Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 CrAccepted-AOC | ₹1.0 Cr | 1 | Accepted-AOC AoC |
| 2 | 2₹1.0 Cr+₹2.9 L (2.91%)Rejected-AOC | ₹1.0 Cr+₹2.9 L (2.91%) | 2 | Rejected-AOC Rejected |
| 3 | 3₹1.1 Cr+₹6.1 L (6.11%)Rejected-AOC | ₹1.1 Cr+₹6.1 L (6.11%) | 3 | Rejected-AOC Rejected |
| 4 | 4₹1.1 Cr+₹9.1 L (9.05%)Rejected-AOC | ₹1.1 Cr+₹9.1 L (9.05%) | 4 | Rejected-AOC Rejected |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
21 Dec 2020, 5:00 pmClosed
EE RWSS DIVISION BALASORE
O/O EE RWSS DIVISION BALASORE
RPWS WITH RCC ESR
2020_RWSS_64580_1
TCN NO. 17 DT. 04-12-2020
National Competitive Bid
Civil Works - Water Works
Lump-sum
330 days
BALASORE
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹1.1 L
Yes
21 Apr 2021
15 Dec 2020
28 Dec 2020
15 Dec 2020
21 Dec 2020
15 Dec 2020
15 Dec 2020 - 20 Dec 2020
Amount
Laying and Jointing PVC Pipe. Heading
Supplying all materials , labour , T&P , design , drawing , soil testing etc. complete in all respect for construction of RCC Roof building pump house and construction of compound wall for pump house and construction of approach road alongwith site Development including laying , testing and commissioning of Rising main & Distribution system pipe line such as UPVC , HDPE , ASTM , GI pipe lines etc. along with required fittings & specials and construction of RCC Valve chambers, public stand posts , individual house hold connection , stand alone , storage tank , installation of Chlorination system , installation of submersible pump with motor in deep Tube well etc. ( Including supply of stand by pump motor ) , internal wiring of pump house & installation of Servo Stabilizer , External Electrification etc. as per supplied Drawing in section - 8 and detail scope of work & Technical specification , Quantity of work mentioned in section - 5 and in ( Annexure - A to H ) of village NUA All materials required shall be supplied by the contractor as per terms and condition of DTCN & all dimentions are as per supplied drawings and as per direction of Engineer- in -charge. All work shall be completed in such a manner that all house hold of entire village will get required quantity of drinking water with residual head of 7.00 mtr and residual chlorine of 0.20 mg/ ltr without any leakage in the entire PWS System.
Design , Drawing , Construction , errection , testing and commissioning of 50,000 ltrs capacity RCC Elevated storage reservoir ( Circular type with spherical dome ) of 15.00 mtr stagging height as per detailed scope of work & technical specification mentioned in section- 5 and in Annexure - I including testing of SBC etc. complete as per direction of Engineer- in -charge.
The contractor shall maintain the PWS Project for five ( 5 ) calender years from the completion date of defect liability period of one year in such a manner that all the house hold of the PWS Scheme covered area will get ( adepuate ) required quantity of supply water taking supply hour as 8 hour / day without facing any problems. The contractor shallrepair and replace any types of defect arise within 24 Hrs of receipt of complain either from public or from Department. The contractor shall maintain all structure of the PWS Schemes as per terms and conditions of DTCN & Technical spacification mentioned in section - 5 and in Annexure - J & K.
CHINTAMANI SETHI
MILAN PANDA
AMRITA PRITAM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .