Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAdmitted-Fee/PreQual/Technical/Finance | ₹7.6 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹8.3 L+₹68,194.31 (9.00%)Admitted-Fee/PreQual/Technical/Finance | ₹8.3 L+₹68,194.31 (9.00%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | K KHALID L2 | ANAZ BABU K L1 |
|---|---|---|---|---|---|
| 1.00Construction of screening arrangements in the existing manholes in the Hostel area of medical college, and repair works of existing sewer lines and drains Manjeri | |||||
| 1.00 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources) | 2.99 | cum | 9,772.4 ₹29,209.7 | 8,965.49 ₹26,797.85 Lowest |
| 1.00 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | 4.32 | sqm | 370.2 ₹1,599.26 | 339.63 ₹1,467.2 Lowest |
| 1.00 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) | 240 | kg | 768.7 ₹1,84,488 | 705.22 ₹1,69,252.8 Lowest |
| 1.00 | 10.27.3:Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x120 mm | 48 | no | 181.5 ₹8,712 | 166.54 ₹7,993.92 Lowest |
| 1.00 | OD33527/2026-2027:Supplying and fixing 900x900 mm size 5 T capacity FRP manhole cover ( heavy duty ) (Ref:19.18.1) | 8 | each | 21,255 ₹1,70,040 | 19,500 ₹1,56,000 Lowest |
| 1.01 | OD33528/2026-2027:Supplying and fixing 900x900 mm size 12.50 T capacity FRP manhole cover ( heavy duty ) (Ref:19.18.1) | 6 | each | 25,070 ₹1,50,420 | 23,000 ₹1,38,000 Lowest |
| 1.01 | OD366566/2025-2026:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.160 mm dia 6Kgf/cm2 (Ref:50.18.9.9.1) | 100 | metre | 817.5 ₹81,750 | 750 ₹75,000 Lowest |
| 1.01 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow | 6 | no | 119 ₹714 | 109.22 ₹655.32 Lowest |
| 1.01 | 50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap | 6 | no | 83.6 ₹501.6 | 76.69 ₹460.14 Lowest |
Tender Value
₹6.9 L
EMD Value
₹17,266
Closing Date
31 Jul 2026, 11:00 amClosed
Assist.Exe.Engineer pwd buildings sub divn Manjeri
Assist.Exe.Engineer pwd buildings sub divn Manjeri
DEPOSIT Waste treatment facilities in Medical Colleges Necessary civil Electrical works for diversion of waste to STP at Govt Medical College Manjeri General Civil Work
2026_PWD_860574_1
D3/PWD/BLDG/TR/5089/2026 Dt 7/14/2026
Open Tender
Civil Works - Buildings
Item Rate
300 days
Manjeri
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,525
Yes
₹17,266
Yes
4 Aug 2026
14 Jul 2026
3 Aug 2026
14 Jul 2026
31 Jul 2026
14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Construction of screening arrangements in the existing manholes in the Hostel area of medical college, and repair works of existing sewer lines and drains Manjeri | |||||
| 1.001 | 4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3
graded stone aggregate 20 mm nominal size derived from natural sources) | 1 | cum | - | - |
| 1.002 | 13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) | - | sqm | - | - |
| 1.003 | 10.28:Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) | - | kg | - | - |
| 1.004 | 10.27.3:Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide P A 6 grade sleeve, including drilling of hole in frame, concrete/masonry, etc. as per direction of Engineer-in-charge.10x120 mm | - | no | - | - |
| 1.005 | OD33527/2026-2027:Supplying and fixing 900x900 mm size 5 T capacity FRP manhole cover ( heavy duty ) (Ref:19.18.1) | - | each | - | - |
| 1.006 | OD33528/2026-2027:Supplying and fixing 900x900 mm size 12.50 T capacity FRP manhole cover ( heavy duty ) (Ref:19.18.1) | - | each | - | - |
| 1.007 | OD366566/2025-2026:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.160 mm dia 6Kgf/cm2 (Ref:50.18.9.9.1) | - | metre | - | - |
| 1.008 | 50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow | - | no | - | - |
| 1.009 | 50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap | - | no | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.06 MB
Affidavit.pdf
Tender Documents • 0.41 MB
epay.pdf
Tender Documents • 0.01 MB
form.pdf
Tender Documents • 0.18 MB
integritypact.pdf
Tender Documents • 0.05 MB
preliminaryAgreement.pdf
Tender Documents • 0.30 MB
viewsbd5089.pdf
Tender Documents • 1.64 MB
BOQ_1455261.xls
BOQ • 0.31 MB
DateExtension.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .