| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹26.0 L+₹51,525 (2.02%)Rejected-Finance 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | L2 | Rejected-Finance rejected being L2 | |
| 3 | L3₹27.3 L+₹1.8 L (7.18%)Rejected-Finance 300 GOPAL NIWAS 3 A ROAD SARDARPURA JODHPUR CITY RAJASTHAN 342003 | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-Finance rejected being L3 | |
| 4 | L4₹28.5 L+₹3.0 L (11.9%)Rejected-Finance | L4 | Rejected-Finance rejected being L4 | |
| 5 | L5₹31.0 L+₹5.5 L (21.6%)Rejected-Finance 10 SUBASH COLONY DEFENCE LAB ROAD RATANDA JODHPUR 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L5 | Rejected-Finance rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹59,000
Closing Date
23 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Army) Central Jodhpur
GE (Army) Central Multan Line Army Area Jodhpur
SPL REPAIR AGAINST BER AC S AT SOUTHERN COMD WARCEN AT JODHPUR UNDER GE ARMY CENTRAL (9089/E8)
2022_MES_515923_1
GE/J/A- OF 2021-22 (9089/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (Army) Central Jodhpur
₹59,000
9 May 2022
31 Mar 2022
25 Apr 2022
31 Mar 2022
23 Apr 2022
9 Apr 2022
60 days
Amount
Note:- 1. All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are required to quote their rates accordingly.
Taking down carefully Old U/S ductable Split AC of Capacity 7.6 Ton and 5.5 Ton including Copper Duct b/w Outdoor and Indoor uinits, Drainage pipe, etc transporting to AGE E/M store Yard deposited to store, complete all as directed by Engr-in-charge.
Supply, installation, Testing and Commissioning of New Ductable Split Air Conditioner of Capacity 7.6/8.5 Ton or Nearest higher size available complete with blower section with motor and drive, DX coil, motor mated hermatically sealed Scroll Compressors, centrifugal blower for evaporator, filter and thermostatic control , all the items enclosed in an attractive sheet metal cabinet, complete all as specified and as directed. Make : Blue Star/ O.General/ Daikan Note :- DETAILED TECHNICAL SPECIFICATIONS OF DUCTABLE MACHINES IDU for 8.5 TR M/C: Normal cooling capacity : 102000 Btu/Hr. Nominal Air Quantity : 3400 CFM Fan type : Direct driven DIDW forward curve centrifugal blower. Fan quantity : 2 nos. Fan Discharge : Horizontal/Vertical. No. of fan motor : One. Control Type : microprocessor LED display. ODU for 8.5 TR M/C: Number ODU : One. Normal cooling capacity : 102000 Btu/Hr. Nominal Air Quantity : 3400 CFM Fan type : Centrifugal Fan Fan quantity : 1 no. Fan Discharge : Horizontal/Vertical. No. of fan motor : one. Compressor Type : Scroll
All as per item No. 3 above but of capacity 5.5 Ton Note :- DETAILED TECHNICAL SPECIFICATIONS OF DUCTABLE MACHINES IDU for 5.5 TR M/C: Normal cooling capacity : 66000 Btu/Hr. Nominal Air Quantity : 2200 CFM Fan type : Direct driven DIDW forward curve centrifugal blower. Fan quantity : 2 nos. Fan Discharge : Horizontal. No. of fan motor : One. Control Type : microprocessor LCD display. ODU for 5.5 TR M/C: Normal cooling capacity : 66000 Btu/Hr. Nominal Air Quantity : 2200 CFM Fan type : Centrifugal Fan Fan quantity : 1 no. Fan Discharge : Horizontal. No. of fan motor : One. Compressor Type : Scroll (Copeland Make)
SITC of Copper Refrigerant piping of appropriate size (suction & liquid) for item srl Nos. 3 & 4 above, complete all as specified and as directed.
Toping of Refrigerant Gas for ductable units in Ser No 3 & 4 above, complete all as specified and as directed.
Supply, Installation of Microprocessor based Communiocation cable interconnecting outdoor unit to indoor unit, complete all as specified and as directed.
Supply, laying, fixing, testing & commissioning of drain pipes with 6 mm thick nitrile rubber tube insulation complete with all necessary fittings such as elbows, tees, reducers etc and supports such as U-clamps etc., , complete all as specified and as directed.
Supply, installation, testing of site fabricated sheet metal retangular ducting wih all supports hangers, vanes, etc.,, complete all as specified and as directed.
Shree Karni Electrovision
UTSAV INDIA LIMITED
Mahesh Dave
Panwar Electricals
Harsh Enterprises
S.G.ENGINEERING COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .