Tender Value
Refer Docs
EMD Value
₹8.6 L
Closing Date
26 May 2023, 5:00 pmClosed
Superintending Engineer
SUPERINTENDING ENGINEER, CONSTRUCTION CIRCLE, UTTARAKHAND PEYJAL NIGAM, PAURI GARHWAL
Tender for construction Surveying, Design Supply, Cartage laying Jointing of GI API Pipe of 15mm to 80mm dia by Socketing Electric arc welding, RCC Circular CWR 2 KL - 40 KL Capacity, Pump House other appurtenent works under Jhavana G.O.V Pumping W
2023_MDPEY_58315_1
1561/Nivida Quotaion/302 Dated 08-05-23
Open Tender
Civil Construction Goods
Item Rate
365 days
Dugadda
As Per Tender Document
3 documents required · 3 mandatory
₹5,900
Executive Engineer, C.D. Peyjal Nigam Kotdwar
₹8.6 L
kotdwar
26 Sept 2023
11 May 2023
29 May 2023
11 May 2023
26 May 2023
16 May 2023
11 May 2023 - 15 May 2023
15 May 2023
Amount
Supply of all materials, labour T&P etc complete and construct pump house (5.5 x5.0 x4.5 M) size as per approved designed & drawing including all necessary arrangements.
Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.50m in width or 10.0sqm in plan) including dressing of sides and ramming of bottoms, lift up to 1.50m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m in all kinds of soil.
Excavation in soil mixed with single boulders etc. requiring the use of special T&P, if any, for pipe line trenches including lift up to 1.5m and lead up to 30m with back filling, watering, ramming of excavated earth in the trenches.
Same as item No. 3 (a) above but excavation in decomposed, weathered or soft rock by blasting or by drawbars, pickaxes etc. or by both methods, including supply of all materials, labour, T&P etc.
Supply, Carting (site store to trench) , Painting , lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line by welding for making up lengths as required for proper completion of work of following grade & sizes ((Excluding cartage from Rail Head to site store.) API 5L/ ISO: 3183
65 mm dia, 4.8 mm thick
80mm dia, 4.8 mm thick
Survey, design, supply carting, laying & jointing of G.I.(M) pipe by socketing for Supply Main/ Feeder Main/Distribution System of following sizes including provision of specials and other appurtenant works such as scouring arrangement at suitable locations by fixing tee etc. complete and also testing & commissioning of laid pipeline including supply of all materials, labour, T&P etc. complete. G.I. (Medium Quality) As per IS 1239 Part I : 2004
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Survey, design, supply carting, laying & jointing of G.I.Heavy class pipe by socketing for Supply Main/ Feeder Main/Distribution System of following sizes including provision of specials and other appurtenant works such as scouring arrangement at suitable locations by fixing tee etc. complete and also testing & commissioning of laid pipeline including supply of all materials, labour, T&P etc. complete. G.I. (Heavy Duty) As per IS 1239 Part I : 2004
32 mm dia
Dismantling& Relaying of 20mm dia screwed and socketed G.I. Pipes, specials and fittings including taking out of dismantled G.I. pipes and specials from trenches and stacking them properly within 50.00m but excluding the cost of earth work
Providing and fixing of PTMT bib cock 15 mm dia. nominal bore for domestic connections.
Providing and fixing brass ferrule 15mm dia. nominal bore for domestic connections.
Supply and fixing of the following fittings including cartage of materials , labour , T & P etc complete but excluding the cost of excavation and chamber. G.M. Wheel valve (Class I) as per IS 778/1971
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
Supply, cartage and fixing of following size of Sluice Valve/Reflux valves/Double Ball Air Valve including carting the same up to site of work and fixing the same in water supply lines including cost of valves, specials, labour an T&P complete in all respect as per direction of Engineer-In-Charge.
65 mm dia. Cast steel Sluice / Scour Valve, W.P. 50 Kg/cm2
80 mm dia. Cast steel Sluice / Scour Valve, W.P. 50 Kg/cm2
65 mm dia. Cast steel Reflux / Swing Check Valve, W.P. 50 Kg/cm2
80 mm dia. Cast steel Reflux / Swing Check Valve, W.P. 50 Kg/cm2
50 mm dia. Cast steel Double Ball Air Valve Flanged type, W.P. 25 Kg/cm2
Supply, cartage and fixing of screwed Air valves 15 mm dia, including supply of all labour, material, T&P etc.complete.
Construction stone masonry Wheel Valve / Air valve chamber 60x60x60 cm, inside in 1:4 cement & sand mortar with MS MH cover on top the chamber with proper locking arrangement.
Supply of all materials, labour, T & P etc. and Construction of Thrust Block as per type design complete (1 in 200 m length Pipeline)
Size of Anchor Block- 0.8 x 0.8 x 1m
Size of Anchor Block- 0.8 x 0.8 x 1.3m
Random rubble stone masonry in 1:6 cement and local sand mortar for protection work on pipe line, treatment site & where ever required as per site requirement including supply of all materials T&P etc required for proper completion of work as per direction of Engineer-In-Charge.
Random rubble masonry laid dry in breast walls, retaining walls etc. including supply of all material, labour, T&P and royalties etc. complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing & laying PCC 1:2:4 in cement, coarse sand and 20 mm gauge approved stone ballast, including supply of all materials, labour , T&P etc
Provision of 1.5 m high Boundary Wall( At TW & IPS) in brick masonry including supply of all materials, labour, T&P etc. complete.
Supply & Fixing Iron Gate with Pillers of Size 1.00 m wide (Clear Size) including locking arrangement including Supply of all accessories fixing arrangement in all repect complete.
Supply of all materials , labour and T & P etc. and construction of R.C.C Clear Water Reservoir of following capacity in K.L as per type design and drawing including fixing of pipes and fittings including cartage of materialls etc. complete also including supply & fixing of bucket type chlorinator on each CWR.
40.00 Kl capacity clear water Sump at TOP CWR
20.00 Kl capacity clear water Sump at IPS
12.50 Kl capacity clear water reservoir
7.50 Kl capacity clear water reservoir
5.00 Kl capacity clear water reservoir
2.00 Kl capacity clear water reservoir
Repairing of Existing RCC CWR including grouting, plastering inside and outside, coloring, MH cover etc.
20 KL Capacity
10KL Capacity
7.5 KL Capacity
Supply & Fixing an Iron Board and Printing on it as well as writing the details of Work on it.
Dismantling of cement concrete road pavement for laying different sizes of pipes, stacking the serviceable materials and disposal of waste materials upto a distance of 50 m including supply of materials, labour, T&P etc. complete.
Transportation of suitable truck mounted drilling machine with all necessary accessories connecting T&P required for drilling and correction of including leveling etc. complete with all respect as per direction of the Engineer in charge.
Drilling of bore size attachment required drilling in alluvial, bolder ,pebbles gravels. Rocky stone sticky clay etc. including cost of attachment consumable store bits ,water pole etc. complete 250 casing pipe which will be welded together using 2.5 or 3.25 mm dia advani Oerlinkon electrodes with plain end and the other end chamfered to 50 degree removing pint in the area to be welded inclusive on the cost of bio chargeable degradable and non toxic from flush etc. complete with all respects as per direction of the Engineer in charge.
Supply of 250 mm dia 7.1 mm thick MS ERW casing pipe from approved manufacturers complete with all respects confirming IS 4270.
Supply of 250 mm dia 7.1 mm thick MS ERW slotted pipe conforming IS 4270.
Development of tube well by air compressor.
Development of tube well by O.P. Unit
Supply and fixing of 250 mm dia size M.S. tube well cap.
Submersible Pumping Plant- Supply of submersible pump set having discharge 220 lpm. Of 225 mtr. Head 3 phase 415V±10%, 50C/s with motor complete in all respects.
Starter cum panel suitable for Above Pump set
Main switch 100 Amp
10 sq.mm three core submersible cable for above pumping plant.
70 sq.mm al armoured 3.5 core cable.
Main piping and valves- Complete As per Site Requirement
Pressure gauge with control cock & fitting of range 0.20 kg/cm2 with complete with all fitting
Tools - As per Site requirement
Chain Pully block of 2 tone capacity 4.5 mtr lift complete in all respect.
Rubber Resistance sheet
Installation, Testing & commissioning of pumping Plant with lowering of column pipe and fixing of valve and accessories.
Earthing as per site requirement
Painting as per site requirement
Testing of Water Sample.
MPS- Supply of electric driven multi-stage horizontal clear water centrifugal pumps with bronze impellers, stainless steel shaft capable to deliver clear water 140 LPM discharge at 440 Mt. head, 2900 r.p.m.
Base Plate
TEFC Electric motors suitable to run Above pump
Control Pannel as per site requirement
Fully automatic auto transformer type starter suitable for above motors
16 sq.mm. 3 Core copper conductor cable XLPE insulated cable
70 sq.mm.3½ Core aluminum conductor cable XLPE insulated, cable
Jointing material
Double loop earting of all electrical equipments as per site requirement
Main piping & valves complete as per site requirement
Pressure gauges
Supply of Chain Pully block of 2 tone capacity 4.5 mtr lift complete in all respect.
Tools - As per Site requirement
Rubber Insulation sheet
Installation and setting to work of entire equipment including pumps, motors, control panel , starter and power wiring etc.
Commissioning of pumping plant at site.
Testing of pumps At works.
Testing of pumps At Site.
Painting
Automation of Tube well- GSM based remote terminal units
GSM based wireless communication hardware for RTU’s.
Intelligent Energy meters suitable for automation.
Valve Actuator for 80 mm dia valve.
Actuator Panel
Hard wired timer circuit for actuator
Auto phase reversal unit 0-40 H.P.
Pressure Transmitter
Isolation Transformer (440 V step down 220 V for protection of site automation)
Electromagnetic Flow meter for line size 80 mm
Single cabling between RTU and field instruments, 2 Core x 1.5 sqmm PVC coated flexible screened cable.
4 C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
10C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
Conduit pipe 1” PVC
Conduit pipe 1.5” PVC
Accessories like conduit pipe flexible pipes, PVC bend, AC & DC relays with base, lugs etc.
Erection commissioning of all instruments and customization of software.
Automation for MPS - GSM based remote terminal units
GSM based wireless communication hardware for RTU’s.
Intelligent Energy meters suitable for automation.
Valve Actuator for 80 mm dia valve.
Actuator Panel
Hard wired timer circuit for actuator
Auto phase reversal unit 0-40 H.P.
Pressure Transmitter
Isolation Transformer (440 V step down 220 V for protection of site automation)
Electromagnetic Flow meter for line sizes - 80 MM
Single cabling between RTU and field instruments, 2 Core x 1.5 sqmm PVC coated flexible screened cable.
4 C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
10C x 1.5 sq mm PVC coated flexible unscreened Cu cable.
Conduit pipe 1” PVC
Conduit pipe 1.5” PVC
Accessories like conduit pipe flexible pipes, PVC bend, AC & DC relays with base, lugs etc.
Erection commissioning of all instruments and customization of software. Tube well & mps
Cost of External & Internal electrification of pump houses and campus at Tube well
Cost of External & Internal electrification of pump houses and campus at M.P.S
After testing & commissioning of scheme running & maintenance of scheme by running pumping plant for 8 hrs per day (for a period of 6 months or complete Distribution line testing of civil works which over later ) including supply of skilled O&M staff, account maintenance including supply of all materials, labour, T&P etc. complete but excluding electricity charges for pumping of water.
M/S MANOJ KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .