Director
NIT, Calicut, Kerala - 673601
Providing additional light, fan, exhaust fan, power plug points and industrial socket including providing UPS points at SMGO research lab room no. 213 in Chemistry department
2020_NITC_602588_1
EMU1/SMGO Chemistry/2020-21/11
Open Tender
Electrical Works
Item Rate
20 days
Calicut
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
Director, NITC
₹2,300
Yes
21 Oct 2021
11 Dec 2020
6 Jan 2021
11 Dec 2020
4 Jan 2021
11 Dec 2020
90 days
Amount
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing of 20 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing 3 numbers 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 2.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 4 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black and Green) in the existing surface / recessed PVC conduit as required.
Wiring for circuit/ submain wiring alongwith 4 X 10 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing 20 amps.240 volts, SPN industrial type,socket outlet,with 2 pole and earth,metal enclosed plug top alongwith 20 amps "C" curve,SP MCB, in sheet steel enclosure,on surface or in recess,with chained metal cover for the socket outlet, complete with connections, testing and commisioning as required.
Supplying and fixing 6 - 32 A rating, 240/415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of 4 way (8 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Diamond Engineering Works
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .