Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L1 | Accepted-AOC Accepted being lowest quoted rate | |
| 2 | L2₹11.4 L+₹1.5 L (15.3%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L2 | Rejected-AOC Not accepted since higher quoted rate | |
| 3 | L3₹14.2 L+₹4.3 L (43.2%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L3 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
1 May 2021, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR MAINTENANCE OF COOLING APPLIANCES CEILING FAN EXHAUST FANS AND GEYSERS AT MIL STN GANDHINAGAR
2021_MES_430523_2
GE(A)/GNR/TOKEN/05 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹28,000
Yes
18 Jun 2021
16 Apr 2021
3 May 2021
16 Apr 2021
1 May 2021
18 Apr 2021
16 Apr 2021 - 17 Apr 2021
Amount
Opening (De-assembling) of the ceiling fan, 1200mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of appropriate gauge, slot insulation, heat varnishing, greasing and re-assembling including replacement of split pin and flexible twisted copper cable of 23/0.0076 gauge and testing complete all as specified and directed. Note:- (i) Contractor shall collect the Ceiling fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 2.5 Mfd suitable for 1200 mm sweep ceiling fan.
Supply only ball bearing suitable for 1200mm sweep ceiling fan.
Supply only gun metal bush suitable for 1200mm sweep ceiling fan of appropriate make.
S&F, in repair, PVC canopy set (Upper & Lower) suitable for ceiling fans complete all as specified and directed.
S&F, in repair, MS hanging clamp with rubber bush, bolts, nuts & washer with split pin suitable for 1200 mm sweep ceiling fan complete all as specified and directed.
Taking down of ceiling fan 1200 mm sweep from existing position/hook, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 230 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 250 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
S&F, in repair, PVC body, Fresh air fan, AC single phase 230 volt 50 Hz, 300 mm sweep compete with louvers including making electrical conection complete all as specified and dircted.
Opening (De-assembling) of exhaust fan 300 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Opening (De-assembling) of exhaust fan 380 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Opening (De-assembling) of exhaust fan 450 mm sweep for repair, removing existing burnt winding, rewinding the same with super enameled copper winding wire of approprite gauge, slot insulation heat varnishing, greasing, re-assembling and testing complete all as specified and directed. Note:- (i) Contractor shall collect the exhaust fan for repair from Store Yard of AGE E/M and fix the repaired fan on the location given by Engineer-in-charge. (ii) Whereever required the Ball bearing, bush and capacitor shall be measured and paid separately under respective item of this schedule as "Supply only".
Supply only capacitor of 4.0 Mfd suitable for exhaust fan.
Supply only ball bearing suitable for 300mm sweep exhaust fan complete.
Supply only ball bearing suitable for 380mm sweep exhaust fan complete.
Supply only ball bearing suitable for 450mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 300mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 380mm sweep exhaust fan complete.
Supply only gun metal bush suitable for 450mm sweep exhaust fan complete.
Taking down exhaust fan of size 300/380/450 mm sweep from existing position, cleaning, servicing, greasing, oiling and re-fixing on same position complete all as specified and directed.
Disconnecting carefully water and electric connection from storage type water heater of 25 ltr cap of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing and re-fixing in existing position complete all as specified and directed. Note:- (i) Heating element, thermostat, air release valve, safty valve, indicating lamp and syphone assembly shall be measured and paid under relevant items as "Supply Only". (ii) The rate quoted are deemed to include cost of soldering/brazing work if required at site.
Supply only, heating element of 1.5 KW with circular or triangular base suitable for existing entry of geysers complete all as specified and directed.
Supply only, thermostat 1.5 KW setting upto 85 degree centigrade, ISI marked suitable for existing geysers complete all as specified and directed.
Supply only, thermostat assembly for geyser, tempetrature setting up to 85 degree centigrade, ISI marked complete all as specified and directed.
S&F, in repair, 15mm bore 600mm long, PVC connection, high density suitable for temperature upto 100 degree complete all as specified and directed.
S&F, in repair,semi circular bottom cover plate of 25/50 ltr capacity geyser duly painted of appropriate make complete all as specified and directed.
S&F in repair, wall mounting fan 400mm sweep electrically operated swing type suitable for working on 240 V, Single Phase AC Supply complete all as specified and directed.
S&F in repair, 3 pin plug top of 15/16 Amp, 240 V AC supply ISI marked of Make Bajaj/Anchor or equivalent make as specified in Appx 'C'.
S&F in repair, 3 pin plug top of 5 Amp, 240 V AC supply ISI marked of Make Bajaj/Anchor or equivalent make as specified in Appx 'C'.
S&F, in repair, PVC insulated and PVC sheathed cable 3 core, 2.5 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
S&F, in repair, PVC insulated and PVC sheathed cable 3 core, 6 Sqmm, multistandard copper conductors for water coolers/ refrigerators complete all as specified and directed.
Maintenance & Services of Split AC/Window AC, fixed in position at site, Cleaning of filter, dust with flower motor cleaning of condecing unit and evaporate unit complete all as specified and directed.
Repair and Maintenance of flame proof split AC 1.5 ton with dismentling of assembly cleaning the body with air blower, replacement of electrical contactor set, cleaning of filter for internal unit, replacement insulation for cooling pipe, checking of electrical connection and tightning of the same and testing complete all as specified and directed.
S&F, in repair, fan motor for condencing unit of Split AC of 1.5 TR of the same as of the original equipment manufacturer complete all as specified and directed.
S&F, in repair, PCB for remot operation of internal unit of Split AC of the same as of the original equipment manufacturer complete all as specified and directed.
S&F, in repair, internal blower motor for internal unit electrically operated 230 V AC supply of the same original equipment manufacturer of the Split AC complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 1.5 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing), suitable for working on single phase, 50 HZ AC supply in window/split type A/C of appropriate make including making necessary refrigerent pipe connection, electric connection, checking of leakage and testing complete all as specified and directed for 2 TR Capacity, complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in water cooler of 40/80 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/8 HP (165 to 210 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing ) suitable for working on single phase 50 Hz AC supply in refrigerator 1/6 HP (265 to 310 Ltrs) capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
S&F, in repair, sealed unit compressor (replaced with original company new compressor of same make as per existing) suitable for working on single phase 50 Hz AC supply in deep freezer 310/320 Ltrs capacity including making connection and brazing of necessary refrigerent pipe, electric connections and testing for leakproof complete all as specified and directed.
M&L, in repair, starting relay of window/Split type A/C, 1.5 to 2 TR capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, starting relay of water coolers 40/80 Ltr capacity including making necessary electric connections complete all as specified and directed.
M&L, in repair, starting relay of Refrigerator 1/8 to 1/6 HP capacity including making necessary electric connections complete all as specified and directed.
S&F, in repair, overload protector of A/C 1.5 to 2 TR complete all as specified and directed.
S&F, in repair, overload protector of Water coolers up to 120 Ltr complete all as specified and directed.
S&F, in repair, overload protector of Refrigerator and Deep freezer 165 Ltr to 310 Ltr complete all as specified and directed.
S&F, in repair, Thermostate suitable for A/C 1.5 to 2 TR complete all as specified and directed.
S&F, in repair, Thermostate suitable for Water coolers up to 120 Ltrs complete all as specified and directed.
S&F, in repair, Thermostate suitable for Refrigerators & deep freezer up to 310 Ltrs complete all as specified and directed.
S&F,in repair, Starting capacitor 230 Volt, 100-150MFD suitable for AC's complete all as specified and directed.
S&F,in repair, Starting capacitor 230 Volt, 80-100MFD suitable for AC's complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 6.3 MFD complete all as specified and directed.
S&F, in repair, Running capacitor, 230 Volts, SP, 36/45 MFD complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for window/split type A/C of capacity 1.5 & 2 TR and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Water Cooler of capacity 40/80 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
M&L for refrigerent charging with R-22/R-134 for Deep Freezer of capacity 165 Ltr to 320 Ltr and making necessary copper tubing connection for refrigerent line, soldering, brassing of leakage point complete all as specified and directed.
S&F, in repairs, water lift submerssible pump (ISI Marked) suitable to operate on 230V AC supply of desert cooler and connecting electically, complete all as specified and directed.
S&F, in repair, fan motor (ISI Marked), 1/10 HP, 230 volt single phase of existing desert cooler with fixing clamps, complete all as specified and directed
S&F, in repair, wood wool pads, superior quality, size 60x45 cm (approximate), complete all as specified and directed
S&F, in repair, Candles of existing water purifier at the inlet of the water cooler of any capacity complete all as specified and directed.
Attending daily complaints of cooling appliances of ACs water cooler, Regrigerator, Deepfreezer, Desert Cooler etc. like cooling problem, burned wire, relays, charging of gas and found out leakage including taking down unserviceable parts complete all s specified and directed. Note : If Loged complaint are not done by contractor every day recovery should be made double of quoted rate. (2) Any spare parts required will be measured and paid separately.
Cutting opening in cement concrete walls (any description) for door, window and other openings (with or without reveals) or enlarging existing openings complete all as specified and directed.
S&F, in repair, 5/8, 3/8 pair insulated copper pipe suitable for R410a, R22, R407c, etc regrigerants. Including PVC D clamp complete all as specified and directed.
M&L, in replacement to voltage stabilizer of capacity 5 KVA single phase input 180 to 250 Volts, out put voltage stabilizer 230 V including replacment of worn out/short circuit pointed circuit board, voltmeter, 15/5 Amp socket, relay etc and testing on completion complete all as specified and directed.
M&L, in replacement to voltage stabilizer of capacity 4 KVA single phase input 180 to 250 Volts, out put voltage stabilizer 230 V including replacment of worn out/short circuit pointed circuit board, voltmeter, 15/5 Amp socket, relay etc and testing on completion complete all as specified and directed.
S&F, in replacement, PVC insulated and PVC Sheathed cable copper conductor 3 core 23/0.0076 cross sectional area (superior quality) complete all as specified and directed.
S&F, in replacement PVC pipe 15mm dia heavy duty for Desert Cooler Pump complete all as specified and directed.
ALBA AC AND REF SERVICES
ARTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .