Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest bid | |
| 2 | L2₹22.8 L+₹5.1 L (28.7%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bid | |
| 3 | L3₹25.9 L+₹8.2 L (46.1%)Rejected-Finance VILL KASNI POST BIN DISTT PITHORAGARH UK | L3 | Rejected-Finance Being Higher Bid | |
| 4 | Rejected-Technical | - | Rejected-Technical due to uploading a Invailid DD(EXPIRED) |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
26 Jul 2021, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
CERTAIN BR REPAIR WORKS AND REPAIRS TO INTERNAL ELECTRIFICATION TO OTM ACCN AT MIL STATION CHARMAGAD UNDER GE MES PITHORAGARH
2021_MES_456150_1
8376/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Charmagad
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Pithoragarh
₹47,000
Yes
28 Aug 2021
1 Jul 2021
28 Jul 2021
1 Jul 2021
26 Jul 2021
14 Jul 2021
1 Jul 2021 - 14 Jul 2021
Amount
DESCRIPTION OF ITEMS
Demolition of brickwork or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles and block walling complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling timber scantlings 40 Sqcm and over in section in any position, complete all as specified and directed.
Dismantling fillets, purlins, etc under 40 Sqcm in section complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness in roof and wall covering complete all as specified and directed.
M & L for 40mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate as in foundation etc complete all as specified and directed.
S & F of 3mm thick Glass dividing strips insert to 28mm depth in flooring etc complete all as specified and as directed.
M & L for precast cement concrete block masonry with solid bloks exc 10cm width and setting in cement mortar 1:6 type C-1 1:3:6 (20 mm graded agg) complete all as specified and directed.
M & L for RCC 1:2:4 (Nominal Mix) with 20mm graded aggregates as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for form work to sides and soffits of roof beams, lintels, cantilever shelves incl supports, overhangs etc rough finished surfaces of concrete flat all as specified.
M & L for TMT bars 6 to 8 mm dia, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to as specified and directed
M & L for 2nd class hardwood clean sawn as in scantlings clean sawn timer framed and fixed as in column support, rafter, purlin and ceiling work complete all as specified and directed.
All as per item No 15 above but except timber
S & F of plain fillets of 2nd class soft wood square, rectangle or triangle with bull-nosed, splayed, chamfered or rounded on one edge or face in section clean sawn secured with nails sectional area exc. 3 but n. exc. 6sqcm complete all as specified and directed.
All as per item No 17 above but except battens.
S & F of plain fillets of 2nd class soft wood square, rectangle or triangle with bull-nosed, splayed, chamfered or rounded on one edge or face in section clean sawn secured with nails sectional area exc. 6sqcm but n exc. 13sqcm complete all as specified and directed.
All as per item No 19 above but except battens.
S & F of plain fillets of 2nd class soft wood square, rectangle or triangle with bull-nosed, splayed, chamfered or rounded on one edge or face in section clean sawn secured with nails sectional area exc. 13sqcm but n exc. 25sqcm complete all as specified and directed.
All as per item No 21 above but except fillets.
S & F ply wood grade BWR, type BB, 6mm thick, fixed to timber framed work with nails, fixed in ceilings, complete all as specified and directed.
S & F ply wood 6mm thick, fixed to timber framed work with screws, fixed in vertical surfaces as in partition wall complete all as specified and directed.
S & F in repairs second class softwood boarding 15mm thick, planed one side with butt joints, fixed with nails in any situation (except flooring and skirting) to replace old or decayed boarding in patches including cutting old complete all as specified and directed.
S & F in repairs of weather board second class softwood boarding20- 25mm thick, planed one side and edges half lap type fixed with nails in any situation (except flooring and skirting) to replace old or decayed boarding in patches incl cutting old complete all as specified and directed.
Taking down chowkhats or frames with shutters n.exc. 1.5 sqm each (without taking off shutter from the frame).
Taking down chowkhats or frames with shutter exc. 1.5 sqm and n.exc. 4 sqm each (without taking off shutter from the frame).
Taking down shutters of any description n.exc 1.0 sqm each.
Taking down shutters of any description exc 1.0 sqm and n.exc 2.0 Sqm each.
S & F second class hard wood as in plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F for 35 mm thick second class softwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkatcomplete all as specified and directed.
S & F for 35 mm thick second class soft wood Glazed and skeleton shutters for doors, open rebated and prepared to receive glass, gauze, etc., divided into squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with out mitred beads for securing glass etc size of members of door shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkhats complete all as specified and directed.
S & F for 25 mm thick second class hard wood Glazed and skeleton shutters for window/ ventilators, open rebated and prepared to receive glass, gauze, etc., divided into squares with plain, chamfered or rounded mitred and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with out mitred beads for securing glass etc size of members of door shutters as specified in SSR Part I, Section 8, clause 8.24 (b) fitted to chowkhats complete all as specified and directed.
Supply and fix Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube 47x47mm (19 gauge) all as specified and directed.
Supply and Fix factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fit-ted in the MS. frame welded/sealed to the stles & rals with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing n the frame at side as per specification & drawing complete all as specified and directed.
S & F M.S. Framed work such as grills grating, framed guard bars, railings etc, with ends of bars sholdered and / or riveted into spikes, all as directed.
S & F Galvanized mild steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.40 mm and fixed with wooden beading fixed by nails complete all as specified and directed.
S & F for Butt hinges 100mm, medium weight cold rolled mild steel etc complete all as specified and as directed.
S & F for Butt hinges 75mm, medium weight cold rolled mild steel etc complete all as specified and as directed.
S & F for Butt hinges 100mm, extruded aluminium alloy with galvanized mild steel hinge pin, anodised of type B-22 and complete all as specified and as directed.
Supply and fix mild steel, sliding door bolts, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and minimum of 6 bolts and nuts, four on bolt plate and two on staple plate length of bolt 300 mm complete all as specified and directed.
S & F for 200mm long alumunium barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F for 150mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S & F for 150 mm Extruded aluminium alloy handles, fabricated type, anodised for PVC doors complete all as specified and directed.
S&F for 150 mm cast iron or malleable cast iron handles, cast type, polished bright complete all as specified and directed.
S & F for Door closer of cast iron body hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700mm in width and of weight not more than 35 kg and fixed complete all as specified and directed.
S & F for mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S & F for mild steel work in wind ties with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe290 Gde-E-165 complete all as specified and directed.
Fixing only old Mild steel work in wind ties, including securing bolts, drilling holes etc. including all necessary drilling, bolting or riveting, etc., and similar work complete all as specified and directed.
S & F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side laps fixed with coach screws and washers in roofs etc with grade of zinc coating 275 complete all as specified and as directed.
All as per Sl No 51 above but except sheets.
S & F 0.63 mm thick plain galvanised mild steel sheeting as in ridges, hips, valley gutter, drip, crumple and straight flashing (length and girth as fixed), fixed with coach screws and washers having grade of zinc coating 275, complete all as specified and as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons laid, bedded and pointed in any mortay etc complete all as specified and directed.
Taking down cement or cement lime plaster including tiles if exists, from brick or stone walls, ceilings etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25mm thick over and including 20mm thick cement screed bed in 1:6 CM laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including15 mm thick back cement screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in CM 1:4 to be finished even and smooth ( without using extra cement) complete all as specified and directed
M & L for Preparation of new (Previously untreated) plastered surfaces of walls and applying two coats of cement based paint on walls, complete all as specified and directed
M & L preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer on new wooden surfaces all as specified.
M & L for preparing surfaces and aplying of one coat of synthetic enamal paint over one coat of pink primer on new wooden surfaces in ceiling complete all as specified and directed
M & L for preparation and applying on new steel surfsces of any decription otherwise over 10 cm width or girth two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames, glazed with oil putty or fixed with beads complete all as specified and directed.
S & F 4.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exc. 0.5 sqm in each pane complete all as specified and directed.
S & F in repairs vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests and including trap, and to flushing pipe, anti syphonage pipe, etc and connection complete making good to floors and complete all as specified and as directed.
S & F in repairs viterous China wash down water closet EWC including to connection to drain and flush pipe (excluding flushing cistern and flushing pipe) incl trap set complete all as specified.
S & F in repair 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, and connections to pipes and fixing flush pipe to squatt pattern closet including all joints and making good to the floor complete all as specified and directed.
S & F in repair Vitreous China bowl urinal flat back size of 465x 355x265 mm white with grating and inlcuding union for discharge pipe complete all as specified and directed.
S & F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe ( min wt 60 gms ) complete all as specified and directed
S & F in repair 15mm bore bib taps, fancy type, chromium plated, cast copper alloy with with crutch or capston head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed
S & F in repair 15mm bore bib taps, PTMT with crutch or capston head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15mm bore angle valves / angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms ) etc complete all as specified and directed
S & F in repairs 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed.
S & F in repair Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S & F in repair for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
S & F in repair Shower arm 15 mm size, 195mm long with bend of 45degree with flange of brass CP complete all as specified and directed.
S & F in repair of chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union . complete all as specified and directed.
S & F in replacement PVC connection 15mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F in repair vitreous china WHB white flat back size 550 x 400 mm including CI bracket complete all as specified and directed
S & F in repair 15 mm dia pillar tap, brass chromium plated, fancy type, cast copper alloy complete all as specified and directed
S & F in repair 15 mm dia pillar tap, of Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms complete all as specified and directed.
S & F in repair PVC waste pipe 32 mm to 40 mm dia size of adequate length (minimum length 60cms) suitable for WHB/Sink with PVC adopter fixed in repairs complete all specified and directed
Taking up or down 15 mm bore steel tubing and connection all as directed.
Taking up or down 20 mm bore steel tubing and connection all as directed.
S&F 15mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
S&F 20mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed.
Demolition and breaking up drain pipes AC or pvc pipe 75mm internal dia, set in cement mortar.
S&F PVC (SWR) pipe 75mm bore dia, single socketed, in any length with rubber ring joint, laid in trenches or in floor complete all as specified and directed.
S & F PVC (SWR) bend for 75mm bore of pipe, any radius complete all as specified and directed.
S&F in repair of curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as spd and dsirected.
S & F in repair PVC grating 75mm dia of of PTMT (minimum weight 250 gram) complete all as specified and directed.
S & F in repair for 500 ltr PVC Rotational moulded polyethylene water storage tank ( cylindrical vertical with closed top) triple layered hoisted and fixed in position all as specified in SSR Pt I complete all as specified and directed.
Disconnecting existing over head water storage tanks of capacity exc 200 ltrs but n.exc 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and removing all scale and dirt etc from tank and from mouth of circulating pipes etc and hoisting if required reconnecting and re-fixing in position complete including embossing date of completion of cleaning by stencil with using synthetic enamel paint all as specified and directed.
S & F 20 mm dia ball brass valves, high pressure with polythene float and flyut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
M& L for preparation of old wooden surface and applying one coat of synthetic enamel paint on surface any description over 10 cm width or girth complete all as specified and directed.
M & L for preparing surfaces and aplying of wood and wood based materials new or old of any description and girth, not otherwise described, and treated with one coat of creosote oil complete all as specified and directed
M&L for preparation of old steel surface and applying one coat of synthetic enamel paint on surface any description over 10cm width or girth complete all as specified and directed.
M & L for preparation of old surface and applyingcoat of synthetic enamel paint (M.B.Green) on steel surfaces of corrugated / plain sheets as in roof covering over 10cm width or girth including prepration of surface complete all as specified and directed.
M & L for Preparation of old (Previously treated) plastered surfaces of walls and applying one coats of cement based paint on walls, complete all as specified and directed
Taking down carefully old Aluminium / copper point wiring (Light fan socket or power) complete, (fittings such as switches, ceiling roses, pendants, sockets etc), removing materials from site and making good disturbed surface of walls, floors etc, complete all as specified and directed.
M & L for point wiring surface type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non metallic PVC surface conduit 20 mm or higher dia, ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly, screwed with screws, cup washers complete all as specified and directed for the following :-
(a) One light point/ fan/ exhaust fan point/bell point controlled by one, one way switch of 5/6 Amps.
(b)one socket outlet three pin 5 amps control by one switch on the same board
(c)one socket outlet three pin 5 amps control by one switch on independent board
~Ditto~ all as per Item No 103 above but with 2.5 Sq mm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete.
Supply and Fix Switch piano, flush type, white finish, 5/6 amps, single pole, one way complete all as specified and directed.
Supply and Fix Socket outlet 5 pin, 5/6 amps and flush type, non shutters, non inter locking type, complete all as specified and directed.
Supply and Fix Switch piano flush type, white finish, 15/16 amps, single pole, one way, complete all as specified and directed.
Supply and Fix Socket outlet 2 in 1, 5/6 pin, 5 and 15 amp flush type, complete all as specified and directed.
Supply and Fix in repair of bell push AC SP 240 volts flush type 5/6 Amps, single pole one way complete as all specified and directed.
Supply and Fix in repair of bell electric Ding Dong type/multi music type, AC, SP 240 volts, complete as all specified and directed.
S & F in repair Electronic fan regulator flush type, 300 W Step type, 230 volts ISI marked complete all as specified and directed.
Supply and Fix ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed.
Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amp complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure TPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure , SPN, 8 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB DB sheet metal enclosure for DB, SPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grauting suitable for housing MCB's and isolators, complete all as specified and directed.
Supply and Fix in repair MCB single pole, 240 volts, 6-32 Amps of 10 KA ‘C’ series 240 Volts complete all as specified and directed.
Supply and Fix in repair MCB single pole & Neutral ‘C’ series 240 Volts, 6-32 amps, of 10 KA complete all as specified and directed.
Supply and Fix in repair MCB Triple pole & Neutral ‘C’ series 240 Volts, 63 amps, of 10 KA , complete all as specified and directed.
Supply and Fix in replacement of 1x20 watt LED security light fitting, pressure die-cast aluminium including fixing the same of GI pipe 25 mm dia bore light grade bracket, 1.5 mtr long including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x4mm duly painted and suitable size of nut & bolts etc. and making electric connection with two core copper flexible wire of 0.50 Sqmm complete all as specified and directed.
S & F in replacement LED bulk head 10 Watt with PDC aluminium housing and milky diffuser complete all as specified and directed.
Supply and fix in replacement of LED Integrated Batten T5 box type surface mouted, (1x18 Watt) prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting complete all as specified and directed.
Supply and fix in replacement of LED Integrated Batten with Polycarbonate housing, surface mounted, (1x9 Watt) prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting complete all as specified and directed.
M & L for earthing in replacement complete with galvanized steel earth plate electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed.
Supply & fixing in replacement of 1100 volts grade heavy duty round cable with PVC insulated aluminiuum conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one twin core 10 sqmm solid conductor complete all as specified and directed.
M&L for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x6 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn in with and including PVC conduit along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor including taking down of old unserviceable wiring complete all as specified and as directed. (Note -: 1. Three runs of 6 Sqmm and one run of PVC conduit shall be measured as one unit. 2. Cost of cutting chasing and making good of surface shall be deemed included in quoted unit rate.
M&L for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x4 Sqmm, of code Red for Phase, Black For Neutral & Green For Earth concealed in wall and drawn in with and including PVC conduit along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor taking down of old unserviceable wiring complete all as specified and as directed. (Note : 1. Three runs of 4 Sqmm and one run of PVC conduit shall be measured as one unit. 2. Cost of cutting chasing and making good of surface shall be deemed included in quoted unit rate.
m/s MD pandey sons
M/S KS Shahi and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .