Executive Enginner(A-I), Balurghat(A-I) Division
Uttar Chakbhabani, Balurghat, Dakshin Dinajpur
Renovation of Alipur HDTW scheme through pump house pipe line internal wiring including supply and delivery of necessary materials at Mouza Alipur JL No 290 Plot No 441 of Balurghat Block under Core Sector Programme
2026_WRDD_985904_1
WBWRDD/EE(A-I)/BLG/CORE SECTOR/17/2025-206
Open Tender
CIVIL AND ELECTRICAL WORKS
90 days
Alipur Mouza
Please refer Tender documents.
3 documents required · 3 mandatory
₹16,295
Yes
25 Feb 2026
10 Jan 2026
28 Jan 2026
10 Jan 2026
26 Jan 2026
10 Jan 2026
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof.
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. In ground floor including roof.
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Single brick flat soling of picked jhama bricks including ramming & dressing bed to proper level and filling joints with powered earth or local sand.
Cement concrete in foundation, floor and all sorts of RCC works with approved graded stone chips (20mm size) excluding shuttering & reinforcement if any, in ground floor .(a) 1:2:4 proportion.
Brick work in cement mortar(1:6) with 1st class bricks including raking out joints, scaffolding and other incidental works etc. complete.
25 mm. thick damp proof with cement concrete (1:1.5:3) (with graded stone aggregate 10 mm. normal size) and painting the top surface with a coat of bitumen [VG.40 ] using 1.7 kg. per sq.m. including heating the bitumen and cost and carriage of all materials complete.
12.5 cm thick 1st class brick work in cement mortar(1:4) in ground floor including scaffolding, raking out joints etc complete.
Hire &labour charges for shuttering with centering & necessary staging upto 4 meter using approved stout props & thick hard wood planks of approved thickness with required bracing for concrete slab beams, columns, lintels, curved or straight including fitting, fixing striking out after completion of works (upto roof of ground floor) 25mm to 30mm thick wooden shuttering.
Reinforcement for reinforced concrete work in all sorts of structure including distribution bar, stirrups, binders etc. including supply of rods, lintels, straightening of bend bars excluding coil bars & removalof loose rust (if necessary) cutting to requisite length, hooking bending to correct shape placing in proper position & binding with 1.626mm (16 SWG) black annealed wire at every enter sectioncomplete as per drawing & direction including cost of wire upto 1st floor level.ii) For Tor steel.@ 1.2% steel will be required of cement concrete . a) JSW/JSPL/SHYAM/SRMB
Cement concrete in foundation, floor and all sorts of RCC works with approved graded stone chips (20mm size) excluding shuttering & reinforcement if any, in ground floor . (a) 1:1.5:3 proportion.
M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Plaster (to wall, floor, ceiling etc.) with sand cement mortar including rounding off or chamfering corners as directed & raking out joint or roughing of concrete surface including throating, nosing 7 drip course as necessary at ground floor.i) With (1:6) cement mortar.20mm thick plaster
Plaster (to wall, floor, ceiling etc.) with sand cement mortar including rounding off or chamfering corners as directed & raking out joint or roughing of concrete surface including throating, nosing 7 drip course as necessary at ground floor With (1:4) cement morter 10 mm th. Plaster
ASF stone in floor ,dado,staircase etc. with cement concrete (4:2:1) with stone chips laid in panels as directed with topping made with ordinary white cement (as necessary) and marble dust (1:2) including smooth finishing and rounding off corners including racking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/ sqm. Including all materials and labour 25 mm th.
Neat cement punning about 1.5mm thick in wall, dado, floor drain, door & window sill etc. complete.
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification In G.L. ( two coats)
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make &brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary.
Extra rate allowed over scheduled rate for construction of pump house of HDTW considering remote places away from town @3.00% (on item no 1.04 to 1.19) i.e Rs 152974.17
Add GST@ 18.00% (On item No 1.01 to 1.2)
Add Cess@ 1.00% (On item No 1.01 to 1.21)
Supplying, fitting and fixing including transportation of Sign board of MS fabricated Structure Sheet Size 2 m x 1 m x 1.5 mm thick, MS flat bar (40 mm x 6 mm) welded with frame with 2 nos. MS Angle post (45 mm x45 mmx6mm) of 2.44 m length embeded 0.6 m into 1:2:4 Cement Concrete pasting flex on the MS Sheet ( 2 m x 1 m) as approved signage. This will include Civil construction works of foundation, Painting , material , fitting fixing and labour complete as per Drawing and direction of EIC.
Earthwork in excavation of foundation trenches or drains in all sorts of soil including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils with in a lead of 75 m. as directed trimming the sides of trenches, leveling, dressing and ramming the bottoms, bailing or pumping out of water etc. as required complete. Depth of excavation not exceeding 1.5 metre (not required shoring)
Earth work in exavation of field trenches as per designed section &alignment for laying of pipe lines (PVC,RCC,ACP etc)upto a depth of 1500 mm in all sorts of soils including removing ,spreading or stracking extra earth as directrd. The item includesnecessary trimming of side trenches levelling, dressing and ramming the bottom as required complete
Earthwork in filling in tranches after laying pipe lines (PVC,RCC,ACP etc.)with good earth obtained from exavation of field trenches in layer not exceeding 225mm, including watering &ramming etc layer by layer complete(payment will be made on the basis of measurement of finished quantity of work)
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak-proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge.(a) 200 mm Dia
Laying of P.V.C. pipes of different diameters within field trenches in curve / straight line using P.V.C. fittings, viz. Bend, Tee, Reducer etc. and making leak-proof joints with couplers after roughening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittings and solvent cement to be supplied by Deptt.) all complete as per direction of Engineer-in-Charge.140 mm Dia
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes Pakur variety
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes Pakur Variety
Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor) with cement mortar.(1:6) 20 mm. thick
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
Labour charges for fitting and fixing 150 mm dia Alfa-Alfa valve with 160 mm dia class-II UPVC riser pipe with the help of flanged PVC tail piece by joining the PVC end of Tail piece and riser pipe with coupler and flanged end of tail piece and flap valve with rubber insertion, nuts and bolts etc. complete.
Removing of Chokage due to sludge, mud, sand or any other forign materials. ii) For 200/140/11 0 mm dia PVC Pipe
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.(Delivery Connection) 150 mm. dia. ERW pipe.
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.(Delivery Connection) 150mm. dia. C.I. sluice valve.
Testing of pipe line system against leakage by filling the D.C. with water and supplying water through the entire pipe line network for at least 4 (four ) hours including hiring and transport of suitable generator, pump, tools & plants, fuel & lubricants, installation of the pump, connecting the same with pipe line network, making necessary electrical connection and dimantling all these after completion of test- all complete as per direction.
Labour charges for fitting. fixing M.S. Special bend with 160 mm X 200 mm. dia. P.V.C. reducer with the help of flanged tail-piece by joining P.V.C. end of tail-piece and 160 mm. end of reducer with coupler and flanged end of tailpiece and special bend with rubber insertion, nuts and bolts complete.
Labour charges for fitting and fixing 200mmx200mmx160 mm , 140mmx140mmx160mm, 110 mm X 110 mm X 160 mm PVC Tee with 150mm dia. M.S. extension piece by using PVC tail piece.
Extra rate allowed over scheduled rate @3.00% (on item no 2.04 to 3.3) i.e Rs 163920.20
Add GST@ 18.00% (On item No 2.01 to 3.4)
Add Cess@ 1.00% (On item No 2.01 to 3.5)
Supplying and fitting , fixing of E.I. Danger board on wall (a) 20 cm x 30 cm
Meter loop connection with 1.1 K.v. Gr. 3.5 core 14 core 10 Sqmm to 50 Sqmm p.v.C./ XLPE insulated & sheathed and armoured Aluminium/Copper Cable from Meter to incomming TPN Main Switch/Terminal. (Brand: Gloster/Havells/Finolex) (a) For DHTW/MDTW/RLI Scheme (i) 25sqmm 3.5 core Alluminium cable
Earthing with 50 mm ( 2” ) dia. G I pipe 3.64 mm thick X 3.04 mtrs. ( 10 ft. ) long and 1x 4 SWG G.I. (Hot Dip) wire ( 4 mtrs. long) 13 mm dia x 80mm. long G.I. bolts double nuts and double washers including supplying and fitting 15 mm. dia. G.I. pipe protection ( 1 mtr. long ) to be filled with bitumen , partly under the ground level and partly above the ground level driven to an average depth of 3.65 m below the ground level and restoring the surface duly by ISI Medium G.I Pipe By ISI -Medium G.I. Pipe
Supplying and fixing earth bushbar of galvanized (Hot Dip) M.S. flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the bushbar complete with G.I. bolts , nuts , washers , spacing insulators etc. as required for tapping.
Connecting the equipments to earth bushbar including supplying and fixing G.I (Hot Dip) wire of size as below on wall / floor with staples buried inside wall / floor as required and making connection to equipment with bolts , nuts , washers , cable lugs etc. as required and mending good all damages.Solid G.I. wire (iii) No. 8 SWG
Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unshealhed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' ( Precision make ) including necessary fittings as required a) 2 x 84/0.3 (6 sqmm) +1 x 56/.03(4 sq mm) ECC
Distribution wiring in 1.1 KV grade 2 x 22 / 0.30 ( 1.5 sq. mm ) single core stranded ‘ FR ’ PVC insulated and unsheathed copper wire ( Brand approved by EIC ) in suitable size PVC casing capping ( precision make ) with 1 x 22 / 0.30 ( 1.5 sq mm ) single core stranded ‘FR ’ PVC insulated and unsheathed copper wire for ECC including necessary PVC clips ,fittings etc. to light / fan / call bell point with piano key type switch ( Anchor make ) fixed on sheet metal fabricated switch board with Perspex / Bakelite top cover on wall including necessary connection and making earthing attachment and mending good damages to building works ( PVC casing capping and switch board both on surface ) b) Average run 5 meter.
Distribution wiring in 1.1 KV grade 2 x 22 / 0.30 ( 1.5 sq. mm ) single core stranded ‘ FR ’ PVC insulated and unsheathed single core standard copper wire ( Brand approved by EIC ) in suitable size PVC casing capping ( precision make ) with 1 x 20 / 0.30 ( 1.5 sq mm ) single core stranded ‘FR ’ PVC insulated and unsheathed copper wire for ECC including necessary PVC clips , fittings etc. to 5 A 3 Pin flush type plug socket with piano key type switch ( Anchor make ) fixed on sheet metal fabricated CRC MS switch board with Perspex / Bakelite ( wall matching colour) top cover of 3 mm th. Flushed in wall by housing the board after cutting brick wall including necessary connection making earthing attachment , painting and mending good damages to building works ( PVC casing capping and switch board on both surface ) a) On Board
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unshealhed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduct 'FR' ( Precision make ) including necessary fittings as required a) 2 x36/0.3 (2.5 sqmm) +1 x22/.03(1.5 sq mm) ECC (Domestic Main Switch Loop Connection from Pump Controller to Domestic Main Switch)
Fitting & fixing of Pump Controller (20 HP capacity) of size 950 mm x1000 mm x 450 mm over iron legs (600 mm height) on floor with 150 mm thick Cement Concrete (4:2:1) block and making necessary connection with the electrical cables as per direction of the E.I.C. (excluding cost of Cement Concrete)
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden plank on wall (for lifting & fixing of electrical ewuipments as necessary on the plank)
Supplying, Fixing angular batten holder ( Anchor) on 75 mm dia PVC round block / round bakelite on Wall/ceiling
Supplying ,Fitting and fixing bulk head light fitting (Havells make ) with die cast aluminium housing and frosted glass on wall/ceiling including supplying and fitting 8 Watt CFL/100Watt. GLS lamp complete set.
Finishing the end of following XPLE/PVC armoured cables by crimping method including supply and fitting solderless socket (Dowels make) tapes, anticorrosive paste & joining materials 4 core 16 sqmm cable
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other anciary equipments by means of Megger
M.S. structural works in columns , beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS:808 & SP(6)-1964 connected to one another with bracket, gusets, cleats as per design, direction of Engineer-in-Charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS:816-1969 & IS 1995 using electrodes of approved make and brand conforming to IS:814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as elctrodes, gas and hire charges of all tools and plants and labour required for the work including all incidental charges such as electricuty charges, labour insurance charges etc. Note: M.S. frame for lifting, fixing of Starter/Main Switch/Pump Controlleretc. made with minimum 40 mm X 40 mm x 5 mm M.S. angles and or 25 mm x 5 mm M.S. flats with necessary screwing & holes arrangements of minimum 750 mm 500 mm of size with priming and painting Minimum clearance from wall should be 75 mm. For structural members of specified sections weighing less than 22.5 kg/m
Jointing water proof cable with the leads of the motor including soldering with requisite water proof insulation and proper jointing compound /valcanized rubber tape so that prope water proof insulation is assured.
Drawing submersible cable of motor and pump in 32 mm dia. G.I. conduit 18 SWG upto pump controller making necessary connection and also drawing 8 SWG G.I wire for earthing attachment by f cutting / laying on the floor and mending good damages.
Supplying, fitting & fixing G.I. pipe of TATA make with all neceaary acessories specials, viz. socket bend, tee union, cross elbow, nipple, longscrew, reducing socket, reducing tee, short piece etc, fitted with holder bats clamps, including cutting pipes , making threads, lifting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. ( No seperate payment will be made for accessories, specials) 32 mm dia medium quality.
Fixing only 63 amp. 500 volts T.P.N.I.C. Main switch ( to be supplied Departmentally ) on iron leg on wall as per direction of the EIC
Supplying and fitting and fixing 250 volts 16 amp. D.P. Iron clad Main Switch of approved make with rewire able type fuses on live sides and neutral linked on iron leg on wall as per direction. (Havels make.)
Fixing Ammeter / Voltmeter with necessary screws and other fixing materials including making holes where necessary and making connection.
Supllying and fitting fixing of indicator lamp.
Extra rate allowed over scheduled rate @7.00% on item nos 4.01,4.03,4.04,4.05,4.06,4.07,4.08,4.09,4.12,4.13, 4.14,4.2,4.21,4.22 & 4.23 for Dakshin Dinajpur District i.e Rs 9110.80
Add GST@ 18.00% (On item No 4.01 to 4.24)
Add Cess@ 1.00% (On item No 4.01 to 4.25)
150 mm dia C.I. Sluice Valve with Hand wheel ISI marked, IS 14846
150 mm dia Alfa Alfa type Valve (C type)
150 mm dia 90º G.I bend both ends flanged ISI marked, IS-1239, Galv-4736 (with Priming arrangement)
160 mm FTP
Rubber Insertion 150 mm dia.
i) 200 mm dia (class-I)
ii)140 mm dia (class-I)
iii)160 mm dia (class-II)
i) 200 mm dia ( class-II)
ii) 140 mm dia ( class-II)
ii) 160 mm dia ( class-II)
i) 200 mm dia ( class-II)
ii) 140 mm dia ( class-II)
Supplying of UPVC Flanged Tail Piece ( Class-II) IS:10124 (part-5)/ 1988 with latest amendments upto the destination point inclusive of all charges.160 mm dia flanged tail piece
i) 200 mm dia 90 bend
ii) 140 mm dia 90 bend.
i) 200x160 mm dia UPVC reducer
ii) 140x160 mm dia UPVC reducer
Supplying of end cap (class-III) IS: 10124 (part-4) / 1988 with latest amendments upto the destination point inclusive of all charges.140 mm dia
Supply of solvent cement (havy bodied)
Please Enable Macros to View BoQ information
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tendernotice_2.pdf
PDF • 0.72 MB
BOQ_2406529.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid