Supply, Installation, Testing and Commissioning of 3-way RMU and Lightning arrestor in Substation-IV
2024_NITC_822275_1
Engg/EMU/JE3/0009/LA-RMU Service SS-IV/2024-25
Open Tender
Electrical Works
Item Rate
150 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹25,600
Yes
7 Oct 2024
21 Aug 2024
13 Sept 2024
21 Aug 2024
11 Sept 2024
21 Aug 2024
Amount
Supply, Erection, Testing and Commissioning of 11 KV, 630 A, 21kA/3 Sec, 3 way Extensible, indoor motorized RMU comprising of 1 Isolators (LBS) + 2 Circuit Breaker (VCB) AEGIS type +LVV+ as per attached BOM Annexure - I to the existing RMU of Lucy Make.
Supply & laying of 3C X 240 sq mm XLPE 11KV Aluminum armoured cable in trench
Supply & providing of cable end termination for 3CX 240 sq mm 11 KV cable (Indoor type)
Dismantling & Re termination of existing cable end for Transformer No.II
Earthing of RMU using 25 X 3 mm copper strip
Supply & Laying of 3 C X 2.5 sq mm copper armoured cable for battery charger input power
Supply & providing of cable end termination with single compression gland and copper socket for 3 CX 2.5 sq mm. Cu cable
Supply & providing of gland earthing using copper shim for 3 C X 2.5 sq mm cable
Supply & providing of 100 X 50 mm MS Chanel across the built up cable trench for erection of RMU including 2 coat primer and 2 coat Enamel paint as per standard
Final Electrical Inspectorate approval (with necessary documents and charges for inspection including all the related expenses)
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1 meter air terminal rod 16mm dia rod pointed, for 2,3,3.5 meter air terminal rod base dia of rod 16mm and tapered to 10 mm dia & For 4 mtr air terminal rod 22mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. For 1 meter rod threaded insulated base need to use which can be directly fixed on flat areas and for air terminal rods above length concrete stones to be used. If fixed on side walls stainless steel clamps of suitable quantities to handle wind load need to consider Stainless Steel Wall Clamp or 17 KG stone with required diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. Make: Axis
1 meter air terminal with mounting accessories including connection clamp of stainless steel material
Providing & fixing of 8mm solid aluminium round conductor BARH08 with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) semi hard with 50 sq.mm cross sectional area. Tested as per IS IEC 62305 and Indian labs tested. Make: Axis
Providing and fixing Conductor Holder for sheet with stainless steel top and UV resistant base with sticking type to be fixed on metal sheet. No drilling is permitted to avoid water leakage.DCSR0810GB @ every 1 meters
Providing and fixing Conductor with Down Conductor Holder made of weather resistant plastic holder AEL90696M @ every 0.5 meters
Providing and fixing of Cross Connector SSQ0810 to route vertical down conductor /mesh formation made of stainless steel connectors tested for IS IEC 62305. made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Single nut bolt joints not permitted. Usage of Aluminium Ferrule or Galavanised Iron Joints not permitted to avoid risk of corrosion and risk of faulty loose joints and thus reduce risk of flash over. Make: Axis
Providing and fixing of Stainless Steel Test Joint SSQ0810P suitable with suitable Outdoor Enclosure: For 8mmdia solid round aluminium conductor & 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements according to (IS/IEC62305).The enclosure should be outdoor fibre reinforced polycarbonate opaque having minimum inner dimension of 100mm x 100 mm x 55 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Stainless Steel plate need to be inbetween aluminium and copper inorder to avoid bimetallic corsion. Separation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch each other to avoid bimetallic corrosion. Single bolt joints are not permitted. Make: Axis
Providing and fixing copper bonded steel solid round conductor 10mm diameter CCSR7020 from earth electrode directly in ground and ring earthing at a distance of 1 m away from wall and 0.5 mtr depth as required. copper bonded steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. To be connected directly to the earth pit. Tested as per lightning standards. Make Axis
Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3000mm length, having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be continuous in length with fault current withstand capability. Stainless steel clamps AEL91146 recommended for connecting to earth rods with copper bonded conductor. Earth enhancing mineral compound AEL90062 is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. 25 Kg of compound required to be used. It should be free from hazardous substances. The compound should be chemically inert and needs to submit test certificate. Fibre type Earth electrode inspection chamber EPP3030M with weight bearing capacity of 5000 Kgs. The dimension shall be 300mmx 300mm. Test certificates of the compund and earth chamber required.
ELECTRO FINE
NATIONAL ENGINEERING COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .