| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.6 LAdmitted-Fee/PreQual/Technical/Finance | -16.00% | ₹2.6 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹2.8 L+₹13,479.08 (5.12%)Admitted-Fee/PreQual/Technical/Finance | -11.70% | ₹2.8 L+₹13,479.08 (5.12%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹2.8 L+₹14,921.02 (5.67%)Admitted-Fee/PreQual/Technical/Finance | -11.24% | ₹2.8 L+₹14,921.02 (5.67%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹3.1 L
EMD Value
₹7,837
Closing Date
19 Aug 2026, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
DEPOSIT-Govt Polytechnic College, Neyyattinkara, Tvpm- Renovation to EI in Basic Electronics/ Electronics Circuit Lab in connection with civil renovation works.-Providing EI-General Electrical Work
2026_PWD_865057_1
ESDT/ET-88/2026-27
Open Tender
Electrical Works
Percentage
90 days
PWD Electrical Sub Division Tvpm
please refer tender documents
6 documents required · 6 mandatory
₹695
₹7,837
22 Aug 2026
11 Aug 2026
21 Aug 2026
11 Aug 2026
19 Aug 2026
11 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing EI | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,726.78 | - |
| 1.002 | 1.54.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C | - | point | 1,288.01 | - |
| 1.003 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). | - | each | 561.53 | - |
| 1.004 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top | - | each | 125.15 | - |
| 1.005 | OD120043/2026-2027:Supply and Providing 1.5 sqmm (30/.25 mm)Three core FR Industrial Flexible Cable PVC insulated, PVC sheathes copper cable suitable for 1100V , 230V, 50Hz, 17 A rating etc with conformig IS 694:2010 etc as required.(Poly cab or its equivalent make) | - | metre | 225.56 | - |
| 1.006 | OD119961/2026-2027:Supplying and fixing Teak wood box of 300 mm X 200 mm X 50 mm deep sizes on surface with suitable size of phenolic laminated sheet cover in front and including fixing 6 Nos piano type6A socket outlet , 6 Nos 6A piano type switch and 1 Nos piano type indicator etc fixed on the board as required. | - | each | 1,811.76 | - |
| 1.007 | 1.40:Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required. | - | metre | 47.47 | - |
| 1.008 | OD105379/2026-2027:Supply Conveyance, installation, testing and commissioning of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) suspended from ceiling using 2 nos steel chain (16 SWG or nearest) of length not exceeding 100 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (for fitting in false ceiling) | - | each | 5,242.1 | - |
| 1.009 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | - | each | 2,250.4 | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
specialconditionsmodified.pdf
Additional Documents • 0.15 MB
BOQ_1463990.xls
BOQ • 0.36 MB
viewsbd.pdf
Additional Documents • 1.63 MB
mom1MAIN.pdf
Additional Documents • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .