REPAIR TO INTERNAL WIRING AND FITTINGS OF OTM AND MD ACCN UNDER GE EAST BAREILLY
2020_MES_361159_2
C/8844/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST BAREILLY
₹50,000
Yes
13 Oct 2020
26 Aug 2020
21 Sept 2020
26 Aug 2020
19 Sept 2020
7 Sept 2020
26 Aug 2020 - 2 Sept 2020
Amount
Taking down copper/aluminum point wiring (Light fan, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting holders etc, removing materials for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of wall, floors etc complete all as specified and directed.
Taking down electric meter and disconnecting, removing to store for keeping in safe custody for refixing etc complete all as specified and directed.
Taking dowm submainwiring/service cable including earth wire and making good disturbed surfaces to match with the existing surfaces of walls incuding removing of site complete all as specified and directed.
Taking down ceiling/exhaust fan and disconnecting, removing to store for keeping in safe custody for rehanging etc complete all as specified and directed.
Taking down & disconnecting Water Heater storage type( Geyser ) and removing to store for keeping in safe custody in MES store for re-install complete all as specified and directed.
Taking down Light fittings removing to store for keeping in safe custody for refixing of serviceable & UNSV for credit as per conditions) etc complete all as specified and directed.
Taking down main switch / MCB/ DBS including MCC Bs etc of any size removing for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of wall, floors etc complete all as specified and directed
M & L for point wiring with 1.5 sqmm cable PVC unsheathed and insulated copper multistranded conductor FRLS 1100 Volts grade cable ( red colour cable to be used for live connection and black colour cable to be used for neutral connection ) controlled by one way switch drown through and including non metallic rigid PVC concealed conduit with all accessories and 1.5 sqmm copper multistrand conductor FRLS 1100 Volts grade unsheathed PVC insulated ( green colour ) continuity earth wire connected to common earth dolly and sunk cast pressed steel terminal box made out of MS sheet 1.25 mm thick for mounting of fittings like switch , socket and fan regulator with 3 mm thick hylum laminated sheet cover incl cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth complete all as specified and as directed for one light/fan/exhaust fan/bell point controlled by one switch/bell push complete all as specified and directed
all as per item no 8 here in before but One 3 pin socket oultel 5 Amp on the same board with other switch complete all as specified and directed
-Ditto - all as per item no 8 here in before but One 3 pin socket outlet 5 Amp independent complete all as specified and directed
Ditto -all as per item no 8 here in before One 3 pin socket outlet 15 Amps independent with 2.5 Sqmm PVC insulated sheathed cable and 2.5Sqmm cable for earth wire complete all as specified and directed
Ditto All as per item no.8 here in before but wiring with MS boxes / non metallic rigid PVC Terminal boxes of suitable size and non metallic rigid PVC casing & caping double lock system with all accessories for one light/fan/exhaust fan/bell point controlled by one switch/bell push complete all as specified and directed
All as per above item no 12 here in before but One 3 ;pin socket oultel 5 Amp on the same board with other switch complete all as specified and directed
All as per above item no 12 here in before but One 3 pin socket outlet 5 Amp independent complete all as specified and directed
All as per above item no 12 here in before but One light point controlled by two way switch complete all as specified and directed
All as per above item no 12 here in before but One 3 pin socket outlet 15 Amp independent with 2.5 Sqmm PVC insulated sheathed cable and 2.5Sqmm cable for earth wire complete all as specified and directed
All as per item no.8 here in before but wiring in existing conduit for one light/fan/exhaust fan/bell point controlled by one switch/bell push complete all as specified and directed
All as per item No 17 here in before but One 3 pin socket outlet 5 Amp independent complete all as specified and directed
All as per item No 17 here in before but One 3 pin socket outlet 15 Amp independent with 2.5 Sqmm PVC insulated sheathed cable and 2.5Sqmm cable for earth wire complete all as specified and directed
S&F switch piano flush type single pole one way 5 Amps complete all as specified and directed
S&F in repairs switch piano flush type single pole one way 5 Amps complete all as specified and directed
S&F in repairs Modular switch one way 6 Amp, one module complete all as specified and directed
S&F switch piano flush type single pole two way 5 Amp complete all as specified and directed
S&F in repairs switch piano flush type single pole two way 5 Amp complete all as specified and directed
S&F Switch Piano flush type single pole one way 15 Amps complete all as specified and directed
S&F in repairs Switch Piano flush type single pole one way 15 Amps complete all as specified and directed
S&F in repairs Modular Switch one way 16 Amp, one module complete all as specified and directed
S&F Bell push flush type 5 Amp complete all as specified and directed
S&F in repairs Bell push flush type 5 Amp complete all as specified and directed.
S&F in repairs Modular Bell push 6 Amp, one module complete all as specified and directed
S&F Socket outlet 2 in 1, 3 pin 5 Amp flush type complete all as specified and directed
S&F in repairs Socket outlet 2 in 1, 3 pin 5 Amp flush type complete all as specified and directed
S&F in repairs Modular Socket 6 Amp, 2 / 3 pin combined 2 module complete all as specified and directed
S&F socket outlet 2 in 1, 3 pin 5Amp and 15 Amp complete all as specified and directed
S&F in repairs socket outlet 2 in 1, 3 pin 5Amp and 15 Amp complete all as specified and directed
S&F in repairs Modular socket 6A/16A, 2/3 pin combined 2 module complete all as specified and directed
S&F in repais switch Socket combination 2 in 1, 5 Amp flush type complete all as specified and directed
S&F in repais switch Socket combination 5 in 1, 5 A/15 A flush type complete all as specified and directed
S&F Bell AC 230 Volt single pole Ding Dong complete all as specified and directed
S&F in repair Bell AC 230 Volt single pole Ding Dong.complete all as specified and directed
S&F Lamp holder ( batten/angle ) PVC/Polycarbonate type with back plate for batten/angle fittings complete all as specified and directed
S&F in repairs Lamp holder (batten/angle) PVC/Polycarbonate type with back plate for batten/angle fittings complete all as specified and directed
S&F in repairs Modular fancey Lamp holder, PVC/Polycarbonate type with back plate for batten/angle fittings complete all as specified and directed
Fixing only Lamp LED 7/9 Watt 230 Volt issued under Schedule ' B ' stores free for fixing.
Fixing only old serviceable light fittings any type received from item no-6 above including electric connection & cleaning complete all as specified and directed
Fixing only old serviceable LED Tube light fittings 18/20 Watt, 4' complete received from item Nos.-6 above including cleaning & connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified and directed
Fixing only in repairs LED Tube light fittings 18/20 Watt, 4' complete along with retrofit tube Lamp issued under Schedule 'B' stores including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified and directed
Fixing only in repairs LED Tube light fittings 9/10 Watt, 2' complete along with retrofit tube lamp issued under Schedule 'B' stores including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified and directed
Fixing only in repairs LED retrofit tubes only 18/ 20 Watt,4' issued under Schedule 'B' stores free for fixing.
Fixing only in repairs LED retrofit tubes only 9/ 10 Watt, 2' long issued under Schedule 'B' stores free for fixing complete all as specified and directed
S&F ceiling rose, 3 terminals, PVC polycarbonate isolated body complete all as specified and directed
S&F in repairs ceiling rose, 3 terminals, PVC polycarbonate isolated body complete all as specified and directed
S&F in repairs LED bulk head luminaire 12 watt with Engineering plastic housing and oval shaped clear prismatic diffuser, heat sink integrated including one no. 12Watt LED lamp complete all as specified and directed
. S & F in repairs LED Ceiling light 12Watt round surface mounted die cast aluminium housing with frosted diffuser including LED lamp 12 Watt complete all as specified and directed
S &F Recess mounting LED ultra slim Ceiling light 1'X2', 24 Watt complete all as specified and directed complete all as specified and directed
S & F in repairs LED Wall light fitting laltern made up of polycarbonate suitable for LED 9 Watt, B-22 base holder including connection with necessary accessories complete all as specified and directed. Make: Havells Cat No. LHDIO2160099 or equivalent of Philips/ CG as a[pproved by GE.
.S & F in repairs LED Wall bracket type CITY-2 fitting 9 Watt complete..Make: C&S/Havells/Bajaj/Phillips / Crompton as approved by GE.
S & F in repairs LED recessed mounting LED down lighter 1x10 Watt with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency with in built electronic driver, suitable for ceiling including LED driver and all accessories complete all as specified and directed. Make Havells, Cat No. INTEGRANEOSURFACDLS10WLED840S or equivalent make of Philips/CG as approved by GE.
S & F in repairs 36 watt PL-L/CFL lamp 4 pins for 60cmx60cm ceiling light fitting complete all as specified and directed
S&F in repairs stepped, (socket/switch type) electronic fan regulator flush type, 180 Watt, 240 Volts complete all as specified and directed
Hanging only ceiling fan after cleaning, and remarking the serial MES fan nos etc complete including electric connection with three core flexible PVC insulated copper conductor multistranded white in clour 1.0sqmm cable (Item received form ser No 4) complete all as specified and directed
Fixing only Exhaust fan, cleaning all dust etc from surfaces of any size and remarking the serial MES fan nos. etc complete including electric connection with three core flexible PVC insulated copper conductor multistranded white in colour 1.0 sqmm cable ( Item received from srl no-4 ) complete all as specified and directed
Install only Water heater storage type, electric, capacity 25 litres complete accessories 230V received from Item Sl No 5 including Hot & cold water supply connection and fixing with nuts, bolts & washers and electric connection also complete all as specified and directed
Fixing only and connecting electric meter upto 25 Amp received from item srl no-2 complete all as specified and directed
M & L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in & including PVC conduit complete all as specified and directed
. All as per item No 65 here in before but in & including casing and caping complete all as specified and directed
. M & L in repairs for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through in & including PVC conduit complete all as specified and directed
All as per item No 67 here in before but in & including casing and caping complete all as specified and directed
. M & L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn in existing conduit complete all as specified and directed
M & L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn in existing conduit complete all as specified and directed
. M & L in repairs sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn in existing conduit complete all as specified and directed
M & L in repairs on surfaces for Rigid non metallic PVC conduit, ISI marked, medium grade, including all fittings such as tees, bends, junction boxes, elbows, reducers,bell mouth tube ends, couplers, saddles, pipe hooks, lock nuts etc of size 25 mm dia ( external) and making good disturbed surfaces complete all as specified and directed.
. M & L in repairs on surface for non metallic rigid PVC casing & caping ISI marked, medium grade not less than 25mm base size double lock system including all fittings such as tees, bends, junction boxes, elbows, saddles, lock nuts etc and making good disturbed surfaces complete all as specified and directed.
M & L in repairs Junction boxes ( 1 to 4 way) with suitable screws of size 25mm dia complete all as specified and directed.
.S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 100 X 100 X 50 mm deep complete, ISI marked complete all as specified and directed
.S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 175 X 100 X 50 mm deep complete, ISI marked complete all as specified and directed
S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 200 X 150 X 50 mm deep complete. ISI marked.
.S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 250 X 200 X 50 mm deep complete. ISI marked complete all as specified and directed
.S & F in repairs of PVC rectangular block for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of size 350 X 300 X 50 mm deep complete. ISI marked complete all as specified and directed
S & F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 300 x 250 mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified.Make- Hylem ISI marked complete all as specified and directed
S & F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 250 x 200 mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified.Make- Hylem ISI marked complete all as specified and directed
S & F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 200 x 150 mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified.Make- Hylem ISI mrked complete all as specified and directed
S & F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 150x 100mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified.Make- Hylem ISI marked complete all as specified and directed
S & F in repairs of 2.8mm thick rectangular plastic laminated sheet cover of size 100 x 100 mm including cutting holes for mounting switches, sockets, fan regulators etc as pre requirement including fixing with sufficient no. of machine screws & washers complete all as specified.Make- Hylem ISI mrked complete all as specified and directed
.S & F in repairs of Cast Iron/Pressed steel terminal rectangular sunken boxes for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of Hylem, ISI make size 300 X 250 X 60 mm deep complete all as specified and directed.
S & F in repairs of Cast Iron/Pressed steel terminal rectangular sunken boxes for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of Hylem, ISI make size 250 X 200 X 60 mm deep complete all as specified and directed.
.S & F in repairs of Cast Iron/Pressed steel terminal rectangular sunken boxes for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of Hylem, ISI make size 200 X 150 X 60 mm deep complete all as specified and directed.
.S & F inrepairs of Cast Iron/Pressed steel terminal rectangular sunken boxes for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of Hylem, ISI make size 150 X 150 X 60 mm deep complete all as specified and directed.
.S & F in repairs of Cast Iron/Pressed steel terminal rectangular sunken boxes for mounting switches, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover of Hylem, ISI make size 100 X 100 X 60 mm deep complete all as specified and directed.
S&F in repairs single pole and neutral enclouser having IP -67 protection with a three pin & earth plug with socket complete and one SPN, 20 A , 240 V MCB complete all as specified and directed complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 2 way, 240 Volts single door single pole & neutral without bus bar complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts double door single pole & neutral with 200 Amps rated bus bar complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 8 way, 240 Volt, double door single pole & neutral with 200 Amps rated bus bar complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 12 way, 240 V, double door single pole & neutral with 200 Amps rated bus bar complete all as specified and directed
S&F in repairs sheet metal enclousers (DBS) when MCBs to be used 4 way, 415V, double door tripple pole & neutral with 200 Amps rated bus bar complete all as specified and directed
S&F in repairs MCB 415V, 10KA, TPN , 100Amp complete all as specified and directed complete all as specified and directed
S&F in repairs MCCB 415V, 16KA, 4 Pole , 100Amp complete all as specified and directed complete all as specified and directed
S&F in repairs MCB single phase and neutral 16A-32A, 230V 10KA. B' curve type complete all as specified and directed complete all as specified and directed
S&F in repairs MCB SP 6A-32A, 230V. 10KA. B' curve type complete all as specified and directed
S & F in repairs weather proof flat twin core Cable with aluminium conductor multi stranded of size 6 sqmm, 1100Volts grade complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts,check nuts, nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-I 2009. GI wire protected by GI pipe light grade 15mm dia connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, earthing pit in PCC (1:3:6) type C1,RCC (1:2:4) type B1 precast cover slab with one handle made out of 8 mm dia round bar,20 mm dia (medium grade) watering pipe and providing layer of charcoal or coke and salt in alternative layers complete as specified or directed & including testng on completion complete all as specified and directed.
N S ELECTRICALS
URBANS CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .