GE 969 EWS
GE 969 EWS C O 56 ASP
REPAIR MAINT OF LT OH LINE LT PANEL BOARD AND CONNECTED ITEMS AT BARAMULLA KITCHAMAKHANPURA AND PATTAN UNDER GE 969 EWS
2019_MES_268910_2
969/WS/ /2019-20
Open Tender
Civil Works
Item Rate
180 days
Baramulla Pattan
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹50,000
Yes
7 Feb 2020
10 Oct 2019
4 Nov 2019
10 Oct 2019
2 Nov 2019
21 Oct 2019
Amount
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of any type soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line. Complete all as specified and directed by Engineer-In-Charge.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point Complete all as specified and directed by Engineer-In-Charge.
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm Complete all as specified and directed by Engineer-In-Charge.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable Complete all as specified and directed by Engineer-In-Charge. (Note:-Only pund thickness will be measured and paid.)
M&L for Sub class "B" bricks laid dry width wise across the line of cable in trenches as cable protection Complete all as specified and directed by Engineer-In-Charge.
Supply & laying in replacement of UG cable LT 1100 volts grade XLPE insulated armoured heavy duty electric cable confirming to IS-7098 (pt-1) 1988 with stranded aluminium conductor of cross section area 185 Sqmm 3.5 core laid in trenches or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing. Complete all as specified and directed by Engineer-In-Charge.Make: Polycab/Finolex/KEI /Universal .
All as per item No 6 above but of size 150 sqmm 3.5 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of sizer 120 sqmm 3.5 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 95 sqmm 3.5 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 70 sqmm 3.5 core.Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 50 sqmm 3.5 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 35 sqmm 3.5 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 25 sqmm 3.5 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 16 sqmm 4 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 16 sqmm 2 core. Complete all as specified and directed by Engineer-In-Charge.
All as per item No 6 above but of size 10 sqmm 2 core. Complete all as specified and directed by Engineer-In-Charge.
S&F in replacement of MCCB 415 Volt 16 KA, 4 Pole 63 Amps capacity. Complete all as specified and directed by Engineer-In-Charge. Make:ABB/Siemens/Hager.
All as per item No. 17 above but 100A, 25KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 17 above but 125A, 35KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 17 above but 160A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 17 above but 200A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 17 above but 250A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 17 above but 315A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
All as per item No. 17 above but 400A, 36KA. Complete all as specified and directed by Engineer-In-Charge.
Dismentling old and unsv stay assy complete comprising of stay clamp, stay wire, stay insulator, stay grip, thimble, bow, stay rod 16 mm dia and stay plate etc including breaking of cement concrete Complete all as specified and directed by Engineer-In-Charge.
M&L for stay assembly complete with accessories as shown in electrical plate No 1 ( Loop type insulator, stay clamps excavation and concrete measured separately)stay rod 20mm dia Complete all as specified and directed by Engineer-In-Charge.
M&L for replacement of Galvanised stay strand wire of size 7/4mm. Complete all as specified and directed by Engineer-In-Charge.
M & L for cement concrete for foundation fillings and mass conctere type D2 1:4:8 using 40 mm graded aggregate Complete all as specified and directed by Engineer-In-Charge.
M & L for cement concrete in coping of poles using B1 1:2:4, 20 mm graded aggregate, smooth finishing without using extra cement Complete all as specified and directed by Engineer-In-Charge.
M & L for cement concrete in foundation fillings and mass conctere type C2 1:3:6 using 40 mm graded aggregate Complete all as specified and directed by Engineer-In-Charge.
Dismantling old and unsv prestressed concrete poles/steel tublar poles of any type including breaking cement concrete complete and site clearance. Complete all as specified and directed by Engineer-In-Charge.
S&F steel tublar swaged pole 9.0 meters long complete erection with cast iron base plate finial taper plug , bolts nuts and screws as specified type 410 SP-31 Complete all as specified and directed by Engineer-In-Charge. Make:-Jindal Steel Product /Bharat Conduit & Steel works Kanpur /Zain Industries Srinagar .
Dismantling carefully steel poles/struts, any size including bracking of PCC, disconnecting all cable connection, cross arm, etc and keeping aside for reused with in 50m and relocating the same pole where directed.Complete all as specified and directed by Engineer-In-Charge. (Note : Earth work,PCC work and coping of pole will be measured and paid separately in the relevant items.)
M&L for painting to existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers. of 2 inches bold letters with black paint after painting, Complete all as specified and directed by Engineer-In-Charge.
Supply and laying GI pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one. Complete all as specified and directed by Engineer-In-Charge.
Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one. Complete all as specified and directed by Engineer-In-Charge.
Supply and laying GI pipe 40 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one. Complete all as specified and directed by Engineer-In-Charge.
Dismantling and removal of ACSR conductor any size from the pole and restringing/refixing the same with insulator including replacement of binding wire chopping of trees branches (coming in the way/line) Complete all as specified and directed by Engineer-In-Charge.
Dismantling of ACSR of any size from pole, cross arms, insulators, etc .Complete all as specified and directed by Engineer-In-Charge.
S&F in repair ACSR conductor of (weasel) 6/1 X 2.59mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc.Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of lugs or thimbles suitable for 25 sqmm to 70 sqmm aluminum conductor cable.Complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of lugs or thimbles suitable for 95 Sqmm to 185 sqmm aluminum conductor cable. Complete all as specified and directed by Engineer-in-Charge.
Dismantling /disconnecting & taking down insulaters of any size & capacity.Complete all as specified and directed by Engineer-in-Charge.
M&L for pin type porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 100 mm dia for 1100 volts grade. Complete all as specified and directed by Engineer-in-Charge.
S & F in repair cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one finishing coat of aluminum paint over one primer coat of red oxide zinc chrome,Complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC spacer suitable for 4 wire LT OH line Complete all as specified and directed by Engineer-in-Charge.
Repairs to panel board indoor type/out door type sheet metal approximate size (5 x 3 x 1.5 Feet's) tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws and painting the complete body with two coats of synthetic enamel paint over a coat of Zinc chrome primer Complete all as specified and directed by Engineer-in-Charge.
Earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to GI strip earth lead strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40 mm bore GI medium grade earth lead protection pipe,40 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 8 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed. ( Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type B2 in pit PCC Cover & other arrangement.) Complete all as specified and directed by Engineer-in-Charge.
M/s SONA ULLAH LONE AND SONS
M/S GHULAM QADIR WANI AND SONS
M/S Khan Hussain & Co.
M/S Sky Engineers
m/s mohd rafiq lone
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .