| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.4 LAccepted-Finance DOOR NO 3 533 COOPER ELEVATORS INDIA PRIVATE LIMITED BELL NAGAR MADHANANDAPURAM CHENNAI TAMIL NADU 600116 | THIRUVALLUR | TAMIL NADU | 600116 | L-1 | Accepted-Finance Evaluated price(Incl. GST) of deemed single bidder is acceptable | |
| 2 | Rejected-Technical CHINAR PARK RAJARHAT OPPOSITE TO TEGORIA LOKNATH MANDIR K R PLAZA GROUND FLOOR KOLKATA 700157 | KOLKATA | KOLKATA | WEST BENGAL | 700157 | - | Rejected-Technical Techno-commercially not acceptable | |
| 3 | Rejected-Technical | - | Rejected-Technical Techno-commercially not acceptable |
Tender Value
Refer Docs
EMD Value
₹24,800
Closing Date
18 Apr 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM M and C
SRPL Chennai
Supply, Installation and Commissioning of Passenger Lift at C-Block of SRPL Chittoor Colony
2023_SRCHN_164696_1
SRPL22C094
Open Tender
Civil Works
Works
120 days
Chittoor
Please refer Tender documents.
6 documents required · 6 mandatory
₹24,800
Yes
30 Aug 2023
30 Mar 2023
19 Apr 2023
30 Mar 2023
18 Apr 2023
5 Apr 2023
Amount
Lift for Chittoor Colony
Supply, installation & commissioning of MRL Passenger Lift for G+4 floors, 6 persons capacity with SS full vision doors at all landi ngs, SS Car with Automatic Rescue Device, 5HP Gearless Traction motor and all other features as per technical specifications mention ed in the tender
Providing and laying in position cement concrete of specified grade
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]
Providing and laying Polished Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) on floors & walls in re quired design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawing s, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed wit h cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishin g etc. all complete as specified and as directed by the Engineer-in-Charge.
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to fl oor V level in all shapes and sizes in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of u nserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed du ring day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M. S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connect ion with the building etc wherever required for inspection of work at required locations with essential safety features for the work men etc. complete as per directions and approval of the Engineer-in-Charge. The elevational area of the scaffolding shall be measure d for payment purpose. The payment will be made once irrespective of duration of scaffolding. [Note: This item to be used for mainte nance work judicially, necessary deduction for scaffolding in the existing item to be done]
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour
New work (two or more coats) over and including water thinnable priming coat with cement primer.
Plastering: 12 mm cement plaster of mix :
1:4 (1 cement : 4 fine sand)
Supplying and drawing following size of FRLS PVC insulated, copper conductor, single core cable in the existing surface / recessed, PVC / steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used.
4C x 6 sq.mm
Supplying and drawing following size of FRLS PVC insulated, copper conductor, single core cable in the existing surface / recessed, PVC / steel conduit / PVC casing and capping as required. Note: Only ISI marked cables shall be used.
2C x 1.5 sq.mm
Supply, fixing in position, installation, connection, testing and commissioning of the following LED Light Fittings rated for 240V, 50Hz, 1-ph AC fo the make of Philips/Osram/Havells/Wipro/Bajaj/Eveready/SYSKA/Oreva/Crompton or equivalant Indian make). Item includ es Installation & Connection of Lighting Fixture on Existing Poles/HMT/FLT, Metallic Structures, Walls, Buildings, Roofs, Sheds and other facilities upto a height of 30m, removal of the, Complete in All respect with Materials, Transportation, Labor, Tools etc..
15W, LED Bulb/Lamp, 230V AC, 50Hz
Supply and installation of MCB / Isolator/ RCCB/ELCB of following rating as per direction of Engineer-in-Charge.
40 amps. to 63 amps. ratings , 4 Pole MCB, “C” curve,10 KA breaking capacity
EARTH STRIP / WIRE / ROPE / CABLE Supply, installing and testing of earthing strip/wire/rope/cable for completely making the earthin g grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electro des and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Engineer-in-charge , including the cost of all labour, tools, materials, etc. complete in all respect.
GI wire (8 SWG)
AMC post Defect Liablility period
Comprehensive AMC which includes free replacement of defective parts / equipment / panel / any item supplied for installation & commissioning of elevator etc. and Monthly maintenance like oiling / greasing, checking of whole lift for defaults, all related errors and submission of reports as directed by EIC and as per tender terms and conditions etc.
Post Defect liability period - 2nd year
Post Defect liability period - 3rd year
Post Defect liability period - 4th year
Post Defect liability period - 5th year
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .