Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹19.5 L+₹75,525 (4.02%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹41,680
Closing Date
4 Nov 2020, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
REPAIR / REPLACEMENT OF STREET LIGHT, EARTHING FOR STREET LIGHT POLES, HT/LT UG CABLE, SERVICE CONNECTION, AT BANBASA UNDER GE PITHORAGARH
2020_MES_381425_1
CA No CWE/HILLS/PGH/47 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Works
180 days
PITHORAGARH
CLASS E
11 documents required · 11 mandatory
₹500
Yes
GE PITHORAGARH
₹41,680
Yes
6 Jan 2021
28 Sept 2020
6 Nov 2020
29 Sept 2020
4 Nov 2020
19 Oct 2020
30 Sept 2020 - 14 Oct 2020
Amount
Supplying, drawing and fixing of continuous GI earth wire /guard /cradles of 4mm dia with and including GI binding wire of 1.63 mm dia & GI holding hook on HT poles including taking down old unserviceable GI wire, complete all as specified and directed.
S&F ACSR conductor in replacement of any type and size stretching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between spans etc complete all as specified and directed Note:- For measurement purpose horizontal distance between centre to centre of two adjacent poles be measured and 3% be added for sag, jointing jumpers etc.
S&F in replacement, indoor type cable terminating jointing kit (Heat shrinkable type) complete with jointing material and accessories, suitable for 3 core 11000 volts grade HT XLPE underground cable size 50 sqmm to 95 sqmm 3 core including testing after jointing, complete all as specified and directed. Note:- Kit shall not be older than 3 months from its date of manufacturing
S&F in replacement, outdoor type cable terminating jointing kit (Heat shrinkable type) complete with jointing material and accessories suitable for mounting on channel / angle iron with and including cable peice of suitable length & size, suitable for 3 core 11000 volts grade HT XLPE underground cable size 50 sqmm to 95 sqmm 3 core including testing after jointing, complete all as specified and directed. Note:- Kit shall not be older than 3 months from its date of manufacturing
S&F in replacement, outdoor type cable jointing kit straight through type (Heat shrinkable type) complete with jointing material and accessories suitable for mounting on channel / angle iron with and including cable peice of suitable length & size, suitable for 3 core 11000 volts grade HT XLPE underground cable size 50 sqmm to 95 sqmm 3 core including testing after jointing, complete all as specified and directed. Note:- Kit shall not be older than 3 months from its date of manufacturing
S&F insulator, pin type, porcelain, vitreous, white, brown or green 100mm height and 65mm dia including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut for conductor working pressure 1100 volts grade including dismantling of old unserviceable insulator complete all as specified and directed
M&L for pin type porcelain, vitreous brown insulator including one galvanished mild steel spindle, two galvanized mild steel washers and one nut, 150 mm height and 150 mm dia for 11000 volt grade, including dismantling of old unserviceable insulator, complete all as specified and directed
M&L for disc type insulator porcelain, vitreous 145 mm high and 225 mm dia hole and socket white brown or green sinlge Disc assembly for tension with tension clamps for conductor working pressure 11000 V (11 KV), including dismantling of old unserviceable insulator, complete all as specified and directed
M&L shackle type porcelain vitreous, white brown or green insulator including galvanized mild steel strap 31 x 3 mm including galvanized mild, steel bolts 14 mm dia washers and nuts, 75mm height and 90 mm dia for 1100 volts grade including dismantling of old unserviceable insulators, complete all as specified and directed
S&F in repairs post insulator 254 mm high and 210 mm dia with four bolts, nuts and washers suitable for 11 KV, complete all as specified and directed.
S&F in repairs MCCB 63 Amps, AC 415 volts, 4 pole, having 16 KA breaking capacity, with adjustable load setting including making connection, complete all as specified and directed.
S&F in repairs MCCB 100 Amps, AC 415 volts, 4 pole, having 16 KA breaking capacity, with adjustable load setting including making connection, complete all as specified and directed.
S&F in repairs MCCB 125 Amps, AC 415 volts, 4 pole, having 16 KA breaking capacity, with adjustable load setting including making connection, complete all as specified and directed.
S&F in repairs MCCB 200 Amps, AC 415 volts, 4 pole, having 36 KA breaking capacity, with adjustable load setting including making connection, complete all as specified and directed.
S&F in repairs MCCB 400 Amps, AC 415 volts, 4 pole, having 36 KA breaking capacity, with adjustable load setting including making connection, complete all as specified and directed.
Supply and replacing / topping up of transformer oil with new transformer oil (ISI Marked) duly centrifuged and tested for dielectric strength not below from 45 to 60 KV in transformer complete all as specified and directed
Dehydration, centrifuging, filtration, cleaning and drying the wetness of transformer oil to bring the electric strength as required in transformer outdoor / indoor type 11/433 KV located at different locations at Banbasa Mil Camp area, by Dehydration plant having minimum capacity 60 litre per hour including testing of oil before and after dehydration / filtration for each equipment for satisfaction performance complete all as directed
S&F in replacement of 11 KV grade, lightening arresters expulsion type complete (Set of Three) with all fittings, transmission class, discharge capacity 65KA, complete all as specified and directed.
Supplying, fabricating, fixing in position cross arms, bracings, supports, clamps and back plates, fabricated from in structural steel section any type /size /shape including nuts bolts washers, welding, bending hot or cold, drilling holes for bolts, in any shape or size as required at site, including painting with two coats aluminium paint over a coat of red oxide including dismantling of old unserviceable existing cross arms complete all as specified and directed.
S&F in replacement of air break heavy duty gang operated, triple pole mechanically operated, mounted on HT insulators and galvanised steel frame with operating rod of 25mm bore GI pipe (Medium grade) suitable for operating mechanism working from ground level for current rating 200 Amps , suitable for 11 KV, 50 Hz supply with and including 12 Nos. Insulators and drop out fuse carrier element, complete all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for laying under ground cable, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick, complete all as specified and directed.
Removing excavated materials (Soil) n. exc. 50m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified.
M & L for laying of dry, clean fine sand as in cushion or filling in trenches around underground cable, in ducts, inside sub station complete all as specified and directed.
Supply & laying of sub class ‘B’ old size bricks, laid flat i.e length of brick shall be laid across the length of cable for protection of underground cable, gap between adjacent brick not more than 10mm, complete all as specified and directed.
Supply and fixing steel tubular electric pole, swaged type, welded type, 410 SP-31 (09 meter long) complete with CI base plate, pole cap, bolts, nuts & screws all as specified including the following and including dismantling of old existing unserviceable steel tubular electric pole:- (i) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in hard / dense soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (ii) M&L for providing PCC 1:4:8, type D-2 ( using 40 mm graded stone aggregate) in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (iii) M&L for providing PCC 1:3:6, type C2 ( using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (iv) M&L for providing PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia or as directed by EIC complete all as directed and as specified. (v) M&L for painting of pole externally with two coats of black bituminous paint up to planting depth. The remaining portion of exterior shall be painted with one coat of red oxide primer and above plinth block/ concrete collar with two coats of aluminium paint including preparation of surfaces including painting of 30 cm wide black and yellow bands (strips) 5 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and writting pole number and feeder location by white synthetic enamel paint with proper letter size as directed.
Supply & fix in repairs 3 line spacer suitable for overhead conductor, complete all as specified and directed.
Supply & fix in repairs 4 line spacer suitable for overhead conductor, complete all as specified and directed.
M&L Stay assembly as in repairs for HT steel tubular poles comprising of 7/4 mm Galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (Grade 2 quality) fixed to pole with FI clamps 50x6 mm size, bolts, nuts, washers, galvanised steel stay rod 20 mm dia and 2150 mm long, stay bow 400x14 mm, nuts, bolts, washers, galvanised steel plate 300 x300 x 6 mm size and two Nos thimbles, including painting of exposed MS work with two coats of aluminium paint over a coat of red oxide primer, with and including necessary excavation in soft / loose soil & disposal of surplus soil up to a distance 50m, PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation and loop insulator of size 140x90mm vitreous porcelain (White brown or green) etc complete all as specified and shown in electric plate No. 1 of SSR 2009 Part I including dismantling of old unserviceable stay assembly, complete all as directed
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium solid conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 with latest amendments, 10 sqmm, 4 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed.
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium stranded conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 latest date amendments, 16 sqmm, 4 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed.
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium stranded conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 with latest amendments, 25 sqmm, 4 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed.
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium stranded conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 with latest amendments, 50 sqmm, 3.5 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed.
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium stranded conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 with latest amendments, 70 sqmm, 3.5 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed.
Supplying, laying and testing of XLPE insulated, screened, PVC (E) bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) earthed with stranded compact circular aluminium conductor, 11000 volts grade of cross sectional area of size 95 sqmm 3 core, confirming to IS 7098 (Part-II) 2011 with latest amendments, laid in trenches fixed to wall or drawn through pipe, complete all as specified and directed
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium stranded conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 with latest amendments, 120 sqmm, 3.5 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed.
S&F XLPE insulated, galvanised steel strip or wire armoured electric power cables (Heavy duty) with aluminium stranded conductor, PVC inner sheathed, 1100 volt grade as per IS 7098 (Part-I) 1988 with latest amendments, 150 sqmm, 3.5 core cross sectional area laid in trenches/ laid under floor or fixed on walls / poles, complete all as specified and directed. Note for item no. 30 to 37:- Excavation & earth work and GI pipe (If any) shall be measured and paid separately under respective items of BOQ.
Supply and fixing steel tubular electric pole, swaged type, welded type, 410 SP-55 (11 meter long) complete with CI base plate, pole cap, bolts, nuts & screws all as specified including the following with and including dismantling of old existing unserviceable steel tubular electric pole:- (i) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in hard / dense soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (ii) M&L for providing PCC 1:4:8, type D-2 ( using 40 mm graded stone aggregate) in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (iii) M&L for providing PCC 1:3:6, type C2 ( using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (iv) M&L for providing PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia or as directed by EIC complete all as directed and as specified. (v) M&L for painting of pole externally with two coats of black bituminous paint up to planting depth. The remaining portion of exterior shall be painted with one coat of red oxide primer and above plinth block/ concrete collar with two coats of aluminium paint including preparation of surfaces including painting of 30 cm wide black and yellow bands (strips) 5 Nos with synthetic enamel paint in alternate layers up to the height of 1.5 Mtr above plinth block and writing pole number and feeder location by white synthetic enamel paint with proper letter size as directed.
M&L for painting to LT steel tubular poles including cross arms, street light brackets, earth pipe, clamps with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands / straps 25cm wide with paint red signal post office colour and 2 bands 25cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100mm height with white paint in black box of size 125x125mm, complete all as specified and directed by Engineer - in - Charge
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to with and including earth lead of 32x6 mm size GI strip up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth strip protected by galvanised iron 40 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including conctrete pit shall be PCC 1:3:6 tye C -1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing strip shall be encased in and including 40mm nominal bore GI 'light grade' tubing with all fittings from earth plate upto transformer mounted on PCC plateform shall be provided & charcoal / salt funnel & other fittings etc. complete all as specifed and as directed. Note :- (i) Item includes the cost of 7.5M GI pipe for protection of earth. (ii) Item includes cost of 7.5 M earth lead strip. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Supply & laying LT rubber mat of 1000x2000x10mm thick, complete all as specified and directed.
Supply & laying LT rubber mat of 1000x2000x19mm thick, complete all as specified and directed.
S&F in repairs PVC hosepipe, 100 mm dia branded heavy duty of best quality as approved by Engineer- in-charge, complete all as directed.
S&F in repairs PVC hosepipe, 40 mm dia branded heavy duty of best quality as approved by Engineer- in-charge, complete all as directed.
Dismantling of old unserviceable drop out fuse and S&F new 11000 Volt expulsion fuse single pole, swing out type, current carrying capacity above 50 Amps and up to 100 Amps, complete all as specified and directed
Pruning / trimming of tree branches not more than 100 mm dia surrounding 2.0 mtr wide all around the LT/HT overhead line, cleaning the site and removing the cutted branches outside the MD land complete all as directed. Note :- (i) Distance between two poles considered as one span. (ii) The contractor must ensure that there must be no damage to HT conductor / pole because of falling of tree branches. If any damage occurs due to this, the contractor at his own cost will do repair the same.
Disconnecting and taking out ACSR conductor with GI earth wire of any size from LT OH line & existing cross arms, by loosing the binding wire from the insulator wherever necessary. Re-fixing /restraining, securing, tightening the same including cutting the tree branches, obstacle to the OH lines (approx 3.00 metres clearance all around the outer conductor) and bushes on ground in each span n.exc 35 m (average) for three phase and neutral with street light feeder and GI guard wire complete all as specified and directed. Note :- The contractor must ensure that there must be no damage to HT conductor / pole because of falling of tree branches. If any damage occurs due to this, the contractor at his own cost will do repair the same.
Disconnecting and taking out ACSR conductor with GI earth wire of any size from LT OH line & existing cross arms, by loosing the binding wire from the insulator wherever necessary. Re-fixing /restraining, securing, tightening the same including cutting the tree branches, obstacle to the OH lines (approx 3.00 metres clearance all around the outer conductor) and bushes on ground in each span n.exc 35 m (average) for three phase and neutral with GI guard wire, complete all as specified and directed. Note :- The contractor must ensure that there must be no damage to HT conductor / pole because of falling of tree branches. If any damage occurs due to this, the contractor at his own cost will do repair the same.
Disconnecting and taking out ACSR conductor with GI earth wire of any size from LT OH line & existing cross arms, by loosing the binding wire from the insulator wherever necessary. Re-fixing /restraining, securing, tightening the same including cutting the tree branches, obstacle to the OH lines (approx 3.00 metres clearance all around the outer conductor) and bushes on ground in each span n.exc 35 m (average) for one phase and neutral with GI guard wire, complete all as specified and directed. Note :- The contractor must ensure that there must be no damage to HT conductor / pole because of falling of tree branches. If any damage occurs due to this, the contractor at his own cost will do repair the same.
Supplying and spreading graded course stone aggregate of gauge 80mm to 150mm, beneath the four / two pole structure and surrounding area of existing transformer by removing the existing vegetable growth, bushes from roots and levelling the ground, complete all as directed by Engineer in Charge.
S&F in replacement of GI pipe 40 mm bore, light grade as in cable protection, complete all as specified and as directed.
S&F in replacement of GI pipe 80 mm bore, light grade as in cable protection, complete all as specified and as directed.
Taking down outdoor / Indoor type transformer from foundation /platform carefully, by dismantling connections for repair and transporting the same up to the factory, drain out oil from the transformer, dismantling and taking out burnt primary and secondary coil of transformer of 75 KVA /100 KVA, 11KV/415 Volt capacity, copper bound, to ascertain the defective HV/LV coils, rewinding made of copper binding coil of suitable size according to the capacity of transformer with packing/insulating material complete, cleaning of cooling fins/radiator and re-assembling the same after renewal of defective parts and testing the transformer at factory, transporting back to AGE Banbasa and re-fix the same on its original location / position , reconnecting all electric connections and commissioning complete all as directed. Note:- (i) The cost of fixing of Spare parts shall be deemed to be included in quoted rates. (ii) Spare parts (if any) required for smooth functioning of transformer shall be measured and paid separately under respective items of BQO as supply only. (iii) After opening of transformer, list of defective/unserviceable parts shall be prepared jointly by Engineer-in-Charge and the Contractor. (iv) The contractor shall furnish two year written guarantee from the certified date of completion of work
Supply only the following items suitable for transformers of existing make & capacity, complete all as directed:- (a) HV bushing 11 KV grade with brass spindle- 4 Nos. & hexagonal nuts, suitable for transformer capacity 75 KVA/100KVA
(b). LV bushing 11 KV grade with brass spindle- 4 Nos. & hexagonal nuts, suitable for transformer capacity 75 KVA/100KVA
(c). Rewinding of LT Side coil with copper insulating winding wire of existing gauge.
(d).Rewinding of HT Side coil with copper insulating winding wire of existing gauge.
(e). Breather assembly of required size.
(f). 40mm dia bore stop valve cast copper alloy screwed down high pressure (drain valve)
(g). Oil temperature gauge dial type.
(h). Cork sheet gasket
Taking down existing unserviceable Volt meter and S&F new Volt Meter (0-500V), 3 phase, 415 volt complete all as directed.
Taking down existing unserviceable Amp meter and S&F new Amp Meter (0-500V), 3 phase, 415 volt complete all as directed.
M&L for painting of transformer 11 KV, 415 V (50 to 200 KVA) indoor / outdoor type installed at 4 pole structure or on floor, including cleaning, scrapping of exposed surfaces and applied one coat of synthetic enamel paint of approved shade with spray machine, including writing MES No. and Machine No. with black paint with letter size 15 mm wide and 50 mm long, complete all as specified and directed.
S&F in repairs battery brass terminals heavy duty of approved quality complete all as directed
S&F in repairs PVC foot valve of size 100 mm dia (As per sample kept with AGE), complete all as directed.
S&F in repairs aluminium lugs of size 95 to 150 Sqmm complete all as specified and directed
S&F in repairs aluminium lugs of size 70 Sqmm complete all as specified and directed
S&F in repairs aluminium lugs of size 50 Sqmm complete all as specified and directed
Disconnecting & dismantling of complete GOD, 11 KV, repair & overhauling, checking the serviceability of spares & operating mechanism, replacement of defective/worn out spares for making the GOD functional including operating mechanism, oiling, greasing of moving parts, fine setting of mechanism making the GOD perfect operational in manual mode, complete all as directed. Note:- Spare parts shall be measured and paid separately under respective items of BOQ as “Supply only”
Supply only tinted copper fuse wire, 16 amps, complete all as directed.
Supply only tinted copper fuse wire, 20 amps, complete all as directed.
Supply only tinted copper fuse wire, 25 amps, complete all as directed.
M&L for painting to HT steel tubular poles (11 m high), two pole structure including cross arms, street light brackets, earth pipe, clamps with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands / straps 25cm wide with paint red signal post office colour and 2 bands 25cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100mm height with white paint in black box of size 125x125mm, complete all as specified and directed by Engineer - in - Charge.
M&L for painting to HT steel tubular poles (11 m high), four pole structure including cross arms, street light brackets, earth pipe, clamps with one coat of aluminium paint including preparation of old painted surfaces properly and providing 3 bands / straps 25cm wide with paint red signal post office colour and 2 bands 25cm wide with white synthetic enamel paint 300 mm apart from plinth block and numbering of poles 100mm height with white paint in black box of size 125x125mm, complete all as specified and directed by Engineer - in - Charge.
S&F in repairs LED security light 40 watts LED luminaries comprising of aluminium PDC housing, toughened glass cover with IP66 protection, fixing with and including 40 mm dia GI pipe, light grade, 1.20 m long including clamps, nut & bolts etc and making electric connection with & including 1.5 Sqmm, 3 core PVC copper conductor cable, complete all as specified and directed. Make:- Surya (CAT PART No.-SLE UL 40W IP66 LXN) or equivalent CAT PART of Havells / Bajaj
S&F in repairs LED security light 25 watts LED luminaries comprising of aluminium PDC housing, toughened glass cover with IP66 protection, fixing with and including 40 mm dia GI pipe, light grade, 1.20 m long including clamps, nut & bolts etc and making electric connection with & including 1.5 Sqmm, 3 core PVC copper conductor cable, complete all as specified and directed. Make:- Surya (CAT PART No.-SLE UL 25W IP66 LXN) or equivalent CAT PART of Havells / Bajaj
Taking down existing street light fitting (LED 25 to 45 watts), any type from existing electric poles, de-assembling and testing of parts for serviceability, sorting serviceable and unserviceable parts and replacing unserviceable parts with new one and re-assembling the same by using new accessories, with and including S&F new copper wire 3 core 1.5 sqmm of suitable length for making internal connections, testing and re-fixing in its original location, complete all as directed. Note:- New spare parts shall be measured and paid separately under respective items of BOQ as supply only
Supply electronic driver of LED 45 Watt, suitable for LED security light, complete all as directed
Supply electronic driver of LED 25 Watt, suitable for LED security light, complete all as directed
S & F Automatic street light timer switch Single phase 3 kw 230V Swadeep -02 EC 3 KW 1P model as a pole mountable SMC Enclosure consisting of nature switch -02 as the controlling unit, power contactor(s) & MCBs 25 A (both in input-output) of suitable power rating and copper wiring (Min 10 Sq mm size) with proper lugs & terminal blocks. The SMC enclosure comes complete with openable door and mounting clamps. The Sintex make enclosure is made of UV stabilized. FR grade special moulding compound and shall be rust proof, Electric Shock proof, Termite proof, outdoor openable mountable confirming to IP-54, complete all as directed Make - Swadeep -02EC 3 KW1P or equivalent cat part of make Hager / L&T.
M&L for providing precast reinforced cement concrete 1:2:4 type B-1 as in cover slab and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in cement mortar 1:4, complete all as specified & directed.
M&L for finding out the fault of underground LT cable 3.5 core /4core up to 50 Sq mm by digging of existing trench and removing the brick protection cover and all material and restore the supply by using LT straight through joint and making good as per existing, complete all as directed. Note :- (i) The cost of Straight through joint shall be deemed to be included in quoted rates. (ii) Excavation & earth work, sand, brick protection cover, returning filling, removing of surplus soil will be measured and paid separately under respective items of BOQ.
M&L for finding out the fault of underground LT cable 3.5 core /4core above 50 Sq mm to 150 Sqmm by digging of existing trench and removing the brick protection cover and all material and restore the supply by using LT straight through joint and making good as per existing, complete all as directed. Note :- (i) The cost of Straight through joint shall be deemed to be included in quoted rates. (ii) Excavation & earth work, sand, brick protection cover, returning filling, removing of surplus soil will be measured and paid separately under respective items of BOQ.
S&F PVC junction box with hinged type door locking arrangement and two Nos. suitable mounting clamp of white colour suitable to accommodate one MCB SP 230 V, 6 Amps, incoming & outgoing two cable gland as per requirement size of cable with aluminium bus bar 04 Nos. of suitable size on insulator fitted in the box, complete all as directed. Make : Hansal / Sintax / Havells
shivam builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .