scratching old paint from inside and outside complete and refixing the same after necessary repair, complete all as speciifed & directed. Note : Spares shall be measured and paid for saperately under respective items.
Compressor (sealed unit) for water coolers 40/80 ltrs or 60/120 ltrs capacity of the same make and capacity complete with relay OLP, gas charging including taking out unserviceable compressor unit from water cooler 40/80 & 60/120 ltrs capacity, opening of compressor unit for ispection, complete all as specified & directed.
Gas charging CFC free including commissioning and testing, complete all as specified & directed.
Rewinding of electric motor of water coolers of 1/35 HP with super enamelled copper winding wire of existing gauge including replacement of bushes and allied materials, complete all as specified & directed.
Blower fan motor of water cooler 1/35 HP of existing make including taking down old unserviceable blower fan motor, complete all as specified & directed.
Thermostat for water cooler of existing capacity and make including taking down old unserviceable thermostat, complete all as specified & directed.
Wiring kit for water cooler of existing capacity and make including taking down old unserviceable wiring kit, complete all as specified & directed.
Condensor of fan for water cooler of existing capacity and make including taking down old unserviceable condensor, complete all as specified & directed.
Painting to water coolers of 40/80 Ltrs capacity with two coats of super enamelled paint of existing shade with spray painting machine including preparation of surface by scratching old paint etc , complete all as specified & directed.
Painting to water coolers of 60/120 Ltrs capacity with two coats of super enamelled paint of existing shade with spray painting machine including preparation of surface by scratching old paint etc , complete all as specified & directed.
Strainer (Micro filter) suitable for 1/4" dia gas pipe complete condensor coil of existing capacity and make for water cooler including taking down old unserviceable Strainer (Micro filter), complete all as specified & directed.
Condensor coil of existing capacity and make for water cooler including connection with gas welding or soldering with the refrigeration system and taking down old unserviceable condensor coil, complete all as specified & directed.
Overload protection relay of existing capacity and make for water cooler including taking down old unserviceable overload protection relay, complete all as specified & directed.
Relay assembly of existing capacity and make for water cooler including taking down old unserviceable relay assembly, complete all as specified & directed.
Float valve 15 mm dia of PVC heavy duty for water cooler including taking down old unserviceable float valve, complete all as specified & directed.
Water cooler tank of existing capacity and make for water cooler including taking down old unserviceable water cooler tank, complete all as specified & directed.
Waste pipe of existing capacity and make for water cooler including taking down old unserviceable waste pipe, complete all as specified & directed.
MS wastage water tray of existing capacity and make for water cooler including taking down old unserviceable wastage water tray , complete all as specified & directed.
Bib cock, 15mm bore, fancy type, chromium plated push type, screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified & directed.
PVC insulated and PVC sheathed flexible wire of 40/.0076" copper conductor, 3 core including taking down old unserviceable wire, complete all as specified & directed.
Plug top 3 pin 15 Amp for water cooler including taking down old unserviceable plug top, complete all as specified & directed.
REFERIGERATOR Taking out unserviceable compressor (sealed unit) from refrigerator of capacity 165/175 Ltrs, opening of compressor unit and replacement with new compressor of Kirloskar or equivalent existing make complete with relay and gas charging, complete all as specified & directed.
Taking out unserviceable compressor (sealed unit) from refrigerator of capacity 286/300/310/340 Ltrs, opening of compressor unit and replacement with new compressor of Kirloskar or equivalent existing make complete with relay and gas charging, complete all as specified & directed.
Thermostat switch of existing capacity and make for refrigerator including taking down old unserviceable thermostat, complete all as specified & directed.
Defrost timer TMDE706 SC cycle time 6H35M, 60 Hz/7H54M, 50Hz single phase 220-240v of existing make for refrigerator including taking down old unserviceable defrost timer, complete all as specified & directed.
Biometal component of 4/3 wire for freezer for refrigerator of 286/310/340 ltrs capacity including taking down old unserviceable biometal component, complete all as specified & directed. Make: LG/ Samsung
Compressor coil complete including gas welding and soldering of existing capacity and make for refrigerator of 165/175/215 ltrs capacity and taking down old unserviceable compressor coil , complete all as specified & directed.
Compressor coil complete including gas welding and soldering of existing capacity and make for refrigerator of 286/300/310/340 ltrs capacity and taking down old unserviceable compressor coil , complete all as specified & directed.
Magnetic door gasket of existing capacity and make for refrigerator of 165/175/215 Ltrs capacity including taking down old unserviceable gasket, complete all as specified & directed.
Magnetic door gasket of existing capacity and make for refrigerator of 286/300/310/340 ltrs capacity including taking down old unserviceable gasket, complete all as specified & directed.
Wiring kit of existing capacity and make for refrigerator of 165/300/310 Ltrs capacity including taking down old unserviceable wiring kit, complete all as specified & directed.
Freezer cabinet of existing capacity and make for refrigerator of 165/175/180 Ltrs capacity including taking down old unserviceable freezer cabinet, complete all as specified & directed.
Freezer cabinet of existing capacity and make for refrigerator of 286/310 Ltrs capacity including taking down old unserviceable freezer cabinet, complete all as specified & directed.
Copper capilary tube (036) of existing capacity and make for refrigerator including taking down old unserviceable copper capilary tube, complete all as specified & directed.
Gas charging CFC free for refrigerator of capacity 165 /175/180 litres including sealing of pipe, commissioning and testing, complete all as specified & directed.
Gas charging CFC free for refrigerator of capacity 286 to 310 litres including sealing of pipe, commissioning and testing, complete all as specified & directed.
Open type relay assembly of existing capacity and make for refrigerator of 165/175 Ltrs capacity including taking down old unserviceable open type relay assembly, complete all as specified & directed.
Open type relay assembly of existing capacity and make for refrigerator of 286/300/310 ltrs capacity including taking down old unserviceable open type relay assembly, complete all as specified & directed.
Overload protection relay of existing capacity and make for refrigerator of 165/175/180 ltrs capacity including taking down old unserviceable overload protection relay, complete all as specified & directed.
Overload protection relay of existing capacity and make for refrigerator of 286/300/310 ltrs capacity including taking down old unserviceable overload protection relay, complete all as specified & directed.
Bottel self of existing capacity and make for refrigerator of 165/175/286/300/315 ltrs capacity including taking down old unserviceable bottel self, complete all as specified & directed.
Ice tray of existing capacity and make for refrigerator of 165/175/286/300/315 ltrs capacity including taking down old unserviceable ice tray, complete all as specified & directed.
Vegetable tray of existing capacity and make for refrigerator of 165/175/286/300/315 ltrs capacity including taking down old unserviceable tray, complete all as specified & directed.
Waste water tray of existing capacity and make for refrigerator of 165/175/286/300/315 ltrs capacity including taking down old unserviceable tray, complete all as specified & directed.
lamp with holder of existing capacity and make for refrigerator of 165/175/286/300/315 ltrs capacity including taking down old unserviceable lamp with holder, complete all as specified & directed.
AIR CONDITIONING Taking down defective split/window AC of 1.5 ton capacity from any height and any places for repair and refixing at its original place after replacement of defective/wornout parts for making serviceable, complete all as specified & directed. Note : Worn out spares parts required for making AC serviceable/functional shall be measured and paid for separately under appropriate items.
Blower fan motor for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Compressor motor (sealed unit ) with gas charging for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Gas charging CFC free for split/window AC including commissioning and testing complete all as specified & directed.
Remote for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Printed circuit board for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Sheet metal enclosures single pole and neutral earth enclouser with a two pin and earth plug and socket complete with one single pole MCB 32 amps, 240 volts including taking down old unserviceable enclousers, complete all as specified & directed.
Thermostatic switch for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Starting relay for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Overload relay for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Wiring kit for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Starting capacitor 6-10 Mfd for blower fan motor of 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Starting capacitor 100-120 Mfd for compressor motor of 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Running capacitor 36-45 Mfd for compressor motor of 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Front grill for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Air filter any type and size (metalic type) for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Gas filter including soldering for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Condensing coil including soldering with existing system for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Cooling coil including soldering with existing system for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Condensor fan blade for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Operating knob for 1.5 Ton window AC of existing make and type, complete all as specified & directed.
Blower fan for 1.5 Ton split/window AC of existing make and type, complete all as specified & directed.
Maintenance and servicing of window type/split type AC including cleaning of filters, washing with soap solution after removing from site and refixing complete all as specified & directed.
Four way reversible valve for 1.5 Ton window AC of existing make and type, complete all as specified & directed.
Thermocole, 20mm thick of size 1 Mtr x 1 Mtr for covering of duct cover, complete all as specified & directed.
Foam insulation for copper condensor tubes, complete all as specified & directed.
PVC insulation tape for covering the foam insulation, complete all as specified & directed.
Relay 24 volts, 30 Amps, single contact type including taking down old unserviceable relay, complete all as specified & directed.
Relay 18 volts, 20 Amps including taking down old unserviceable relay, complete all as specified & directed.
Relay 18 volts, 6-10 Amps including taking down old unserviceable relay, complete all as specified & directed.
Terminal strip of voltage stablizers of capacity 1 to 5 KVA of existing make and type including taking down old unserviceable strip, complete all as specified & directed.
Complete wiring of voltage stablizer of range 1 to 2 KVA with 15 volts IC circuit of existing make and type including taking down old unserviceable wiring, complete all as specified & directed.
Complete wiring of voltage stablizer of range 3 to 5 KVA with 24 volts IC circuit of existing make and type including taking down old unserviceable wiring, complete all as specified & directed.
Trigger switch of capacity 01 Amps of existing make and type including taking down old unserviceable switch, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amps, flush type universal including taking down old unserviceable switch, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amps, flush type universal including taking down old unserviceable switch, complete all as specified & directed.
Kit-kat fuse 15 Amps of existing make and type including taking down old unserviceable fuse, complete all as specified & directed.
Bakelite kit-kat fuse 5 Amps of existing make and type including taking down old unserviceable fuse, complete all as specified & directed.
Dismantaling of main transformer winding and stamping and material and labour for re-assembling the stamping, rewinding of main transformer, single phase, 50 Hz, 0.5 KVA capacity with super enamelled copper winding wire of existing gauge/weight/turns/tapping and varnishing after repairs, complete all as specified & directed.
All as per Srl Item No.170 above but of capacity 1.0 KVA
All as per Srl Item No.170 above but of capacity 3.0 KVA
All as per Srl Item No.170 above but of capacity 4.0 KVA
All as per Srl Item No.170 above but of capacity 5.0 KVA
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC casing and caping 'ISI marked' of 20/30mm size as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories, fixing arrangements on wall /roof/floor by means of drilling by heavy duty hand drill and fixing with PVC rawl plug and screws including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan point controlled by one way switch, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 2.5 Sqmm drawn into and including PVC casing and caping 'ISI marked' of 20/30mm size as required, terminated in MS sunken box suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories, fixing arrangements on wall /roof/floor by means of drilling by heavy duty hand drill and fixing with PVC rawl plug and screws including single core FRLS PVC insulated unsheathed multi stranded copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent, complete all as specified & directed.
Notes for Srl Item No. 176, 177 (i) Unit rate includes for cutting chases whereever required and sinking for boxes, making good to walls / floors etc., complete, including white wash / colour wash as directed. (ii) Uniform coding of wiring i.e red / yellow / blue for phase black for neutral and green for earth is to be maintained.
Switch piano flush type 5 Amps 240 Volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, flush type universal, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, AC, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Sub main wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn through in and including PVC casing caping of 20/30mm, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, surface type on walls, roofs etc including one run of 4.00 Sqmm FRLS PVC insulated copper conductor for earth continuity wire in green color , complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC casing caping will be measured and paid as one unit only.
1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 6 Sqmm twin core cable flat or circular including taking down old unserviceable service connections, complete all as specified & directed.
ASIA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .