CONSTRUCTION OF 720 BEDDED Dr. BHIM RAO AMBEDKAR SC/ST RESIDENTIAL SCHOOL (10+2) AT RAMCHAK CHAPRA (SARAN).
138389
RENIT 04/SBD/2026-27
Open Tender
CIVIL
Saran
• 3. Technical -Qualification eligibility criteria:
[a] The Contracting Firm/Agency shall be a well established and reputed firm specialized in the trade and registered as a legal entity for a minimum period of Ten years and having experience and capacity in the execution of similar works;
• [b] The contracting Firm/Agency should have achieved during last five years in any one year a minimum annual financial turnover [in all classes of Civil Engineering Construction works only] of at least 50% (fifty percent) of the estimated cost of work, ending on 31st March 2026 . The annual turn over of previous years will be adjusted to 2025--2026 price level based on annual inflation of 8% (eight percent);
• [c] The contracting Firm/Agency should have satisfactorily completed as a Prime contractor during the last five years, ending MAY 2026
(i) Three similar works each costing not less than 40% (forty percent) of the estimated cost or completed two similar works each costing not less than 60% (sixty percent) of the estimated cost or completed one similar work costing not less than 80% (eighty percent) of the estimated cost.
ii) Similar nature of works means (i) construction of RCC framed Structure or Institutional building campus consisting of RCC framed Structure of Institutional buildings, Hostels including Internal Electrical & Plumbing works, Campus roads, External PHE works for State Govt. / Central Govt. PSU.
The completion certificate shall be issued by employer not below the rank of Executive Engineer or project manager. In case of private client the completion certificate issued by employer should be certified by the CA. The bidders shall have to also submit good quality digital photographs of the completed projects.
(iii) The contracting Firm/Agency should have adequate capacity of carrying out plumbing works and electrical works [through "1A CLASS" Electrical Contractor].
They should also indicate name of the specialized Fire fighting agency.
• [d] The contracting Firm / Agency should have to produce Bankers solvency certificate or Revenue solvency Certificate of Value not less than 40% of the estimated cost.
• [e] The contracting firm / Agency should have to produce evidence of access to lines of credit and availability of other financial resources facilities (10% of contract value), certified by the Bankers (Not more than 3 months old).
• [f] The Bidder shall furnish undertaking that would be able to invest a minimum cash upto 25% of contract values of work, during implementation of work.
• [g] The contracting Firm/Agency should not have incurred any loss in more than 2 years during the last five years ending 31st March 2026.
• [h] Joint Venture (JV) is acceptable as per annexure 1 of Tender document.
CIVIL
PERCENTAGE
L1
1
14 documents required · 14 mandatory
₹10,000
Processing Fee: 11800
₹66.1 L
SE CHAPRA, BCD AND C.E NORTH BCD PATNA
19 Aug 2026
19 Aug 2026
15 Sept 2026
19 Aug 2026
14 Sept 2026
19 Aug 2026
25 Aug 2026
BILL OF QUANTITY
BUILDING DIVISION CHAPRA
PROJECT: CONSTRUCTION OF 720 BEDDED Dr. BHIM RAO AMBEDKAR SC/ST RESIDENTIAL SCHOOL (10+2) AT CHAPRA, DISTT - SARAN
ESTIMATED COST:- ₹ 561,069,093.00 BOQ ISSUED TO:-
EARNEST MONEY:- ADDRESS:-
COST OF BOQ:- REG. NO.:-
TIME OF COMPLETION:- SIGNATURE OF ISSUING OF:-
DATE OF TENDER:-
SL no SOR Item of work Quantity Unit School Building Boy's Hostel Boy's PHE GIRLS's Hostel Girls's PHE B WALL G Prin. Cum Teachr.Qtr Prin. Cum Teachr PHE + Fire Staff Qtrs Staff Qtrs PHE B WALL Campus & Pathway Landscape & Horticulture External PHE Recharge Pit Desilting Chamber Septic Tank 5 Septic Tank 1 Septic Tank 1 No Under G Water Tank Ferniture Fire Fighting Badmintong School Building Boy's Hostel Boy's PHE Girl's Hostel Girl's PHE B WALL G Prin. Cum Teachr.Qtr Prin. Cum Teachr PHE + Fire Staff Qtrs Staff Qtrs PHE B WALL Campus & Pathway Landscape & Horticulture External PHE Recharge Pit Desilting Chamber Septic Tank 8 Septic Tank 1 Septic Tank 1 No Under G Water Tank Ferniture Fire Fighting Badmintong 1 2 3 4 5 Total
1 2.6 Earth work in excavation over areas (exceeding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m ; disposed earth to be levelled and neatly dressed. 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0
2 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth : consolidating each deposited layer by ramming and watering lead. 3167.49 cum 123.90 392451.41 1080.00 455.00 455.00 113.4986109 129.00 167.00 0.00 601.9865296 0 80 15 0 0 0 71.000 0 0 3167.49 133812.00 56374.50 0.00 56374.50 0.00 14062.48 15983.10 0.00 20691.30 0.00 74586.13 0 0 0 9912 1859 0 0 0 8796.900 0 0 0 392451.41 #REF! 0
4 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
5 4.12 Extra for Providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufactures. 26489.00 per 50 kg cement 57.16 1514111.24 308.00 10445.00 10445.00 5108.00 61.00 0.00 0 0 0 0 0 0 122.000 0 0 26489.00 17605.28 597036.20 0.00 597036.20 0.00 0.00 291973.28 0.00 3486.76 0.00 0.00 0 0 0 0 0 0 0 0 6973.520 0 0 0 1514111.24 #REF! 0
6 5.9.1 Centring and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc., for mass concrete. 2164.07 sqm 211.60 457918.06 119.00 265.00 265.00 180.916 150.00 52.00 0.00 978.818 146 0 0 0 0 0 0 7.000 0 0 2164.07 25180.40 56074.00 0.00 56074.00 0.00 38281.83 31740.00 0.00 11003.20 0.00 207117.89 30966 0 0 0 0 0 0 0 1481.200 0 0 0 457918.06 #REF! 0
10 5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete. 0.00 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
5.33.1.1 Providingandlayinginpositionreadymixedorsitebatcheddesignmix cement concrete for reinforced cement concretework; using coarse aggregateand fine aggregatederived fromnatural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures inrecommendedproportionsasperIS9103toaccelerateretardsettingofconcrete,toimprovedurabilityandworkabilitywithout impairingstrength; includingpumpingof concrete tositeof laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcementasperdirectionof theengineer-in-charge; for thefollowing grades of concrete 0.00 0.00 0.00 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
13.1 5.33a.1 roviding and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength andadmixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge. 25.78 cum 4756.90 122632.88 0.00 0.00 0 0 0 24 0.75 0.61 0 0 25.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 116163 3568 2902 0.000 0 0 0 122632.88 #REF! 0
17 6.3C Extra tor Brick work in superstructure above plinth level upto floor V cum 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
18 9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19 26.87.1 Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk 261.93 sqm 3866.50 1012757.37 48.93 0.00 180.00 33.00 0 261.93 189192.87 0.00 0.00 0.00 0.00 0.00 695970.00 0.00 127594.50 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 1012757.37 #REF! 0
20 26.86.2 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately). 372.98 mtr 768.10 286482.10 168.98 0.00 85.00 119.00 0 372.98 129789.70 0.00 0.00 0.00 0.00 0.00 65288.50 0.00 91403.90 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 286482.10 #REF! 0
21 9.96 Providing and fixing aluminium sliding door bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
22 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ), transparent or dyed to required colour or shade, with necessary screws etc. complete: 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
23 9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
24 9.1 Providing and fixing aluminium hanging floor door stopper anodized (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
25 9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to I.S. 2202 (part I). 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
26 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (overall area of door shutter to be measured) 712.08 Sqm 401.40 285829.03 160.92 150.00 150.00 188.16 63.00 0.00 0 0 0 0 0 0 0 0 712.08 64591.72 60210.00 0.00 60210.00 0.00 0.00 75529.11 0.00 25288.20 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 285829.03 #REF! 0
27 9.40 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs, and priming coat on unexposed surface etc. complete. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
28 9.136 Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately). 172.00 mtr 1462.70 251584.40 32.00 70.00 70.00 0.00 0.00 0 0 0 0 0 0 0 0 172.00 46806.40 102389.00 0.00 102389.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 251584.40 #REF! 0
29 9.137 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-incharge (panneling to be paid for separately). 75.00 sqm 6445.00 483375.00 15.00 30.00 30.00 0.00 0.00 0 0 0 0 0 0 0 0 75.00 96675.00 193350.00 0.00 193350.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 483375.00 #REF! 0
30 9.138 Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc.,with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-charge. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
31 9.147D.4 ProvidingandfixingfactorymadeuPVCwhitecolourslidingglazedwindowupto1.50m inheight dimension comprising of uPVCmulti-chamberedframewith in-built roller trackandsashextrudedprofilesduly reinforcedwith1.60±0.2mm thick galvanizedmild steel sectionmade fromrollforming process of required length (shape& size according to uPVCprofile),appropriatedimensionofuPVCextrudedglazingbeadsanduPV extruded interlocks, EPDMgasket, wool pile, zinc alloy (white powder coated) touch lockswithhook, zincalloybodywithsinglenylon rollers (weightbearingcapacitytobe40kg),G.I fasteners100x8mmsizeforfixing frame to finishedwall andnecessary stainless steel screws etc.Profileof frame&sashshallbemitredcutandfusionweldedatallcorners,includingdrillingof holes for fixinghardware'sanddrainageofwateretc.After fixingframethegapbetweenframeandadjacent finishedwall shal befilledwithweatherproofsiliconsealentoverbacker rodof requiredsiz andofapprovedquality,allcompleteasperapproveddrawing&direction ofEngineer-in-Charge.(Single/doubleglasspanes,wiremeshandsilicon sealent shall be paid separately Note:ForuPVCframeandsashextrudedprofilesminus5%tolerance in dimension i.e. in depth & width of profile shall be acceptable. 1548.05 sqm 9083.30 14061425.27 231.05 520.00 520.00 200.00 77.00 0.00 0 0 0 0 0 0 0 0 1548.05 2098719.17 4723316.00 0.00 4723316.00 0.00 0.00 1816660.00 0.00 699414.10 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 14061425.27 #REF! 0
32 10.15 Providing and fixing pressed steel door frame confirming IS code 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-Charge. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
33 10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 1618.00 each 165.40 267617.20 174.00 460.00 460.00 460.00 64.00 0.00 0 0 0 0 0 0 0 0 1618.00 28779.60 76084.00 0.00 76084.00 0.00 0.00 76084.00 0.00 10585.60 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 267617.20 #REF! 0
34 10.36 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.). 4876.84 kg. 546.80 2666658.25 1857.26 1857.26 1162.32 0 4876.84 0.00 1015551.64 0.00 1015551.64 0.00 0.00 635554.98 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 2666658.25 #REF! 0
35 10.32 Steel work welded in built up section/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
36 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
37 10.33 Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying a priming coat of approved steel primer 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
38 10.29 Providing and fixing bright finished brass peg stays 300 mm long of minimum weight 330 gms.to side hung steel windows with necessary welding and machine screws etc. complete. 177.00 each 182.70 32337.90 0.00 0.00 177.00 0.00 0 0 0 0 0 0 0 0 177.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 32337.90 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 32337.90 #REF! 0
39 10.3 Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer. 19.78 sqm 6303.40 124681.25 3.78 8.00 8.00 0.00 0.00 0 0 0 0 0 0 0 0 19.78 23826.85 50427.20 0.00 50427.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 124681.25 #REF! 0
40 10.13 Extra for providing and fixing steel beading of approved shape and section with screws instead of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
41 21.1 Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868, (Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,. Aluminium snap beading tor glazing / paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.) 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
42 21.1.2 For shutters of doors, windows & ventilators including providng and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separtately.) 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
43 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
21.3.2 With float glass panes of 5.50 mm thickness, With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm) 3.78 Sqm 1115.10 4215.08 3.78 0.00 0.00 0.00 0 0 0 0 0 0 0 0 3.78 4215.08 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 4215.08 #REF! 0
44 21.4 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matching to the existing floor finishing and cover plate with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
45 21.16 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc. complete as per direction of Engineer in-charge 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
46 21.13 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 1.00 each 365.20 365.20 1.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 1.00 365.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 365.20 #REF! 0
47 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. 9540.89 sqm 283.30 2702933.85 1734.81 2054.77 2054.77 82.683 1940.59 274.00 0.00 439.356 268 0 0 0 187 5.6 4.5 30.000 0 0 465 9540.89 491470.96 582116.25 0.00 582116.25 0.00 23424.09 549767.83 0.00 77624.20 0.00 124469.55 75839 0 0 0 0 53102 1586 1275 8499.000 0 0 131644 2702933.85 #REF! 0
48 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi : 1 coarse sand) / 1:4 (1 cemnt : 4 coarse sand) 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
49 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 816.34 Sqm 1334.90 1089733.07 56.34 380.00 380.00 0.00 0.00 0 0 0 0 0 0 0 0 816.34 75209.07 507262.00 0.00 507262.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 1089733.07 #REF! 0
50 11.37 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete 1452.54 Sqm 686.80 997603.67 137.03 555.00 555.00 205.51 0.00 0.00 0 0 0 0 0 0 0 0 1452.54 94108.77 381174.00 0.00 381174.00 0.00 0.00 141146.90 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 997603.67 #REF! 0
51 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Motar 1:3 (1cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 5221.43 sqm 795.00 4151032.88 565.42 2100.00 2100.00 295.00 161.00 0.00 0 0 0 0 0 0 0 0 5221.43 449512.88 1669500.00 0.00 1669500.00 0.00 0.00 234525.00 0.00 127995.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 4151032.88 #REF! 0
52 11.41 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
53 11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
54 11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of 1:1:1 (1 lime : 1 surkhi : 1 coarse sand) / 1:4 (1 cemnt : 4 coarse sand) 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
55 11.27 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 308.09 Sqm 1334.90 411265.53 164.09 0.00 110.17 33.83 0 308.09 219043.74 0.00 0.00 0.00 0.00 0.00 147064.79 0.00 45157.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 411265.53 #REF! 0
58 8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels: Granite of any colour and shade,Area of slab over 0.50 sqm 169.54 sqm 4401.20 746185.89 50.00 50.00 56.34 13.20 0.00 0 0 0 0 0 0 0 0 169.54 0.00 220060.00 0.00 220060.00 0.00 0.00 247970.05 0.00 58095.84 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 746185.89 #REF! 0
59 11.38 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such shades except white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete. 20.00 Sqm 862.40 17248.00 0.00 20.00 0.00 0 0 0 0 0 0 0 0 20.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 17248.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 17248.00 #REF! 0
b 13.18 15mm cement plaster 1:3 (1cement : 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall 74.00 sqm 229.30 16968.20 0.00 0.00 0.00 0.00 0 0 0 0 0 0 74.000 0 0 74.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 16968.200 0 0 0 16968.20 #REF! 0
63 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 50036.45 sqm 105.40 5273842.08 6885.30 15195.00 15195.00 10976.46 1784.69 0.00 0 0 0 0 0 0 0 0 50036.45 725710.62 1601553.00 0.00 1601553.00 0.00 0.00 1156919.13 0.00 188106.33 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 5273842.08 #REF! 0
64 13.77 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
a 13.81.1 With ready mixed pink or grey primer of approved brand and manufacture on woodwork (hard and soft wood) Paintingwithreadymixedpaintofapprovedbrandandmanufacture in all shades to give an even shade 3193.60 sqm 39.70 126786.00 524.62 1071.41 1071.41 368.16 158.00 0.00 0 0 0 0 0 0 0 0 3193.60 20827.35 42534.96 0.00 42534.96 0.00 0.00 14616.12 0.00 6272.60 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 126786.00 #REF! 0
b 13.81.3 With ready mixed red oxide zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works, Paintingwithreadymixedpaintofapprovedbrandandmanufacture in all shades to give an even shade 1818.33 sqm 34.60 62914.05 0.00 614.05 614.05 338.23 252.00 0.00 0 0 0 0 0 0 0 0 1818.33 0.00 21246.13 0.00 21246.13 0.00 0.00 11702.59 0.00 8719.20 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 62914.05 #REF! 0
66 13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shed. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
67 13.116 Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge. 5236.64 Metre 47.10 246645.90 488.10 1309.04 1309.04 841.46 1289.00 0.00 0 0 0 0 0 0 0 0 5236.64 22989.51 61655.78 0.00 61655.78 0.00 0.00 39632.93 0.00 60711.90 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 246645.90 #REF! 0
71 13.77A Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
72 22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed protions of W.C. kitchen and the like consisting of : 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
iv) IVth course of 400 micron thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm 2318.10 Sqm 480.60 1114078.86 127.10 850.00 850.00 252.00 43.00 0.00 0 0 0 0 0 0 196.000 0 0 2318.10 61084.26 408510.00 0.00 408510.00 0.00 0.00 121111.20 0.00 20665.80 0.00 0.00 0 0 0 0 0 0 0 0 94197.600 0 0 0 1114078.86 #REF! 0
73 22.8 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations : 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
74 2.28+ 11.72 + 4.1.6 + 13.11.4 + Derive Providing plinth protection 750 mm wide consisting of 12 mm thick cement plaster 1;6 with neat cement punning over 75 mm thick P.C.C. (1:3 :6) over brick flat soling over 75 mm thick local sand filling all complete 483.03 Sqm 744.40 359563.81 122.03 123.00 123.00 79.00 36.00 0.00 0 0 0 0 0 0 0 0 483.03 90835.41 91561.20 0.00 91561.20 0.00 0.00 58807.60 0.00 26798.40 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 359563.81 #REF! 0
75 2.37 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) : 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
76 2.37.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand ) to match the existing floor. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
77 5.27 Providing and filling in position bitumen mix filler of Proportion 80 kg of hot bitumen, 1 kg, of cement and 0.25 cubicmetre of coarse sand for expansion joints, 1517.67 100mL_x 1cmWx1cmD 241.07 365864.71 505.89 505.89 505.89 1517.67 0.00 121954.90 0.00 121954.90 0.00 0.00 121954.90 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 365864.71 #REF!
78 5.29 Providing and fixing sheet covering over expansion joints with iron screws as per design to match the colour/shade of wall treatment, 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF!
81 11.76 Derived Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I. 628.49 cum 3466.96 2178932.36 37.49 291.00 291.00 6.00 0.00 0 0 3.00 0 0 0 0 0 628.49 129959.00 1008885.36 0.00 1008885.36 0.00 0.00 0.00 0.00 20801.76 0.00 0.00 0 0 0 0 10401 0 0 0 0.000 0 0 0 2178932.36 #REF! 0
82 12.5 Derived Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I. 47.00 cum 3466.96 162947.12 0.00 47.00 0 47.00 0.00 0.00 0.00 0.00 0.00 0.00 162947.12 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 162947.12 #REF! 0
83 17.1.1 Providing and fixing white vitreous china water closet squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, 10 litre low level PVC flushing cistern (of approved make) with fittings CI/MS brackets, 32 mm diameter flush pipe with fittings and clamps, over flow arrangement with specials and mosquito proof coupling of approved municipal design including painting of fittings and brackets, cutting and making good the walls and floors wherever required. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
84 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
85 17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
86 17.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
87 17.28 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
88 17.31 Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers comelete. 183.00 each 1068.50 195535.50 27.00 52.00 0.00 52.00 44 0.00 8.00 0 0 0 0 0 0 0 0 183.00 28849.50 0.00 55562.00 0.00 55562.00 0.00 0.00 47014.00 0.00 8548.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 195535.50 #REF! 0
90.1 17.70.1 Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 183.00 each 325.10 59493.30 27.00 52.00 0.00 52.00 44 0.00 8.00 0 0 0 0 0 0 0 0 183.00 8777.70 0.00 16905.20 0.00 16905.20 0.00 0.00 14304.40 0.00 2600.80 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 59493.30 #REF! 0
91 17.70.2 Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms. 69.00 each 325.10 22431.90 25.00 22.00 0.00 22.00 0.00 0.00 0 0 0 0 0 0 0 0 69.00 8127.50 0.00 7152.20 0.00 7152.20 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 22431.90 #REF! 0
92 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 108.00 each 146.30 15800.40 4.00 52.00 0.00 52.00 0.00 0.00 0 0 0 0 0 0 0 0 108.00 585.20 0.00 7607.60 0.00 7607.60 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 15800.40 #REF! 0
93 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 104.00 each 204.70 21288.80 4.00 50.00 0.00 50.00 0.00 0.00 0 0 0 0 0 0 0 0 104.00 818.80 0.00 10235.00 0.00 10235.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 21288.80 #REF! 0
94 17.80 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 69.00 each 6534.20 450859.80 25.00 44.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 69.00 163355.00 0.00 287504.80 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 450859.80 #REF! 0
95 8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
98 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
99 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
100 17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. 24.00 Each 299.40 7185.60 2.00 0.00 22 0.00 0.00 0 0 0 0 0 0 0 0 24.00 598.80 0.00 0.00 0.00 0.00 0.00 0.00 6586.80 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 7185.60 #REF! 0
101 18.48 PVC water tank Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 90000.00 per L 9.70 873000.00 10000.00 30000.00 0.00 30000.00 10000.00 0.00 10000.00 0 0 0 0 0 0 0 0 90000.00 97000.00 0.00 291000.00 0.00 291000.00 0.00 0.00 97000.00 0.00 97000.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 873000.00 #REF! 0
104 17.37 Providing and fixing M.S. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) including cost of cutting holes and making good the walls etc. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
105 17.38 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
107 17.43 Providing and fixing single equal plain junction of required degree with acesses door, insersion rubber washer 3mm thick, bolts and nuts complete. 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
110 17.49 Providing and fixing double equal plain inverted branch of required degree. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
112 17.58 Providing lead caulked joints to sand cast iron / centrifugallly cast (spun) iron pipes and fittings of diametre: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
113 17.59 Providing and fixing M.S stays and clamps for sand cast iron/centrifugally cast (spun) iron pipes of diametre. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
114 17.60 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
115 17.65 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
117 12.78 Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
118 12.79 Providing & fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
119 12.8 Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
120 12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete. 81.00 Each 189.40 15341.40 10.00 32.00 0.00 32.00 5.00 0.00 2.00 0 0 0 0 0 0 0 0 81.00 1894.00 0.00 6060.80 0.00 6060.80 0.00 0.00 947.00 0.00 378.80 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 15341.40 #REF! 0
121 18.4 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
122 18.4 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
123 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
124 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
125 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
126 11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
127 15 Providing, installation, testing and commissioning of stainless steel Y strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
128 N.S Providing and fixing brass Single acting air valve PN 1.6 of approved quality with bolts, nuts, rubber insertion, tail pieces, tapers etc. if required as complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
129 N.S Providing and fixing motorised butterfly valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc., complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
130 17.7 Providing and fixing wash basin with C.I. / M.S. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
131 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
132 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
133 18.22 Providing and fixing N.P./C.P. brass/ P.V.C. porcelain shower rose of 15 mm inlet etc. all complete as per specification and direction of Engineer-in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
134 17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
136 18.17 Providing & fixing gun metal gate valve with C.I. wheel of approved quality, (screwed end) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
137 4.1 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
138 2.8.1 Earth work in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.. All Kinds of soil 1034.43 Cum 360.70 373119.07 0.00 0.00 158.030375 0.00 0.00 839.9950915 34.13 0 0 0 0 0 0 0 0 2 1034.43 0.00 0.00 0.00 0.00 0.00 57001.56 0.00 0.00 0.00 0.00 302986.23 0 12309 0 0 0 0 0 0 0.000 0 0 822 373119.07 #REF! 0
139 4.1.3 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4(1 Cement: 2coarse sand:4 graded stone aggregate 20 mm nominal size) 467.97 Cum 3998.10 1870986.86 0.00 0.00 4.836 0.00 0.00 25.729 357 0 0 0 18.74 0.56 0.45 0 0 61 467.97 0.00 0.00 0.00 0.00 0.00 19334.81 0.00 0.00 0.00 0.00 102867.11 1427042 0 0 0 0 74940 2239 1799 0.000 0 0 242765 1870986.86 #REF! 0
141 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
142 13.82.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: new steel surface 580.36 Sqm 83.50 48459.98 0.00 0.00 102.744 0.00 0.00 477.615 0 0 0 0 0 0 0 0 580.36 0.00 0.00 0.00 0.00 0.00 8579.12 0.00 0.00 0.00 0.00 39880.85 0 0 0 0 0 0 0 0 0.000 0 0 0 48459.98 #REF! 0
143 11.73 Providing designation 100 A one brick on edge soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, 1784.65 Sqm 444.80 793813.21 0.00 0.00 0.00 0.00 1785 0 0 0 0 0 0 0 0 1784.65 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 793813 0 0 0 0 0 0 0 0.000 0 0 0 793813.21 #REF! 0
144 2.32 Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 5967.99 100 sqm 697.40 41620.75 0.00 0.00 0.00 0.00 5967.99 0 0 0 0 0 0 0 0 5967.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 41621 0 0 0 0 0 0 0.000 0 0 0 41620.75 #REF! 0
145 23.1 Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure) 895.20 sqm 44.70 40015.36 0.00 0.00 0.00 0.00 895.20 0 0 0 0 0 0 0 0 895.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 40015 0 0 0 0 0 0 0.000 0 0 0 40015.36 #REF! 0
146 23.2 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment) 4910.58 cum 143.50 704668.79 0.00 0.00 0.00 0.00 4652 259.00 0 0 0 0 0 0 0 0 4910.58 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 667502 37167 0 0 0 0 0 0 0.000 0 0 0 704668.79 #REF! 0
147 23.4 Supplying and stacking at site dump manure from approved source, excluding carriage (manure measured in stacks will be reduced by 8% for payment) 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
c 23.8 Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately) 315.00 cum 30.10 9481.50 0.00 0.00 0.00 0.00 315.00 0 0 0 0 0 0 0 0 315.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 9482 0 0 0 0 0 0 0.000 0 0 0 9481.50 #REF! 0
148 23.12 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. 5967.99 100 sqm 3418.20 203997.76 0.00 0.00 0.00 0.00 5967.99 0 0 0 0 0 0 0 0 5967.99 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 203998 0 0 0 0 0 0 0.000 0 0 0 203997.76 #REF! 0
149 23.10 Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free form weeds and fit for moving including supplying good earth if needed. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
150 23.14 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately) 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
151 23.13 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 67.50 cum 126.90 8565.75 0.00 0.00 0.00 0.00 67.50 0 0 0 0 0 0 0 0 67.50 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 8566 0 0 0 0 0 0 0.000 0 0 0 8565.75 #REF! 0
154 13.78 Applying one coat of cement primer of approved brand and manufacture on wall surface : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
155 13.79 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
156 2.10 Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
157 2.11 Extra for Excavating trenches for Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 381.54 Metre 126.20 48150.35 0.00 382 381.54 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 48150 0 0 0 0 0 0.000 0 0 0 48150.35 #REF! 141.00 240.54 382
158 2.12 Extra for excavating trenches for pipes, cables, etc.in ordinary/hard rock exceeding 3.0 m in depth but not exceeding 4.5 m.(Rate is over corresponding basic item for depth upto 1.5 Metre.)Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 30.00 Metre 316.60 9498.00 0.00 30 30.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 9498 0 0 0 0 0 0.000 0 0 0 9498.00 #REF! 15.00 15 30
159 18.27 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
160 18.3 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
161 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
162 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) all-round S.W. pipes including bed concrete as per standard design. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
163 4.1 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 20 mm nominal size) alround stoneware/RCC pipes including in bed for pipes to be laid in trenches as per standard details. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
164 19.4 Providing and fixing square mouth S.W. gully trap grade 'A' complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water tight C.I. Cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as/standard design. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
165 19.7 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement: 4 coarse sand) R.C.C. top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand: 8 graded stone aggregate 20 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
167 19.9 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 6.00 0.00 0.00 0.00 0.00 0.00 6 0 0 0 0 0 0 0 6.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 6 6
170 19.11 Constructing brick masonry circular type manhole 1.2 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
172 19.13 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.13.1 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
174 19.16 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on12mm dia steel bar conforming to IS :1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protrude legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 270.00 Each 310.90 83943.00 0.00 0.00 0.00 0.00 270 0 0 0 0 0 0 0 270.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 83943 0 0 0 0 0 0.000 0 0 0 83943.00 #REF! 101 94 75 270
175 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
176 2.10 Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
177 19.6 Providing, laying Non pressure NP2 class (light duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing and jointing etc complete. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
178 19.3 Providing and laying cement concrete 1:5:10 (1 cement:5 coarse sand:10 graded stone aggregate 20mm nominal size) up to haunches of SW/RCC Pipes including bed concrete as/standard design: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
179 19.7 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement: 4 coarse sand) R.C.C. top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand: 8 graded stone aggregate 20 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.7.1 Inside size 90x80 cm and 60 cm deep including CI Cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg) 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
180 19.9 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.9.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
182 19.11 Constructing brick masonry circular type manhole 1.2 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.11.1 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
184 19.13 Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
19.13.1 2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
186 19.27 Constructing brick masonary road gully chamber 50x45x60cm with bricks of class designation 75 in cement morter 1:4 (1 cement : 4 coarse sand) including 500 x 450mm precast RCC horizontal grating complete as per standard design 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
187 18.41 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
188 14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
189 18.59 Providing & fixing C.I. double acting air valve of approved quality with bolt, nuts, rubber insertions etc. complete. (The tail piece if required will be paid separately) 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
190 18.33 Constructing masonry chamber 60x60x75 cms inside, in brick work in cement mortar, 1 : 4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter ,160 mm bottom diameter and 180 mm deep (inside) with chained lid and rcc top slab 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
191 18.34 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
192 AR Providing, fixing, testing & commissioning of vertical multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS304 impellers with stainless steel SS304 shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900 RPM, suitable for 400/440 volts, 3 phase, 50 Hz AC supply with pressure gauge and with gunmetal isolation cocks, vibration elimination pads etc. complete with base and frame, nuts and bolts and necessary RCC foundations as per requirement as per instructions and pump shall have following duty. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Providing,fixing, Testing & Commissioning of package type skid mounted hydropneumatic system comprising of: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Vertical, inline multistage centrifugal pumping set with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 volts, 3 phase, 50 Hz AC supply. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane. Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Pump mounted or panel mounted microprocessor PID controller and variable frequency drive (VFD) integrated in a single body or as separate components with pressure sensor transmitter (one dedicated to each pump) minimum two lined LCD display, diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. System should be capable to compensate for frictional losses at lower flows. All alarms should be displayed in the controller. System should be equipped with dry running protection. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Pressure switches sensor type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Ball valves to be used should be Hot Pressed brass OT-58 with stainless steel ball and PTFE seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Complete set including all necessary suction and delivery valves and accessories, with the system to be skid-mounted on a common base frame and the following shall be the working duty. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
194 AR Providing,fixing, testing & Commissioning of Sump Pumps for lifting water from drainage sumps in plant room 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Providing, fixing, testing & Commissioning of compact mono block dry motor submersible pumps for suitable rating, with non-clog free flow open impeller, minimum solid handling capacity of 14 mm suitable for operation on 415 volts + 5% -15%, 50 C/s A.C single phase supply, speed 960/1440R&M including oil chamber, guide wire for lifting & lowering of pump, M.S. galvanized lifting chain, duck foot bend with following specifications: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
The above pump sets must be supplied complete with following accessories. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
a) Complete piping 100mm dia common delivery upto 5m as per enclosed tentative layout. (The pipe should be preferably CI LA/heavy duty G.I) -- 1 Set 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
d) Necessary cables from pump set to control panel (position of panel marked in enclosed layout in plant room).-- 1 Set 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
e) Electrical switch panel having all necessary accessories & safety devices of standard specifications. (Panels with sump pumps near each sump as per site conditions). - 1 No. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
f) Automatic built-up water level controller with necessary length of cable upto control panel. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
195 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 Metre depth below ground level. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
196 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 460.00 Cum 1343.20 617872.00 0.00 0.00 0.00 0.00 460 0 0 0 0 0 0 0 460.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 617872 0 0 0 0 0 0.000 0 0 0 617872.00 #REF! 440 20 460
197 24.10 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia,conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
198 24.11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed /plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
199 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 264.00 Hour 916.80 242035.20 0.00 0.00 0.00 0.00 264 0 0 0 0 0 0 0 264.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 242035 0 0 0 0 0 0.000 0 0 0 242035.20 #REF! 264 264
200 A.R Supply, installation, testing and commissioning of suitable capacity and typ of Submerssible pump set capable to discharge 20000lits. Of clean filtetred water from a 250mm 150mm deep tube well at a total head of 30m complete with control panel, 24m of suitable size G.I. Column pipe, bend, gate valve, nipple supporting,clamp,30m of neoprene cable etc copmplete as required. 1.00 Set 80000.00 80000.00 0.00 0.00 0.00 0.00 1 0 0 0 0 0 0 0 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 80000 0 0 0 0 0 0.000 0 0 0 80000.00 #REF! 1 1
201 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 Metre depth below ground level. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
202 24.10 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia,conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
203 24.11 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed /plain bevel ended pipe (type A) of required dia, conforming to IS:8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
205 24.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
206 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
207 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 105.00 Cum 1188.90 124834.50 0.00 0.00 0.00 0.00 105 0 0 0 0 0 0 0 105.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 124835 0 0 0 0 0 0.000 0 0 0 124834.50 #REF! 105 105
208 24.6 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 105.00 Cum 1195.60 125538.00 0.00 0.00 0.00 0.00 105 0 0 0 0 0 0 0 105.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 125538 0 0 0 0 0 0.000 0 0 0 125538.00 #REF! 105 105
209 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 105.00 Cum 1195.60 125538.00 0.00 0.00 0.00 0.00 105 0 0 0 0 0 0 0 105.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 125538 0 0 0 0 0 0.000 0 0 0 125538.00 #REF! 105 105
210 24.13 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
211 24.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
212 19.19 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
214 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
216 5.9 Centring and shuttering including strutting, propping etc. and removal of form for 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
5.9.20 Suspended floors, roofs, landings, balconies and access platform with water proofply 12 mm thick 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
219 18.12.8 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
221 17.30 Providing and fixing in position 25mm diameter mosquito proof coupling of approved municipal design 2.00 Each 45.30 90.60 0.00 0.00 0.00 0.00 0 0 0 0 0 0 2.000 0 0 2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 90.600 0 0 0 90.60 #REF! 0
222 18.31 Providing and fixing C.I. sluice valves (with cap) complete with bolts,nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
223 AR Size: Executive Desk Size - 1800mm (W) x 900mm (D) x 750mm (H) Side Unit - 800mm (W) x 600mm (D) x 675mm (H) Combination of metal and wood reflects dynamism. Sleek floating top gives aesthetic and trendy look. Open rectanglular section legs with small modesty gives the table trendy, airy open look. 3.00 Each 30975.00 92925.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 3 0 3.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 92925 0 0 92925.00 #REF! 0
224 AR Size : 2.40 m x 1.05m x 750mm Providing & making meeting table of given size made of 35mm thick block board with 1.0mm thick laminate at top and 1-1/2" TW beading on all the sides with proper niche in between beading and laminate edge 25mm thick round laminated pedestal and wooden frame work 75 x 62mm T.W bracket as top support including polishing of wooden frame work and melamine finish all complete as per drawings. 1.00 Each 34000.00 34000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 1 0 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 34000 0 0 34000.00 #REF! 0
225 AR Class room desk - 2 seater with pedestal storage unit (for Class room) & sitting Desk (size : 1050 x 450 x750 (H) Supply,Fabrication & Installation of class room table top 19 mm thick prelimanated board with 2mm PVC edge banding , supported on MS square Hollow section (size : 40 mm x 40 mm) frame complete with wire manager at table top all fitting & assecories as per drawing & direction of E/I. 360.00 Each 9000.00 3240000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 360 0 360.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 3240000 0 0 3240000.00 #REF! 0
226 AR Seat/Back Assembly: The seat is made up of 1.2 ±0.1cm thick hot pressed plywood measured as per QA method described in OCP-QLTA- P14-18 and upholstered with fabric moulded Polyurethane Foam. The back is made up of 1.2 ±0.1cm hot pressed plywood upholstered with fabric moulded polyurethane foam. The back ply and foam is designed with contoured lumber support for comfortable seating posture. Mid Back Size - 48cm (W) x 64.5cm (H). Seat Size - 51cm (W) x 48cm (D) Armrest (Adjustable): The armrest top is made up of moulded polyurethane (P.U) and mounted on to a drop lift height adjustable type M.S. tubular armrest support chrome plated. The armrest height is adjustable up to 6.5±0.5cm in 5 steps & also has swivel adjustment of 22° ± 2° on both sides. Knee Tilt Synchro Mechanism with Seat Deapth Adjustment Mechanism: The mechanism is designed with the following features - 360° revolving type, Single point control, Front pivot for tilt with feet resting on ground ensuring more comfort, Tilt tension adjustment, 4-position locking with anti-shock feature, Seat back tilting ratio of 1:2 & Seat depth adjustment of 6.0 ± 0.5cm can be locked in 6 positions. Adjustable Backrest: The backrest consists of a sliding up down mechanism, which can be adjusted in the range of 7.5 ± 0.5cm and can be locked in 4 positions for correct position of lumber support. Pneumatic Height Adjustment: The pneumatic height adjustment has an adjustment of 9.0 ± 0.3cm. Pedestal Assembly: The pedestal is fabricated from 0.2 ± 0.2cm thick HR sheet (IS : DD 1079 / HR skin pass), chrome plated and assembled with injection moulded black polypropylene hub cap and 5 nos. twin wheel castors. The pedestal is 66.0±0.5cm Pitch-center dia. (76.0 ± 1.0cm with castors). Twin Wheel Castors: The twin wheel castors are injection moulded in black Nylon. 3.00 Each 6608.00 19824.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 3 0 3.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 19824 0 0 19824.00 #REF! 0
227 AR S/F ct site Godrej steel Multifux system of size 7' x 36 " x 18" with 7 nos. shalves of galvanised steel sheet with M.S steel angle frame of size 40x40x8 mm. Complete with supplying and fixing at site with including painting etc. as per direction of E/I 24.00 Each 9200.00 220800.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 24 0 24.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 220800 0 0 220800.00 #REF! 0
228 AR Table for class room/office (size : 1200 x 900 x 750) Supply, Fabrication & Installation of table made of Powder coated MS frame with 18mm thick prelaminated board top complete in all respect with wire manager lockable drawers etc. all complete as per drawing and direction of E/I 43.00 Each 8800.00 378400.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 43 0 43.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 378400 0 0 378400.00 #REF! 0
229 AR Providing and fixing in position magnatic white board on walls including teak wood edge moulding. Complete with all necessery hardware, polish etc as per direction of E/I Size : 8' x 4' 19.00 Each 14500.00 275500.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 19 0 19.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 275500 0 0 275500.00 #REF! 0
230 AR 3 sector chair (Chrome) Made of Cushion with high density cold cured self -skinned pre -molded foam of 50-60 density the shape of plywood. Upholstery is done by using high-pressure pneumatic spray glue and pneumatic press over crome base & legs etc. all complete as per direction of E/I 5.00 Each 10620.00 53100.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 5 0 5.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 53100 0 0 53100.00 #REF! 0
231 AR Computer Table - (size : 900 x 600 x 905 mm) computer Lab Supply and installation of Prelaminated particle board of wood finish on both side and top on hard wood frame with drawer, Cabinet and wire manager complete with all necessary hardware and as per drawing design and direction of E/I. 20.00 Each 10500.00 210000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 20 20.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 210000 0 0 210000.00 #REF! 0
232 AR Computer Chair : Supply and installation of Telemate medium back chair with single point lock tilting mechanism castor and latherlite sheet over PU foam sheet complete on crome base 55.00 Each 2921.00 160655.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 55 0 55.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 160655 0 0 160655.00 #REF! 0
233 AR Structure is made up of 40 mm dia CRC tube with thickness 18 gauge. Horizontal base is made from steel sheet the thickness 14 gauge. Horizontal base will be stiffened with appropriate longitudinal 3 v shape sheet and lateral stiffeners 2 steel pipes with powder coating. Manufactured out of ISO 9001, ISO14001 and OSHSAS 18001 certified Plant and product certified for BIFMA performance test (Size : 2000 x 900 x 650 mm (H) 720.00 Each 11000.00 7920000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 720 0 720.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 7920000 0 0 7920000.00 #REF! 0
234 AR Supplying and fixing of Mattress (size : 75"x36" x 2" thick) at site, with complete in all respect or as per direction of E/I 720.00 Each 4400.00 3168000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 720 0 720.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 3168000 0 0 3168000.00 #REF! 0
235 AR Dimension : DESK - 600 W x 480 D x 750 H SEAT - 868 H x 500 W x S 450 Finish/Coating : Powder Coating Material : MILD STEEL TUBULAR SECTION OVAL Tube 35 x 15 SQ. Tube 5x25 and PLB & Moulded wood Total Weight : 23Kg Available Base Frame : Knock down Features : >SEMI KNOCKDOWN > 11 TANK HOT ZINC PHOSPHATING PRE TREATMET PROCESS > Powder Coated 720.00 Each 6800.00 4896000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 720 0 720.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 4896000 0 0 4896000.00 #REF! 0
236 AR Work Surface: 25mm Thick (±1mm) Base Material - 25mm MDF Board on top PU painting of Minium 2H hardness with 75% glass as per color chart, combination color graphics on the centre. Color as per color chart. Brown laminate on bottom. Specially profiled edge for comfort. Understructure: Bend pipe understructure of MS. Powder Coated. Pipe dia. 38mm, 2mm thk. Understructure fitted with top by SS machine screws. Legs: MS Powder coated legs for PU top & SS legs for membrane top. 38mm dia pipe legs are fixed with understurcture and table top. Glide: Plastic Glide fixed at the understructure to prevent the damage of table top druing stacking. Size: Ground Base - 2450mm (L) x 1175mm (W). Surface Top - 2400.8mm (L) x 050.4mm (W) & Height - 750mm (H) 38.00 Each 25429.00 966302.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 38 0 38.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 966302 0 0 966302.00 #REF! 0
237 AR Seat/Back: Seat & Back are injection moulded in PP. They are snap fitted on the understructure assembly and fixed with self-taping screws Approx. Back Size : 37.0cm (W) x 25.5cm (H) Approx. Seat Size : 40.5cm (W) x 40.5cm (D) Understructure Assembly: The understructure assembly is a welded frame assy. with the upper frame made of dia. Ø 1.9±0.02cm x 0.2±0.016 thk. and legs made of Ø 1.9±0.02cm x 0.16±0.0128cm thk. M.S. E.R.W tubes and black powder coated (DFT 40-60 microns) 304.00 Each 1800.00 547200.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 304 0 304.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 547200 0 0 547200.00 #REF! 0
238 AR Size : Depth (D) - 57.0 cm, Width (W) - 58.0 cm, Height (H) - 88.0 cm, Seat Height (SH) - 47.5 cm The seat & Back are made up of Cushion covered with rexine. Behind all this is a robust tubular framework that makes the chairs durable. 120.00 Each 1800.00 216000.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 120 0 120.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 216000 0 0 216000.00 #REF! 0
239 (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical conforming to IS:1520 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(b) Suitable HP squirell cage induction motor TEFC, synchronous speed 1500RPM,suitable for operation on 415 volts, 3-Phase, 50Hz, Ac supply with IP55 class of protection for enclosure, horizontal foot mounted type with class F insulation, conforming to IS-325. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(c) M.S fabricated common base plate, coupling , coupling guard, foundation bolts etc. as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(d) Suitable cement concrete foundation duly plastered and with anti vibration pad. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
240 Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
a) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechnism, 12/24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10m outside pump house duly insulated with 50mm thick glass wool with 1.0mm thick aluminium sheet cladding residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(c) M.S fabricated common base plate, coupling , coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with antivibration pad. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
241 a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump) 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS:1520. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase. 50Hz AC supply with IP55 class of protection for enclousure, horizontal foot mounted type with Class-"F" insulation, conforming to IS:325. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(d) M.S fabricated common base plate, coupling , coupling guard, foundation bolts etc. as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
242 5.6 Fabricating, Supplying, Erection, Testing and commissioning of Electrical control panel cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet,compartmentalised with hinged lockable doors, dust and vermin proof, coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V, 3 Phase, 50Hz Ac supply with enclosure protection class IP42 as required: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamp set of copper Bus Bar 500A. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps). 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
250A, 50KA TPN MCCB, Ics=100% Icu, with fully automatic star/delta starter suitable for 100HP pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation- 2sets 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
125A, 50KA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation-2 sets 1.00 Set 581468.00 581468.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 1 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 581468 0 581468.00 #REF! 0
243 7 Providing, laying , testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gasket etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
244 9 Supply and fixing single headed external yard hydrant valve with instanteneous Gunmetal/Stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless steel cap and chain as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
245 Supply,fixing,testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS:13095 of following size as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
246 14 Providing, installation, testing and commissioning of non-return valve of following sizes conforming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
247 15 Providing , installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6mm thick stainless steel, Grade 304, sheet with 3mm dia holes with stainless steel flange. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
248 Supplying and fixing 63mm dia, 15m long RRL hose pipe with 63mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 ( Type-A) as required: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
249 Supplying and fixing 63mm dia gun metal short branch pipe with 20mm nominal diameter size nozzle confirming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
250 Supplying and fixing for Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as required for suitable dia MS pipe connection conforming to IS 904 as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
251 20 Supplying and fixing air vessel made of 250mm dia. 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 7.00 Set 17707.00 123949.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 7 7.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 123949 0 123949.00 #REF! 0
252 22 Providing and fixing of Pressure switch in M.S pipe line including connection etc. as required. 3.00 Each 1442.00 4326.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 3 3.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 4326 0 4326.00 #REF! 0
253 4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads 0.00 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
255 Supply and fixing single headed internal yard hydrant valve with instanteneous Gunmetal/Stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless steel cap and chain as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20mm nominal dia water hose thermoplastic ( Textile reinforced) type-2 as per IS:12585 20mm nomonal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. " Connections from riser with 25mm dia stop gunmetal valve & M.S Pipe and socket. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
256 ISI marked (IS:2878) Portable fire Extinguisher, Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1m long & complete in all respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
257 'ABC' stored pressure type Dry Chemical Powder (Mono-Ammonium Phosphate ) 6 kg fire extinguisher with fixing hangers, hose, brackets, screws to required size etc., complete as per IS:14609. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
258 NS Providing and fixing 25 mm dia gun metal single acting air release valve with screwed inlet tested for 20 kg. / cm². 3.00 Each 1722.00 5166.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 3 3.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 5166 0 5166.00 #REF! 0
259 NS Providing and fixing 25 mm dia brass ball valve full bore type with lever and screwed female ends. ( 20 kg./sq. cm.) 26.00 Each 1722.00 44772.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 26 26.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 44772 0 44772.00 #REF! 0
260 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required (Terrace Pump) 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron & bronze impeller with stainless steel shaft, mechanical conforming to IS:1520 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(b) Suitable HP squirell cage induction motor TEFC, synchronous speed 1500RPM,suitable for operation on 415 volts, 3-Phase, 50Hz, Ac supply with IP55 class of protection for enclosure, horizontal foot mounted type with class F insulation, conforming to IS-325. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(c) M.S fabricated common base plate, coupling , coupling guard, foundation bolts etc. as required. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(d) Suitable cement concrete foundation duly plastered and with anti vibration pad. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
Fabricating, Supplying, Erection, Testing and commissioning of Electrical control panel cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet,compartmentalised with hinged lockable doors, dust and vermin proof, coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V, 3 Phase, 50Hz Ac supply with enclosure protection class IP42 as required: 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
250A, 50KA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250A) with selector switch & CTs etc. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0 f
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamp set of copper Bus Bar 300A. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
(Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps). 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
125A, 50KA TPN MCCB, Ics=100% Icu, with fully automatic star/delta starter suitable for 60HP pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
261 5.1 63A, 50KA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 3.00 Set 248187.00 744561.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 3 3.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 744561 0 744561.00 #REF! 0
262 17.2.1 DSR 2022 (E & m) Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 0 0.00 #REF! 0
263 17.2.3 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2.00 Each 108688.00 217376.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 2 2.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 217376 0 217376.00 #REF! 0
264 17.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 175.00 Each 2858.00 500150.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 175 175.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 500150 0 500150.00 #REF! 0
265 17.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 20.00 Each 276.00 5520.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 20 20.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 5520 0 5520.00 #REF! 0
266 17.2.6 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 9.00 Each 2651.00 23859.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 9 9.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 23859 0 23859.00 #REF! 0
267 17.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 9.00 Each 3871.00 34839.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 9 9.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 34839 0 34839.00 #REF! 0
268 17.5.1 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 1900.00 Mtr. 359.00 682100.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 1900 1900.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 682100 0 682100.00 #REF! 0
270 11.77 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern 731.71 SQM 721.10 527634.15 0.00 732 0 731.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 527634 0 0 0 0 0 0 0 0.000 0 0 0 527634.15 #REF! 0
271 16.1 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 731.71 SQM 90.70 66365.85 0.00 732 0 731.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 66366 0 0 0 0 0 0 0 0.000 0 0 0 66365.85 #REF! 0
272 11.30.2 40 mm thick fine dressed stone flooring over 20 mm (average) thick base with joint finished fiush:base 1:5 (1 cement: 5 coarse sand )with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.White sand stone 464.68 SQM 878.60 408271.38 0.00 0 465 464.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0.000 0 0 408271 408271.38 #REF! 0
273 4.3.1 Centring and shuttering including strutting,propping etc. and removal or form work forFoundations,footings, bases Columns 66.53 211.10 14043.43 66.525 66.53 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 14043.43 0 0 0 0 0 0 0 0 0.000 0 0 0 14043.43 #REF!
279 CORRECTION FACTOR @ 0.982 (ON S.NO.277)= ₹ 415,985,364.00
Add for Operation, Maintenance & Repair Cost ₹ 17,490,465.00
TOTAL (CIVIL WORK)= ₹ 480,584,249.00
PART-'A' School Building (G+2)
1 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder point 160
T/L Light Point Double 56
Consta light point 40 watt 190
Ceiling fan point 150
Exhaust fan point 25
Call Bell point 3
2 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 85 Each 414.00 35,190.00
3 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 76 Each 531.00 40,356.00
4 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1140 Meter 309.00 352,260.00
5 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.(use for AC box) 24 Each 683.00 16,392.00
6 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.(use for computer point) 52 Each 1,064.00 55,328.00
7 1.55 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 27 Each 632.00 17,064.00
8 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(for CKT) 1720 Meter 201.00 345,720.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(for Comp +2 nos 5 A) 1185 Meter 246.00 291,510.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(for LED street light) 240 Meter 246.00 59,040.00
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(for AC) 384 Meter 309.00 118,656.00
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire(for LED street ;light DB) 15 Meter 422.00 6,330.00
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire (for light DB) 306 Meter 660.00 201,960.00
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire (for power DB) 170 Meter 925.00 157,250.00
1.7.13 4 X 16 sq. mm + 1 X 6 sq. mm earth wire (for VTPN DB) 120 Meter 1,312.00 157,440.00
9 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door (for street light) 1 Each 2,314.00 2,314.00
10 2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), Double door, horizontal type (Power DB-10, Light DB-18) 28 Each 4,184.00 117,152.00
11 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 346 Each 237.00 82,002.00
12 2.33 Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
2.33.1 4 way, Double door, I/C 160A, MCCB(forPower VTPN) (for Ground +first floor & Second Floor) 3 Each 12,107.00 36,321.00
2.33.2 6 way, Double door, I/C 160A, MCCB (for Ground +first floor & Second Floor) Light VTPN 3 Each 13,710.00 41,130.00
13 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.3 160 A, 36 KA, FPMCCB (for VTPN) 6 Each 13,698.00 82,188.00
14 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
15 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 274 Each 64.00 17,536.00
16 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 160 Each 80.00 12,800.00
17 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.6 15 watt LED lamp 160 Each 250.00 40,000.00
18 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 3 Each 351.00 1,053.00
19 5.3 Supplying and fixing 4'X20 watt LED batten with minimum efficacy 100 lm/w in aluminium housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. (For Non-residential building) 56 Each 762.00 42,672.00
20 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
21 5.6 Supplying and fixing following types aluminium extruded suspended type LED luminaire with minimum efficacy 100 lm/w ensuring uniform and continuous illumination including suspension system complete with electronic driver etc and connection with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
22 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
23 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
24 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required. 50 Each 34.00 1,700.00
25 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 150 Each 358.00 53,700.00
26 DSR 9.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 150 Each 2,695.00 404,250.00
27 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
28 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.2 125 A, 36 KA, FPMCCB (Spare) 1 Each 8,676.00 8,676.00
2.4.3 160 A, 36 KA, FPMCCB (One Spare) 7 Each 13,698.00 95,886.00
29 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (Building Light) 1 Each 1,198.00 1,198.00
30 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.4 40 A to 63 A, four pole (One Spare) Campus Light 2 Each 2,324.00 4,648.00
31 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
32 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 30 Sq.ft. 1,809.00 54,270.00
33 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. (Double Bus Bar) 20 P/Kg 871.00 17,420.00
34 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6,536.00 6,536.00
35 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.11 95 sq. mm, 3.5 core (For Genset) 100 Metre 950.00 95,000.00
7.7.15 240 sq. mm, 3.5 core (Double Run) 220 Metre 2,228.00 490,160.00
36 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 80 Metre 326.00 26,080.00
7.1.4 Above 185 sq. mm and upto 400 sq. mm 140 Metre 368.00 51,520.00
37 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
38 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 Set 6,884.00 13,768.00
39 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 30 Metre 144.00 4,320.00
Lighting Arrester
40 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 12 Each 416.00 4,992.00
41 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 36 Each 81.00 2,916.00
42 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 200 Metre 102.00 20,400.00
43 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 180 Metre 145.00 26,100.00
44 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 24 Each 102.00 2,448.00
45 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 6 Set 6,884.00 41,304.00
46 3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. 80 Metre 53.00 4,240.00
( SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM)
47 DSR 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required 38 KWP 54,280.00 2,062,640.00
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and otheraccessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Meta OxideVaristors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
AUTOMATIC FIRE ALARM & DETECTION SYSTEM
48 DSR 28.2 Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
28.2.1.2 Two Loop Panel. 1 Each 250,420.00 250,420.00
28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2 Each 113,734.00 227,468.00
28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 120 Each 3,004.00 360,480.00
28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 15 Each 306.00 4,590.00
28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. 9 Each 2,787.00 25,083.00
28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required 9 Each 3,434.00 30,906.00
28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required 9 Each 3,156.00 28,404.00
28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 9 Each 4,063.00 36,567.00
SAFETY ACCESSORIES & MISC
49 NS Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969 5 Meter 2,208.00 11,040.00
50 NS Shock treatment chart in English and local language duly framed with glass 2 Nos 696.00 1,392.00
51 NS First aid box complete with all standard first aid materials 2 Nos 602.00 1,204.00
52 NS Rubber gloves 11 KV grade as per IS 4770-68 2 Pairs 401.00 802.00
Computer Networking (LAN)
53 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
54 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell ) 60 Each 234.00 14,040.00
55 39.13 Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) 60 Each 173.00 10,380.00
39.13.2 Copper Patch Cords of length 3m (10ft) 60 Each 405.00 24,300.00
56 DSR 39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
57 DSR 39.23 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
58 DSR 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 3 Each 5,278.00 15,834.00
59 NS Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP) 3 Each 20,758.00 62,274.00
60 NS Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link) 3 Each 19,070.00 57,210.00
61 1.58 Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
1.58.1 1 run of cable 2100 Point 52.00 109,200.00
62 NS Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. ) 60 Each 545.00 32,700.00
Total Rs. 9,506,231.00
PART-'B' Boy's/Girl's HOSTEL Building (G+5)
63 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder point 429
Tube LED light 317
2' X 2' Surface Light 99
Ceiling fan point 354
Exhaust fan point 121
Call Bell point 2
Constra Light 40 Watt 107
64 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 90 Each 414.00 37,260.00
65 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 66 Each 531.00 35,046.00
66 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 990 Meter 309.00 305,910.00
67 2.25 Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. 4 Each 3,008.00 12,032.00
68 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.(use for computer point) 147 Each 1,064.00 156,408.00
69 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 6 Each 683.00 4,098.00
70 1.55 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 150 Each 632.00 94,800.00
71 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(for CKT) 4243 Meter 201.00 852,843.00
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(for 2 Nos 5 A Socket) 1800 Meter 201.00 361,800.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(for Comp) 2205 Meter 246.00 542,430.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(for Street light) 180 Meter 246.00 44,280.00
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire for AC 90 Meter 309.00 27,810.00
1.7.10 4 X 4 sq. mm + 1 X 4 sq. mm earth wire (for industrial Socket) 80 Meter 459.00 36,720.00
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire(for light DB) 918 Meter 660.00 605,880.00
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire(for power DB) 80 Meter 925.00 74,000.00
1.7.13 4 X 16 sq. mm + 1 X 6 sq. mm earth wire(from VTPN to Panel) 264 Meter 1,312.00 346,368.00
72 2.33 Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs)
2.33.1 4 way, Double door, I/C 160A, MCCB(for Ground- One, 1st to 5th each Floor having two VTPN) 6 Each 12,107.00 72,642.00
2.33.2 6 way, Double door, I/C 160A, MCCB(for Ground- One, 1st to 5th each Floor having two VTPN) 6 Each 13,710.00 82,260.00
73 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door 1 Each 2,314.00 2,314.00
74 2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), Double door, horizontal type (Power DB-9, Light DB-51) 55 Each 4,184.00 230,120.00
75 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
76 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 670 Each 237.00 158,790.00
77 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole 1 Each 1,198.00 1,198.00
78 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 547 Each 64.00 35,008.00
79 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 429 Each 80.00 34,320.00
80 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.6 15 watt LED lamp 429 Each 250.00 107,250.00
81 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 2 Each 351.00 702.00
82 5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. 99 Each 2,663.00 263,637.00
83 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
84 5.6 Supplying and fixing following types aluminium extruded suspended type LED luminaire with minimum efficacy 100 lm/w ensuring uniform and continuous illumination including suspension system complete with electronic driver etc and connection with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
85 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
86 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
87 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 354 Each 358.00 126,732.00
88 DSR 9.2 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. Make :- Bajaj/Crompton/Orient/Usha.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 354 Each 2,695.00 954,030.00
89 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
CUBICAL PANEL, CABLE & EARTHING
90 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.1 100 A, 30 KA, FPMCCB (for Lift, One Spare) 2 Each 8,172.00 16,344.00
2.4.3 160 A, 36 KA, FPMCCB Two Spare 14 Each 13,698.00 191,772.00
91 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (One Spare) Building Light 2 Each 1,198.00 2,396.00
2.13.4 40 A to 63 A, four pole (One Spare) Campus Light 2 Each 2,324.00 4,648.00
92 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
93 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) 30 Sq.ft. 1,809.00 54,270.00
94 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. (Two Bus Bar) 20 P/Kg 871.00 17,420.00
95 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6,536.00 6,536.00
96 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.16 300 sq. mm, 3.5 core (Main) Double Run 200 Metre 2,764.00 552,800.00
7.7.11 95 sq. mm, 3.5 core (For Genset) 100 Metre 950.00 95,000.00
97 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.4 Above 185 sq. mm and upto 400 sq. mm 180 Metre 368.00 66,240.00
7.1.2 Above 35 sq. mm and upto 95 sq. mm 80 Metre 326.00 26,080.00
98 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
99 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 2 Set 16,675.00 33,350.00
100 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 40 Metre 144.00 5,760.00
Lighting Arrester
101 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 16 Each 416.00 6,656.00
102 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 48 Each 81.00 3,888.00
103 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 200 Metre 102.00 20,400.00
104 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 240 Metre 145.00 34,800.00
105 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 16 Each 102.00 1,632.00
106 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 8 Set 6,884.00 55,072.00
107 3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. 80 Metre 53.00 4,240.00
(DSR) 8 Passenger Lift
108 AR Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements for MRL Type
(i) Type : Passenger Lift
(ii) Load : As Specified
(iii) (iii) Speed: 1.00 metre/sec.
(iv) (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software.
(v) Motor/machine: Permanent magnetic synchronous gearless motor.
(vi) Operation: Simplex collective selective with/without lift attendant.
(vii) Total rise: About 3 mtrs. (approx) between two stops.
(viii) Landings: All floors on same side.
(xi) Floors served: As Specified
(x) Signal : Digital Car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car.
(xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately.
(xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification
(xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS )
(xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xvi) Car door: S.S. (stainless steel) hairline finish centre /telescopic opening door.
(xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with.
(xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams.
(xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides.
(xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform.
(xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights
(xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided)
(xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car.
(xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room
(xxv) Emergencyalarm: Battery operated alarm bell system in lift car & control room ground floor
(xxvi) Position of machine room: Directly above the hoistway.
(xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V Iphase 50Hz terminated in machine room.
(xxviii) Fire man switch: Fire man switch at machine room/terminal landing
(xxix) All car panel buttons and all floor switches must be with Braille language as per lift act.
(xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed.
(xxxi) Spring buffer/hydraulic buffer shall be provided
(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.
(xxxiv) In the hoist way fascia plate shall be provided.
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level.
(xxxvi) Car top safety barricade shall be provided.
(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.
(Make:- OTIS/ KONE/ SCHINDLER/MITSHUBISHI/ THYSSENKRUPP) with 3 years free maintenance during DLP Period. Including 3rd party inspection charge.
109 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 50 Metre 246.00 12,300.00
110 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
111 7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.1 Upto 35 sq. mm (Clamped with 1 mm thick saddle) 50 Metre 43.00 2,150.00
112 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 10 Each 1,275.00 12,750.00
113 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 Set 13,721.00 27,442.00
114 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 80 Metre 144.00 11,520.00
( SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM)
115 DSR 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required 58 KWP 54,280.00 3,148,240.00
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and otheraccessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Meta OxideVaristors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
AUTOMATIC FIRE ALARM & DETECTION SYSTEM
116 DSR 28.2.1 Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
28.2.1.2 Two Loop Panel. 1 Each 250,420.00 250,420.00
28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2 Each 113,734.00 227,468.00
28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 240 Each 3,004.00 720,960.00
28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 36 Each 306.00 11,016.00
28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. 24 Each 2,787.00 66,888.00
28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required 24 Each 3,434.00 82,416.00
28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required 24 Each 3,156.00 75,744.00
28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 24 Each 4,063.00 97,512.00
SAFETY ACCESSORIES & MISC
117 NS Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969 5 Meter 2,208.00 11,040.00
118 NS Shock treatment chart in English and local language duly framed with glass 2 Nos 696.00 1,392.00
119 NS First aid box complete with all standard first aid materials 2 Nos 602.00 1,204.00
120 NS Rubber gloves 11 KV grade as per IS 4770-68 2 Pairs 401.00 802.00
Computer Networking (LAN)
121 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
122 1.27.1 Supplying and Fixing 75mmx75mm modules, GI box along with modular base & cover plate for modular fitting in recess etc as required. ( Make - Legrand/ Honeywell ) 300 Each 234.00 70,200.00
123 39.13 Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) 300 Each 173.00 51,900.00
39.13.2 Copper Patch Cords of length 3m (10ft) 300 Each 405.00 121,500.00
124 DSR 39.23.1 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
125 DSR 39.23 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
126 DSR 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 15 Each 5,278.00 79,170.00
127 NS Supply, Installation, Testing & Commissioning of Ethernet Managed Switch with fiber Module Along with AC Power Supply: 24 x 10/100/1000BASE-T ports, 4 x Gigabit RJ45/SFP Combo ports, Advanced L2 switching and security features, L2+ Static Routing, Optional “standard mode” or “surveillance mode” management user interface etc as required. ( Make - D-Link/ Netgear/ Mortek/ HP) 15 Each 20,758.00 311,370.00
128 NS Supply installation testing & commissioning of Ethernet Unmanaged Switch Without fiber Module Along with AC Power Supply: 24x10/100/1000 Base T LAN switch including necessary connection of CAT 6 UTP cable etc as required. ( Make - D-Link/ Netgear/ TP-Link) 15 Each 19,070.00 286,050.00
129 1.58 Supplying and drawing UTP 4 pair CAT-6 PVC insulated and sheathed LAN cable through existing PVC conciuit including connection, testing etc. as required. ( D-Link )
1.58.1 1 run of cable 9250 Point 52.00 481,000.00
130 NS Supplying and fixing of tooless RJ 45 information for CAT 6 U/UTP white colour Arteor Modules 1 along with built in crimping handfree min 5 times reconnection possible and shutter protection etc as required. ( Make - Legrand/ Honeywell/ Eqv. ) 300 Each 545.00 163,500.00
Total Rs. 18,872,708.00
Such Type of 2 Unit Rs. 37745416.00
Part-'C' Teachers Quaters Building (G+5)
131 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder point 268
T/L light point 216
Ceiling fan point 112
Exhaust fan point 66
Call Bell point 22
132 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 111 Each 414.00 45,954.00
133 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 157 Each 531.00 83,367.00
134 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 1880 Meter 309.00 580,920.00
135 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.(use for AC box) 67 Each 683.00 45,761.00
136 1.57 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 4 nos. 5 pin 5/6 amps modular socket outlet and 4 nos. 5/6 amps modular switch, connection etc. as required.(use for computer point) 45 Each 1,064.00 47,880.00
137 1.55 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 22 Each 632.00 13,904.00
138 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(for CKT & 2 Nos 5 A Socket) 2100 Meter 201.00 422,100.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(for Comp and Street Light) 680 Meter 246.00 167,280.00
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(for AC) 804 Meter 309.00 248,436.00
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 288 Meter 422.00 121,536.00
1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire(for powr DB + 63 A DP) 745 Meter 557.00 414,965.00
139 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
140 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door 45 Each 2,314.00 104,130.00
141 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 450 Each 237.00 106,650.00
142 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 316 Each 64.00 20,224.00
143 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 268 Each 80.00 21,440.00
144 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.5 12 watt LED lamp 268 Each 239.00 64,052.00
145 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 22 Each 351.00 7,722.00
146 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 216 Each 521.00 112,536.00
147 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
148 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
149 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
150 1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required. 40 Each 34.00 1,360.00
151 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 112 Each 358.00 40,096.00
152 DSR 9.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 112 Each 2,695.00 301,840.00
153 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
154 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole 22 Each 4,463.00 98,186.00
155 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
156 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.1 100 A, 30 KA, FPMCCB (for Lift, One Spare) 2 Each 8,172.00 16,344.00
157 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (Two spare, One for Building Light) 25 Each 1,198.00 29,950.00
2.13.4 40 A to 63 A, four pole (One for Campus Light) 1 Each 2,324.00 2,324.00
158 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
159 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) with metering Space 42 Sq.ft. 1,809.00 75,978.00
160 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 15 P/Kg 871.00 13,065.00
161 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6,536.00 6,536.00
162 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
163 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.3 Above 95 sq. mm and upto 185 sq. mm 100 Metre 336.00 33,600.00
164 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
165 3.21 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 Set 6,884.00 13,768.00
166 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 40 Metre 144.00 5,760.00
Lighting Arrester
167 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 8 Each 416.00 3,328.00
168 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 24 Each 81.00 1,944.00
169 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 180 Metre 102.00 18,360.00
170 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 160 Metre 145.00 23,200.00
171 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 16 Each 102.00 1,632.00
172 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 4 Set 6,884.00 27,536.00
173 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 80 Metre 144.00 11,520.00
(DSR) 8 Passenger Lift
174 AR Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD). All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis. Conforming to NBC/statutory norms and fulfilling following requirements (for MRL Type)
(i) Type : Passenger Lift
(ii) Load : As Specified
(iii) (iii) Speed: 1.00 metre/sec.
(iv) (iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software.
(v) Motor/machine: Permanent magnetic synchronous gearless motor.
(vi) Operation: Simplex collective selective with/without lift attendant.
(vii) Total rise: About 3 mtrs. (approx) between two stops.
(viii) Landings: All floors on same side.
(xi) Floors served: As Specified
(x) Signal : Digital Car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car.
(xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately.
(xii) Guide rail: As per manufacturer's specification. (xiii) Lift & car size: As per manufacturer's design and as per CPWD specification
(xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS )
(xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).
(xvi) Car door: S.S. (stainless steel) hairline finish centre /telescopic opening door.
(xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with.
(xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams.
(xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides.
(xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform.
(xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights
(xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided)
(xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car.
(xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room
(xxv) Emergencyalarm: Battery operated alarm bell system in lift car & control room ground floor
(xxvi) Position of machine room: Directly above the hoistway.
(xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V Iphase 50Hz terminated in machine room.
(xxviii) Fire man switch: Fire man switch at machine room/terminal landing
(xxix) All car panel buttons and all floor switches must be with Braille language as per lift act.
(xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed.
(xxxi) Spring buffer/hydraulic buffer shall be provided
(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.
(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.
(xxxiv) In the hoist way fascia plate shall be provided.
(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level.
(xxxvi) Car top safety barricade shall be provided.
(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.
(Make:- OTIS/ KONE/ SCHINDLER/MITSHUBISHI/ THYSSENKRUPP) with 3 years free maintenance during DLP Period. Including 3rd party inspection charge.
175 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(for CKT) 20 Meter 201.00 4,020.00
176 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 6 Each 1,275.00 7,650.00
177 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
178 7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.1 Upto 35 sq. mm (Clamped with 1 mm thick saddle) 50 Metre 43.00 2,150.00
179 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 Set 13,721.00 27,442.00
180 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 50 Metre 144.00 7,200.00
( SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM)
181 DSR 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required 15 KWP 54,280.00 814,200.00
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and otheraccessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Meta OxideVaristors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
AUTOMATIC FIRE ALARM & DETECTION SYSTEM
182 DSR 28.2 Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
28.2.1.2 Two Loop Panel. 1 Each 250,420.00 250,420.00
28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2 Each 113,734.00 227,468.00
28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 90 Each 3,004.00 270,360.00
28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 18 Each 306.00 5,508.00
28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. 12 Each 2,787.00 33,444.00
28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required 12 Each 3,434.00 41,208.00
28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required 12 Each 3,156.00 37,872.00
28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 12 Each 4,063.00 48,756.00
SAFETY ACCESSORIES & MISC
183 NS Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969 3 Meter 2,208.00 6,624.00
184 NS Shock treatment chart in English and local language duly framed with glass 1 Nos 696.00 696.00
185 NS First aid box complete with all standard first aid materials 1 Nos 602.00 602.00
186 NS Rubber gloves 11 KV grade as per IS 4770-68 1 Pairs 401.00 401.00
Total Rs. 8,454,328.00
Part-'D' Staff Quaters Building (G+3)
187 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
Batten Holder Point 64
T/Light point 64
Ceiling fan point 24
Exhaust fan point 24
Call Bell point 8
188 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 40 Each 414.00 16,560.00
189 1.55 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. (multy point) 32 Each 632.00 20,224.00
190 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 40 Each 531.00 21,240.00
191 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. 440 Meter 309.00 135,960.00
192 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.(use for AC box) 16 Each 683.00 10,928.00
193 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(for CKT) 485 Meter 201.00 97,485.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(for Street Light & 2 nos 5 A Socket) 410 Meter 246.00 100,860.00
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(for AC) 192 Meter 309.00 59,328.00
1.7.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire(for light DB) 100 Meter 422.00 42,200.00
1.7.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire(for Power DB + 63A DP GND Floor) 278 Meter 557.00 154,846.00
194 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
195 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.7 12 way, Double door 16 Each 2,314.00 37,024.00
196 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 160 Each 237.00 37,920.00
197 1.33 Supplying and fixing 2 pin, 5/6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 105 Each 64.00 6,720.00
198 1.34 Supplying and fixing batten/ angle holder including connection etc. as required. 64 Each 80.00 5,120.00
199 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.5 12 watt LED lamp 64 Each 239.00 15,296.00
201 1.38 Supplying and fixing electronic musical call suitable for single phase, 230 volts complete bell as required. 8 Each 351.00 2,808.00
202 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 64 Each 521.00 33,344.00
202 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
203 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
204 8.4 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
205 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/ switch box including connections but excluding modular plate etc. as required. 24 Each 358.00 8,592.00
206 DSR 9.2 Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 0.00
9.2.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 24 Each 2,695.00 64,680.00
207 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
208 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
2.1.3 63 Amp, double pole 8 Each 4,463.00 35,704.00
209 2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
210 2.6 Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required.
2.6.2 63 A, double pole 8 Each 4,418.00 35,344.00
211 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
212 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole (2 spare, 1 for Building Light, 1 for Campus Light) 12 Each 1,198.00 14,376.00
213 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
214 8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) with metring Space 24 Sq.ft. 1,809.00 43,416.00
215 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 8 P/Kg 871.00 6,968.00
216 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6,536.00 6,536.00
217 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.9 50 sq. mm, 3.5 core (Gen Set) 80 Metre 561.00 44,880.00
218 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 160 Metre 326.00 52,160.00
219 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
220 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 2 Set 16,675.00 33,350.00
221 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 40 Metre 144.00 5,760.00
Lighting Arrester
222 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 8 Each 416.00 3,328.00
223 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 32 Each 81.00 2,592.00
224 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 180 Metre 102.00 18,360.00
225 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 160 Metre 145.00 23,200.00
226 4.12 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required. 16 Each 102.00 1,632.00
227 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 4 Set 6,884.00 27,536.00
228 3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. 40 Metre 53.00 2,120.00
( SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM)
229 DSR 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required
a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate. 5 KWP 54,280.00 271,400.00
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and otheraccessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Meta OxideVaristors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required.
AUTOMATIC FIRE ALARM & DETECTION SYSTEM
230 DSR 28.2 Supply, Installation, Testing and Commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capabale of supporting not less than 240 devices ( including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230+_5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system(which is part of the scheduleof work under SH: PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specification.
28.2.1.2 Two Loop Panel. 1 Each 250,420.00 250,420.00
28.2.3 Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 2 Each 113,734.00 227,468.00
28.2.4 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 90 Each 3,004.00 270,360.00
28.2.5 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 12 Each 306.00 3,672.00
28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. 8 Each 2,787.00 22,296.00
28.2.7 Supplying, installation, testing & commissioning of fault isolator complete with base as required 8 Each 3,434.00 27,472.00
28.2.10 Supplying, installation, testing & commissioning of addressable fire control module complete as required 8 Each 3,156.00 25,248.00
28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 8 Each 4,063.00 32,504.00
SAFETY ACCESSORIES & MISC
231 NS Rubber mat of 16mm thik and 1000mm wide to with stand 15KV dielectric strength as per is 5424. 1969 3 Meter 2,208.00 6,624.00
232 NS Shock treatment chart in English and local language duly framed with glass 1 Nos 696.00 696.00
233 NS First aid box complete with all standard first aid materials 1 Nos 602.00 602.00
234 NS Rubber gloves 11 KV grade as per IS 4770-68 1 Pairs 401.00 401.00
Total Rs. 2,828,625.00
Part-'E' CCTV Camera (for School,boy's Hostel And Girl's Hostel)
235 40.11.2 64 Channel NVR 4K 4 SATA (CP-UNR-4K5644-V2) Description-supply, installation, testing & Commissioning of 64 Channel NVR 4K (2 for school, 2 for boy's hostel,2 for girl's hostel) 6 Nos 82,600.00 495,600.00
236 DSR 40.1 Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB, Camera should display Camera title, Date & Time in live & recorded video
2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light ompensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
3) Compression (Minimum):-Video:- H.265 or better, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming , configurable (Main stream: 2MP (1920 ×1080)@25/30 fps,Sub streams minimum: 720P@25/30 fps).
7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection
8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade, trusted boot.
9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.
10) Recording Management: Format SD, overwrite, storage management, video to NAS device
11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast
13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.
17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body
19) Operating Condition:- Ambient Temperature:- (-) 05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
40.1.1 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens (25 for school, 35 for boy's hostel,35 for girl's hostel) 95 Nos 8,048.00 764,560.00
237 DSR 40.4 Supplying Installation Testing and Commissioning of4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video
2)Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
4) Wide Dynamic Range:- WDR (120dB or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps
7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection
8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade
9) Onboard Storage: Camera should support built-inm Micro SD/ SDHC/ SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memory Card.
10) Recording Management: Format SD, overwrite, storage management, video to NAS device,
11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.
17) Power Requirement: 12VDC/24 VDC/PoE(802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
40.4.1 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) (8 for school, 10 for boy's hostel,10 for girl's hostel) 28 Nos 10,063.00 281,764.00
40.4.2 4MP @ 25/30fps@1440P (2560x1440) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. (2 for school, 2 for boy's hostel,2 for girl's hostel) 6 Each 23,754.00 142,524.00
238 NS 16- port Gigabit Unmanaged PoE switch (DS-3E0518P-E/M) Description- supply, installation, testing & Commissioning of Port POE Switch. (2 for school, 2 for boy's hostel,2 for girl's hostel) 6 Nos 10,450.00 62,700.00
239 NS 8- port PoE switch with 2 Giga Uplink (CP-DNW GPU8G296) Description- supply, installation, testing & Commissioning of 8 Port POE Switch. (3 for school, 4 for boy's hostel,4 for girl's hostel) 11 Nos 5,451.00 59,961.00
240 DSR 40.12 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
40.12.1 4TB (Terabytes) (3 for school, 4 for boy's hostel,4 for girl's hostel) 11 Nos 13,943.00 153,373.00
241 NS 6U DVR/Network Rack Description- supply, installation 6U Network Rack for Mounting NVR & POE Switch. (1 for school, 3 for boy's hostel,3 for girl's hostel) 7 Nos 5,563.00 38,941.00
242 NS 2U DVR/Network Rack Description- supply, installation 2U Network Rack for Mounting NVR & POE Switch. (3 for school, 4 for boy's hostel,4 for girl's hostel) 11 Nos 1,279.00 14,069.00
245 NS RJ 45 Connector Description- supply, installation, testing & Commissioning of RJ4 Connector for connection between CCTV Camera and POE Switch (100 for school, 150 for boy's hostel,150 for girl's hostel) 400 Nos 25.00 10,000.00
246 NS Cat-6 PVC insulated and sheathed LAN cable. Description- supply and drawing UTP 4 Pair Cat-6 PVC Insulated and sheathed LAN cable through existing PVC conduit including connection, testing etc required. (1400m for school, 1645 for boy's hostel,1645 for girl's hostel) 4690 Meter 40.00 187,600.00
247 NS LED TV 55" 4K UHD (65AU7700) Description- supply, installation, testing & Commissioning of Samsung 65" 4K UHD TV for live view. (1 for school, 1 for boy's hostel,1 for girl's hostel) 3 Nos 85,057.00 255,171.00
Total Rs. 2,466,263.00
Part-'F' Campus light and Feedar Panel Work.
248 8.22 Supply and erection of 4 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
8.21.1 Single arm, 1000 mm (8 octagonal pole for Badminton Court) 38 Each 19,292.00 733,096.00
249 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
250 9.16 Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
9.16.1 For 4 metre pole (500mm X 500mm X 1000mm) 63 Each 3,305.00 208,215.00
251 1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
252 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.7 25 sq. mm, 3.5 core (for feeder) 140 Metre 346.00 48,440.00
253 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
254 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
255 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.3 40 A to 63 A, double pole 3 Each 1,198.00 3,594.00
256 8.12 Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.) (6 sq feet for Badminton Court) 12 Sq.ft. 2,261.00 27,132.00
257 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire 2 Meter 925.00 1,850.00
258 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 4 P/Kg 871.00 3,484.00
259 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 1 Each 6,536.00 6,536.00
260 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 Set 6,884.00 13,768.00
261 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 30 Metre 144.00 4,320.00
Outdoor feeder Panel Work
262 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
2.4.1 100 A, 30 KA, FPMCCB (Campus Light) 2 Each 8,172.00 16,344.00
2.4.6 250 A, 50 KA, FPMCCB (Two Spare) 3 Each 19,613.00 58,839.00
2.4.7 400 A, 50 KA, FPMCCB (One Spare) 4 Each 45,651.00 182,604.00
263 A/R SITC of ACB with microprocessor release with overload, short circuit neutral protection instantaneous ground fault protection (LSING) LES icU lew for Isec four total selectivity ambient temperature 50 dig, C in with breaking capacity of 50KA/60KA 800 A Capacity.
4 Pole 415 Volts conforming to IS/OEC : 60947-2 2 Each 179,604.00 359,208.00
264 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.4 40 A to 63 A, four pole (Spare) 2 Each 2,324.00 4,648.00
265 8.12 Supply and fixing fabricated Feeder pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator, with 40mm X 40mm X 5mm angle iron stand and complete in all respect etc and must be CPRI approved panel manufactures. (But without RYB LED lamp, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears, PCC work etc.) for 2 Outdoor Feeder Panel 36 Sq.ft. 2,261.00 81,396.00
266 A/R S/F copper Strip 50 mm X 5 mm sizes for bus-bar including interconnection etc. as reqd. 30 P/Kg 871.00 26,130.00
267 8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. 2 Each 6,536.00 13,072.00
268 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.17 400 sq. mm, 3.5 core (Double Run) 320 Metre 3,497.00 1,119,040.00
269 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.4 Above 185 sq. mm and upto 400 sq. mm 220 Metre 368.00 80,960.00
270 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
271 8.3 Providing and making steel pole collar with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 stone aggregate 20 mm ) of specified size and shapeincluding form work, plastering if required, curing etc. as required. (volume of pole/pipe not to be deducted) 2 Cum 7,501.00 15,002.00
272 3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 4 Set 16,675.00 66,700.00
273 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 80 Metre 144.00 11,520.00
Total Rs. 4,586,049.00
Part-'G' D.G set, Transformer/Compact Substation
SITC OF D.G Set & COMPACT SUBSTATION.
274 DSR 29.1 Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
(A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of ontinuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. 217 DELHI SCHEDULE OF RATES (E&M)-2025
(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable onnection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set
7. Fuse/ MCB for instruments
8. Battery charger, complete with transformer/ rectifier, 218 DELHI SCHEDULE OF RATES (E&M)-2025 D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
9. Main supply failure monitor 10. Supply failure timer 11. Restoration timer
12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator
15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
275 9.1 Providingang and laying in position reinforced cement concrete 1 : 2 : 4 (1 : cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of pump, DG set etc including form work etc. as required. (excluding reinforcement) for Genset , Plinth) 3.0m X 2.8m X 2m = 15 cum) 30 Cum 8,721.00 261,630.00
276 N/S SITC of 11 KV/433V, 500 KVA outdoor type compact sub-station with Oil type Transformer HT - 11KV, 630A, 21KA/3sec Ring main units (CV)- one no. Manual operated Load Break switch + 1 no Manual operated VCB transformer ONAN type-Losses as per latest amendment 2021 of IS 1180 LT-800 amps, 50 KA fixed manual ACB incomer with microprocessor release 630 amps -2/3/4 nos. OG fixed manual 36KA MCCB Microprocessor release as per site requirement. 2 Set 3,975,284.00 7,950,568.00
277 9.1 Providingang and laying in position reinforced cement concrete 1 : 2 : 4 (1 : cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of pump, DG set etc including form work etc. as required. (excluding reinforcement) for Transformer , Plinth) 4 .5m X 3m X 2m = 27 cum) 54 Cum 8,721.00 470,934.00
HV CABLE SUPPLY, LAYING, JOINTING & TERMINATONS
278 7.8 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
279 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.5.2 Above 120 sq. mm and upto 400 sq. mm 170 Metre 431.00 73,270.00
280 DSR 23.4 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
281 DSR 23.5 Supplying and making outdoor cable end termination with heat hrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
FIRE SUSPESSION SYSTEM
282 N/S Supply, installation, testing & Commissioning of 5.0 LB Noves 1230/FK-5-1-12 8 Each 150,087.00 1,200,696.00
283 N/S Supply fixing testing & Commissioning Lienear pneumatic heat Detection Tube 120 Metre 3,684.00 442,080.00
284 N/S Supply fixing testing & Commissioning of Master Control unit for controling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make each entier system functional. 8 Each 27,289.00 218,312.00
Total Rs. 14,897,932.00
Part-A School Building (G+2) Rs. 9,506,231.00
Part-B Boy's/Girl's HOSTEL Building (G+5) Rs. 37,745,416.00
Part-C Teachers Quaters Building (G+5) Rs. 8,454,328.00
Part-D Staff Quaters Building (G+3) Rs. 2,828,625.00
Part-E CCTV Camera (for School,boy's Hostel And Girl's Hostel) Rs. 2,466,263.00
Part-F Campus light and Feedar Panel Work. Rs. 4,586,049.00
Part-G D.G set, Transformer/Compact Substation Rs. 14,897,932.00
Total (Electrical Work) Rs. Total 80,484,844.00
Total (Civil+Electrical) Work ₹ 561,069,093
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT 04 2026-27.pdf
NIT • 3.15 MB
04 SBD 2026-27 PAPER CUTTING.pdf
NIT • 0.85 MB
RETENDR 04 SBD 720 BED CORRINGDUM.pdf
NIT • 0.50 MB
61631_7974 UDIN.pdf
NIT • 2.18 MB
60644_20417_Check list forwarding.pdf
NIT • 1.76 MB
58144_Letter No 3183 Dated 3-6-2020.pdf
NIT • 1.08 MB
55685_Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
54865_Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
61769_20452_JointVentureGuidelines.pdf
NIT • 2.48 MB
63740_9417 10 Below.pdf
NIT • 3.35 MB
69542_5768 10.pdf
NIT • 6.90 MB
work comletion period circular.pdf
NIT • 0.80 MB
RE NIT 04 26-27.pdf
NIT • 7.35 MB
GCC Document NIT 04.doc
NIT • 0.60 MB
BOQ 720 Beded SC_ST Hostel at Marhaura.xlsx
NIT • 0.43 MB
C1 RETENDR 04 SBD 720 BED CORRINGDUM.pdf
Corrigendum • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].