| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified |
| 2 | Accepted-Technical H NO 122 TYPE 4 GHTP POWER COLONY LEHRA MOHABBAT BATHINDA 151111 | BATHINDA | BATHINDA | PUNJAB | 151111 | Accepted-Technical Qualified |
| 3 | Accepted-Technical SITE OFFICE PTPS PANIPAT | Accepted-Technical Qualified |
| 4 | Accepted-Technical FLAT NO 10 2ND FLOOR SODDHI TERRECSES RAYKAR NAGAR DHAYARI PUNE 411041 | PUNE | PUNE | MAHARASHTRA | 411041 | Accepted-Technical Qualified |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
17 Mar 2026, 1:00 pmClosed
Jyoti Raman Sharma
CE DCRTPP Yamuna Nagar
ARC for PreventiveRoutine and Breakdown Maintenance of Electrical System Equipments HT LT Switchgear, HT LT Motors, Illumination System, Generator Protection system and Power and Control cables etc. Installed at DCRTPP, Yamuna Nagar for
2026_HBC_505311_1
20266A47A869 906D 4D57 B74B 36DAF8F8CA17711PGC
Open Tender
Electrical Works
Works
730 days
RATTANPURA
As per NIT
2 documents required · 2 mandatory
₹1,180
₹3.5 L
Yes
24 Apr 2026
26 Feb 2026
19 Mar 2026
26 Feb 2026
17 Mar 2026
26 Feb 2026
26 Feb 2026 - 28 Feb 2026
Part A
The contractor shall carry out various activities of Preventive /routine /breakdown Electrical Maintenance work of Unit-I & II as enlisted below during working hours or at odd hours, including holidays with his skilled manpower as per qualification below: Supervisors (Highly Skilled) for Each Unit as per Annexure (E) – Three year Diploma holder in Electrical with minimum experience of two years. Foreman (Highly Skilled) for Various sites of two general group of Unit I & II each as defined in Annexure(E)–Three year Diploma holders Electrical with minimum 1 year experience or minimum five years’ experience with ITI. He must be able to read engineering drawings and able to attend the fault independently. Technicians(Skilled B) for Various sites of two general group of Unit I & II each as defined in Annexure(E)–ITI in Electrical with minimum 2 year experience. Semiskilled worker (Semiskilled-B) for various sites of two general group of Unit I & II each as defined in Annexure (E) – ITI in Electrical with minimum 1 year experience. Maintenance Shift for each Unit-I & II, DCRTPP as defined in Annexure (E) - three shifts i.e. Morning, Evening and Night with four shift groups with a team of workmen consisting of Foremen and Technician in each shift. The above is the minimum manpower for Various sites as defined in Annexure (E) for each Unit which the contractor has to supply for executing the various maintenance activities for below listed works of Preventive /routine /breakdown Electrical Maintenance work round the clock in Unit-I & II DCRTPP Yamunanagar. However the manpower may be increased depending upon the quantum of work activity or as per the direction of Engineer In Charge. • Attending of Preventive/Routine/break down/repair maintenance work or replacement of all types of illumination fittings and panels in Control Room, Admin. Building, Service Building, Turbine Boiler, BOP Area. Maintenance of different types of welding receptacles, Removal of Circuitry faults of all lighting equipment’s, Junction Boxes, etc. making a cable joint by using jointing kit or dressing, laying & replacement of wiring. Replacement of 125/100/75/50/25 KVA Transformer including testing & Transportation installation, testing and commissioning of power plus fixing of boards, Painting of all lighting boards of Unit I &II of 2X300 MW, DCRTPP. Cleaning of all light fitting covers etc. • Cleaning & greasing of all HT & LT Motors control Panels, HT & LT Panels, Common Auxiliaries of Unit-I & II. Checking of Termination, Cleaning of Terminal Box. Cleaning of insulator, tightening of connection of HT & LT Motors. Removal and reconnection power cable of all HT & LT motors from both ends as and when needs. Shifting & Installation of LT motors up to 5.5.KW. • Shifting of damaged LT motor up to 5.5KW (to and fro) • Attending of Preventive/Routine/breakdown faults of ON/OFF type Motorized valves in Unit-I & II.(Installed at various locations in the main plant & off sites in Unit-I&II) • Cleaning & Tighting of Electrical connections of Exciter, Generator & its associated equipment’s & Panels. Cleaning and replacement of Carbon brushes of all DC motors and Generator rotor shaft etc. • Preventive /routine /breakdown Electrical Maintenance work including Replacement, Servicing and upkeep of EOT cranes, Miscellaneous Hoists and Cranes (electrical part only) installed at various locations of Unit-I & II. • Various miscellaneous work such as shifting of materials, Electrical connections work, fault troubleshooting and removal at various sites etc. For Part-B work extra manpower shall be deployed by the firm.
Part B
Replacement of Push on type heat shrink termination kits straight through / end termination system (one side)
Local shifting of damaged HT Motor from site to crane bay.
Installation of healthy motor from HPGCL Store/crane bay to site.
Local shifting of damaged BFP Motor one side i.e. site to Crane bay).
Installation of new BFP motor and its auxiliaries at site i.e. store to site
Maintenance and cleaning of all ESP (144KVA72KV) Silicon Rectifier Transformer.
Decoupling, removal & refitting of coupling, opening of foundation. Bolt and shifting of damaged LT Motor (local) for one side for:- Above 5.5KW to 30 KW
Decoupling, removal & refitting of coupling, opening of foundation. Bolt and shifting of damaged LT Motor (local) for one side for:- 30.1 KW to 75KW
Decoupling, removal & refitting of coupling, opening of foundation. Bolt and shifting of damaged LT Motor (local) for one side for:- 75.1 KW to 175KW
Replacement of Bearing of LT Motor at site:- Up to 5.5 KW
Replacement of Bearing of LT Motor at site:- Above 5.5KW to 30 KW
Replacement of Bearing of LT Motor at site:- 30.1 KW to 75KW
Replacement of Bearing of LT Motor at site:- 75.1 KW to 175KW
Removal and installation of supply connection for 1- phase & 3-phase exhaust fan TG Hall up to 3.8 KW
Complete Servicing of service T/F’s
Maintenance of street lights pole and complete fixture including circuit from JB to luminary fixture and LED.
Maintenance of LP’s / valve DB ‘s including changing of gaskets, repairing of door locks, complete painting and marking etc.(material is in scope of contractor )
Laying testing and termination of control cables PVC/XLPE armored/unarmored overhead cables All sizes upto 10 core above 2.5 mm2
Laying testing and termination of control cables PVC/XLPE armored/unarmored overhead cables All sizes upto 10 core above 2.5 mm2
Laying testing and termination of control cables PVC/XLPE armored/unarmored underground cables All sizes upto 10 core above 2.5 mm2
Laying testing and termination of control cables PVC/XLPE armored/unarmored underground cables All sizes upto 10 core above 2.5 mm2
Laying testing and termination of Power cables PVC/XLPE armored/unarmored overhead cables. 2C/3C/4C upto 25mm2
Laying testing and termination of Power cables PVC/XLPE armored/unarmored overhead cables. 2C/3C/4C upto 25mm2
Laying testing and termination of Power cables PVC/XLPE armored/unarmored overhead cables. 2C/3C/4C upto 25mm2
Laying testing and termination of Power cables PVC/XLPE armored/unarmored underground cables. 2C/3C/4C upto 25mm2
Laying testing and termination of Power cables PVC/XLPE armored/unarmored underground cables. 25 to 300mm2
Laying testing and termination of Power cables PVC/XLPE armored/unarmored underground cables. 150 to 300mm2
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.78 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_584034.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .