| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹6.7 L+₹66,888.50 (11.1%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹6.7 L+₹71,388 (11.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹6.8 L+₹75,365 (12.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹6.9 L+₹91,770 (15.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
17 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SAMBA
GE SAMBA
SUNKEN TREATMENT AND ALL ITS CONNECTED WORKS IN ZONE II AND ZONE III AT MIL STN SAMBA
2023_MES_603724_1
GE/SMB/T-33/2023-24
Open Tender
Civil Works - Highways
Item Rate
180 days
SAMBA
REF NIT
8 documents required · 8 mandatory
₹500
Yes
GE SAMBA
₹20,000
Yes
23 Oct 2023
17 Jun 2023
19 Jul 2023
17 Jun 2023
17 Jul 2023
3 Jul 2023
17 Jun 2023 - 20 Jun 2023
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for ,complete all as specified and directed.
Demolition of reinforced cement concrete of any description ground to 2nd floors and removing the rubbish from the work site out side defence premises, complete all as specified and as directed.
Complete removing of existing tretment and Cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setting upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with Shalipatch or equivalent make as approved by GE cold applied.Bituminous mortar and cold emulsion cum water proofing liquid of Shalikote-T-10 or equivalent make as approved by GE, created SSD condition on surface with water. Prime the surface with Tarfelt LM or equivalent make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of Tarfelt LM or equivalent make as approved by GE having alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm. Lay Geotex of 45 GSM/fiber mesh simultaneously and paste it properly with overlap of 50mm.
Discription count down as per srl item no 3.00 Allowed of first coat to dry for 10 to 12 hrs. Apply 2nd coat on cured first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller. Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of U V Resistand Elastomeric Exterior Axcrylic weather resistant water proof coating of Shalicryl - 215 or eauivalent make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083, for U V protection of bituminous Elastomeric Acrylic emulsified liquid membrance of Tarfelt LM or equivalent make as approved by GE to give long life and prevent its deterioration from sunlight. Note : Application of water proofing treatment will be done by authorised applicator only.
Rendering 10 mm thick in CM 1:3 on concrete surfaces and finished even and smooth without using extra cement in sunken /roof slab , complete all as specified and as directed.
Plain Cement concrete 1:7:12 type F-2 (using 40 mm graded stone aggregate) as in sunken filling and mass concrete, complete all as specified and directed
Taking down cement plaster on brick/concrete surfaces or stone walls, ceiling, etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed .
Rendering 10 mm thick cement plaster in cement mortar 1:6 on on brick /stone/concrete surfaces finished even and smooth without using extra cement , complete all as specified and directed.
Rendering 15 mm thick cement plaster in two layers 5 mm thick over and including 10 mm thick in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement (upto 2nd storey with necessary scaffolding) ,complete all as specified and directed.
Rendering 5 mm thick on concrete surfaces in CM 1:3 on ceiling finished even and smooth without using extra cement , complete all as specified and directed .
Dismanting of floor hearth or wall tiling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises , complete all as specified and directed.
Non-skid Coloured ceramic tiles (1st quality) 7 to 8 mm thick(square/rectangular joint free) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a layer of mortor 15 mm thick in CM 1:4, complete all as specified and directed
Non-skid Coloured ceramic tiles (1st quality) 7 to 8 mm thick(square/rectangular joint free) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a layer of mortor 15 mm thick in CM 1:4, complete all as specified and directed
Glazed coloured digital ceramic tiles (1st quality) joint free in vertical surfaces of wall of size 450x300x7mm / 450x300x7 mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:3 on brick /concrete surfaces complete all as specified and directed .
Taking down shutter of any description exc 1.00 Sqm but not exc. 2.0 sqm each and refixing in the same opening.complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.5 square metre each including cutting holes for taking out hold fasts of dismantling brick work ( holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed.
Factory made solid PVC door frame of size 50x47mm made out of 5mm thick prelam PVC sheet with one or more rebate reinforced with MS square tube, fixed in opening as per specification & drawing No CEPZ/TD-378/11 sheet No 1/1, etc complete all as specified and directed.
Factory made Solid panel PVC Door Shutter, 30mm thick (style),consisting of frame made of M.S. tubes for top & bottom rails M.S. frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles & rails with suitable PVC sheet beadding and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
Taking down GI pipe 15 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
G.I. pipe 15 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
G.I. pipe 15 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors, but except pipe complete all as specified and directed
Taking down GI pipe 20 mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
G.I. pipe 20 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors complete all as specified and directed
G.I. pipe 20 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors, but except pipe complete all as specified and directed
G.I. pipe 40 mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling or laid in floors as in spout of sunken floor, fixed in repair, complete all as specified and directed
25 mm thick cement concrete 1:2:4, Type B-1 (20 mm graded stone aggregate) as in sub-base of floor for tiles/Kota stone finished even & rough, complete all as specified and directed
Vitreous china ,Squatting pan 'Orissa' pattern size 580x440mm white with integral foot rest including all joints and making good to the floor etc fixed in repair ,complete all as specified and directed.
Vitreous china wash down water closet pan padestal pattern white, excluding fixing bolts, flushing cistern but including flush pipe, seat and cover, fixed in repairs complete all as specified and directed.
PVC valveless, 10 ltrs, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, fixed in repair, complete all as specified and directed
Cutting chases,pining in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing steps, cills, sunshades ,shelves,lintels,etc.; and cutting chases for concealed water tubing or concealed conduit,wiring,etc,and making good cutting not exceeding 10 cm girth in brick walls. complete all as specified and directed.
Preparation of new plastered/ concrete surfaces of walls and applying two coats of cement based paint over and including one coat of primer, complete all as specified and directed by Engr-in-charge.
Preparation of old decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etc and applying two coats of cement base paint on walls, pillars, cornice etc (upto 2nd storey with necessary scaffolding complete all as specified and directed.
Preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over a coat of chalk whiting, complete all as specified.
Preparation of new plastered or unplastered surfaces of walls and applying three coats of white washing complete all as specified and as directed .
Preparation of old plastered surfaces of ceiling including brooming down or steel wire brushing, screpping down smoke root etc and applying one coat white wash on old decorated surfaces complete all as specified and directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash , complete all as specified and as directed.
Preparation of old plastered surfaces of ceiling including brooming down or steel wire brushing, screpping down smoke root etc and applying one coat white wash on old decorated surfaces complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Preparing existing surface of floor and brushing neat cement slurry with 3.0 kg of cement per sqm (b) Rendering 15mm thick in Cement mortar (1:4) on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (c) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (d) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface.
Cound down description as per srl item no. 38.00 (e) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slope from lowest line of sloping roof towards ridge. (f) Over the APP membrane, apply a two coat of solar reflective bituminious paint on top of membrane shall be provided as prescribed by manufecturer. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed by Engr-In-Charge. Photograph of ponding shall be produced at the time of RAR. (iii) Water proofing compound rate inclding qouted rate nothing paid extra.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
PCC 1:2:4 type B-1 (using 20 mm graded stone crushed aggregate) as in roof padding, coping, bed blocks etc including preparation of surface fair without using extra cement, complete all as specified and directed.
Supply only of liquid water proofing compound ISI marked complete all as specified and directed
Cement concrete tiles 25cm x 25cm x 22mm thick machine pressed, set, jointed and pointed in neat cement slurry with gray cement in floors/roof pointed in CM 1:3 mixed with liquid water proofing compound over and including 15 mm thick screed bed in CM 1:4 , complete all as specified and directed. (WPC shall be measured and paid separetly)
Taking down cement plaster from chajjas or facias etc, incl. dismantling of damage conerete & repair the same with PCC 1:2:4 type B-0 (using 12.5mm crushed stone aggregate) on chajjas of any width and applying 10mm thick cement plaster in CM 1:3 mixed with water proofing compound, finished even & smooth using extra cement, complete all as specified and as directed. Noe- Rate quoted shall be deemed to include for scaffolding/formwork for single/double storey building of height 8.0 mtr and making good the disturbed surfaces.(Water proofing compound shall be measured & paid separately)
Rotational moulded polye- thylene water storage tanks of capacity 500 ltrs (cylindrical vertical with closed top) three layeres hoisted and fixed in position including all necessary connections all as specified in SSR Part I & including dismantling old unserviceable tank, complete all as specified and as directed.
Rotational moulded polye- thylene water storage tanks of capacity 1000 ltrs (cylindrical vertical with closed top) three layeres hoisted and fixed in position including all necessary connections all as specified in SSR Part I & including dismantling old unserviceable tank, complete all as specified and as directed.
Disconnecting existing tanks, capacity exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as directed.
Disconnecting existing tanks, capacity 1000 ltr and not exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as directed.
Cleaning and removing all scale and dirt etc, from water tanks exc. 250 and n.exc. 500 ltr capacity in any position and from mouths of circulating pipes etc and disinfection completely by making all the arrangements and writing date of cleaning on side of tanks also obtaining completion from user ,complete all as specified and directed.
Cleaning and removing all scale and dirt etc, from water tanks exc. 500 and n.exc. 1000 ltr capacity in any position and from mouths of circulating pipes etc and disinfection completely by making all the arrangements and writing date of cleaning on side of tanks also obtaining completion from user ,complete all as specified and directed.
Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 15 mm bore pipe including making connections, fixed in repair, complete all as specified and directed.
Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm bore pipe including making connections, fixed in repair, complete all as specified and directed.
20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed in repair minimum weight 20 mm size-210 gms),complete all as specified and as directed.
PVC water tank covers required for 500 ltr to 1000 ltr capacity, complete all as specified and directed.
Dismantling of CI or Concrete drain pipes up to 150mm dia, jointed in cement mortar and taking out from trenches,if required complete all as specified and directed .
Dismantling of CI or Concrete drain pipes up to 100mm dia, jointed in cement mortar and taking out from trenches,if required complete all as specified and directed .
Taking down eaves gutters and PVC rainwater / drain pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning for refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed .
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls, but except pipe, complete all as specified and directed
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, fixed to walls, but except pipe, complete all as specified and directed
PVC (SWR) 110mm bore bends any radius, complete all as specified and directed .
PVC (SWR) 110mm bore bends any radius with access door, complete all as specified and directed .
PVC (SWR) 75mm bore bends any radius, complete all as specified and directed .
PVC (SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
PVC (SWR) 75mm bore vent cowl complete all as specified and directed
PVC (SWR) 110mm bore branch piece, single (single Y) equal or unequal, complete all as specified and directed .
CP brass grating with hole 150 mm dia as per sample to be fixed with white cement, fixed in repair, complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S RAMESHWAR ENGINEERS & BUILDERS
Manminder Singh and Co
SIDDAHANT ENTERPRISES
M/S NAGAR BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .