Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC 19 PAOTA C ROAD JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹19.3 L+₹1.9 L (11.1%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹25.0 L+₹7.6 L (43.4%)Rejected-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹25.0 L+₹7.6 L (43.5%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹25.0 L+₹7.6 L (43.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
2 May 2022, 6:00 pmClosed
GE (AF) NO 2 JODHPUR
GE (AF) NO 2 JODHPUR
REPAIR/ SERVICING/ REWIRING OF PUMP AND ELECTRIC MOTORS AND ALLIED E/M WORKS TO WATER SUPPLY INSTALLATIONS UNDER AOR UNDER AGE E/M, GE (AF) NO 02 JODHPUR
2022_MES_516570_1
8307/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) No 2 Jodhpur
As per Tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) NO 2 JODHPUR
₹60,000
Yes
24 May 2022
5 Apr 2022
4 May 2022
7 Apr 2022
2 May 2022
19 Apr 2022
7 Apr 2022 - 8 Apr 2022
Amount
M&L for taking out of Elect Motor 75 HP Capacity installed as motor from foundation after disconnecting electrical connections, dismantling motor and rewinding the same with super enamelled copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts, reassembling and fixing the same in its original position including replacement of unserviceable nut-bolts, washer, lugs, terminal plate and making proper electrical connection complete all as specified and directed by Engineer-in-charge.Make of winding wire : - Devidayal / Chetak ,Note : - (i) Bearing if required for replacement shall be paid separately(ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account(ii) Transportation of motor is included in the unit rate of items nothing extra shall be paid on this account
All as per serial item No. 1 here-in-above but motor of capacity 50 HP
All as per serial item No. 1 here-in-above but motor of capacity 40 HP
All as per serial item No. 1 here-in-above but motor of capacity 20 HP
All as per serial item No. 1 here-in-above but motor of capacity 15 HP
All as per serial item No. 1 here-in-above but motor of capacity 10/12.5 HP
All as per serial item No. 1 here-in-above but motor of capacity 7.5 HP
All as per serial item No. 1 here-in-above but motor of capacity 5 HP
All as per serial item No. 1 here-in-above but motor of capacity 3 HP
All as per serial item No. 1 here-in-above but motor of capacity 2 /1 HP
Taking out centrifugal motor of any capacity from foundation, dismantling the motor, taking out rotor and filling the material by welding work, finishing by lathe machine, replacement of unserviceable bearing, reassembling the motor and fixed in its original position complete all as specified and directed by Engineer-in-charge.Note: - (i) Bearing shall be measured and paid for separately as “Supply only”(ii) New Nuts, bolts and washers if required for re-fixing the motor shall be provided by the contractor, nothing extra shall be paid on this account.
Supply only Ball Bearing of suitable size for rotor of motor 75 HP installed complete all as specified and directed by Engineer-in-charge.Make:-NBC / SKF / Tata.
All as per serial item No 12 here-in-above but for motor of 50 HP.
All as per serial item No 12 here-in-above but for motor of 40 HP.
All as per serial item No 12 here-in-above but for motor of 20 HP.
All as per serial item No 12 here-in-above but for motor of 15 HP.
All as per serial item No 12 here-in-above but for motor of 10 /12.5 HP.
All as per serial item No 12 here-in-above but for motor of 7.5 HP.
All as per serial item No 12 here-in-above but for motor of 5 HP.
All as per serial item No 12 here-in-above but for motor of 3 HP.
All as per serial item No 12 here-in-above but for motor of 1/ 2 HP.
Taking out defective centrifugal pump set , assembled with 75 HP electric motor, dismantling the pump set for carrying out repair / replacement of unserviceable parts such as CI impeller, Bush, ball bearing etc. reassembling, installing, commissioning and testing complete all as specified and directed by Engineer-in-charge.Note :(i) CI impeller, Bush & ball bearing required to replace shall be measured and paid for separately under respective items of BOQ as “Supply only”.(ii) The cost of transportation is included in the unit rate of this item nothing extra shall be paid on this account.
All as per serial item No 22 here-in-above but pump set assembled with 50 HP electric motor
All as per serial item No 22 here-in-above but pump set assembled with 20 HP electric motor
All as per serial item No 22 here-in-above but pump set assembled with 15 HP electric motor
All as per serial item No 22 here-in-above but pump set assembled with 10 /12.5 HP electric motor
All as per serial item No 22 here-in-above but pump set assembled with 7.5 HP electric motor
All as per serial item No 22 here-in-above but pump set assembled with 5 HP electric motor
All as per serial item No 22 here-in-above but pump set assembled with 2 /3 HP electric motor
Supply only ball bearing suitable for centrifugal Pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.Make : NBC / SKF / TATA
All as per serial item No 30 here-in-above but assembled with 50 HP Motor
All as per serial item No 30 here-in-above but assembled with 20 HP Motor
All as per serial item No 30 here-in-above but assembled with 15 HP Motor
All as per serial item No 30 here-in-above but assembled with 10 /12.5 HP Motor
All as per serial item No 30 here-in-above but assembled with 7 .5 HP Motor
All as per serial item No 30 here-in-above but assembled with 5 HP Motor
All as per serial item No 30 here-in-above but assembled with 3 HP Motor
Supply only CI impeller suitable for pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.
All as per serial item No 38 here-in-above but assembled with 50 HP Motor
All as per serial item No 38 here-in-above but assembled with 20 HP Motor
All as per serial item No 38 here-in-above but assembled with 15 HP Motor
All as per serial item No 38 here-in-above but assembled with 10/12.5 HP Motor
All as per serial item No 38 here-in-above but assembled with 7.5 HP Motor
All as per serial item No 38 here-in-above but assembled with 5 HP Motor
Supply only stainless steel Bush suitable for pump set assembled with 75 HP motor complete all as specified and directed by Engineer-in-charge.
All as per serial item No 45 here-in-above but assembled with 50 HP Motor
All as per serial item No 45 here-in-above but assembled with 20 HP Motor
All as per serial item No 45 here-in-above but assembled with 10 / 12.5 HP Motor
All as per serial item No 45 here-in-above but assembled with 7.5 HP Motor
All as per serial item No 45 here-in-above but assembled with 5 HP Motor
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 16 Sq mm 3 core complete all as specified & as directed by Engineer –in-charge.
All as per serial item No.51 here-in-above but 10 Sq mm 3 core.
All as per serial item No.51 here-in-above but 6 Sq mm 3 core.
All as per serial item No. 51 here-in-above but 4 Sq mm 3 core.
S&F as in replacement coupling assembly as per existing model & make suitable for centrifugal pump set assembled with 75 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 55 here-in-above but assembled with 50 HP motor
All as per serial item No. 55 here-in-above but assembled with 20 HP motor
All as per serial item No. 55 here-in-above but assembled with 15 HP motor
S&F in replacement rubber coupling as per existing model & make suitable for centrifugal pump set assembled with 75 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 59 here-in-above but assembled with 50HP motor
All as per serial item No. 59 here-in-above but assembled with 20/30HP motor
All as per serial item No. 59 here-in-above but assembled with 15/10/7.5 HP motor
All as per serial item No. 59 here-in-above but assembled with 5 HP motor
S&F in replacement Bakelite sheet of connection plate with cable connector suitable for 75 / 50 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 64 here-in-above but suitable for 20 / 12.5 /10 HP motor
S&F in replacement cooling fan with locking aluminium cast type screw, as per existing type, suitable for 75 / 50 HP motor complete all as specified & as directed by Engineer –in-charge.
All as per serial item No. 66 here-in-above but suitable for 25 / 20 / 12.5 HP motor
All as per serial item No. 66 here-in-above but suitable for 10 / 7.5 HP motor
All as per serial item No. 66 here-in-above but suitable for 5 HP motor
S&F gland rope of size 10 sq mm or as required complete all as specified & as directed by Engineer –in-charge
M&L for taking out defective submersible pump set of capacity 5 / 7.5 HP Capacity from bore well after disconnecting electrical connections, transportation to workshop for repair, dismantling the pump set for detection of repair such as rewinding of motor, replacement of iron strainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key, thrust bearing, replacement of unserviceable nut-bolts, washer, lugs, terminal plate, reassembling, lowering in well in its original position, making proper electrical connections, commissioning & testing complete all as specified and directed by Engineer-in-charge. Note : - (i) Cost for transportation to workshop and carry back to site after repair is included in the unit rate of item nothing extra shall be paid on this account.(ii) Rewinding of submersible motor, Iron strainer, bronze impeller, gun metal bushes stainless steel sleeve, impeller key and thrust bearing if required for replacement shall be paid separately against respective items of BOQ as "Supply only".(iii) Lathe work and grinding of shaft if required shall be paid separately against respective items of BOQ.(iv) Cost of new nuts, bolts, washers, lugs and terminal plate required to be replaced is included in the unit rate of this item nothing extra shall be paid on this account(iv) Cost of new nuts, bolts, washers, lugs and terminal plate required to be replaced is included in the unit rate of this item nothing extra shall be paid on this account..
All as per serial item No. 71 here-in-above but submersible pump set of capacity 10 / 12.5 HP
M&L for rewinding of submersible pump set of capacity 5 / 7.5 HP with PVC insulated copper winding wire of existing gauge including varnishing, baking, cotton tape and greasing of bearings, bushes and other connected parts complete all as specified and as directed by Engineer –in-charge Make of winding wire : - Devidayal / Chetak
All as per serial item No. 65 here-in-above but submersible pump set of capacity 10 / 12.5 HP
Supply only Iron strainer suitable for submersible pump of capacity 5 /7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Iron strainer suitable for submersible pump of capacity 10/ 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Bronze impeller suitable for submersible pump of capacity 5 / 7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Bronze impeller suitable for submersible pump of capacity 10 / 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for submersible pump of capacity 5 / 7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Gun metal Bush suitable for submersible pump of capacity 10 /12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Stainless steel sleeves suitable for submersible pump of capacity 5 /7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Stainless steel sleeves suitable for submersible pump of capacity 10 /12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Impeller Key suitable for submersible pump of capacity 5/ 7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Impeller Key suitable for submersible pump of capacity 10 / 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Thrust bearing (Gun metal) suitable for submersible pump of capacity 5 /7.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Supply only Thrust bearing (Gun metal) suitable for submersible pump of capacity 10 / 12.5 HP, 6 stage complete all as specified and as directed by Engineer –in-charge.
Grinding shaft of submersible pump of capacity 5 / 7.5 HP, 6 stage with grinding machine complete all as specified and as directed by Engineer –in-charge.
Grinding shaft of submersible pump of capacity 10 / 12.5 HP, 6 stage with grinding machine complete all as specified and as directed by Engineer –in-charge.
S&F in replacement contactor ML-2, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge.
S&F in replacement contactor ML-3, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, 50 Hz of AC3 Rating 70 Amps and AC1 Rating 110 Amps complete all as specified and as directed by Engineer –in-charge.
S&F in replacement contactor MNX80, 3 phase 415 volts having auxiliary contracts suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge.
S&F in replacement contactor MNX110, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge.
S&F in replacement contactor MCX 44, 3 phase 415 volts having auxiliary contracts 2 NO + 2 NC suitable for coil voltage 110 V, 220, 240 & 415 volts, complete all as specified and as directed by Engineer –in-charge.
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1, including internal wiring with 1.0 sq mm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm, single phase, as suitable range, class -1, including internal wiring with 1.0 sqmm single core PVC wire etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement overload relay, suitable for 10 HP to 40 HP motor, 3 phase, 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement overload relay, suitable for 50HP to 75 HP , motor 3, phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 15 HP pump set, 3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 20 HP pump set ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 50 HP pumpset ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in soft starter, suitable for 75 HP pump set ,3 phase 415 volt, 50 Hz as per sample complete all as specified and as directed by Engineer –in-charge.
S&F in replacement fully automatic star delta starter type ML2 FASD having relay of range 20 - 32 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
S&F in replacement fully automatic star delta starter type ML3 FASD having relay of range 28 - 42 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
S&F in replacement DOL starter range 13 - 22 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
S&F in replacement DOL Starter range 28 - 42 Amp including making electrical connection complete all as specified & as directed by Engineer-in-charge
S&F in replacement single phase preventer type SDz5, SPPR + Timer, 415 V including necessary copper connection, lugs etc complete all as specified & as directed by Engineer-in-charge
S&F in replacement electronic timer type ET100, 110 / 240V, 50 HZ including necessary electric connection complete all as specified & as directed by Engineer-in-charge
S&F in replacement on / off switch (push button) complete all as specified & as directed by Engineer-in-charge
S&F in replacement indicating lamp with holder and cover as per existing complete all as specified & as directed by Engineer-in-charge
S&F in replacement of slip ring drum suitable for 2 HP to 5 HP motor of flocculate as per sample complete all as specified & as directed by Engineer-in-charge
S&F in replacement of carbon bush suitable for 2 HP to 5 HP motor of flocculate as per sample complete all as specified & as directed by Engineer-in-charge
S&F in replacement MCCB 4 Pole 63 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 114 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt
All as per item No. 114 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 25 KA, 415 Volt
All as per item No. 114 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt
All as per item No. 114 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt
S&F in replacement Changeover switch 630 Amps, making necessary work, metal work for fixing etc and connections complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing as in repair cast iron body Foot valve of size 80mm bore ISI marked with IS 4038 with flanged ends and drilled, with neoprene rubber gasket joint and nuts bolts (high tensile) washers etc complete including testing all as specified.
All as per item No. 120 here-in-before but size of 100mm
All as per item No. 120 here-in-before but size of 150mm
Supply and fixing as in repair non return valves of size 80mm bore, cast iron body, as per IS 5312, heavy duty, both ends flanged and drilled, including nuts, bolts, washer and neoprene rubber gasket joint complete all as specified and as directed.
All as per item No. 123 here-in-before but size of 100mm
All as per item No. 123 here-in-before but size of 150mm
Supply & fixing as in repair cast iron sluice valve Long body of 80 mm bore,class 1.6, ISI marked with IS 14846 – 2000 with flanged ends and drilled, stainless steel spindle, CI gate with brass ring and iron wheel handle, cast iron cap, complete with neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, complete including testing all as specified.
All as per item No. 126 here-in-before but size of 100mm
All as per item No. 126 here-in-before but size of 150mm
All as per item No. 126 here-in-before but size of 200mm
M&L for Preparation of old painted steel surfaces of panel body of any size incl scrapping old paint, denting and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of Elect motor with pump including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of pipeline of dia 80mm to 150mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing paint of pipeline of dia 200mm to 350mm, including base frame and applying two coats of spray paint using synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F in repair fan belt B-32 of air compressor. The fan belt B-32 shall be ISI marked best quality and shall be approved by GE before incorporation in the work complete all as specified and directed by Engineer-in-charge.
Supply and filling compressor oil CG 100 complete all as specified and directed by Engineer-in-charge.
Supply and laying in repair rubber mat of size 2 m x 1 m x 19mm thick complete all as specified and directed by Engineer-in-charge.
Supply and fix water pressure gauge of pressure range 0-10 kg/Sqcm complete all as specified and directed by Engineer-in-charge.
Supply and fix water pressure gauge of pressure range 0-15 kg/Sqcm complete all as specified and directed by Engineer-in-charge.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 90 W LED, complete pre wired, including suitable bracket for fixing light on wall or any indicated location all as specified and as directed.
Supplying and fixing /connecting for service connection/garden light connection, 1100 volts grade heavy duty cable PVC insulated aluminium malty stranded conductor, twin core cable circular of sizes 6 sq mm 2 core complete all as specified and directed by Engineer-in-charge.
M & L for Earthling complete , excavation, testing etc ,with copper plate of size 60 cm ×60cm.× 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion
M&L for Construction of brick masonry in ,valve pit Type 'B' of size 90cm x 90cm x 60cm (internal dimensions of chamber ) made with sub class 'B' old size clay bricks compressive strength not less than 75 Kg/Sq cm in cement mortar 1:6 for sluice valve ,with C.I wheel (with direction marking ) and MS sheet 3.15 mm thick with handle ,locking arrangement and one no. brass padlock 65mm etc. PCC type B1 (1:2:4 with 20mm Graded stone Aggregate) necessary excavation ,foundation concrete in PCC 1:3:6 type C1 (20 mm Graded Stone aggregate ) and inside plastering with cement mortar 1:4 12 mm thick finished with a floating coat of neat cement PCC coping type B1 (1:2:4 with 20 mm Graded Stone aggregate ) ,MS angle iron of size 40mm x 40mm x6mm complete as specified and shown on drawing No. BTD em -082 sheet 1/2 & 2/2
All as per item No. 126 here-in-before but size of 100x 100 x 80 cm
All as per item No. 126 here-in-before but size of 150x 150 x 90 cm
S&F in replacement double headed hydrant valve complete all as specified and directed by Engineer-in-charge.
S&F in replacement fire hose 15 mtr long with male and female coupling complete all as specified and directed by Engineer-in-charge.
S&F in replacement 19mm dia hose reel complete all as specified and directed by Engineer-in-charge.
S&F in replacement branch nozzle complete all as specified and directed by Engineer-in-charge.
S&F in replacement 80mm dia butterfly valve complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 149 above but 100 mm dia bore.
All as per Srl item No 149 above but 150 mm dia bore.
S&F in replacement Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside Yard.
M/s Bakiyalakshmi Enterprises
M/s. Dhananjay Construction
Siddharth Constructions
M/S SHREE AAINATH ENTERPRISES
Nvimal Engineers and Contractor
M/S RAKESH CHOUDHARY
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .