Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND RESONABLE | |
| 2 | L2₹14.9 L+₹54,940 (3.83%)Rejected-Finance VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 3 | L3₹15.6 L+₹1.3 L (8.81%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 4 | L4₹15.6 L+₹1.3 L (8.81%)Rejected-Finance | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE | |
| 5 | L5₹15.8 L+₹1.5 L (10.5%)Rejected-Finance GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L5 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT RESONABLE |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Sept 2024, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
REPAIR MAINT OF STREET LIGHT FITTINGS AND ALLIED WORKS UNDER GE RAMGARH CANTT
2024_MES_667833_1
8300/3275/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹30,000
Yes
5 Dec 2024
25 Jul 2024
23 Sept 2024
25 Jul 2024
16 Sept 2024
8 Aug 2024
Amount
Attending Day to Day complaints of street lights like burned wire line/cable fault ,taking down unserveciable street lights and refixing the same after reparing of existing street lights including removing carbon /rust etc with & including connecting in existing circuit with flexible wire 2 core 2.5sqmm copper conductor 1.5mtr long all as specified and directed. complete all as specified and directed.
Taking down / dismantling unserviceable Street/Security light/Post top lantern light fitting of any wattage or size from existing electric poles or bldg for replacement of unserviceable lights for taking credit to the contractor complete all as specified and directed.
M&L for FREEDOM NEO LED streetlight 45 Watt made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics with IP65 protection including connecting in existing circuit with flexible aluminium conductor of size 2 core 2.5 sqmm of 2 mtr long complete all as specified and directed.
M&L for LED street lights 60 Watt, aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics and IP66 protection of including connecting in existing circuit with flexible aluminium conductor of size 2 core 2.5 sqmm of 2 mtr long complete all as specified and directed.
M&L for JETA ALBA Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, 60W suitable for high mass lighting including connecting in existing circuit with flexible aluminium conductor of size 2 core 2.5 sqmm of required at site including taking down existing flood light complete all as specified and directed.
S&F for New generation, IP 65 LED post-top lantern lights of 15 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including testing complete all as specified and as directed.
S&F in repair 40/32 mm dia bore galvanize iron pipe light grade, bent to shape of length 1.50 mtr fixed with flat iron clamp of size 50 mm x 6 mm nuts and bolts of 12 mm dia 100 mm long including washer duly painted with two coat of synthetic enamel paint over a coat or red oxide primer on exposed surface of mild steel surface including preparation of surface including and fixing on pole /wall complete all as specified and directed
Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 4.0 sq. mm two core nominal cross section in stranded conductor including testing and taking down of existing cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm two core nominal cross section in stranded conductor including testing and taking down of existing cable complete all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth for cable trenches and getting out in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed by the Engineer-in-Charge.
M&L for Sub class "B" bricks laid dry width wise across the line of cable in trenches as cable protection complete all as specified.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supply and laying in replacement of GI pipe 50 mm dia light grade with all necessary fittings for cable protection on pole complete all as specified and as directed.
M&L for painting to existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with one coat of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, complete all as specified & directed.
S&F in repair cubical type cable junction box of size 195 mm x 135 mm x 90 mm fabricated /made out of 2 mm thick CRCA steel sheet junction box for street light pole mounted suitable for mounting on round pole & suitable arrangement for fixing of junction box such as bracket,clamp,nut & bolt etc., complete including one single pole MCB 20 Amp breaking capacity 10 KA ,"B" series complete all as specified and directed.
S&F in repair aluminium conductor of size 2.5 Sqmm 2 core for replacement of existing worn out/burnt cable on street light/security light by spiral hanging of wire for connectons from junction box to street light complete all as specified and directed.
S & F digital time swtiches with night sensor type with programming using capative segments with 24 hours timing setting AC 230 volt ,AC contractor(relay) , 40amps including four module weather proof cabinate IP-65 protection complete all as specified and directed as approved by GE.
luminaries should have an intelligent pre-programmed dimming profile suitable to provide 2 days backup.Luminaries should have IP-65 for all critical components,IK07 and have lumen output of greater than 4800 lumens/watt) as LM79 from NBL cddredited Lab the LED chip used should be of Osram,Lumileds,and should be with lenses for effective light distribution.Solar Panel ,MPPT charge controller and luminaries should be manufactured on India only the solar lighting company must have in house NABL accredited lab to justify luminaries system efficacy.Luminaries must have Green & Red indicator lights for showing charging of battery and low batteryvoltage respectively.Light fixture must also have protection like over charged protection ,Deep discharge protection over voltage protection.Thesolar lighting companies must toll free service network to provide immedite after sales services networks available in different districts of the state approved complete all as specified and directed as approved by GE comprising folloeings items :- (a) Solar Panel (b) Battery12 volt(c) LED Solar light
M/S ROHIT CONSTUCTION (BID ID -3088653)
om suppler (BID ID -3084417)
ranjit singh (BID ID -3091052)
M/s Ray construction (BID ID -3081217)
M/S Bhushan Kumar Jain (BID ID -3091687)
M/S SHAMBHU SHARAN SINGH (BID ID -3084805)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .