Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 33 DOMALGUDA ARAVIND NAGAR COLONY DOMALGUDA HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 20 21 ETA HOUSE RAZAK GARDEN MAIN ROAD RAZAK GARDEN MAIN ROAD CHENNAI TAMIL NADU 600106 | CHENNAI | TAMIL NADU | 600106 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
16 Sept 2023, 4:45 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer (CED PD EP)
Electrical projects 2 nd floor Sarathi Building Nuclear Fuel Complex Hyderabad 500062
VRF VRV Air conditioning system with Air Cooled ODU s Refrigerant copper piping Insulation power cabling, control cabling, earthing structural steel fabrication works MCC panel etc for New Computer Division Bldg
2023_NFC_767117_1
E651
Open Tender
Electrical Works
Works
240 days
Hyderabad
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2.8 L
18 Sept 2023
18 Aug 2023
18 Sept 2023
18 Aug 2023
16 Sept 2023
21 Aug 2023
21 Aug 2023 - 26 Aug 2023
Amount
OUTDOOR UNITS: SITC of VRF/ VRV System - Supplying, Installation, Testing and Commissioning of Variable Refrigerant Flow / Variable Refrigerant Volume modular type air-conditioning system suitable of all weather proof for COOLING with variable frequency drive based technology, having all hermetically sealed inverter type scroll Compressor minimum ONE Compressor for above 20 HP moduels, microprocessor based controller, top discharge type condensing unit(s) with R-410 A / Eco-friendly refrigerant, vibration isolators, with suitable foundation etc. complete as required. The ODU unit shall deliver the rated capacity at AHRI conditions and work even at 50 Deg C ambient temperature without tripping . ODU unit shall be fitted with low noise propeller type aero spiral fan, condenser coil, refrigerant shut off valves, safety devices, including ODU Refnet , etc. The unit shall be suitable to work on 400 V +/- 10% , 3 phase, 50 Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 0.5. ODU unit shall be equipped with an oil recovery sytem to ensure stable operation with long refrigerant piping. Condensing unit shall be modular type , designed as per Indian atmospheric conditions and should be capable to perform for Outside Ambient temperarture 52 Deg. C. Total required Cooling Capacity of AC system for Building - 144 HP . ODU's should be installed on the Terrace of the Bldg. ( III floor ). NOTE :- (i) AC System should deliver its 100% Cooling capacity at 43 Deg C ( ambient temp.) (ii) AC System shall be provisioned such that, even if the power supply to any Indoor unit (IDU) is cut-off , the rest of the AC system shall be able to to continue to function normally
Supply of Outdoor (ODU) Units - 24 HP capacity
Erection of Outdoor (ODU) Unts -24 HP Capacity
INDOOR UNITS ( Ceiling suspended Cassette type AC) Supplying, installation, testing and commissioning of following minimum capacity 4-way flow - VRF/VRF based - ceiling mounted Cassette type Indoor unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve , outer cabinet , high lift drain pump, fresh intake provision , shall have four way supply air grills on sides & return air girll in center , cord less remote control with LCD display for controlling the indoor unit, display, addressable panel, required refnet joints etc. complete as required suitable for operation on Single Phase, 230 Volts, +/- 10%, 50 Hz. AC supply, complete as required. The IDU shall have automatic force shut down provision in case of fire on recieving signal from BMS system . The Cooling capacity of Indoor Unit will be at air inlet condition of 27 Degree C DB and 19 Degree C WB temperature. NOTE : Each Cassette type AC (IDU) Unit shall be provided with Corded remote controller with LCD display and cordless remote controller.
Supply of 1.5 TR, Ceiling suspended - Cassette type Indoor unit.
Erection of 1.5 TR Ceiling suspended - Cassette type - Indoor unit
Supply of 2.0 TR, Ceiling suspended - Cassette type Indoor unit.
Erection of 2.0 TR Ceiling suspended - Cassette type - Indoor unit
Supply of 2.5 TR, Ceiling suspended - Cassette type Indoor unit.
Erection of 2.5 TR Ceiling suspended - Cassette type - Indoor unit
Supply of 3.0 TR, Ceiling suspended - Cassette type Indoor unit.
Erection of 3.0 TR Ceiling suspended - Cassette type - Indoor unit
Supply of 4.0 TR, Ceiling suspended - Cassette type Indoor unit.
Erection of 4.0 TR Ceiling suspended - Cassette type - Indoor unit
Supply of 5.0 TR, Ceiling suspended - Cassette type Indoor unit.
Erection of 5.0 TR, Ceiling suspended - Cassette type Indoor unit.
VRF Multi Kits / Refnet joints - for Outdoor Units: Supply & installation , testing , commissioning of multi connection Joint / Ref Net for double ODU connections at - Outdoor Units . It should be complete as per the technical specifications compatable for VRF/VRF System ..
Supply
Erection
VRF Multi Kits / Refnet joints - for INDOOR UNITS : Supply & installation , testing , commissioning of Imported Y/T refnet joints with insulation to connect indoor units with main header as per the approved drawing. It should be complete as per the technical specifications compatable for VRF/VRF System . 1 set will comprise of 2 Y/T Refnet joints each for suction & discharge lines
Supply
Erection
REFRIGERANT COPPER PIPING : Supply, installation, testing and commissioning including Pressure testing , vacuum & commissioning of the refrigerant copper piping soft/ hard drwan copper piping for VRF/VRV systems connected between IDU & ODU of different sizes as below . Complete refrigerant copper piping work with fittings ,with suitable adjustable ring type hanger supports, jointing / brazing including accessories , insulated with XLPE Class-O tubular insulation / with Class O Closed cell elastometric nitrile rubber sleeves sections of specified thickness as given below for Suction and Liquid lines , all the acessories as per specifications as required. Party has to submit the OEM certificate stating that copper piping is manufactured for VRF/VRV systems. Refrigerant copper piping sizes, quality & wall thickness as per the OEM recommendations of VRF/VRV - AC System. Entire refrigerant coppe piping from IDU(s) to ODU(s) should be rapped with GI perforated sheet to avoid rat bite.
Supply - 6.40 mm (1/4") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection- 6.40 mm (1/4") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply - 9.52 mm (3/8") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection - 9.52 mm (3/8") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply - 12.7 mm (1/2") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection - 12.7 mm (1/2") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply - 15.90 mm (5/8") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection- 15.90 mm (5/8") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply -19.10 mm (3/4") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection -19.10 mm (3/4") dia (OD) - Soft drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply -22.20 mm (7/8") dia (OD) - Hard drawn with tube thickness 1.2 mm with 19 mm thick insulation
Erection -22.20 mm (7/8") dia (OD) - Hard drawn with tube thickness 1.2 mm with 19 mm thick insulation
Supply -25.4 mm (1") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection -25.4 mm (1") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply -28.60 mm (1 1/8") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection -28.60 mm (1 1/8") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply -31.8 mm (1 1/4") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection-31.8 mm (1 1/4") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply-35.40 mm (1 1/2") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection-35.40 mm (1 1/2") dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Supply-41.30 mm dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
Erection -41.30 mm dia (OD) - Hard drawn copper with tube thickness 1.2 mm with 19 mm thick insulation
UPVC Piping: Supplying and fixing of following sizes of ISI marked, rigid UPVC piping for condensate water disposal with suitable support along with accessories & insulated with 9 mm thick closed cell elastomeric nitrile rubber as required for Indoor Units
Supply - 25 mm OD
Eretion - 25 mm OD
Supply -32 mm OD
Erection-32 mm OD
Supply-40 mm OD
Erection-40 mm OD
CONTROL CABLES: Supply & Laying of control transmission cabling cum control wiring with following sizes of FRLS PVC insulated, PVC sheathed copper conductor in PVC pipe with fittings , clamps, including making connections etc. as reqd.for Indoor Unit (IDU) to Outdoor Unit (ODU) including making end termination with brass compression gland and copper lugs.
Supply - 3 core x 1.00 sq.mm
Erection - 3 core x 1.00 sq.mm
Supply - 3 core x 1.50 sq.mm
Erection - 3 core x 1.50 sq.mm
POWER CABLES: Supply & Laying of power cable from MCC to ODUs with following sizes of FRLS PVC insulated copper conductor aromored in PVC pipe with fittings , clamps, etc. including making connections etc. as reqd.from MCC Panel to Outdoor Units (ODU) including making end termination with brass compression gland and copper lugs.
Supply - 4 Core X 16.0 Sq.mm
Erection - 4 Core X 16.0 Sq.mm
Supply - 4 Core X 35.0 Sq.mm
Erection - 4 Core X 35.0 Sq.mm
CABLE TRAYS: Supply & Installation of following size of perforated Hot Dipped Galvanised Iron Cable tray & GI Cover ( Galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in conveinet sections, joined with connectors, suspeneded from the ceiling with GI suspenders including GI bolts & nuts , / MS supports, etc. as required at site.
Supply-150 mm widith X 75 mm depth X 1.6 mm thickness
Erection-150 mm widith X 75 mm depth X 1.6 mm thickness
Supply-200 mm width X 75 mm depth X 1.6 mm thickness
Erection-200 mm width X 75 mm depth X 1.6 mm thickness
Supply-300 mm width X 75 mm depth X 1.6 mm thickness
Erection-300 mm width X 75 mm depth X 1.6 mm thickness
Supply-450 mm width X 75 mm depth X 1.6 mm thickness
Erection-450 mm width X 75 mm depth X 1.6 mm thickness
Supply-600 mm width X 75 mm depth X 1.6 mm thickness
Erection-600 mm width X 75 mm depth X 1.6 mm thickness
SITC of 25 mm thick Class "O" Closed cell nitrile rubber insulation for UNDER DECK THERMAL INSULATION for exposed roof. Slab to cleaned and adhesive shall be applied on the roof and on the insulatilon . Insulation shall be stuck to roof firmly. Flat clamps, L clamps, etc. sall be used at the edges corners, etc. to ensure the insulation firmly stuck to roof. GI Clampings shall be fixed to the room with screws. Necessary clamping shall be used neaer the conduits , other services , etc. to ensure the insulation is firmly fixed to the slab. ( EPS , 18 Kg density TF quality).
Supply
Erection
Supplying, installation, testing and commissioning of floor mounted cubical type Outdoor ( All weather proof) - Application electrical power supply panel - with double door system - IP 65 protection- (On suitable foundation to withstand a wind speed of 160 KMPH -) suitable for 415V, 3 Phase, 4 Wire, 50 Hz AC supply system fabricated in compartmentalized design CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process, powder coating in approved shade, having 500Amps capacity 4 strip bus bars of high conductivity, entire panel shall have a common GI earth bar of size 25 mm x 5 mm. Digital type Multifunction meter for measuring Frequency, Voltage, Current and Power Factor, KW, KWH with CTs. Phase indication LED lamps with 2 Amp SPMCBs 10 KA Breaking capacities, as per standard practice, as required. -1 Set. Incomer 500 Amps four pole, 35KA breaking capacity (Ics) MCCB, thermal magnetic release type with earth fault protection, rotary handle - 1 Nos. OUT GOINGs : - 63 Amps four pole, 25KA breaking capacity (Ics) MCCB, thermal magnetic release type with rotary handle - 08 Nos. NOTE: MCC Panel shall be installed near to ODU location ( i.e. Terrace of bldg)
Supply - MCC Panel
Erection - MCC Panel
EARTHING SYSTEM:Supply & laying of GI Earth strip for connecting Electrical panels , ODU's atc. as per site requirement
Supply - 25 mm x 3 mm thick ( one inch flat)
Erection - 25 mm x 3 mm thick ( one inch flat)
Supply - Single core - Green PVC Insulated 2.5 Sq.mm wire
Erection - Single core - Green PVC Insulated 2.5 Sq.mm wire
STRUCTURAL FABRICATED STEEL WORK: Supply, Fabrication , Cutting, Welding , Erection at site and painting of M. S. Angle structural steel work for required truss, AC /Supporting structurer/etc. & as per site requirements, etc. based on the approved drawings. The work should be carried out as per good manufacturing and installation practices in concurrence with approved drawings. The structural steel materials should confirm to IS : 2062 (latest version) as per drawings. All welding electrodes to confirm to relevant IS codes. Fabrication and erection of the structural steel works shall be as per IS: 800 and welding work as per IS:816 and IS: 822. Finally all steel work to be painted with one coat of zinc chromate primer and two coats of synthetic enamel paint.
Supply
Erection
Charging of suitable eco-friedly Refrigerant / as per OEM recommended refrigerant in VRF/VRV Systems
Supply
Comprehensive AMC of Complete VRF/VRV System of New Computer Bldg. Comprehensive maintenance of ( Routine & Preventive ) and breakdwon of high side and lowe side of the VRF/VRV -144 HP Capacity Air Conditioning system comprising all the machinery - IDU's ; ODU's , remotes, electrical MCC panel, equipments including spares , consumables , etc. as given in additional terms and conditions complete as required (after One year defect liability period / after warrantee period .)
First Year / HP
Second Year /HP
Removal of existing GI ducting & closing the openings with suitable GI duct with necessary fittings, etc. and safe disposal at Stores with necessary transporatation.
TOOT MNE TECH Private Limited
BLUE STAR LTD
ETA Engineering Pvt Ltd
BRITE INDUSTRIES
Utility Services
AIR CONTROL ENGINEERS
INTEGREATED COOLTECH PVT LTD
stage.html
html • 0.03 MB
finance_806389.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .