Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.9 LAccepted-AOC | ₹99.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹1.2 CrRejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | ₹1.2 Cr | L2 | Rejected-Finance Other then lowest bidder |
| 3 | L3₹1.2 CrRejected-Finance | ₹1.2 Cr | L3 | Rejected-Finance Other then lowest bidder |
| 4 | L4₹1.2 CrRejected-Finance | ₹1.2 Cr | L4 | Rejected-Finance Other then lowest bidder |
| 5 | L5₹1.3 CrRejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | ₹1.3 Cr | L5 | Rejected-Finance Other then lowest bidder |
| Sl No | Description | Qty | Unit | J P SINGHAL AND COMPANY L7 | M/S Tanisha Traders L2 | THE SHIVAM ENTERPRISES L6 | Abhishek Enterprises L5 | Parth Infrastructure Pvt. Ltd. L3 | divyarsh entrprise L4 | Anil Builders L8 | UMA CONSTRUCTION L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and all directed. | 1,813.98 | Sqm | 40 ₹72,559.20 | 25 ₹45,349.50 | 100 ₹1.8 L | 50 ₹90,699 | 25 ₹45,349.50 | 22 ₹39,907.56 | 25 ₹45,349.50 | 50 ₹90,699 |
| 2.00 | Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and all directed. | 573.87 | Cum | 700 ₹4.0 L | 125 ₹71,733.75 | 200 ₹1.1 L | 325 ₹1.9 L | 180 ₹1.0 L | 350 ₹2.0 L | 350 ₹2.0 L | 200 ₹1.1 L |
| 3.00 | Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and all directed. | 453.31 | Cum | 310 ₹1.4 L | 65 ₹29,465.15 | 100 ₹45,331 | 225 ₹1.0 L | 100 ₹45,331 | 80 ₹36,264.80 | 100 ₹45,331 | 190 ₹86,128.90 |
| 4.00 | Returning, filling in, incl spreading, leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified and all directed. | 370.16 | Cum | 140 ₹51,822.40 | 55 ₹20,358.80 | 100 ₹37,016 | 90 ₹33,314.40 | 110 ₹40,717.60 | 85 ₹31,463.60 | 100 ₹37,016 | 250 ₹92,540 |
| 5.00 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and all directed. | 42.5 | Cum | 5,500 ₹2.3 L | 3,950 ₹1.7 L | 4,500 ₹1.9 L | 4,500 ₹1.9 L | 5,800 ₹2.5 L | 3,850 ₹1.6 L | 4,250 ₹1.8 L | 5,400 ₹2.3 L |
| 6.00 | M&L for brick work with sub class B brick straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and dircted by engr-in-charge. | 79.5 | Cum | 6,000 ₹4.8 L | 5,100 ₹4.1 L | 6,000 ₹4.8 L | 5,500 ₹4.4 L | 6,200 ₹4.9 L | 5,550 ₹4.4 L | 6,200 ₹4.9 L | 6,000 ₹4.8 L |
| 7.00 | M&L for 10mm thick cement plaster in CM 1:6 on concrete or brick wall surfaces finished even & smooth without using extra cement complete all as specified | 28 | Sqm | 260 ₹7,280 | 200 ₹5,600 | 250 ₹7,000 | 290 ₹8,120 | 750 ₹21,000 | 198 ₹5,544 | 280 ₹7,840 | 320 ₹8,960 |
| 8.00 | M&L for 15 mm rendering in two layers ie first layer 10 mm thick in CM 1:6 & further 5 mm thick with CM (1:4) using water proffing compound on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified. | 82.25 | Sqm | 390 ₹32,077.50 | 200 ₹16,450 | 280 ₹23,030 | 329 ₹27,060.25 | 350 ₹28,787.50 | 215 ₹17,683.75 | 450 ₹37,012.50 | 90 ₹7,402.50 |
| 9.00 | M&L for accommodation facility (01 BED) (20ft X 10ft X 8.5ft) with attached Toilet & fully furnished single Sharing accommodation in each room with single Bed, 2 Almirah, 01 dressing table, 01 Instant Geyser 10 ltr capacity energy efficient, with fixtures and conncetions incl hot and cold water tap, 3'x3' window, 6'x3' door, LED light 12 watts-04 Nos, PVC Cabin fan 400mm-02 Nos LED Backlight 10 watts-01 all as specified and as directed by Engineer-in-Charge/GE. | 1 | Each Job | 5,50,000 ₹5.5 L | 4,87,000 ₹4.9 L | 5,30,000 ₹5.3 L | 5,45,850 ₹5.5 L | 4,25,000 ₹4.3 L | 4,71,000 ₹4.7 L | 5,70,000 ₹5.7 L | 3,35,000 ₹3.4 L |
| 10.00 | M&L for accommodation facility OFFICER (02 BED) (2 × 2) (20ft X 10ft X 8.5ft) with attached Toilet, fully furnished double Sharing accommodation in each room with single Bed, 2 Almirah, 1 Dressing Table, 01 Instant Geyser 10 ltr capacity energy efficient, with fixtures and connections incl hot and cold water tap, 3'x3' window, 6'x3' door, LED light 12 watt-04 Nos, PVC cabin fan 400 mm-02 Nos, LED Backlight 10 watts-01 all as specified and as directed by Engineer-in-Charge/GE. | 2 | Each Job | 5,50,000 ₹11 L | 5,24,000 ₹10.5 L | 5,50,000 ₹11 L | 5,25,999 ₹10.5 L | 4,50,000 ₹9 L | 4,81,000 ₹9.6 L | 6,15,000 ₹12.3 L | 3,58,000 ₹7.2 L |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
26 Sept 2025, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
PROVN OF CONTAINERISED ACCN FACILITY TOILET BLOCK SITE OFFICES AND EXTERNAL SERVICES AT AF STN DEESA UNDER GE AF BARODA
2025_MES_724852_1
82241/BRD/E8
Open Tender
Civil Works
180 days
DEESA
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE (AF) Baroda
₹2.1 L
22 Dec 2025
7 Aug 2025
4 Oct 2025
7 Aug 2025
26 Sept 2025
10 Sept 2025
8 Aug 2025 - 28 Aug 2025
Amount
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and all directed.
Excavating in trenches n exc 1.5 m wide and n exc 1.5m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and all directed.
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and all directed.
Returning, filling in, incl spreading, leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified and all directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and all directed.
M&L for brick work with sub class B brick straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and dircted by engr-in-charge.
M&L for 10mm thick cement plaster in CM 1:6 on concrete or brick wall surfaces finished even & smooth without using extra cement complete all as specified
M&L for 15 mm rendering in two layers ie first layer 10 mm thick in CM 1:6 & further 5 mm thick with CM (1:4) using water proffing compound on fair face of wall or on concrete surfaces finished even and smooth without using extra cement complete all as specified.
M&L for accommodation facility (01 BED) (20ft X 10ft X 8.5ft) with attached Toilet & fully furnished single Sharing accommodation in each room with single Bed, 2 Almirah, 01 dressing table, 01 Instant Geyser 10 ltr capacity energy efficient, with fixtures and conncetions incl hot and cold water tap, 3'x3' window, 6'x3' door, LED light 12 watts-04 Nos, PVC Cabin fan 400mm-02 Nos LED Backlight 10 watts-01 all as specified and as directed by Engineer-in-Charge/GE.
M&L for accommodation facility OFFICER (02 BED) (2 × 2) (20ft X 10ft X 8.5ft) with attached Toilet, fully furnished double Sharing accommodation in each room with single Bed, 2 Almirah, 1 Dressing Table, 01 Instant Geyser 10 ltr capacity energy efficient, with fixtures and connections incl hot and cold water tap, 3'x3' window, 6'x3' door, LED light 12 watt-04 Nos, PVC cabin fan 400 mm-02 Nos, LED Backlight 10 watts-01 all as specified and as directed by Engineer-in-Charge/GE.
M&L for accommodation facility WOs (3x2) (02 BED) (20ft X 10ft X 8.5ft) with fully furnished-Two Men accommodation in each room with Bunk Bed with 2 Almirah, 1 Dressing Table, 01 instant Geyser 10 ltr capacity with fixtures and connections incl hot and cold water tap, 3'x3' window, 6'x3' door LED light 12 watt-04 Nos, PVC cabin fan 400mm-02 Nos, LED Backlights 10 watts-01, Two power point for AC including metal clad porcelain socket with metal plug top controlled with 16 Amps MCBs, all as specified and as directed by Engineer-in-Charge/GE. Note for Item 9 TO 11 . 1. The Other Specification Include:- Base Frame:- 1. Bottom Frame 100mm X 50mm "C" channel 2. Stiffener Bottom 100mm x 50 mm 1 Beam. 2. Side and End Walls 1. Paneling outside Specially G I Sheet (Galvanized Sheet) 2. Internal Wall Paneling 8 mm MDF/OSL Sheet. 3. All Steel Sheets Used tested for corrosion resistance. 4. All gap sealed at edges & at seams, bottom etc.for preventing nearess of moisture. 3. Flooring System: 1. Bottom flooring 18mm Cement Fiber Board of self-tapping screws) 2. Vinyl Carpet fixed on panel as directed by Eng-in-Charge. 4. Roof: 1. Roof outside Specially (Galvanized Sheet) Property Stopped and water tight. 2. False Ceiling 8mm MDF-Plane White. 5. Paint: 1. Outside Painting Phosphate the Cabin and painting with 1 coat of epoxy primer with Two Coat of Epoxy Paint. 6. Insulation: 1. Insulation glass Wool density of 16kg/m3RB Wool Insulation. 7. Main Entry Door: 1. Door with for locking agreement, Hold Draft & Handles.Aluminum Windows: 1. Aluminum Windows Double Shutter Sliding Aluminum Powder Coated Windows ASIS with Safety Grills. Electrical Systems and Wiring 1. All wiring shall be concealed type & shall be of copper wire. All electrical fitting in the portable cabin shall be 220-240 V, AC 50Hz Tubes Door Light, Fan, Switches, Socket, Telephone, Air Conditioners Point (MCB) All Type of Window Air Conditioning Systems as desired upon can be installed. Earthling point shall be provided for saftey.
1. Supply and install split Air conditioning unit (White), inverter type with split units indoor/outdoor with insulated copper tubing, Copper condenser coil, precision cooling technology, dual rotor inverter technology, R32 / R22/R410 or any other ecofreindly Refrigerant, Brushless DC motor, 4-in-1 Convertible Cooling, auto clean, Magic Display Ecofriendly refrigerant, copper wound rotary compressor complete with cordless remote control unit, Stand for outdoor unit and dust filter for batter indoor air quality5 siar rating ISEER 4.51 and of capacity 1.5 TR as comprising of the following:- (a) 1.5 Ton capacity using Eco friendly refrigernt cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. (b) One No condensing unit of 1.5 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condensor with fixing of stand on Wall and including one voltage stabilizer of 3 KVA single phase with all necessary controls and accessories all as specified and directed by Engr-in-charge. Note :- (i) Additional length for copper tubing if required at site shall be supply and fix by the contractor without any extra cost. (ii) Rate for filling of hole with white cement/POP including matching with existing surface included in item rate.
M&L for sand filling under floors or in foundations incl watering and consolidation etc complete all as specified and as directed. (Note : Punned thickness shall be measured for sand cushioning of UG cable).
M&L for machine pressed precast concrete interlocking paver block any shape and size cofirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment complete all as specified and directed by Engr-in-charge.
M&L for PCC type B0 1:2:4 (12.5mm aggregate) for coping complete all as specified and as directed.
M&L PCC 1:2:4 type B1 20mm graded aggregate in foundation of the LT Panel including form work and all as directed by Engr-in-Charge
M&L for Bricks common burnt clay building bricks, sub-class 'B' designation of size 230mm x 115mm x 40mm for cable protection all as directed by Engineer-in-charge.
Supply, laying, testing and commissioning of XLPE insulated LT U/G cable heavy duty,1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 4 core 16 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and as directed.
Supply, laying, testing and commissioning of XLPE insulated LT U/G cable heavy duty, 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 95 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and as directed.
Supply, laying, testing and comminssioning of XLPE insulated LT U/G cable heavy duty, 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 185 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and as directed.
Supply, install, commissioning and testing factory made (CPRI approved manufacturer) LT panel box (KIOSK) out door type slze not less then 1500mm (W)x1500mm (H) x 500mm (D) platform mounted suitable for 415 volt, 3 phases, 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 400 amps rating installed on percelain insulators the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB Volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height .2 Nos earth terminal to be welded with feeder piller. The Complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (For Porta cabine) Incomer :- (a) MCCB FP 160 A, 36 KA with Electronic microprocessor release with over load Zone of adjustment 0,4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 8.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
Supply, install, commissioning and testing factory made (CPRI approved manufacturer) LT panel box (KIOSK) out door type, size not less then 2000mm (W)x 2000mm (H) x 550mm (D) platform mounted suitable for 415 volt, 3 phases, 4 wire, 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height. 2 Nos earth terminal to be welded with feeder piller. The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified:- (Location - NearMT) Incomer :-
(i) RYB LED incating lamp -3 Nos Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item. (ii) Earth work, PCC base as directed by Engr-in-Charge etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly. (iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board. wherever required and rate will be inclusive in this item for fixing in other panel or deposited in MES store yard as directed by Eng-in-Charge.
Supply and fixng VTPN load DB 4 way Sheet metal encloser including MCCB 63 Amp 25 KA and MCB SP.
Supply and installation of steel tubular swaged pole complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type confirming to IS 2713 complete including2 coats of aluminium paint over one coat of red oxide primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete. in intenal surfaces of pole including providing 5Nos synthetic enemelled paint bends (in skyblue and white coloure) of 30cm each as in repairs for 410 SP-31 (9 mtr long) complete all as specified and directed. Note: Excavation / earth work and PCC work shall be measured and paid separately under respective items of BOQ
Supply and fix in repair 1.5 sqmm three core PVC insulated, PVC sheathed multistranded copper conductor cable 1100 volts grade from junction box to street light fittings complete all as specified and directed
S&F Junction box 290x200x130 mm polycarbonate/ ABS hinged enclosure box IP-66/67 for cable in/out of street light LT cable, out door type, testing and commissioning with locking arrangements fixed on poles, 4 poles 100 Amp connector/ terminal assembly with nut bolt and washer, including MCB SP 6A, 240V, 10 KA -01 Nos for connecting suitable size of XLPE UG cable all as specified and directed.
Supply and fix LED street light fitting of 70 Watt LED IP-66, sealed optic luminaire with housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete including 1200mm long Gl pipe (40mm bore) light grade breaket bend to shap, Fl clamp 50mm X6mm-2 Nos all as specified below- (i) The fixture shall be designed so as to average lumen maintenance of at least 70% at the end of 70000 hours. (ii) The luminaire should be operable with auto adjustable 120-240 volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. (iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be nore than 85%. (iv) The fixture should be dark sky complaint. The fixture should use aluminium, MCPCB printed circuit boards for better thermal management. (v) The luminaire should throw the perfect amount of uniform light
Earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1,5 metres below normal around level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 and connected to earthing test point all as specified or indicated including testing on completion including excavation & earth work in any type of soil/strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in: reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade Gl watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra..
M&L Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x6 mm burried directly in ground vetically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised eath lead as GI strip of 32X6mm size by means of bolts, nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation & earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in: reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade Gl watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra.
Supply & laying in trenches 100mm bore DI pipe Class K-7 With tyton Rubber joint and fittings complete all as specified & directed by Engr-in-Charge.
Supply & laying in trenches/Walls 25mm GI medium grade, ISI marked with GI fitting such as tees, bend, elbows connecting to existing water main all as directed by the Engr-in-Charge.
Supply and fixing of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified & directed by Engr-in-Charge.
Supply and fixing sluice valve. 100mm bore flanged type of class 1.6 PN includes rubber packing and nuts and bolts required complete all as specified & directed by Engr-in-Charge.
M&L for valve pit chamber of size 1000mmx1000mmx1000mm with angle Iron frame 50x50x6 mm, 3 mm thick MS cover, excavation work, 10 mm thick plastering in CM 1:4 inside and outside, coping 50mm in cement concrete 1:2:4 type B1, Brick masonry of 23 mm thick in cm 1:4, PCC 1:3:6 in foundation work earth and excavation work in any type of soil complete Job all as directed by Engr-in-Charge.
M&L for common Toilet Bunk House (20'ftX10'ftX8.5"ft) with fully furnished with Shower-3, Toilet EWC-3 Nos and Wash Basin -2 Nos, PVC exhust fan 300mm with louvers-06 Nos, two power point for Geyser incl 02 Nos Instant Geyser 10 Ltr capacity with fixtures and connections incl hot and cold water tap, LED light 12 watts- 08 Nos etc, all as specifed and as directed by Engr-in-Charge.
Note for item No 37. 1. The other specification including-Base Frame :- (i) Bottom frame 100mmx50mm "C" channel. (ii) Stiffener Bottom 100mm x 50mm 1 Beam. 2. Side and End Walls :- (i) Panelling outside specially G I Sheet (Galvanized Sheet) (ii) Internal Wall Paneling 8mm MDF OSL Sheet. (iii) All steel sheets used tested for corrosion resistance. (iv) All Gap sealed at edges & at seams, bottom etc for preventing nearess of moisture. 3. Flooring System :- (i) Bottom flooring 18mm Cement fiber Board (Fixed by means of self- tapping screws) (ii) Vinyl Carpet Fixed on panel. 4. Roof :- (i) Roof outside specially (Galvanized Sheet) Properly stopped and water tight. (ii) False ceiling 8mm MDF-Plane white 5. Paint :- (i) Outside Painting Phosphate the Cabin and painting with 1 coat of epoxy primer with Two Cost of Epoxy Paint 6. Insulation :- (i) Insulation glass wool density of 16kg/ M3 RB wool insulation. 7. Main Entry Door :- (i) Door with for locking arrangement, Hold fast & Handles. 8. Aluminum Windows :- (i) Aluminium Windows Double sliding Aluminum Powder Coated Windows ASIS with Safety Grills. Electrical systems and wiring :- (ii) All wiring shall be concealed type & shall be of copper wire. (iii) All electrical fitting in the portable cabin shall be 220-240 V, AC 50Hz Tubes Door Light, Fan, Switches, Socket, Telephone, Air Conditioning Point (MCB). (iv) All type windows Air Conditioning Systems as desired upon can be installed. 4 Sq mm GI wire earthing with GI plate as per SSR Pt-1 Plate No 03 complete connected to DB point shall be provided for safety.
M&L for RCC NP3 150 mm diameter Pipes for depth 0.7m to 1.65m laid on150 mm thick bed PCC 1:4:8 with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional in all respect complete all as specified and directed.
M&L for 10 user capacity conventional type on site LLDPE septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed by Engr-in-Charge/ GE.
M&L for 30 user capacity conventional type on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete all as specified and directed by Engr-in-Charge/ GE.
M&L for soakage well of size 1.8M dia and 3.0 M effective depth, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of appropriate size complete all as specified and directed by Engr-in-Charge/ GE.
M&L for Office facility (1 x 2) (20'ft x 10'ft x 8.5'ft) with fully furnished- 2 Almirah, Table 4, Side table 2, Chair 8, 1.5 Air conditioning, LED light-4, Fan-2, Backlight-1 all as specified and directed by Eng-in-Charge/GE.
M&L for Office facility (5 x 4) (20'X10'X8.5') with fully furnished- 2 Almirah, Table 4, Side Table-2, Chair-8, 1.5 Air conditioning, LED Light-4, Fan-2, Backlight-1 all as specified and directed by Eng-in-Charge/GE. Note for item No 42 & 43 1. The other specification include:- (i) Base Frame-1Bottom, Frame 100mm X 50mm 'C' channel (ii) Stiffener Bottom 100mm x 50mm 1 Beam. 2. Side and End Walls :- (i) Paneling outside Specially G.I Sheet (Galvanized Sheet) (ii) Internal wall paneling 8 mm MDF OSL Sheet (iii) All steel sheets used tested for corrosion resistance. (iv) All gap sealed at edges & seams, bottom etc for preventing nearess of moisture. 3. Flooring system :- (i) Bottom flooring 18mm Cement Fiber Board (Fixed by means of self tapping screws) (ii) Vinyl Carpet fixed on panel. 4. Roof outside specidly (Galvanised sheet). (i) Properly stopped and water tight. (ii) False ceiling 8mm MDF- plane white. 5. Paint :- (i) Outside Painting phasphate the Cabin and painting with 1 coat of epoxy primer with Two coats of Epoxy paint. 6. Insulation. :- (i) Insulation glasss wool density of 16 kg/m3RB wool insulation. 7. Main Entry Door :-(i) Door with for locking agreement. Hold fast & Handles Aluminum Windows. (i) Aluminium Windows Double Shutter sliding Aluminium Powder Coated Windows ASIS with Safety Grills. Electricals system and Wiring. (ii) All wiring shall be concealed type & shall be of copper wire. All electrical fitting in the portable cabin shall be 220-240 V. AC 50Hz Tubes Door Light, Fan, switches, Socket, Telephone, Air Conditioners Poiint (MCB) All type of Window Air Conditioning Systems as desired upon can be installed Earthing point shall be provided for safety.
M/S Tanisha Traders (BID ID -3427457)
Parth Infrastructure Pvt. Ltd. (BID ID -3429977)
divyarsh entrprise (BID ID -3430033)
Abhishek Enterprises (BID ID -3429961)
THE SHIVAM ENTERPRISES (BID ID -3427873)
J P SINGHAL AND COMPANY (BID ID -3425617)
Anil Builders (BID ID -3435772)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid