Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC FIRST FLOOR DOOR NO 3 BQ COMPLEX OPP GRAMAPANCHAYAT MALAYINKEEZHU P O THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695571 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.6 L+₹7,004 (4.55%)Rejected-Finance SMT BHAVANA JOCKIAM ANAPAR D O NEYYATTINKARA TRIVANDRUM | TRIVANDRUM | KERALA | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.8 L+₹24,004 (15.6%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹1.5 L
EMD Value
₹2,310
Closing Date
13 Dec 2021, 1:00 pmClosed
Assistant Manager(Commercial Division)
STEEL INDUSTRIALS KERALA LTD. ATHANI P.O THRISSUR- 680 581
Supply and Installation of 8 Mtr Mini Mast System with 5 Nos. of 150W LED Flood Lights at Kulathur Grama Panchayath
2021_SILK_458721_1
SILK/45/CD/2021-22/896
Open Tender
Miscellaneous Works
Item Rate
30 days
Kulathur Grama Panchayath
As per tender documents
6 documents required · 6 mandatory
₹590
₹2,310
Yes
1 Feb 2022
6 Dec 2021
14 Dec 2021
6 Dec 2021
13 Dec 2021
6 Dec 2021
6 Dec 2021 - 13 Dec 2021
Amount
90.15.1.1 Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 3/4/5/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
(90.14.1.2) Supply installation testing and commissioning of Panel board, (90.16.5.3 2) core 10 sq mm Power cable, (od222298/2020_2021) 25A 2 Pole AC 1 rated power Contactor, (2.10.1) 24 hour Timer, (2.14.2) 32A 2-way neutral links, 5-32 A MCB, 40 A RCCB, HRC Fuse 20/32A, 40A isolator,(od222299/2020_2021, 90.6.5.11) multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables - 3 core 1.50 sq mm, (5.3) Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long (but without charcoal/ coke and salt ) as required, (90.16.4.2) 25 x 3 mm GI strip, (90.16.1.3) bare earthing conductors 3.15 mm copper conductor ( 10 SWG), (90.16.5.3)copper earth socket 3.15 mm (10 SWG), (90.12.9.2) double wall corrugated (DWC) pipe, (90.1.2)brass compression gland and aluminium lugs 2 X 10 sq. mm (19mm) and all accessories.
90.15.4.9 Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
(2.6.1)Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil, (4.1.8)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size), (5.9.1)Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete, (5.22.6)Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more, (5.1.2)Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size, (13.1.1)12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand), (2.25)Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
od69_P600004/2021_2022 Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc.
od106_P600004/2021_2022 Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt).
S K ELECTRICALS
SOLARVALLEY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .