Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.1 LAccepted-AOC CB 4190 SREE CHITHRA NAGAR PANGODE THIRUMALA P O THIRUVANANTHAPURAM 695 006 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695006 | 1 | Accepted-AOC L1 | |
| 2 | 2₹37.4 L+₹1.3 L (3.57%)Rejected-AOC | 2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
22 Oct 2022, 6:00 pmClosed
Executive Engineer
Office of the Executive Engineer,Electrical Division TVM
DEPOSIT-Daily operation MSB-Daily operation of Electrical installation installed in Multi Specialty Block of Medical college Hospital Thiruvananthapuram for the period from 1-11-2022 to 31-10-2023.-General Electrical Work
2022_PWD_515592_1
EDT_ET_25_2022_23
Open Tender
Electrical Works
Item Rate
365 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
17 Nov 2022
12 Oct 2022
25 Oct 2022
12 Oct 2022
22 Oct 2022
12 Oct 2022
Amount
Daily operation
OD1225/2022-2023: Supply and providing the following duty staff, having qualifications as mentioned at site for the operation of the existing Substation consisting of 2 Nos. 630 KVA Transformers, 1 No. 500 KVA DG set, HT /LT control Panels and other Electrical installation provided in the Multi-speciality Block of Medical college Thiruvananthapuram under the control of Assistant Engineer (Electrical) PWD ,Medical College Section and operating the system as per his direction. The Sub-Station including DG set should be operated daily with staffs arranged in 3 shifts. The minimum staff requirement in each shift is as follows: 1)Diploma holder in Electrical Engineering certificate to be recognized by Board of Technical Examination Kerala with minimum of 2 years experience. – 1 No. 2)ITI/ITC certificate holder in Electrical/Wireman trade to be recognized by NCVT with minimum of 2 years experience. – 2 Nos. The electrical installation shall be operated as detailed in the mode of operation attached separately. The certificates of the operating staff should be produced before the Executive Engineer at time of agreement.
OD4852/2022-2023:Supply of following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD4857/2022-2023:Supply OF following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
OD4858/2022-2023:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD4859/2022-2023:Supplying 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD4860/2022-2023:Supplying following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD4863/2022-2023:Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
OD4865/2022-2023:25 A3 pin shuttered socket modular
OD4866/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
OD4867/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
OD4868/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
OD4869/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
OD4870/2022-2023:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
OD4871/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
OD4872/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
OD4873/2022-2023:Supply of 300/305 mm sweep Light Duty Exhaust fan in metal frame
OD4874/2022-2023:Step fan regulator - socket size
OD4875/2022-2023:Supplyingof following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
OD4876/2022-2023:Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
OD4877/2022-2023:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
OD4878/2022-2023:Supply of 25 A 3 pin plug top with indicator
OD5090/2022-2023:Supply 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal coupler
OD5091/2022-2023:Supply of 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
OD5092/2022-2023:Supply of 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover
OD5094/2022-2023:Supply 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
OD5095/2022-2023:Supply 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
OD5096/2022-2023:Supply 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
OD5097/2022-2023:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
OD5099/2022-2023:Supply of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
OD5100/2022-2023:Supply 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.4 to 5 module mounting box
OD5101/2022-2023:Supply OF 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
OD5106/2022-2023:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
OD5107/2022-2023:Supply following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
OD6187/2022-2023:Supply following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel,making connection etc.as required 200 Amp,16KA TPMCCB
OD6399/2022-2023:Supply 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) using 4 nos steel chain(16swg)of length not exceeding 30cm properly hooked to steel hooks anchored to to the ceiling and giving connection with required length of 16/0.20mm 3core copper conductor flex wire conforming to relevent ISS or extending the orginal wiring and giving connection etc.as required
OD6188/2022-2023:Supply of following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel. making connection etc.as required 100Amp,30KA 4 pole
OD6193/2022-2023:Supply of 1 no PVC insulatedarmoured aluminium power cable 1.1KV grade of the following size using clamps noted along with cables,spacing of clamps not exceeding 60cms,making good the damages,colour washing etc.as required 3.5 core 25sq mm with factory made clamp
OD6256/2022-2023:Supply of recess mounting LED down light fitting of the following type 1800 lumen round/ square(1X1) recessed fitting made of diecast aluminium, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea
OD6320/2022-2023:Supplying following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD6321/2022-2023:Supplying following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD6322/2022-2023:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD6336/2022-2023:Supplying of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
OD6337/2022-2023:Supply OF following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
D SURESH
Bidder Name
D SURESH
R.Radhakrishnan Nair
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_739350.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .