Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L-1 | Accepted-AOC L-1 Bidder |
| 2 | L-2₹1.4 Cr+₹10.0 L (7.61%)Rejected-AOC 1286 3 SHASHRI NAGAR MEERUT | MEERUT | ₹1.4 Cr+₹10.0 L (7.61%) | L-2 | Rejected-AOC L-2 bidder |
| 3 | L-3₹1.7 Cr+₹40.2 L (30.5%)Rejected-AOC 701 702 7TH FLOOR TOWER A SIGNATURE TOWER SOUTH CITY 1 SEC 30 GURUGRAM HARYANA 122001 | GURUGRAM | GURUGRAM | HARYANA | 122001 | ₹1.7 Cr+₹40.2 L (30.5%) | L-3 | Rejected-AOC L-3 Bidder |
| 4 | Rejected-Technical NIL | - | - | Rejected-Technical Bid Document Not found in Orde |
Tender Value
₹1.6 Cr
EMD Value
₹3.9 L
Closing Date
3 Jun 2021, 11:30 amClosed
Chief Engineer Op South
Office of Chief Engineer Operation South HPSEBl Shimla 171004
Replacement of 22kV RMU with VCBs (Indoor Type) at 22kV Control Point Nirth including Civil Works on Turn key basis complete in all respect in Electrical Sub Division Taklech under Electrical Division HPSEBL Rampur Bsr.
2021_HPSEB_46680_1
CEO/MnC/T. No.01/ R/R of 22kV RMU with VCBs (Nirth
Open Tender
Supply and Erection
Item Rate
240 days
Nirth Rampur Bsr
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,900
Sr Accounts Officer FA HPSEBL
₹3.9 L
30 Sept 2021
22 Apr 2021
4 Jun 2021
22 Apr 2021
3 Jun 2021
22 Apr 2021
22 Apr 2021 - 28 Apr 2021
Amount
Providing Design, Supply, Erection Testing & Commisioning of 22 kV indoor type Control, and Relay (CR) Panel with VCBs, 22kV, 1250A 25 kA) comprising of 2 Nos. (CT Ratio 400-200/1-1-1 A, alongwith PT 22kV/110V-3 Phase Indoor {Numeric Relay IEC 61850}
Providing Design, Supply, Erection Testing & Commisioning of 22 kV indoor type Control, and Relay (CR) Panel with VCBs, 22kV, 1250 A, 25kA comprising of 6 Nos. VCBs (CT Ratio 200-100/1-1-1 A) for out going feeders (6 Panels set) {Numeric Relay IEC 61850
Providing Design, earthing of Control Room and yard with mat.
Erection of MS Flat of 50x6mm size for Ground Mat including 5% wastage and weight 2.4 KG/mtr. 2(10x7+9x7)x1.05=139.65 mtr. or 335.16 Kg. all joints to be coated with black bitumen paint and then covered with bitumen tape as per specifications), complete and including pipe electrode earthing at 8 Nos. locations with GI pipe and 50 mm dia with hole of 16 mm dia at 150 mm from centre to centre for 2 mtr distance from bottom (MS plates 150x150x6 mm for two connections and 20 mm MS round 3 mtr. long electrode at 12 No. locations including applying red oxide primer paint on all fabricated steel work and apllying red oxide primer complete in all respect.
Earthing of 22 kV yard and super structure , VCB panels, DC distribution board AC Distribution Board and other allied equipment such as LAs etc. with MS flat 20x6 mm weight 1.2 Kg/mtr.(40x1.2-48 kg) complete including welding of risers etc and also applying red oxide primer on all fabricated steel work complete in all respect.
Providing Design, Supply, Erection Testing & Commisioning of 22KV Isolator (630 A) with earth blade alongwith supporting structure.
Providing Design, Supply, Erection Testing & Commisioning of 22kV (10 kA) Station Class outdoor type lighting arrestor.
Providing Design, Supply, Erection Testing & Commisioning of 22kV 3-Core XLPE 185 mm 2 HT Cable (22kV 3-Core XLPE 185 mm 2 shall be provided by HPSEBL)
Providing Design, Supply, Erection Testing & Commisioning of 22KV outdoor type termination kit for XLPE 185 mm2 HT cable (SINGLE CORE)
Providing Design, Supply, Erection Testing & Commisioning of 22KV indoor type termination kit for XLPE 185 mm2 HT cable (SINGLE CORE)
Providing Design, Supply, Erection Testing & Commisioning of 415 Volts LT Cables, DC & Control Cables.
2x 2.5 mm2 screened copper control cables
4x 2.5 mm2 screened copper control cables
3.5 core 95 mm2 aluminium cable suitable for 415 V
Providing Design, Supply, Erection Testing & Commisioning of Yard Lighting
8 Mtr. 100 mm dia GI pipe poles with muff for yard lighting
72 watt LED Street light along with fitting and accessories complete in all respect. Havells
Underground cable 16 mm 2 for connecting LED lamp
PVC cable 6 mm 2 for connecting LED lamp
Junction Box
Lighting Emergency (3 No Led Bulbs with Holder and Wire)
Providing Design, Supply, Erection Testing & Commisioning of 30 Volts 100 AH Lead Acid Battery bank , along with Dual float cum boost battery charger and DC distribution board complete in all respect.
Providing Design, Supply, Erection Testing & Commisioning of 415 Volts AC distribution switchgear alongwith 3-phase DLMS energy meter alongwith one incomer MCCB 100 Amps (1 spare also, total 2 Nos) and 6 Nos outgoing feeders with 3 Nos 32 Amp ( 1 spare also, total 4 Nos) MCCB & 3 Nos 16 AMP MCCB(1 spare also, total 4 Nos), complete in all respect as per technical specifications.
Providing Design, Supply, Erection Testing & Commisioning Fire Extinguisher ABC Type.
Providing fire Extenguisher ABC type Dry compund Type ready for use (6 Kg capacity) as per relevant standard specifications and of standard make.
Providing fire Extenguisher ABC type Dry compund Type ready for use (9 Kg capacity) as per relevant standard specifications and of standard make.
4 Sand Buckets along with stand.
CIVIL WORKS
Demolition of brick work above ground level up to floor two level including stacking of serviceable material and disposal of unserviceable material with all leads and lift
Demolition above G.L. upto floor two level including disposal of unserviceable materials within 20 metres lead and including cutting the necessary reinforcement and separating out from in RCC work
Dismantling doors, windows and clerestory windows, ventilators etc. (wood or steel) shutters including chowkhats, architraves, hold fasts and other attachements etc. complete and stacking them within 20 metres lead.
Excavation in foundations trenches etc. in earth work, lift upto 1.50 meters stacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacked soil 15 cm layers. When required in the plinths sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in a lead of 20 meters. 50% PW & 50% JW
Providing and laying cement concrete 1:6:12 (1 cement : 6 Sand :12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of centering and shuttering.
Random rubble masonry/polygonal rubble masonry (uncoursed /brought to courses) with hard stone of approved quality in foundation and plinth including leveling up with cement concrete 1:6:12(1 cement:6 sand:12 graded stone aggregate 20 mm nominal size) in cement mortar 1:6(1cement:6 Sand) in breast walls and retaining walls
Half brick masonry work in common brunt clay building bricks in cement mortar 1:4 ( 1 cement : 4 sand) first class bricks
Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4.
Providing form work with steel plate 3.15mm thick welded with angle iron in frame 30x30x5mm so as give a fair finish including centering, shuttering, strutting & propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 Mtrs and removal of the same for insitu-reinforced concrete & plain concrete work Flat surfaces such as soffits and suspended floors, roofs landing and the like foors etc. upto 200 mm in thickness i) Column, beam pillar etc.
Providing and laying cement conc. work 1:1 1/2 :3 ( 1Cement : 1 1/2 Sand : 3 graded stone aggregate 20 mm nominal size ) and curing complete excluding the cost of form work and reinforcement for reinforcement work in (a) foundation, footing bases of coloumns and the like and mass concrete. : Suspended floor roofs, landing and shelves and their support balconies, beams, girders bressumers and cantilever upto floor two level.
Providing Mild / tor steel reinforcement for RCC work including bending and placing in position complete upto floor two level.
Steel work welded in built up sections trusses and framed work including, cutting hoisting, fixing in position and applying a priming coat of red lead paint in beams joists channels, angles, tee , flats with connecting plats or angle and cross beams hip and jack rafters , purlins connected to common rafters and the like.
15 mm cement plaster in single coat on the rough side of brick conc./ stone wall for interior plastering up to floor two level including arrises, internal rounded angles chamfers and/ or rounded angles not more than 80 mm in girth and finished even & smooth. Cement mortar 1:6 ( 1 cement:6 sand)
Distempering two coats with oil bound washable distemper of approved brand and manufacture and of required shade over and including priming with distemper primer of approved brand and manufacture after throughlybrushing the surface from mortar dropping and other forgein matter and also including preparing the surface even sand papering, smooth primer coat with primer.
Finishing wall with water proofing cement paint of approved brand & manufacture and of required shade on undecoratyed wall surface ( 2 Coats ) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials
Applying priming coat over new wood and wood based surfaces after and including prepering the surface by thoroughly cleaning oil,grease,dirt and other foreign matter) sand papering and knotting.Readymixed paint brushing with white lead for priming
Painting two coats(excluding coat) on new wood and wood based surface with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter,sand papering & stopingWith enamel paint other than white
Painting two coat (excluding priming coat) on new steel and other metal surfaces with readymixed paint, brushing to give and even shade including cleaning the surfaces of all dirt, dust and other foreign matter.
Providing and fixing finishing bright finished or /and black enameled iron helical door spring 150mm.
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
Stone soling properly hand packed filling interstices with spalls and consolidating power road roller to raw required gradient and camber including spreading watering and rolling of binding material mooram or earth etc. 100 mm spread thickness .
Providing and laying cement concrete 1:5:10 ( 1 Cement : 5 Sand : 10Graded stone aggregate 40 mm nominal size ) & curing complete excluding the cost of form work in foundation & plinth.
Providing plinth protection 50 mm thick in cement concrete 1:3:6 ( 1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size)
Providing and laying spartic ceremic tiles 5.5 mm thick in flooring (300x300 mm) treads of steps laid on a bed 12 mm thick cement Motar 1:3(1cement : 3 sand) finished with flush painting in white cement.
White glzed tiles 6 mm thick inskirting rising of step and 12 mm thick cment motar 1:3 (1 cement:3 Sand) and joint with cement slurry.
Providing wood work in frames of doors, windows, clerestory, windows and other frames,wroght, framed and fixed in position Ist. Class D- wood
Providing and fixing paneled glazed or Pannel shutters for doors, windows and clerestory window including black enameled iron ball hinges with necessary screw. 40 mm thick Ist class Kail wood
Providing and fixing wire gauge shutters using galvanised M.S. wire guage of I.S. designation 85 G with wire of dia 0.56 mm for doors windows and clerestory windows including bright finished black enamelled iron hinges with necessary screw. Ist. class kail wood 30 mm thick
Providing 40x3 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts nuts and wooden plugs and embedding in cement concrete block 30x10x15 cm. 1:3:6 ( 1cement : 3 sand : 6 graded stone aggregate 20 mm nominal size )
Providing and fixing anodised aluminium sliding door bolt anodised colour and shade with bolts and nuts screws etc. complete (300x16 ) mm.
Providing and fixing allumnium tower bolt (barrel type) anodised transparent or dyed to required shade and colour with screws etc. complete(i) 250x10 mm
Providing and fixing allumnium tower bolt (barrel type) anodised transparent or dyed to required shade and colour with screws etc. complete(ii) 150x10 mm
Providing and fixing aluminium handles anodised trasparent or dyed to required colour of shade with necessary screw etc. complete. 125 mm
Providing and fixing aluminium handles anodised trasparent or dyed to required colour of shade with necessary screw etc. complete. 100 mm
Providing and fixing bright finished hard drawn hooks and eyes
Providing and fixing anodised aluminium work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved makeconforming to IS 733 and IS 1285 anodisedtransparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with rawlplugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth,rustfree, straight, mitred and jointed mechanically where ever required including cleast angle, aluminium, snap beading for glazinge/panelling C.P. brass/stainless steel screws.
For shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provisions for fixing of fitting where ever required including the cost of PVC/neoprene gaskets as required (fittings and glazing/panelling shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/neoprens gasket etc. Glazing with glass panes of 5.50 mm thickness
Filling in plinth with sand under floors including watering ramming consolidating and dressing complete
Providing and laying chequer plate 6 mm thick over cable trench
Providing and fixing 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge.
Providing and fixing ridges or hips 60 cm overall with 0.60mm thick prepainted steel sheets in roofing with hot dipped metalic zinc coated sheets with top coat of regular modified polyster organic coating of 20 microns over 5 microns primer coating + back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts & nuts 6mm dia & prepainted G.I. limpet and bitumen washers complete with all accessories as required as per the direction of Engineer in Charges.
Providing and fixing on wall face PVC (D-plast) rain water pipes 100mm dia pipe.
Providing and fixing on wall faces PVC D-plast) rain water pipes PVC plain bend.
Providing and fixing M.S. BP sheet 1.66mm to 2mm thick in eves board/ facia/ ceiling including cutting and fixing and welding.
Providing and fixing 15cm wide, 45cm overall semi circular plain G.I. sheet gutter with iron brackets 0.63mm thick.
Providing wood work in frames of false ceiling partitions etc. and put in position Ist. Class K wood Long side
Providing and fixing ply wood laying with butt jointing and nails. 6mm thick.
Providing and laying internal & external water supply and sanitary fittings
Providing and laying in tranches gavanised mild steel tubes ( Medium grade) tube fitting (Earth work in ternches to be measured and paid for seprately) 15mm nominal bore.
Providing and fixing to wall celing and floor GMS tubes (Medium grade) fittinngs 15mm nominal bore.
Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete. 110 mm dia
Providing and fixing high pressure PVC spigot and socket, waste and ventilating pipes ISI marked including fixing with approved adhesive etc. complete.90 mm dia
P/F. M.S. Stay and clamps for cast iron (Spun) iron pipes 100mm.
Providing and fixing PVC plain bend ISI marked including fixing with approved adhesive etc. complete.110 mm
Providing and fixing PVC plain double "Y" junction ISI marked including fixing with approved adhesive etc. complete 110 mm
Providing and fixing PVC Collor ISI marked including fixing with approved athesive etc. complete 110 mm
Providing and fixing PVC floor trap ISI marked of self cleaning design including fixing with approved athesive etc. complete 110 mm X 90 mm
P/F vitreous china W.C squatting pan (Indian type WC pan) size 580mm(Orissa pattrn)
ii)P/F vitreous china wash down, W.C squatting pan (Europan type WC pan) with P or S trap oridary closet.
P/F PVC P or S trap for w.c ISI marked including jointing the trap with pan and PVC pipe 110 mm dia.
P/F 10Ltr. PVC low level flushing cistern with internal fittings.
P/F vitreous china wash basin with single hole flat back size 630x450mm.
P/F CP brass waste 32mm.
P/F M.I. Union for wash basin 32mm dia.
P/F 32mm dia lead waste pipes for wash basin including check nuts.
P/F 100mm CP brass grating.
P/F 600x450mm bevelled edge mirror of sperior glass mounted on 6mm thick AC sheet.
P/F CP brass towel rail complete with CP brass bracket size 600x20mm.
P/F 600x120mm class shelf with CP brass bracket and guard rail complete
P/F CP brass bib tap with capstan head (A)15mm dia.
CP brass pillar tap with capstan head 15mmdia.
P/F CP stop cock 15mm dia
P/F PVC Connection pipe with brass union 45 Cm length 15mm nominal size.
P/F brass fullway valve with wheel 15mm.
P/F PVC storage tank 1000Ltr. Capacity (Sintex make) with internal & External fittings.
Constructing main holes with PCC top slab in CM 1:2:4, foundation conc.1:4:8 inside plastring 15mm thick with CM 1:3 inside size 800x800x500mm deep including CI cover with frame with 200mm thick walls of brick masonry in CM 1:3.
P/L cement conc. 1:6:12 (1 cement :6 Sand:12 aggregate 40mm nominal size). In foundation and plinth
R/R masonry / polygonal rubble masonry (uncoursed/ brought to courses) with hard stone of approved quality in foundation and plinth in CM 1:6.
Half brick masonry in common brunt clay building bracks in CM 1:4 second class bricks.
Form work of ordinary timber planking so as to give a rough finish including centering, shuttring, strutting and propping etc. in flate surfaces floor up to200mm thicks.
P/L cement conc. Work 1:2:4 and curing complete excluding cost of form work and reinforcement for reinforced conc. Work in suspended floors.
Providing mild/ tor steel reinforcement for RCC work including bending, binding & placing in position. (Tor Steel).
15 mm thick plaster in single coat on the rough side of brick/ stone walls for interior plastring up to floor two level in CM 1:4.
Cement conc. flooring 1:2:4 laid in one layer finished with a floating coat of neat cement.40mm thick.
Providing Electrical Installation
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required GROUP C
Wiring for light plug with 2x1.5 sq. mm PVC insulated, PVC insulated heat resistant flame retardant (HRFR) and low smoke core flexible copper conductor single core cable in recessed / suface steel conduit alongwith 1 No. 1.5 mm dia HRFRLS / PVC insulated single core copper conductor cable earthing as required.
Wiring for power plug with 2x4 sq. mm PVC insulated, PVC insulated heat resistant flame retardant (HRFR) and low smoke core flexible copper conductor single core cable in recessed / suface steel conduit alongwith 1 No. 1.5 mm dia HRFRLS / PVC insulated single core copper conductor cable earthing as required.
Wiring for sub-main wiring with following size of PVC insulated copper conductor single core cable in surface / recessed steel conduit: - Sub-main 2x2.5 Sq.mm
Supplying and fixing metal box of 180mm x 100mm x 60mm deep (Nominal size) on surface or recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pin 5/6 Amp. piano type switch, connections painting etc. as requiredfor fixing phnolic laminated sheet cover in front including painting etc. as required.
Supplying and fixing metal box of 180mm x 100mm x 60mm deep (Nominal size) on surface or recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pin 15/16 Amp. socket outlet and 15/16 Amp.piano type switch, connections painting etc. as requiredfor fixing phnolic laminated sheet cover in front including painting etc. as required.
Supplying and fixing ceiling rose on the existing juction box / wooden block including connections etc. as required
Supplying and fixing Ding-Dong / Electronic bell suitable for D.C. / A.C. single phase 230 volts complete as required.
Supplying and fixing of wall mounted metal boards for switch gear mounting of suitable size with permissible variation in size of plus minus 5mm welded frame work made of M.S. angle iron 50 mm x 50mm x 6 mm thick duly welded complete with 3 mm thick M.S. sheet fixed with hinges as open able front complete with locking arrangement including painting and bonding to the existing earth as required.
Suppling & fixing 6 amps. To 32 amps. Rating 10 KA breaking capacity 240 volts " C" curves miniature circuit brackers of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing of 40 / 50 /63 Amp.rating 10 KA breaking capacity 240 volts "C" curves miniature circuit breaker of following pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole - Cat - A
Supplying and fixing of following way single pole and neutral sheet steel MCB distribution board 240 volts on surface or recessed with tinned copper bus bar neutral link earth bar dinbar detachable gland plate interconnections including painting earthing etc. as required.
Earthing with copper earth plate 600mmx600 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using charcoal and salt for G.I. or copper plate earth electrode.
Providing and installtion of exhuast fan of following sizes in the existing opening including making the hole to suit the size of above fan making good the damages connections testing and commissioning etc. as required. Exhuast fan light duty (Domestic) 225 mm sweep
Providing and fixing following type of surface mounting T5 liminairs with powder coated CRCA sheet steel housing mirror optics reflector electonic ballast decorative end caps suitable for 28 watts FTL (T5) complete with all accessories connections testing and commissioning etc as required 1x28 watts - FTL(T5) Category A
Providing and installation of stationary storage type electric water heater geyser of various size by means of expansion board with nuts an dwashers including beading of expansion board in the wall providing and fixing of non return valve dead weigh safety valve two nos, C-R connection rods 18" long making good the damages electric connections safety valve connections testing & comissioning etc, as required. 25 ltrs. capacity CAt-A
Providing and fixing 1.5 ton AC having 5 star rating complete in all respect
Providing and fixing 10 litres storage type gyser complete in all respect
Providing and fixing LED gate light 25 watt Crompten make complete in all respect
ARUN ELECTRICALS INDIA
Shyam Indus Power Solutions Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .