Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | ₹10.4 L Quoted ₹11.1 L | L1 | Accepted-AOC Due to lowest accepted |
| 2 | L2₹13.3 L+₹2.2 L (19.4%)Rejected-Finance | ₹13.3 L+₹2.2 L (19.4%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹15.2 L+₹4.1 L (37.2%)Rejected-Finance | ₹15.2 L+₹4.1 L (37.2%) | L3 | Rejected-Finance Other than lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
5 Jan 2023, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001
REPAIR / MAINT OF SEWAGE PUMP AND MISC E/M WORKS AT DHOLEWAL CG COMPLEX DORAHA AND PHILLAUR UNDER GE LUDHIANA
2022_MES_558532_3
GE/LDH-55/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Dholewal CG Complex Doraha and phillaur
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,000
Yes
9 Feb 2023
16 Dec 2022
6 Jan 2023
16 Dec 2022
5 Jan 2023
23 Dec 2022
16 Dec 2022 - 22 Dec 2022
Amount
Excavation in trenches n. exc 1.5 metre wide for taking out/ laying pipe line etc. and not exceeding 1.5 metre deep and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed by Engineer-in-charge.
Removal of excavated surplus spoil to a distance n.exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed by Engineer-in-charge.
Supply and fixing in replacement of cast iron sluice valve suitable for 100mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed.
Supply and fixing in replacement of cast iron sluice valve suitable for 80mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed.
M&L for removing rewinding and refixing of sewage disposal motor capacity of 5.5 HP at sewage installation, opening of motor,cutting removing old burnt winding coils ,cleaning filling the starter slots necessary mechanical works for shaft/bearing housing/mechnaical seal/volute/ volute base, greasing/oiling all moving parts , rewinding with suitable gauge of super enamelled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing/replacement of pump including replacement of spares , lifting eye bolt, cable gland, protection tube, cable seal, terminal board, cable bracket, brearing cover, double mechanical seal,tie for stand,support bracket, guide shoe, moisture sensor, potting cup, Gland iron box,S & F Duck foot bend, hose clip ball bearings, thermal over load protector, hose nipple, shaft bleaching, two coats of synthetic enamel spray painting on body , suitable mains connections from coil to terminal box,preparing and inserting coil running/starting winding interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and for transportation, testing at site and satisfactorily running all as specified and directed . Note :- (a) Lifting the moter & lowering after reapir shall be arranged by the contractor without any extra cost. (b) Trnasportaion form site to workshop and back to site shall be included in quoted rates.
All as per srl item No 6 above but motor capacity 7.5 HP.
All as per srl item No 6 above but motor capacity 10 HP.
All as per srl item No 6 above but motor capacity 12.5 HP.
All as per srl item No 6 above but motor capacity 1.0 HP.
All as per srl item No 6 above but motor capacity 2.0 HP.
All as per srl item No 6 above but motor capacity 3.0 HP.
Supply and fixing for MS coupling with rubber bush 4 mm thick and coupling nuts, blots/washers for 5.5/7.5/10 HP non clog pumping set complete as per sampe and directed by EIC.
M&L for lifting of Submerible type sewage pump ,capacity 10/ 7.5/5 HP and cleaing/removal of waste or chocking material, lowering after making serviceable , complete all as specified and directed by EIC. Note:- Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 40 feet lifting arrangement portable type ) and other lifting arrangement shall be deemed included in quoted rate (b) Minor repair shall be made and including in quoted rates.
M & L for Automatic water level controller (ACES 3 Phase) For Monoblock / submersible type Sewage Pumps suitable for Underground Sewage sump for control the water disposal. All the accessories should be fitted in powder coated cabinet, Pump auto /start stop by float sensor grade “A” (Sulphate and maintenance free) it will work 24x7 opertion facility as as specified and directed and also, testing of (STP) treated water samples for NABL accredited lab for following parameters and submitting the results to MES complete all as specified and directed by Engr-in-Charge:- (a) PH (b) BOD (c) COD (d) TSS (e) Fecal coliform
M & L for flat iron clamp 0.75/1.00 mtr long of size 100mm x 10 mm thick made out of MS suitable for 80/100 mm bore GI pipe with complete nuts, bolts and washer etc.
Supply Only First Aid Kit box No-08 made of Stainless steel (Size : 360 mm x 150 mm x 80 mm) caintaining following items. (a) Dettols bottle100 ml 02 bottles (b)Antiseptic Ointment 100 mg © Crocin tabletes 01 strips ( containings 10 Tablets each). (d) Hydrogen peroxide 50 ml 01 bottle (e) Cotten small rolls 2 Nos (f) Cotten strip small roll 04 Nos (g)Moov tube 01 Nos (h) Betadine Tube 100 mg (j) Bendaid -05 Nos
Supply only LT insulation tape size 25mm width Appx 30 Mtr length.
M & L for in replacement of NRV 80 mm horizontal type made of MS with brass sheet fitted complete all as specified and directed.
M & L for in replacement of NRV 100 mm horizontal type made of MS with brass sheet fitted complete all as specified and directed.
Bailing out sludge water from sludge tank/sewage sump by using pumping set/mechanical suction and disposing off the same not less than 500 metres away from site.
Bailing out mud/sludge from sewage tank/sump by using any mechnaincal means/ sewer suction cum jetting machine and disposing off the sludge at the bottom of the tank & thrown away upto 500 metres away from site complete as specified and directed by Engr-in-Charge Note:- Skilled supervisor shall be deputed on site by the contractor during sump cleaning & included in quoted rates.
M& L for Preparation and priming of old and new surface and applying two coats of alkeli resistant paint over the treated surface.
S & F in replacement direct online starter 3 phase , 415 volt , (DOL) in S/S housing with magnetic,thermal overload relay range 10 to 16 Amp complete suitable for electric motor 15 HP. Make : Siemen/L&T/Havells/ C & S/ Indo Asian
All as per srl item No 24 above but suitable for 10 HP motor.
All as per srl item No 24 above but suitable for upto 5.5 HP motor.
Supply and replacement of 1100 volts grade heavy duty PVC insulated flat submerssible cable 10 sqmm, 3 core with copper conductor complete.
Supply and replacement of 1100 volts grade heavy duty PVC insulated flat submerssible cable 6 sqmm, 3 core with copper conductor complete.
Supply and filling hypochloride solution Gde I conforming to IS 11673-1992 having 10 to 15% active liquid chlorine
S & F in replacement aluminium strip of size 25mm x 3 mm with new saddle and fixing screw for roof conductor/down conductor above ground.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F for over load relay 0 to 63 Amps 415 V.
S&F for Contactor ML-3 415V as per existing rating .
S&F for single phase preventor VSP-3 .
S & F for voltmeter 0 to 500 Volt 96 x96mm square 415 volt.
S & F for ampre meter 0 to 200 amp 96x96mm with CTs square.
S&F in replacement of phase indicating lamp complete.
S&F for rubber packing 3.0 mm thick with nut bolt washer consisting of 8/6/4 hole for 80mm to 100mm column pipe complete all as specified and directed.
M&L for cutting and removing the existing rusted flange of coloumn pipe and refix new flange pipe dia 100 mm 3 metres long including cutting of coloumn pipes threading and welded with 2 Nos heavy duty flange, tee, bend , elbow flanged (not less than 12mm thick) duly drilled with cable slot all as directed.
M&L for cutting and removing the existing rusted flange of coloumn pipe and refix new flange pipe dia 80 mm 3 metres long including cutting of coloumn pipes threading and welded with 2 Nos heavy duty flange, tee, bend , elbow flanged not less than 12mm thick duly drilled with cable slot all as directed.
M & L for suction pipe line 100mm bore GI heavy grade with double ends flanged, 4 hole for sewage pump complete with nut bolt and gasket as specified and directed.
M & L for suction pipe line 80mm bore GI heavy grade with double ends flanged, 4 hole for sewage pump complete with nut bolt and gasket as specified and directed.
Supply and Fix for MCCB 125 Amp, 415 V, 16 KA, 4 pole with adjustable thermal magnetic release complete all as specified & directed. Make: L&T/Indoasian/Havells
Supply and Fix for MCCB 100Amp, 415 V, 16 KA, 4 pole with adjustable thermal magnetic release complete all as specified & directed.Make: L&T/Indoasian/Havells
Supply and Fix for off load Changeover Switch 100 A, 4P 415 V with enclosure complete all as specified and as directed by engr in-charge.Make: L&T/Indoasian/Havells
Supply and Fix for off load Changeover Switch 63 A, 4P 415 V with enclosure complete all as specified and as directed by engr in-charge.Make: L&T/Indoasian/Havells
Supply and fixing for LED building security lights to be installed at pump house building or OHT of 25 watt with power factor 0.95 (minimum) epoxy powder coated pressure die-cast aluminium housing watt standard size, heat resistant toughened clear glass/transperent polycarbonate sheet, electronic driver in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening with IP-65/66 or above complete all as specified and directed. Note :- fixing clamp/bracket and connecting wire 0.5 sq mm of 1.5 mtr length shall be deemed in quoted rate.
M&L for earthing complete for LT Panels/ Feeder Pillars with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm and including GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 5 of SSR Part-I (2009) testing on completion complete all as specified. Note : 1. If result is not satisfactory then contractor will do the on other location without any extra cost.
Supply and fixing for isolator TPN 40 A, 415 V, 16 KA all as specified and directed.
Supply and fixing for isolator TPN 63 A, 415 V, 16 KA all as specified and directed.
S&F for mild steel bolts purpose made with hexagonal orsquare head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long dia of neck is not exceeding 12 mm as specified and as directed.
Excavation in post holes (or similar holes ) each n.exc 0.50 Cum, and getting out, returning filing in and ramming earth with broken rubble mixed with earth around in layers n.exc 25cm, watering etc and removing surplus soil n.exc 50m and making good surface in loose/soft soil complete all as specified and directed.
M&L for plain cement concrete 1:4:8 Type D 2 (using 40 mm graded aggregate ,in foundations, filling and mass concrete complete all as specified and directed.
S & F for mild Steel flats iron fillets for securing chain link fencing & including all necessary drilling holes, bolting or riverting etc and similar work conforming to Fe-410 Gde Fe-310 complete all as specified.
Supply only chain link MS galvanised fencing, heavy zinc coated (Hot Dip) of 4mm nominal dia of wire and mesh of size 100mm x 100mm conforming to IS: 2721-2003 complete all as specified in clause 10.34 on page 214 & 2015 of MES SSR - 2009 Part 1 and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire/MS rods, complete all as specified and directed by EIC.
S&F for TMT bar 10mm dia and over cut to length bent to shapes requried including cranking bending etc conforming to IS grade Fe-410-W for tying wire mash/chain linked fencing complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and dia meter of shank 5mm to 10mm complete all as specified.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conf to Fe-410-w or E -250 quality A complete all as specified and directed.
S&F for 4mm dia galvanised steel wire 150x100mm mesh,made up into mattresses or cages, lapped, wired and laid/weld in position incl closing after filling as in repairs.
S&F for mild steel butt hinges cold rolled of size 75mm medium weight.
Demolition of brickwork or stone/ boulder masonary, built in lime motor incl all quoins, arches, pillers etc. of any description and in any position, removing demolished material from site, complete all as specified.
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius and built in cement morter 1:4 as in repair/raising /making of valve pit chamber/sewage pits complete all as specified.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces with CM 1:4 complete all as specified.
Demolition of plain cement concrete of any description and in any position, removing demolished material from site, complete all as specified.
M & L for plain cement concrete (PCC) 1 : 2 :4 type B2 using 40mm stone aggregate, as in repairs to Valve pits / disturbed hard standing/ road or any other repair as required at site at any situation all as specified as directed.
M&L for preparing new plastered surfaces and applying three coats of white wash complete all as specified.
M&L for prepation new painted metal surfaces of any description, over 10cm in width or girth and appling two coat of synthatic enamil paint of approved tint .
M&L for preparing old steel surfaces and applying two coats of synthetic enamel paint over a coat primer, complete all as specified and as directed.
M&L for cleaning, grass cutting and removing of dust, raw materials of sourrounding area of installation/ overhead tank,panels complete all as specified and directed.
M & L for Writing letters or figures (Block.Roman, Italic or Indian) not exc. 30 cm high complete all as specified and directed. Note:- Rough data to write shall be provide by department.
Supply only aluminum lug for cable termination as specified for following sizes:- 6 Sq mm to 70 Sq mm
S& F in replacement of heavy duty portable chain pulley block 10 ton capacity with 3 mtr lifting of 75 kg weight, complete all as specified and as directed,
Taking down of XLPE insulated heavy duty electric cable with aluminium conductor 1100 Volt garde cross sectional area is any type and any size Note :- Earth work will be measured separtealy.
S&F for XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 25 Sqmm 3.5 core.
S&F for XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 16 Sqmm 4 core.
Supply and spreading of fine river sand and gentally punning for laying of under ground cables. Note :- Punned thickness 18cm shall be measured for payment.
Supply and laying for sub class 'B'common burnt bricks, old size designated 75, laid dry flat with width equal to length of brick & with gaps between the adjucent bricks n.exc 10mm as cover laid over the cable to give mechanical protection to under ground cable complete.
R K ENTERPRISES
shri ram enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .