Loading…
Loading…
Tender Value
₹8.2 Cr
EMD Value
₹16.4 L
Closing Date
5 Aug 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SNT TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where, V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar Nature of Work: Any interlocking work related to LC gate like interlocking, provision of ELB, Provision of sliding boom, Approach warning etc.
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Checklist for Tenderer: The Tenderer shall submit signed copy of Check-list placed in documents attached with tender. The Tenderer shall also submit relevant documents of compliance of the checklist if any.
I/We have read the tender notice (NIT)detail, schedule of material and works and Tender document along with all the conditions attached/referred to, in this tender document and agree to abide by the said conditions.
It is certified that i am the authorized person to represent the firm and I am authorized to sign the tender and all the document on behalf of the firm.
I/We hereby agree to abide by the Indian Railway Standard General Condition of contract (GCC) with all correction slip up to date and to carry out the work according to the special conditions of contract and specification of material and works as laid down by Railway as mentioned in the tender document.
Bhavnagar Division: Supply, installation, testing & commissioning of Signalling Gears/materials in connection of Interlocking of 21 Nos LC gates against sanctioned work of Interlocking of LC gates having ATVU more than 10000 (47 Nos).
DRMSnT-BVP-Sig14R1of26-27
DRMSnT-BVP-Sig14R1of26-27
Open
Works - General
15 Months
Bhavnagar, Gujarat
₹0
₹16.4 L
5 Aug 2026
14 Jul 2026
22 Jul 2026
204 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,53,91,240.51 | ||
| — | 12.00 | — | — | ||
| Electrically Operated Lifting Barrier complete set suitable for 24V DC supply with motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 Ver - 2 with latest amendment. One set consisting 02 Nos of Barriers of length 09.76 Mtrs. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 Ver - 2 clause 10.1 & 10.2. | — | — | — | 57,39,948.6 | |
| — | 21.00 | — | — | ||
| LED type control-cum indication panel complete with prewired Tag- Blocks, Wires MS angles etc. for LC gate, depicting the yard layout Signal, Point, Track circuit, Operating/ emergency Push Button, counter with sealing arrangements, house in a Steel metal cabinet. This shall be consist 15 x 10 exchangeable Domino Unit as per Spec. SPN/186/2004 ver. 1 or latest amendment. Or as per instruction of Engg -in charge. | — | — | — | 13,99,289.01 | |
| — | 80.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3). | — | — | — | 4,78,476.8 | |
| — | 5.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm. (85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 1,66,831.05 | |
| — | 5.00 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm). 101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 6,80,317.75 | |
| — | 500.00 | — | — | ||
| DC neutral line relay QNA1K (QSA3), AC immune, DC neutral line 24V, 12F/4B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS930A, (as applicable) IRS: S34& IRS: S23 or latest. | — | — | — | 29,60,935 | |
| — | 252.00 | — | — | ||
| Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable). | — | — | — | 15,02,920.44 | |
| — | 21.00 | — | — | ||
| Fail safe electronic time delay device mounted on Q series relay base & covered with fixed timing of 60/120/180/240seconds as specified by purchaser conforming to IRS.S. 61-2000 or latest. | — | — | — | 1,22,245.83 | |
| — | 400.00 | — | — | ||
| D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest Quantity break up of each type of fuse block will be specified by Engineer in-charge. | — | — | — | 12,772 | |
| — | 500.00 | — | — | ||
| D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS: S-80/92 or latest. Quantity breakup of each type of fuse block will be specified by Engineer in- charge. | — | — | — | 17,430 | |
| — | 840.00 | — | — | ||
| Indicative type Fuse base/holder with cap, suitable to G type fuse of capacity 0.63A -3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 47,880 | |
| — | 840.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 17,488.8 | |
| — | 21.00 | — | — | ||
| Tag block 200 way/160way with PVC covers asper (IRS: S-77/2006(Rev.1) or latest &Drg.no.SA- 24751 & 52. Requirement of each type shall be specified by Engineer-in-charge. Note: In case ABB type relays proposed to be used with100 way block then Two100 way Tag Block will be consider as one 200 way Tag Block. | — | — | — | 57,544.2 | |
| — | 42.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC Immunized with different ward combinations (Three ward plates to be supplied with each relay). | — | — | — | 3,47,072.88 | |
| — | 21.00 | — | — | ||
| Earth Leakage Detector asper RDSO / SPN / 256 /2002 with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and- 10% tolerance. | — | — | — | 31,64,869.47 | |
| — | 1050.00 | — | — | ||
| Rubber Mat for Power Equipment room. (5mm thick) As per instruction of Engg-in Charge. | — | — | — | 1,44,217.5 | |
| — | 63.00 | — | — | ||
| Fire Extinguisher CO2 type (capacity 4.5 kg.). | — | — | — | 4,77,505.98 | |
| — | 1050.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 1,18,723.5 | |
| — | 1050.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 2,78,334 | |
| — | 126.00 | — | — | ||
| Colour Light Signal Complete. This includes: - Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance).CI Base (As per IRS S-10& RDSO Drg. No. 2011/M with latest assembly). Pinnacle. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. Signal Front Staging Complete Assembly for CLS Unit. Signal back staging as per extent WR Practice. Note: Height of the Post shall be 5.5 Long. | — | — | — | 15,49,026.36 | |
| — | 42.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 13,47,890.46 | |
| — | 84.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSODRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006(Vol. 1.0) or latest and FRP material as per RDSO Spec. No. RDSO/SPN/151/1997 or latest. | — | — | — | 25,71,228.24 | |
| — | 63.00 | — | — | ||
| Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die, & 103.5 mm inner dia. One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | — | — | — | 1,29,064.95 | |
| — | 126.00 | — | — | ||
| Medium Class G.I. Pipes to IS: 1239 (Pt.I)-2004or latest; 100mm dia. (int. dia) minimum 3.65mmthick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | — | — | — | 82,599.3 | |
| — | 21.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 12,56,975.58 | |
| — | 105.00 | — | — | ||
| SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 54,59,796.3 | |
| — | 126.00 | — | — | ||
| — | — | — | 6,67,157.4 | ||
| — | 63.00 | — | — | ||
| — | — | — | 5,91,637.41 | ||
| — | 105.00 | — | — | ||
| — | — | — | 2,29,572 | ||
| — | 21.00 | — | — | ||
| — | — | — | 55,775.37 | ||
| — | 21.00 | — | — | ||
| — | — | — | 1,71,954.3 | ||
| — | 21.00 | — | — | ||
| — | — | — | 3,37,103.34 | ||
| — | 10.00 | — | — | ||
| — | — | — | 3,65,000 | ||
| — | 10.00 | — | — | ||
| — | — | — | 3,65,000 | ||
| — | 10.00 | — | — | ||
| — | — | — | 1,30,000 | ||
| — | 10.00 | — | — | ||
| Rx coil (Web Mounting Type) for HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3 or latest. CEL Make. | — | — | — | 1,30,000 | |
| — | 5.00 | — | — | ||
| FLUKE Hand held 100KHz Digital Multi meter (Fluke 117 True RMS multi meter). Prior approval to be taken before supply. | — | — | — | 83,325 | |
| — | 21.00 | — | — | ||
| Motorised locking unit for 24V DC EOLB. Prior approval to be taken from Railway before supply. | — | — | — | 8,95,312.11 | |
| — | 105.00 | — | — | ||
| LIMIT SWITCH. Prior approval to be taken from Railway before supply. | — | — | — | 1,69,174.95 | |
| — | 5.00 | — | — | ||
| Gate Motor. Prior approval to be taken from Railway before supply. | — | — | — | 53,292.4 | |
| — | 21.00 | — | — | ||
| TIMIMG BELT. Prior approval to be taken from Railway before supply. | — | — | — | 17,544.24 | |
| — | 21.00 | — | — | ||
| CONTACTOR UNIT (24V/9 Amp). Prior approval to be taken from Railway before supply. | — | — | — | 35,088.27 | |
| — | 42.00 | — | — | ||
| G.I octagonal boom 32 fit long of G.I Material to be procured suitable to Electrical lifting barrier as per RDSO Specification No. RDSO/SPN/208/2012 Ver.2.0 or latest as per Drg.No. RDSO/S11600 of G.I Boom. Prior approval to be taken before supply. | — | — | — | 5,70,240.72 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TENDERCONDITIONANDSCHEDULEOFWORK21LCgatesFINAL.pdf
ATTACHMENT
GCCACS11Merged_compressed.pdf
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf JPO Digging
ATTACHMENT
CHECKLISTFORTENDERERmorethan50Lacs.pdf
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].