Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹87.2 LAccepted-AOC SCO 117 118 FF CABIN NO 104 SECTOR 17B CHANDIGARH | ₹87.2 L | L-1 | Accepted-AOC AOC |
| 2 | L-2₹93.3 L+₹6.1 L (7.02%)Rejected-Finance 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 1 PH 011 43573493 9899713006 | ₹93.3 L+₹6.1 L (7.02%) | L-2 | Rejected-Finance Highest |
| 3 | L-3₹88.5 L+₹1.3 L (1.53%)Rejected-Finance B 1703 MODERN INDUSTRIAL ESTATE BAHADURGARH HARYANA 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | ₹88.5 L+₹1.3 L (1.53%) | L-3 | Rejected-Finance Highest |
| 4 | L-4₹89.6 L+₹2.4 L (2.77%)Rejected-Finance | ₹89.6 L+₹2.4 L (2.77%) | L-4 | Rejected-Finance Highest |
| 5 | L-5₹1.1 Cr+₹24.0 L (27.6%)Rejected-Finance | ₹1.1 Cr+₹24.0 L (27.6%) | L-5 | Rejected-Finance Highest |
Tender Value
₹94.9 L
EMD Value
₹1.9 L
Closing Date
9 Sept 2019, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division PWD B and R Br., Ambala Cantt
Upgradation of Auditorium Bldg. in Govt. College Sec-14 Panchkula (Pdg. Central AC system - Air Cooled Chiller system).
2019_HRY_98110_1
PWD/Elect-KNL/Elect-AMB/16341
Open Tender
Construction Works
Works
90 days
Ambala
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
Executive Engineer, Elect. Division PWD B and R Br
₹1.9 L
20 Dec 2021
27 Aug 2019
11 Sept 2019
27 Aug 2019
9 Sept 2019
27 Aug 2019
Amount
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 185 Sq. mm 3.5 Core Cable . 31.26
50 Sq. mm 3.5 Core Cable . 31.27
Earthing Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as equired. 31.22
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as equired. 31.22
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. 31.22
Pdg. and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required with all labour and material. 31.22
Pdg. and fixing 25 mm x 5 mm G.I. Strip on surface or in recess for connections etc. as required with all labour and material. 31.22
Supply & erection of factory manufactureed cable tray cover made of 16g GI Sheet complete with Fastoner Nuts bots and in position including all petty material required to complete the Job in all respect upto the Entire statisfaction of Engineer in Charge of the work Suitable for 50 x 150 mm 31.82
Suitable for 50 x 300 mm 31.82
Supply, Installation, testing and commissioning of Air cooled DX Chiller of 68 TR (MIN NOMINAL CAPACITY) and unit shall consist with hermatic sealed scroll type compressors suitable for R-407c. air cooled condenser with Hydrophillic coating of aluminium fins (minimum 0.12 mm thickness) and Copper tubes, Insulated Shell and tube DX Evaporator, Micro Processor Controller as supplied by OEM as part of Chiller Package. The Unit mounted starter panel with double door construction shall be single Power point type complete with IP 55 Degree protection complete with Under/Over load, voltage, phase loss and phase reversal protection, Single Phase Preventers, communication card which can accept 4-20 mA or 2-10 V dc analog signal. The unit shall be complete with Discharge Service valves (applicable in case of Tandem Circuit only) to isolate refrigeration circuits , vibration Isolators to isolate chiller from building structure, pressure gauges Thermostatic expansion valves, solenoid valves, anti-freeze thermostats, refrigerant piping with Insulation for suction line, accessories of Safety valve, angle valve, liquid line indicator, water flow switch, Relief valve and including MS stand to install the chiller units fabricated out of suitable size of structural steel sections etc. all as per OEM. All accessories housed in a single chasis design. The noise level measured at a distance of 3 Mtr from the machine at anywhere in the plant room shall not exeed 80 dBA +-5% The chilled water type AC plant will be suitable for operation on 3 phase AC 50 Hz supply . The said Chiller package shall have stepped control based on number of compressors. The chiller shall be as per specifications. The water chilling machine shall meet the following design parameters Chilled Water leaving Temp. : 7ºC Chilled Water entering Temp. : 12ºC Evaporator fouling factor :0.000088 MKS Ambient Temperature : 43º C IKW/TR shall not be more than 1.55 at 100% Load COP at 100% Load: 2.9 at AHRI Cooling capacity at above conditions not less than 60 TR (2 Nos Working) Including Cost of Foundation for Chiller as per drawing of manufacturer complete in all respect.
Floor Mounted Air Handling Units Supply Installation Testing Commissioning of Next Generation of Floor Mounted AHU Outdoor weather Proof Type with Thermal Break Profile, cabinet having frame work of extruded hollow aluminim sections, with 48 + 2mm thick Thermo-acoustic panel. Thermo-acoustic panel shall be comprising of 23+ 2mm thick thermal insulation of 40 Kg/Cu.M density PU foam injected between 0.8 mm pre-coated GI outer sheet & 0.8mm plain GI intermediate sheet, followed by tissue paper laminated glass wool/Nitril insulation of 25+2 mm thickness having 70-80 Kg/Cu.M density sandwiched between indermediate sheet and inner skin of 0.8mm perforated GI sheet. The unit shall be provided with stainless steel drain pan made out of 18G SS 304 sheet duly insulated with 13mm closed cell nitrile rubber insulation,Mixing Box ,Fresh Air Dampers.The unit shall be equiped with TEFC drive motor of Efficiency Class IE 3 fan with blower suitable for operation on 415 volts + 10%, 50 Hz, AC supply, 6 Row cooling coil of 0.13 mm Aluminum fins and Copper tube of 1/2" or suitable copper tube not less than 0.5 mm thickness or suitable for chilled water Piping,Light and pre-filter of EU-04 grade. as per following specifications:- CFM TYPE SP CC /TR 12000 FM 60 6 RD /32.0
Ceiling Suspended Air Handling Units SITC of Double skin Air Handling Units complete with filter section with pre filters, Drive arrangements, motor, CHW cooling coils, fan section with Imported Blower as per following specifications:- Hardware for hanging of AHU with GI thread rods, check nuts/washers CFM TYPE SP CC /TR 4000 CS 40 6 RD /12.0
6000 CS 30 4 RD /15.0 Note: (1) Maximum Fan outlet velocity will be within 10m/s. (2) The maximum face velocity across all types of filters & coil has been considered as 500 FPM. (3) Sound levels will be within normal acceptable limits as achieved with good HVAC engineering practice. (4) Ceiling suspended units shall be provided with side door/bottom door- for inspection. (5) Filter section with 25 mm thick box type pre-filter. (6) Coil section with multi-rows deep chilled water type cooling coil. (7) Fan section with imported DIDW centrifugal forward curved fan, motor, V-belt & drive set. (8) Condesate drain tray shall be of SS-403 duly sandwiched with PUF insulation & drain connections. (9) AHU Panels: Outer Skin -- 0.6 mm precoated GI & Inner Skin -- 0.6 mm plain GI
Fan Coil Units SITC of Chilled FCUs double skin, having CHW cooling coil 4 row deep,pre filters complete with Ball valve assy, 3-way control valves, Thermostat, wiring,fittings, Aux. Drain tray, pipe insulation, hanging arrangements etc.complete in all respects of cap:- 3.0 TR ( 1200 CFM)
HOT WATER GENERATOR SITC of Electric hot water generators of following capacities vertical tubular shell type fabricated from MS sheet 8mm Shell 10mm Dish ends, Top open able with sufficient number of Nut Bolts and joints shall be welded and shall be tested for working pressure of 21 kg/cm² complete with sheathed tubular electric resistance type heater elements , control panel with contactor, internal, wiring, safety controls, thermostat, IN and OUT connections, drain connection at the bottom, water flow switch and interlocking with control panel, Step Controller, Pressure Gauges with Ball Valves, Pressure relief Valve, Low Level cutout and Auto vent. It shall be insulated with 50 mm thick fiber insulation and covered with 1 mm thick Aluminium cladding. 75 KW (Minimum 4 steps)
Chilled/HOT Water Pumps Supplying, installing, testing and commissioning of PN 16 rated Long/split coupled Vertical Inline Pumps duly factory mounted with electric motor. Pumps shall be capable of delivering 144 GPM (Actual) of water against 30 mtr head. Complete pumpset should be tested at manufacturing facility & test certificates shalll be provided by the manufacturer. Pumps should be adhere to following performance characteristics:- a)1 No. - Vertical Inline Split Coupled type pump with CI casing, Bronze impeller, SS shaft, outside type balanced mechanical seal. Suction guide to be supplied by pump manufacturer for unit b)responsibility. c)1 No.- Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation,IP -55 Protection IE-3,1450/2950 RPM synchronous speed, operating on 415 volts ± 10%, 3 phase, 50 Hz A.C. supply. Pump as above (2 working + 1stand by) Note: The civil foundations reqd shall be made by the tenderer.
CHILLED WATER PIPING Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. For 125 MM Pipe DIA with 75 mm Thick Insulation
For 100 MM Pipe DIA with 50 mm Thick Insulation
For 80 MM Pipe DIA with 50 mm Thick Insulation
For 65 MM Pipe DIA with 50 mm Thick Insulation
For 50 MM Pipe DIA with 50 mm Thick Insulation
For 40 MM Pipe DIA with 50 mm Thick Insulation
For 32 MM Pipe DIA with 50 mm Thick Insulation
For 25 MM Pipe DIA with 50 mm Thick Insulation
SITC of INSULATED VALVES/CONTROLS - PN-16 SITC Wafer Type C.I. Butterfly Valves(Manual) with Nylon Coated,Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/ hot water circulation as specified,SS-stem with Hand Lever Fittings like Flanges, Nuts & bolts, etc. 125 MM DIA
100 MM DIA
80 MM DIA
65 MM DIA
50 MM DIA
Supplying, fixing, testing and commissioning of duly insulated Balancing Valves with rating PN16 80 MM DIA
65 MM DIA
50 MM DIA
SITC Y - Strainer-with actual bore size & double strainer size suitable for PN-16 80 MM DIA
65 MM DIA
50 MM DIA
SITC Dual Plate Type Wafer Swing Check Valves Cast Iron to IS 210 Gr. FG 260 with Fittings like Flanges, Gaskets, Nuts &bolts, etc. 80 MM-DIA
SITC of Ball valves with & without strainers along with all required fittings etc.of sizes: 25 mm without strainer
25 mm with strainer
40 mm without strainer
40 mm with strainer
SITC Water Flow Switches
SITC Auto Air Purging Valve 3/8"
SITC Pressure Gauge 4" Dial (0 To 6 Kg/CM2)
SITC 6" StemType Thermometers (0 To +50OC)
SITC of 3 - Way Mixing Valves with Actuator, Linkage, RH +Temperature Controller, Sensors, Control wires, Thermostat and Necessary Fittings etc. as per Following Sizes 25 mm dia
40 mm dia
50 mm dia
65 mm dia
Expansion Tank , SITC of MS Expansion tank of size 1.0 m x 1.0 m x 1.0 m height made of 5 mm thick MS sheet complete with vent and drain connection, quick fill with float valve and control valve etc. as required. Litres duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete in all respect
Ducting SITC of Factory/SITE fabricated GSS Ducting complete with hanging arrangement of fasteners, GI threaded rods etc.,However Bends,Vanes,Collor can be can be made at site as per requirment 24 G (0.63 MM)
Nitrile Insulation (Inside Conditions) SITC of 13 mm thick Microcellular Closed Cell Elastomeric Nitrile rubber Insulation (Class O/Fire retardant) with factory faced Reinforeced Aluminium foil with thermal conductivity 0.037 W/m Deg.K pasted on the outer/Inner surface of duct with suitable adhesive complete in all respects with Nitrile tapes.
Nitrile Insulation (Outside/Open Conditions) SITC of 19 mm thick Microcellular Closed Cell Elastomeric Nitrile rubber Insulation (Class O/Fire retardant) with factory faced Reinforeced Aluminium foil with thermal conductivity 0.037 W/m Deg.K pasted on the outer/Inner surface of duct with suitable adhesive complete in all respects with Nitrile tapes.
Acoustic Lining SITC of Acoustic lining of the supply duct with 10 mm thick Accosound Nitrile board with suitable adhesive to be pasted inside of the Plenum duct complete in all respects 10 mm thickness accosound Board
Grill/Diffussers SITC of Aluminium extruded powder coated Grills for supply & return air w/o vcd
SITC of Aluminium powder coated Diffuser for supply & return air w/o vcd
Dampers Supply, installation, testing & commissioning of GI Collar dampers
Supply, installation, testing & commissioning of CBRI approved Fire duct Dampers for at least 90 min fire rating as per UL555:1955 Specifications without Sleeve
Supply, installation, testing & commissioning of Spring Return Actuator and Control Panel Complete with Heat Sensors , Complete Control wiring and Limit switch,4NM/7NM/9NM,(24VAC/220VAC)
Fresh Air Louvers SITC of Extruded aluminium exhaust air / fresh air louvres with frame, bird screen, pre-filter with frame, mounting arrangement etc. as per specifications and drawing. Fresh Air / Exhaust air Louvers
Condensate Drain Piping: Providing UPVC pipes of various sizes for condensed water drainage from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as approved by architect/consultant/Client All necessary civil works like cutting & chasing of walls/floor/ glass etc. and make them good thereof 40 MM DIA with 6 mm Nitrile Insulation
32 MM DIA with 6 mm Nitrile Insulation
25 MM DIA with 6 mm Nitrile Insulation
Power & Control Works Supplying and laying of following 1100 volt grade PVC insulated sheathed copper conductor armoured cables in trenches, on walls clamped to wall with suitable clamps, saddles, and fixing bolts, or laying in ground including cost of digging brick and sand protection, and including jointing / connecting / terminating, testing and commissioning : 4C x 16Sq. mm Copper (armoured) Conductor
4C x 10Sq. mm Copper (armoured) Conductor
4C x 4.0Sq. mm Copper (armoured) Conductor
Control Cabling Providing & fixing of electrical supply Flexible Cabling of 4 core x 2.5 sq. mm copper in suitable conduits between IDU & Room DB.
Providing & fixing control cum transmission wiring/ Control Cabling of 2 core x 1.5sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller.
Providing & fixing control cum transmission wiring/ Control Cabling of 4 core x 1.5sq. mm copper in suitable conduits for Actuator/Motor , Fire Dampers Control Dampers
Main Electrical Panel (CPRI Approved) Electrical Main Panel Powder Coated Made out of Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces as per following specifications complete in all respect INCOMING SUPPLY : MCCB 500-630 Amps 50 KA 4 Pole Micro processor based Adjustable type with Rotary Mechanism & all Protections along with spreader links,etc : 1 No. Multi Fuction VAF/VIF Meter (96mmX96mm Size) ,Indication Lamps LED Type RYB, Control MCB SP for Control (3 Nos),CT's 300/5 (3 Nos) etc. OUTGOING FEEDERS :MCCB 250 AMPs 36KA 3 Pole with Rotary Mechnism & all Protections along with spreader links,ect.(HOT WATER GENERATOR-1 NO. working with electrical interlocking provisioning MCCB 250 Amps 36 KA 3 Pole with Rotary Mechanism & all protections alongwith Spreader links, etc ( Chillers-2 no. working) with electrical interlocking provisioning Star Delta Starter from 10 to 12 HP or suitable as per requirment with Digital Amper meter & ASS inclusive of MPCB Contactors, O/L RELAY & SPP for Chilled Water Pumps - 3 Nos (2W +1S) MCCB TPN Upto 10-40 Amps (5Working + 2 Spares =7 Nos) for AHUs BUS BAR : Aluminium Bus Bar 800 A TPN Electrolite grade E91 having Suitable size Cross Section for Phase,Neutral& Current Carrying Capacity 0.8 A/Sqmm Hardware ( PVC Cahnnels/MCB Channels/Fibre- Glass Gaskets/Sleevs/nuts/bolt/washers/cooling fans etc Including complete wiring,thimbles etc. Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.
AHU Panel SITC of AHU panels duly powder coated wall mounted Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make CRCA Sheet of 1.6 mm thick consisting of Upto incomer as MPCB suitable as per AHU ON/OFF/TRIP indication light LED type, DIGITAL Ammeter with ASS; CT's 30/5; contactors up to32A or Suitable (with 2 NO+ 2NC); Start/Stop push buttons with auto & Manual control switch, Single Phase Preventer, MCB DP upto 10 Amps C Curve ,Over load Relay 16-25A or Equivalent Suitable , power & control terminals; neutral link and internal wiring & connections for AHU motors upto 5 HP or Suitable
Ventilation for Smoke Extraction Axial Smokespill Fans SITC of SINGLE Speed AXIAL Flow FAN complete with totally enclosed fan cooled motor direct driven, and fan shaft, motor mount, bird screen ,Isolators as per the specifications. Fan motor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply. Fans for high temperature ( except for fresh air) ratings shall be capable to work at 250 Deg C for at least 2 hours. The Axial fans shall be supplied with power panel. Fan capacity shall be as follows: Auditirium Smoke Exhaust High temperature fans suitable for 15000 CFM with 25mm static
High temperature fans suitable for 9000 CFM with 25mm static
CO sensors
Civil Work Civil Work for making Holes, Chiesling, Core Cutting of walls/ RCC Slab etc. and make them good thereof
Electrical Control Panel for Ventilation system Electrical Main Panel weather Proof outdoor Type Powder Coated Made out of TATA/SAIL/ESSAR/JINDAL/Reputed make sheet having thickness 2.0 mm for load bearing surfaces & 1.6 mm Non bearing surfaces as per following specifications complete in all respect Electrical PLC Based Panel for Ventilation with Main Incomer of suitable capacity as MCCB with Breaking capacity of mininum 36KA with spreader Links & ROM, MPCB feeders for DOL Starter upto 10HP and above 10 HP Star Delta starter with combination as per Type 2 cordination chart of contactor/contactors with O/L relay with on off push button, on/off/trip indicators, potential free contacts for Fire Alarm to operate on remote signal from smoke control panel (The panel shall have convertor incase of digital signal from the fire panel/BMS) PLC logic controller with necessary internal control wiring,Bus Bar etc. (As per required by OEM of Ventilation Fans) Hardware ( PVC Cahnnels/MCB Channels/Fibre- Glass Gaskets/Sleevs/nuts/bolt/washers/cooling fans etc Including complete wiring,thimbles etc. Unloading at site, placement of Panel on the foundation, co-ordination during execution, rendering necessary guidance for execution, supervision, testing, commissioning and startup of above mentioned Panel.
Underdeck Insulation Providing & Fixing Underdeck Insulation with 50 mm thick TF Quality EPS of Density 20 Kg/M3 fixed to slab with good quality Black CPRX Compound. 28Gwirenet shall be tightened arround insulation so as avoid any kind of sagging, Ends of net shall be overlapping at least 25mm. Overlaps shall be screwed with galvanized screws to avoid rusting
Schedule No. 2 for CMC 1st Year - (Operation cost only) @ 2% on Original work done amount
2nd Year - Comprehensive maintenance & Operation @ 4.5% on Original work done amount
3rd Year - Comprehensive maintenance & Operation (@ 5% on Original work done amount)
4th Year - Comprehensive maintenance & Operation (@ 5.50% on Original work done amount)
5th Year - Comprehensive maintenance (@ 6% on Original work done amount e & Operation)
snowmex engineers ltd
Hemcool Engineers
modern cooling solution
Accurate Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .