Loading…
Loading…
Tender ID
Tender Value
₹30.6 L
EMD Value
₹31,000
Closing Date
27 Jan 2026, 6:00 pmClosed
Executive Engineer office, Dang (R&B) Division, Ahwa
SUPPLYING AND FIXING FIRE SAFETY EQUIPMENT IN ITI BUILDING AT SUBIR, AHWA-DANG.
266476
22 OF 2025 - 26
Open
Fire and Safety Services
Works
Dang
19 documents required · 18 mandatory · 1 optional
₹1,500
Yes
Executive Engineer, Dang (R&B) Division, Ahwa
₹31,000
Yes
17 Jan 2026
17 Jan 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
SUPPLYING AND FIXING FIRE SAFETY EQUIPMENT IN ITI BUILDING AT SUBIR, AHWA-DANG.
Bill of Quantities.
(A) Percrentage Rate Tender ( Up to INR 50 cr.)
Quantities Rate In
Item estimated but figure
Descripction of Item Unit Amount
No. may be more or
1 Supply. installation, testing & commissioning of ISI 1.00 No 116150.00
approved electrical motor driven jockey pump set
having 10.8 m3/hr. @ 70m head.The pump unit shall
be a horizontally direct mounted motor. Unit shall
comprise the following minimum requirements:
a)Pump, b) Electric motor IE2, c) Foundation bolts, d)
Mating flanges with gasket and fasteners, e)
Discharge gauges, etc.complete in all respect, with
2 Supply, installation, testing &commissioning of 1.00 No 35956.00
Priming tank, HDPE type, 1000 litres, with necessary
piping 100 mm size, G.I pipe for priming the pumps,
pipe of with butterfly valves for isolation, Water Filling
to priming tank by piping min. 50 mm size, with all
3 Supply, installation, testing &commissioning of 1.00 No 55600.50
Manifold( surge vessel,)for fire hydrant system,
min.300 mm diameter,made from M.S plate, hydro
tested to 15 kg./cm2. with ball valves, header with
couplings for fitting pressure switches,pressure
gauges etc.with necessary isolation valves with all
4 Supply, fabrication & erection of aboveground G.I. 'C'- 5.00 Mtr 454.50
Class, ERW piping,conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.Hydrostatic testing for 2 hour's at 150%
of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 25 mm dia.
5 Supply, fabrication & erection of aboveground G.I. 'C'- 15.00 Mtr 808.00
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.Hydrostatic testing for 2 hour's at 150%
of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 50 mm dia.
6 Supply, fabrication & erection of aboveground G.I. 'C'- 25.00 Mtr 1565.50
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.Hydrostatic testing for 2 hour's at 150%
of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 80 mm dia.
7 Supply, fabrication & erection of aboveground G.I. 'C'- 200.00 Mtr 1999.80
Class, ERW piping, conforming to IS:1239, part-I,
Heavy class up to 150 mm dia. and IS:3589, for size
200 mm dia. & above, thickness. G.I. pipe fitting's as
per IS: 1239, part-II, Heavy class for size 150 mm dia.
& below & IS: 3589, for size 200 mm dia. above,
flanges, nuts bolts & washers, 3 mm thick gasket, pipe
hangers, etc.Hydrostatic testing for 2 hour's at 150%
of the system pressure, hook-up etc.
Painting for piping, fittings & structural pipe support,
shall be two coat of zinc primer and two coats of fire
red conf. to IS: 5, Shade 536. Complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. 100 mm dia.
8 Supply, installtion, testing & commissioing of 20.00 Mtr 2171.50
Underground GI (ERW) piping conforming to IS:1239,
part-I, Heavy class ('C' class) up to 150 mm dia. and
IS:3589 Heavy class ('C' class), for 200 mm dia. &
above, min. 6.35mm thickness including Heavy class
fittings, anti-corrosive tape of size 150 mm wide x
mm thick, wrapping & coating with 13KV holiday
testing . Rates shall include sand bedding of 75mm
dia all around, backfilling of the excavated including
installation of heavy pipe fitting's, flanges, etc. 10 % of
all the welded joints shall be done radiographically
tested and 50% of the joints radiographed shall be the
"Field Joints". Hydrostatic testing for 2 hours at 150%
of the system pressure, hook-up etc., complete with all
accessories as per approved drawings, specicification
and direction of the Engineer-in-Charge, with all
complete. (Road Crossing) 100 mm dia.
9 Design , Supply and installation of Safety Signage 3240.00 Sq. 10.10
made of Zinc Sulphilde based glow in dark , Rigid inch
sheet with High Luminous property enclosed in a
transperent weather proof UV stabilized plastic pasted
on 3 mm thick clear acrylic sheet such as EXITS,
EMERGENCY EXIT, DO NOT USE LIFT DURING
FIRE, FLOOR MARKINGS, FIRE LIFT, STAIRCASE
EXIT, FIRE ALARM CALL POINT, FIRE HOSE REEL,
FIRE HYDRANT POINT etc.
10 Supply, installation, testing & commissioning of 5.00 No 3333.00
pressure switch. (Range 0 to 16 kg/cm2)
11 Supply, installation, testing & commissioning of 150 8.00 No 3080.50
mm dia. dial Burdon Type Glycerine Filled pressure
gauge with isolation ball valve arrangements with
necessary isolation valves with all complete.( Range
12 Supply, Installation, Testing & Commissioning of Cast 4.00 No 2878.50
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 50 mm dia.
13 Supply, Installation, Testing & Commissioning of Cast 4.00 No 3232.00
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 80 mm dia.
14 Supply, Installation, Testing & Commissioning of Cast 4.00 No 3636.00
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 100 mm dia.
15 Supply, Installation, Testing & Commissioning of Cast 1.00 No 5302.50
iron body Butterfly valve according to IS: 13095, PN-
1.6, Iron Disc for size 150 mm dia. & below Lever
operated and above 150 mm dia. Gear operated
complete with mating flanges /ANSI class # 150 with
bolts & nuts washers, rubber gaskets 3 mm thick, etc.,
with all complete. 150 mm dia.
16 Supply, installation, testing & commissioning of Cast 2.00 No 2878.50
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with
all complete Accessories 50 mm dia.
17 Supply, installation, testing & commissioning of Cast 3.00 No 3232.00
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with
all complete Accessories 80 mm dia.
18 Supply, installation, testing & commissioning of Cast 2.00 No 4292.50
iron body Dual Plate Wafer Type NRV conf. to IS:
PN-1.6 complete with mating Flanges class # 150 with
bolts & nuts, washers, gaskets 3 mm thick, etc., with
all complete Accessories 100 mm dia.
19 Supply, installation, testing & commissioning of SG 1.00 No 1818.00
iron body SinglePlate Wafer Type NRV conf. to
ASTMA 536, PN-1.6 complete with mating Flanges
class # 150 with bolts & nuts, washers, gaskets 3 mm
thick, etc., with all complete. Accessories 80 mm dia.
20 Supply, installation, testing & commissioning of SG 1.00 No 2121.00
iron body SinglePlate Wafer Type NRV conf. to
ASTMA 536, PN-1.6 complete with mating Flanges
class # 150 with bolts & nuts, washers, gaskets 3 mm
thick, etc., with all complete. Accessories 100 mm dia.
21 Supply, installation, testing & commissioning of Y 2.00 No 6565.00
Type Strainer complete with mating flanges with bolts
& nuts, washers, gaskets 3 mm thick, etc., with all
complete accessories. 80 mm dia.
22 Supply, installation, testing & commissioning of Y 3.00 No 7928.50
Type Strainer complete with mating flanges with bolts
& nuts, washers, gaskets 3 mm thick, etc., with all
complete accessories. 100 mm dia.
23 Supply, installing, testing and commissioning of 2.00 No 4898.50
Normax make CI heavy duty ball type foot valve with
flanges, nut bolts, gaskets etc. with necessary
complete accessories. 80 mm dia.
24 Supply, installing, testing and commissioning of 2.00 No 7575.00
Normax make CI heavy duty ball type foot valve with
flanges, nut bolts, gaskets etc. with necessary
complete accessories. 100 mm dia.
25 Supply, installation, testing & commissioning of Four 1.00 No 9595.00
way fire brigade Inlet connection with 63 mm dia.
stainless steel (SS304) instantaneous male inlets with
built in non return valve in each inlet with 150 mm dia.
header pipe, suitable rubber cap and GI chain
including nuts, bolts, washers, gasket 3 mm thick, etc.
with all complete.
26 Supply, installation, testing & commissioning of Two 1.00 No 5201.50
way fire brigade Inlet connection with 63 mm dia.
stainless steel (SS304) instantaneous male inlets with
built in non return valve in each inlet with 100 mm dia.
header pipe, suitable rubber cap and GI chain
including nuts, bolts, washers, gasket 3 mm thick, etc.
with all complete.
27 Supplying FIRE bucket round bottom of 9 liters 8.00 No 1212.00
capacity made out of 24 gauge G.I Sheet with extra
handle at bottom duly painted white inside and Red
out side with FIRE mark. Filled with dry-sand and kept
on existing stand provided or hung on wall hook.
28 Supplying and erecting floor mounting Stand for 2.00 No 5706.50
keeping four nos. of FIRE buckets comprising
mm in length, 900 mm height frame made out of
30mm x 30 mm x 4 mm angle iron with cross supports
legs, welded with 4 hooks and duly painted with one
coat of primer and two coats of approved enamel P O
29 Supply & installation of stainless steel body Orifice 12.00 No 1161.50
Plate of suitable inner bore along with matching flange
- as per specification & requirement as per hydraulic
30 Providing and fixing approved make Perforated C type 10.00 Mtr 656.50
cable tray. Made from pre- galvanized sheet steel.
The cable tray should be bended as per IS 2062/1079
. with max 17.5% perforation with coupler plate / Fish
plate and GI hardware like nut - bolt and washers etc.
erected on existing support as per Specification and
as per instruction of engineer in charge..(5) 300 X
31 Providing and fixing approved make Perforated C type 10.00 Mtr 353.50
cable tray. Made from pre- galvanized sheet steel.
The cable tray should be bended as per IS 2062/1079
. with max 17.5% perforation with coupler plate / Fish
plate and GI hardware like nut - bolt and washers etc.
erected on existing support as per Specification and
as per instruction of engineer in charge..(3) 150 X
32 Supply, installation, testing & commissioning of 12.00 No 6565.00
Oblique pattern type stainless steel (SS 304) single
headed External Fire Hydrant Valve with 63 mm dia.
female instantaneous outlet conf. to IS: 5290, type - A,
including mating flanges, galvanised nuts, galvanised
bolts/studs, washers & gaskets 3 mm thick with all
33 Supply, installation, testing & commissioning of 63 mm 12.00 No 2171.50
dia. stainless steel (SS 304) Universal Branch Pipe
34 Supply & installation, testing & commissioing of Fire 12.00 No 7272.00
Fighting Hose - conf. to IS : 636, type B (type- 3), The
fire hose shall be 15 m long with 63 mm dia. stainless
steel (SS 304) couplings conf. to IS: 903, at both the
ends for connection with the hydrant valve and the
35 Supply, installation, testing & commissioning of 12.00 No 3535.00
fabricated from 3 mm MS sheet, hose box of size-450
mm x 600 mm x 250 mm - painted with Fire Red as
per IS: 5, shade no. 536 front 3 mm thick transparent
glass with lock & key, handle and brass hinges - to
accommodate one number of 15 mtr long hose and
one number of universal branch pipe, including
supporting arrangement with civil work.
36 Supply, Installation, testing & commissioing of 12.00 No 8736.50
Swinging type mild steel hose reel drum with 20 mm
dia. x 30 mtr. rubber hose as per IS: 884. The
mounting stand shall be of mild steel and the hose
shall be fitted with a SS shut-off nozzle & SS ball valve
of 25 mm dia. including supporting arrangement with
all complete. accessories
37 Supplying, fixing & testing of of CI ball Valve 25mm 20.00 No 757.50
38 Supplying, fixing & testing of New Battery of diesel 1.00 No 16665.00
engine 150 Amp.
39 Supply and installation of Diesel Tank For Diesel 1.00 No 17675.00
Engine With All Accessories 100 Ltrs.
40 Supplying, filling & testing lube oil for diesel engine 20.00 Ltrs 353.50
41 Supply and commissioning of Oil Filter. 1.00 No 757.50
42 Supplying, filling of diesel in diesel engine tank 100.00 Ltrs 101.00
43 Supply and commissioning of Diesel Filter 1.00 No 454.50
44 Supplying, filling & testing coolant to engine cooling for 20.00 Ltrs 252.50
45 Excavation for foundation upto 1.5 m depth including 15.00 Cu. 275.33
sorting out and stacking of useful materials and Mtr
disposing off the excavated stuff upto 50 Meter
lead.(A)Hard Murrum
46 Filling Of Gaps Between pipe and Core Cutting Hole 30.00 No 353.50
With Chemical and Cement
47 Steel work, welded in built up sections framed work 250.00 Kg 101.00
including cutting, hoisting, fixing in position and
applying a priming coat of read lead paint & two coat
oil paint. (A)In beams and joists, channels angles
Tees, flats, with connecting plates or angle cleats as
in main and cross beams. Hip and jack rafters, purlins
conneted to common rafters and the like.
48 Supplying & erecting XLPE(IS:7098)(I)-88 ISI 35.00 Mtr 136.35
unarmoured copper cable 1.1 KV grade to be erected
as directed of following size. (E) 3 core 2.5 Sq. mm
for pressure switch
49 Providing and erecting XLPE(IS:7098)(I)-88 ISI 35.00 Mtr 285.83
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cable. (Only Fire Panel to Fire Pump)
(B) 3 core 4 Sq. mm
50 Providing and erecting XLPE(IS:7098)(I)-88 ISI 35.00 Mtr 497.93
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cable. (Only Fire Panel to Fire Pump)
(D) 3 core 10 Sq. mm (Only Fire Panel to Fire Pump)
51 Providing and erecting XLPE(IS:7098)(I)-88 ISI 35.00 Mtr 213.11
armoured cable multistrand Copper conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cable for Diesel Engine Battery
Charger (A) 3 core 2.5Sq. mm
52 Supply, Filling and Fixing of approved make ABC type 18.00 No 1968.64
fire extinguisher - 6 Kg. Capacity as per IS:15683 &
53 Supply, Filling and Fixing of approved make CO2 type 18.00 No 5520.76
fire extinguisher. Capacity 4.5 Kg. (conforming to IS-
54 Supply, Filling and Fixing of approved make ABC 3.00 No 3423.73
Moduler type automatic fire extinguisher. Capacity
Kg. (conforming to IS-15683).
55 Submitting the application to obtain Fire Plan Approval 2.00 No 151500.00
and After Completion of Work Obtain Final Fire NOC
56 Supply, Installation and commissioning of Air Release 3.00 No 1515.00
Valve, 25 mm Dia. connection.
57 Supply, Installation and commissioning of Fire Alarm 2.00 No 25856.00
Panel Conventional type, 4 zone, with complete
58 Supply, Installation and commissioning of smoke 12.00 No 1515.00
detectors / heat detectors, with complete accessories.
59 Supply, Installation and commissioning of plug in base 12.00 No 303.00
for the smoke detectors, hooters, with complete
60 Supply, Installation and commissioning of Audio 12.00 No 1212.00
hooters , with complete accessories.
61 Supply, Installation and commissioning of Manual Call 12.00 No 1191.80
Points, with complete accessories.
62 Providing and erecting Fire Alarm Armoured Cable 2 400.00 Mtr 126.25
core 1.5 Sq. mm for Fire Alarm System
63 Core cutting in wall and in RCC slab with size as 15.00 No 404.00
below: 50 mm dia. Hole
64 Core cutting in wall and in RCC slab with size as 5.00 No 505.00
below: 80 mm dia. Hole
65 Core cutting in wall and in RCC slab with size as 3.00 No 606.00
below: 100 mm dia. Hole
66 Core cutting in wall and in RCC slab with size as 5.00 No 757.50
below: 150 mm dia. Hole
67 Core cutting in wall and in RCC slab with size as 2.00 No 909.00
below: 200 mm dia.
68 Supply, installation, testing & commissioning of ISI 1.00 Set 191900.00
approved electrical motor operated Kirloskar make fire
hydrant main pump set horizontal end suction back
pull out top discharge centrifugal fire pump set with all
the standard acessories, base frame, coupling, and
foundation bolts with following specifications Model -
Flow-54 m3/hr,Head-60 meter,Motor Rating -
22KW/30HP/3 ph, Suc x Del - 80 x
69 Supplying, Installation, Testing and commissioning of 1.00 Set 449450.00
Kirloskar make diesel engine driven fire hydrant pump
set suitable for automatic operation and consisting of
following: horizontal type, centrifugal end suction back
pull out, top discharge pump of cast iron body &
bronze impeller with m.s.fabricated common base
plate, coupling, coupling guard, foundation bolts
etc.,as required. Model -KFE Flow-54 m3/hr,Head-70
meter, Engine - 39 BHP Suc x Del - 100 x
70 Fire Hydrant Panel suitable for 10 hp Jockey pump, 30 1.00 No 97465.00
hp (54 m3/hr @ 70 m head) main electrical pump and
39 hp (54 m3/hr @ 70 m head) Diesel engine operated
A) Incomer MCCB - 1 Nos R Y B Indication - 1 Set
VAF Digital Meter - 1 Set
B) Outgoing F1 30 HP Star Delta Starter - 1 For
Main pump F2 10 HP DOL Starter - 1 For Jockey
Pump F3 Auto - On / Off Diesel Pump With Battery
Charger Control Circuit With Auto - Manual On/Off
On/Off Trip Indication On/Off Push Button
C) Fabrication Dully Powder Coated PO Red
Colour,Fabricated From 14/16 SWG,GI Sheet , IP-42
Protection,-Fixed Type Floor Mounted
Cable Entry : Bottom
71 Pay Legal Fees to Concern Authority for Obtaining 2400.00 Sq.mt 15.15
Plan Approval and Final NOC
72 PVC Tank with necessary Piping 20000.00 Litre 10.10
Net Total Amount =
Net Total Amount =
I we am / are willing to carry out the work at …................................ % above/ Below percent ( Should Be writen in
figures And words) of the estimated rate mentioned above. Amount of my / our tender works out as under.
Estimated Amount Put to tender. Estimated Amount Put to tender
Deduct…........ % Below Deduct…........ % Below
In Words In Words
(1) The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-
Charge for which no extra payment shall be made.
(2) The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
(3) GST and Income tax TDS will be deducted at a source while making payments of bills
(4) In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as
per actual mix design the cost of difference of cement consumption have been deducted from the rate of original item at
the rate of input rate mentioned in all the tender.
Signature of Bidder
Deputy Executive Engineer, Divisional Accountant
Dang ( R&B) Sub Division, Dang ( R&B) Division,
Executive Engineer,
Dang ( R&B) Division,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Annual Maintenance Special condition ITI Subir.pdf
BOQ ITI SUBIR fire.pdf
Eligibility Condition special condition ITI Subir.pdf
SBD Fire EMRS ITI SUBIR.pdf
Technical special condition ITI Subir.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .