Loading…
Loading…
Tender Value
₹9.9 Cr
EMD Value
₹9.9 L
Closing Date
8 Jul 2026, 5:00 pm
Similar tender results from the same govt authority in the past 3 years.
Deputy Municipal Commissioner, North Zone
CONSTRUCTION OF INDULAL YAGNIK COMMUNITY HALL AFTER DEMOLITION OF OLD HALL BUILDING AT F.P.NO. 192, T.P.S.NO. 12 (ASARVA EXTENSION SOUTH ) IN BAPUNAGAR WARD, NORTH ZONE, AHMEDABAD (RE-INVITE)
316938
E Tender Notice No. 02/2025-26 Tender No.03
Open
Civil Works
Ahmedabad
4 documents required · 4 mandatory
₹12,000
Municipal Commissioner, Ahmedabad
₹9.9 L
25 Jun 2026
25 Jun 2026
25 Jun 2026
8 Jul 2026
25 Jun 2026
Name of Work:- CONSTRUCTION OF INDULAL YAGNIK COMMUNITY HALL AFTER DEMOLITION OF OLD
HALL BUILDING AT F.P.NO. 192, T.P.S.NO. 12 ( ASARVA EXTENSION SOUTH ) IN
BAPUNAGAR WARD, NORTH ZONE, AHMEDABAD
Bill of Quantities
I. No. Qty Items Unit Rate Per Amount
Civil Work Estimate
1 Demolition & Dismantling work
Demolition of RCC work using Hydra
Breacker including stacking of servicable
materials and disposal of unservicable
materials with all lead and lift.Removal Of
Existing Building Foundation and Super
Structure If Any.
Demolition of Brick work and stone masonry
including stacking of serviceable materials
and disposal of unserviceable materials
with all lead and lift.(ii) In Cement
Mortar.Removal Of Existing Building
Foundation and Super Structure If Any.
Dismentaling of sheet roofing including
ridges, Hips, Valleys, Gutters etc. stacking
c of serviceable materials and disposal of
unserviceable materials with all lead and lift.
i 5 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including
d 1000 distempering and stacking the materials 3.63 Kg.
with all lead and lift.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including
chowkhats architraves, hold fasts and other
e 2 185.85 Each
attachment etc. complete and stacking
them with in all lead and lift.
(i)Notexceeding 3 Sq.M. in area.
Removing & Scrapping of Old deteriorated
Plaster of any thickness from Masonary /
R.C.C. member including stacking of
serviceable material & disposal of un
serviceable from site of work with all lead &
Dismentaling any type tiled of stone floors
laid in mortar including stacking of
g 100 serviceable materilas and disposal of 47.25 Sq.M.
unserviceable materials with all lead and lift.
Excavation for foundation including sorting
out stacking of useful material & disposing
2 of excavated stuff upto 50 mt. lead. Loose &
Soft soil.Excexuted With Mechanical Effort
a 2700 up to 1.5 mt. depth 115.92 Cu.M.
b 2531 1.5 to 3.0 mt. depth. 128.52 Cu.M.
c 3325 3.0 to 5.0 mt. depth 141.11 Cu.M.
d 1229 above 5.00 mt. depth 162.02 Cu.M.
Add extra for Disposing off the excavated
e 200 stuff of above items for lead of (A) 50 m to 17.28 Cu.M.
Add extra for Disposing off the excavated
f 200 stuff of above items for lead of (B) 100 m to 34.56 Cu.M.
Providing and installing cast in situ single
under reamed piles of specified diameter
and length below pile cap, excluding the
cost of Concrete, steel reinforcement but
g including the cost of boring with bentonite
solution and the length of the pile to be
embedded in pile cap etc. all complete.
(Length of pile for payment shall be
measured upto to the bottom of pile cap) :
i 10 400 mm dia. Piles 644.63 Rmt.
ii 10 450 mm dia. Piles 705.03 Rmt.
Extra over single under ream for providing
additional bulbs in under reamed piles,
h under specified diameter excluding the cost
of Concrete, steel reinforcement (only the
nos. of extra bulbs are to be paid).
t 1 400 mm dia. Piles 813.05 Each
ii 1 450 mm dia. Piles 1103.43 Each
Provdg. & laying cement concrete 1:5:10 (1
cement : 5 course sand : 10 hand broken
3a 1 aggregates 40 mm nominal size) and curing 2492.51 Cu.M.
complete, excluding cost of form work in
foundation & Plinth.
Provdg. & laying cement concrete 1:3:6 (1
cement : 3 coarse sand : 6 hand broken
3b stone aggregates 40 mm nominal size) and
curing complete excluding cost of form work
562 (A) Foundation and plinth 2976.00 Cu.M.
Supplying of graded hand brocken stone
3c 198 size of 90 mm to 127 mm at site (Rubble or 983.93 Cu.M.
Labour charges for spreading the spouls
mm to 127 mm thick layer good earth filling
in voids correcting the grade & camber
comp. with rolling, watering, incl. preparing
thesurface by brushing for removing all
loose or dirts ect.comp.
Provdg. & laying cement concrete 1:4:8 (1
cement : 4 coarse sand : 8 hand broken
4 2 stone aggregates 40 mm nominal size) and 2653.67 Cu.M.
curing complete excluding cost of form work
in foundation& plinth.
Filling available excavated earth (excluding
rock) in trenches, plinth, sides of
5 2500 foundations etc. in layers not exceeding 20 129.10 Cu.M.
cm. in depth consolidation each deposited
layer by ramming and watering.
Conveyance charges of earth lime, murrum,
building rubbish, manure, garbage, sludge,
6 excavated rock, fly ash, aggregate of any
kind etc. comp.
a 100 Conveyance charges upto 1 km 320.20 Cmt
b 100 Conveyance charges upto 2 km 347.73 Cmt
c 12000 Conveyance charges upto 5 km 408.41 Cmt
Extra For Lead on Above Item Above 5 km
d 12000 & upto 6 km 9.26 Cmt
Extra For Lead on Above Item Above 6 km
e 12000 & upto 7 km 9.26 Cmt
Extra For Lead on Above Item Above 7 km
f 12000 & upto 8 km 9.26 Cmt
Extra For Lead on Above Item Above 8 km
g 12000 & upto 9 km 9.26 Cmt
h 12000 Extra For Lead on Above Item Above 9 km 9.26 Cmt
Filling in plinth with sand under floors
7a 15 including watering, ramming, consolidating, 455.63 Cu.M.
compacting and dressing etc. completed.
Filling in foundation and plinth with murrum
or selected soil in layers of 20 cm. thickness
7b 300 including watering, ramming and 286.20 Cmt
consolidating etc. Complete.
Brick work using common burnt clay
building bricks having crushing strength not
8 less than 35 kg/Sq. cm. in cement mortar
1:6 (1 cement : 6 fine sand) conventional
a 110 (a) in foundation & Plinth 3981.21 Cu.M.
b 366 Super structure Upto Floor Two Level 4253.46 Cu.M.
c 83 Super structure Above Floor Two Level 4293.55 Cu.M.
I.Half brick masonry in common burnt clay
building bricks having crushing strength
note less than 35 Kg/Sq. Cm. in cement
mortar 1:4 (1 cement : 4 coarse sand) using
conventional brick in Super structure upto
floor Four level
a 295 All Floor Level 646.70 Sq.M.
Providing and laying controlled cement
concrete of M-25 Grade and curing
complete, Excluding the cost of form work,
Scaffolding, cost of reinforcement for
reinforced concrete work For any Height up
to any FloorLevel.
a 24 Foundations,Raft,Footings,Mass concrete 4238.04 Cu.M.
b1 2 RCC Retaining wall at All Floor 4519.88 Cu.M.
Tie-Beam, Lintel , Beam- Bracket, Stair
Case & Landing, Coping ,Slab, balcony,
weather shed, loft , any cantilever etc All
Columns,Pillars, posts and struts at All
Providing and laying controlled cement
concrete of M-20 Grade and curing
complete, Excluding the cost of form work,
Scaffolding, cost of reinforcement for
reinforced concrete work For any Height up
to Floor Four Level.
a 5 Foundations,Raft,Footings,Mass concrete 3977.88 Cu.M.
Tie Beam , Lintel , Beam- Bracket , Coping
b1 36 ,landing, Slab, balcony, weather shed, loft , 4460.36 Cu.M.
any cantilever etc at All Floor
c1 2 Column at All Floor 4558.20 Cu.M.
d1 1 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready
Mixed M250 grade concrete for reinforced
cement conctere work , using cement
content as per approved Design Mix
manufactured in fully automatic batching
plant and transported to site of work in
transit mixer for all lead having continuous
agitated mixer, manufactured as per mix
design of specified grade for reinforced
cement concrete work including pumping of
R.M.C. from transit mixer to site of laying
with all lead and lift, excluding the cost of
centering shuttering finishing and
reinforcement including cost of admixtures
in recommended proportions as per IS:
9103 to accelerate/ retard setting of
concrete, improve workability without
impairing strength and durability as per
direction of the Engineer - in charge.
Without Fly Ash (Min cement level as per
latest IS 456 shall be maintained) (Cement
Providing and laying in position Ready
Mixed M200 grade concrete for reinforced
cement conctere work , using cement
content as per approved Design Mix
manufactured in fully automatic batching
plant and transported to site of work in
transit mixer for all lead having continuous
agitated mixer, manufactured as per mix
design of specified grade for reinforced
cement concrete work including pumping of
R.M.C. from transit mixer to site of laying
with all lead and lift, excluding the cost of
centering shuttering finishing and
reinforcement including cost of admixtures
in recommended proportions as per IS:
9103 to accelerate/ retard setting of
concrete, improve workability without
impairing strength and durability as per
direction of the Engineer - in charge.
Without Fly Ash (Min cement level as per
latest IS 456 shall be maintained) (Cement
Drilling suitable holes in reinforced or plain
cement concrete with power driven drill
machine to a minimum depth of 80mm upto
250mm in RCC beams, lintels, columns and
slabs to introduce steel bars for
sunshades/balconies including fixing the
steel bars in position using Hilti Chemical
HY200-R but excluding the cost of
reinforcement, all complete as per direction
of Engineer-In-Charge.
8 mm Dia in 80 mm Deep & 12 mm Dia
10 mm Dia in 100 mm Deep & 14 mm Dia
12 mm Dia in 120 mm Deep & 16 mm Dia
16 mm Dia in 160 mm Deep & 20 mm Dia
d 60 608.63 Each
20 mm Dia in 200 mm Deep & 25 mm Dia
25 mm Dia in 250 mm Deep & 32 mm Dia
Providing and laying controlled cement
concrete 1:2:4( 1cement : 2 coarse sand :
Graded stone aggregate 20 mm nominal
size ) and curing complete, Excluding the
cost of form work and reinforcement for
reinforced concrete work in:
Foundations, footings, base of
a 1 columns,grade slab and mass concrete. 3923.53 Cu.M.
slab, landing shelves, Balconies, lintels,
b 1 beams, girders, and cantilever, up to aany 4012.47 Cu.M.
P/A Trimix with dewatering machine and
floater machine on constructed R.C.C. work
c 2534 54.00 Sqmtr
incl. cost of machine and labour etc. comp.
Making 15 mm Groove in R.C.C work on
road and filling it with poly sulfied selant and
d 950 finished it good incl. all labour charges etc. 30.00 Rmt
comp. as directed
Providing and laying and fixing 25 mm thick
expansion joint by hydrocell semi rigid UV
e 21 resistance with high performance laminated 738.13 Sqmt
closed cell polythene foam joint filler in
sheet foam as directed, etc. complete.
Providing form work in ordinary timber
planking so as to give a rough finish
including centering, shuttering, strutting and
propping etc. height of propping and
centering below supporting floor to celling
not exceeding 4 M & removal of the same
for in situ reinforced or plain concrete work
(A) Foundation, footings, bases of columns
a 836 etc. and mass concrete. 171.68 Smt
(B) Flat surface such as soffits of slabs,
b 3249 landing and the like 252.00 Smt
(C) Vertical surfaces such as walls (any
c 3199 thickness) partitions. 229.95 Smt
(D) Columns, pillars, posts & struts.
d 2044 (1) Square, rectangular, polygonal in plan 297.68 Smt
e 20 (2) Circular or curved in plan. 422.10 Smt
(H) (1) Sides and soffits of beam,
haunchings cantilevers, girders,
bressumers, Coping and lintels not
exceeding 1 M in depth.
(2) Sides and soffits of beam, haunchings
g 10 cantilevers, girders, bressumers and lintels 259.88 Smt
exceeding 1 M in depth.
(L) chullah hoops, weather sheds, chhajas,
h 106 carbels etc including edges. 155.78 Smt
(M) Staircase with-sloping or stepped soffits
i 110 incl. risers & strings excluding landing. 242.55 Smt
Extra for additional height of propping and
centering where the height of propping and
centering exceeds 4 .O M between
j 2500 supporting floor to ceiling including 386.48 Smt
temporary brick or stone pillars for
supporting as required. (i)Height more than
4.0 M.and upto 5.0 M.
Extra for additional height of propping and
centering where the height of propping and
centering exceeds 4 .O M between
k 60 supporting floor to ceiling including 573.30 Smt
temporary brick or stone pillars for
supporting as required. (i)Height more than
6.0 M.and upto 7.0 M.
Providing T.M.T Fe 500D bar reinforcement
for R.C.C. work including bending, binding
and placing in position complete up to any
a 264172 All Floor Level 75.46 Kg.
Providing and laying polished Kota stone
slab (Polished / River Finish, Green colour )
flooring over 20 mm. (average) thick base
14 170 of cement mortar 1:6 (1 cement : 6 coarse 982.83 Sq.M.
sand) or lime mortar 1:1.5 laid over and
joined with grey cement slurry including
rubbing and polishing complete.25 mm th.
Providing and laying polished Kota stone
slab 25 mm. thick in Platform ,Riser of Stair
, Skirting, Tread , dado and pillars laid on
10 mm. thick cement mortar 1:3 (1 cement :
3 coarse sand) jointed with grey cement
slurry including rubbing and polishing and
MAking groove where it is Required etc.
Providing and laying white/Colur glazed
tiles 6 mm thick in flooring treads of steps
and landing laid on a bed of 12 mm thick
cement mortar 1:3 (1 cement : 3 coarse
sand) finished with flush pointing in white
Providing and layingWhite / Colour glazed
tiles of size 600 mmx300mm x 8 mm /
mmx 450mm x 8 mm in skirting, risers of
steps, Floor and dedo on 10 mm. thick
cement plaster 1:3 (1 cement : 3 coarse
sand) and jointed with white cement slurry.
Providing and laying marble stone slab
flooring over 20 mm. (Average) base of
cement mortar 1:6 (1 cement: 6 coarse
18 2 sand) or L.M. 1:1.5 laid and jointed with 2194.63 Sq. M.
grey cement slurry including rubbing and
polishing complete: (A) Marble slab 25 mm.
Providing and laying Vitrified tiles 8 to
mm thick , 24'' x 24'' in flooring treads of
steps and landing laid on a bed of 12mm
thick cement mortar 1:3 (1-cement : 3-
coarse sand) finishing with flush pointing in
Providing and laying Vitrified tiles 8 to
mm thick , 24'' x 24'' in skrting risers of
19b 893 steps and dedo on 10mm thick cement 1130.15 Sq. M.
plaster 1:3 (1cement : 3-coarse sand) and
jointed with white cement slurry
P & L 24" x 24" vitrified 8 mm thick tile
20 mm (average) base of cement mortar
1:6 ( 1cement: 6 coarse sand) on new
surface or fixing on existing flooring by
adhesive material including dismentaling of
existing flooring and jointed with color
cement slurry including finised with flush
pointing & cleaning the surface etc.
complete for Antiskid
Providing and Laying Tactile Tile (For
Vision Impaired Persons as per Strandards)
of Size 300x300x9.8 mm Having with Water
Absorption less than 0.5% and Confirming
to is:15622 of Approved Make in all Colours
and Shades in for Outdoor floors such as
19d 210 footpath, Courtyard, Multi models Location 1663.72 Sq. M.
etc., laid in 20 mm Thick Base of Cement
Mortar 1:4 ( 1 Cement : 4 Course Sand) in
all Shapes & pattern including Grouting the
Joints with White Cement mixed with
Matching pigment etc. Complete as per
Direction of Engineer-in-charge.
Providing and laying Ceramics tiles 6 to
mm thick in flooring, treads of steps, landing
20 10 and dedo on 12 mm. thick cement plaster 960.47 Sq. M.
1:3 (1 cement : 3 coarse sand) and jointed
with white cement slurry.
Providing & Laying 18 mm thick Mirror
polish granite For flooring , counter , stair -
riser , tread , skirting , dedo , Jambs etc.
machine cut or chiselled on bed of cement
mortar 1:1 pointing with neat cement slurry
incl. moulding, Making grooves where it is
required etc. comp. as per instruction of
engineer in charge.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat on fair side of brick /
22a concrete walls for interior plastering upto
any Floor level and finished even and
smooth in C.M.1:4.
i 4866 All Floor Level 190.58 Sq.M.
Provdg. 20 mm. thick Finish / Mala cement
plaster in single coat plastering on ceilings,
b Beam side and sofits of stairs upto any
Floor level and finished even and smooth in
i 3750 All Floor Level 215.15 Sq.M.
Providing & fixing 23 cm wide chicken mesh
jali with nails & then application of 15 mm
c 621 plaster on R.C.C. & masonary joints as per 292.59 Sq.mt
dir. of engg. In charge.
Providing and mixing water proofing
materials in cement mortar in proportion
d 150 recommended by the manufacturer. etc. 48.77
comp. as per instruction of engineer in
Providing 20 mm th. Double coat Sand face
/ Mala Cement Plaster on Walls upto any
Height Above Ground level consisting of
23a 2404 mm th. Backing coat of C.M. 1:3 ( 1 cement 297.68 Sq.M.
: 3 Ssand ) & 8 mm th. Finishing coat of
C.M. 1:1 ( 1 cement : 1 sand ) ets.
White / Color washing with lime on
undecorated wall surfaces (two coats) to
24a 50 give an even shade including thoroughly 12.29 Sq.M.
brooming the surface to remove all dirt, dust
mortar drops and other foreign matter.
Providing & Applying 3 mm thick External
Wall Rustic Type Texture as per Design &
Make as Approved by Consultants /
Engineer in Charge. Work Includes All
Necessary Scaffolding Work upto Any
Finishing walls with Acrylic Smooth exterior
paint of required shade :New work (Two or
24 c 2700 more coat applied @ 1.67 ltr/10 sqm over 174.97 Sq.M.
and including priming coat of exterior primer
applied @ 2.20 kg/10 sqm)
P./L. METALIC HERITAGE SURFACE
Providing and fixing of HERITAGE textured
homogeneous wall finishing system from
BAKELITE HYLAM LTD or equivalent make
consisting of a two component system of
(25 kgs per Pack) made of 92% silica
particles coated with fade resistant
pigments, 100% acrylic polymer bonding
agent (5kgs per pack) with the applied
thickness of the coating being between
0.8mm-1.2mm to be applied on acured,
smooth level plaster without keying, as per
the shades/combinations approved, as per
the manufacturer directions, for usages,
tobe applied by an approved applicator of
the manufacturer, as per the directions /
supervision of the engineers in charge, all
complete. Includes All Necessary
Scaffolding Work upto Any Height.
Wall Painting (two coats) with plastic
emulsion / Oil paint of approved brand and
manufacture and of shade required on
undecorated wall surfaces to give an even
shade, over and including a priming coat
25a 4100 with alkali resistance primer of approved 78.44 Sq.M.
brand and manufacture after thoroughly
brushing the surface free from mortar
droppings, and other foreign matter and
also including preparing the surface even
and sand -papered smooth
Extra over above item for every subsequent
b 4100 coat of of wall painting with plastic emulsion 33.39 Sq.mt.
/ Oil paint of approved brand.
Applying two coats of Birla (white cement
based) or Asian (acrylic lapy-putty) or
equivalent & two coats of primer of
approved brand and manufacture on new
wall surface to give an even shade
including thoroughly brushing the surface
free from mortar dropping and other foreign
matter and sand papered smooth.
Providing and supplying ISI marked only
standard length Stonewate pipes in
standard lengths of following class and
diameter including all taxes,insurance,
transportiton, fright charges,
octroi,inspection charges,
loading,unloading, conveyance to
departmental stores, stacking etc. complete
a 120 23 cm dia. 299.00 Rmt
Lowering, laying and jointing stone ware
pipes of following diameters with cement
joints in C.M.1:1 proportion in proper
position , grade and alignment at all level as
directed by Engineer-in- charge including
conveyance from stone to site of work,
Jointing material etc.comp.
b 120 23 cm dia. 128.00 Rmt
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
mt.,refilling, trasporting the pipe to work
site, unloading, lowering in trenches, laying
and jointing the pipes in c.m. 1:1 incl. all
26 jointing materials such as cement, sand,
hemp, bitumen as dire. testing the pipe line
to a head of 1.5 mt. and hydraulic test as
dire incl. watering trenches, spreading , and
carting away of surplus earth within
mt.lead as dire. etc. comp.
c 25 15 cm dia 288.23 Rmt
d 15 10 cm dia. 211.05 Rmt
Constructing brick masonry chamber for
under ground C.I. Inspection chamber and
bends with bricks having croshing strength
not less than 35 Kg. Cm2 in C.M. 1:5 C.I.
cover with frame (Lightduty) 455mm x
mm intenal dimensions total weight of cover
with frame to be not less than 38 Kg. (Wt. of
cover 23Kg.) and Wt. of frame 15Kg.)
(R.C.C.top slab with 1:2:4 mix (1-cement:2-
coarse sand:4-graded stone aggregate
20mm size) foundation concrete 1:5:10
inside plaster 15 mm thick with cement
mortar 1:3 finished smooth with a floating
coat of neat cement on walls and bed
concrete etc. complete.(i) Inside dimensions
455 mm x 610 mm and up to 850 mm deep
Constructing Manhole with R.C.C. top slab
in 1:2:4mix (1-cement: 2-coarse sand:4-
graded stone aggregate 20 mm nominal
size) foundation concrete 1:3:6 mix (1-
cement:3-coarse sand:6-Brick bats
40+50mm size) inside plastering 15mm
thick with Cement Mortar 1:5 (1-Cement:5-
coarse sand) finished with a floating coat of
neat cement and making channels in
cement concrete 1:2:4 mix (1-Cement:2 -
Coarse sand:4-stone aggregate 20 mm
28 a 4 nominal size) finished smooth complete 19139.07 No.
including curing and festing (i) Inside size
900mm x 1200mm and up to 1.5M. deep
including C.I. cover with frame size 560 mm
diameter total weight of cover and frame to
be not less than 128kgs. (Wt. of cover
64Kg. and Wt. of frame 64Kg.) (A) With
mm thick walls of brick masonry using brick
having crushing strength not less than
35Kg./Sq.cm. in Cement Mortar 1:5 (1-
Cement: 5-Coarse sand) (2)B type depth up
Providing and fixing white vitreous china flat
back or wall corner type lipped front urinal
basin of 340x280x470 mm sizes
respectively with standard flush pipe,
Waster Pipe, Waste Coupling, PVc
Connection and G.I clamps complete,
including painting of fittings and brackets,
cutting and making good the walls and
floors wherever required : Cera Model No.
S4020103 or Equivalent
Providing and Fixing of C.P. Brass BIB
Cock of 15 mm Dia of Jaquar make
b 34 florentine series model no. 5047n or 1564.17 No.
equivalent make with all necessary fittings.
as approved by Engineer - in - charge.,
Providing and fixing brass screw down
Angle stop tap.(A) 15mm dia. Of Jaquar
c 34 make florentine series modelno. 5053n or 1160.57 No.
equivalent make with all necessary fittings.
as approved by Engineer - in - charge.,
Providing and fixing C.P. brass shower rose
d 6 with 15mm or 20mm inlet Shower Arm.(A) 279.37 No.
100mm dia. Each
Provding and Fixing of autoclosing
pressmatic pillar cock / bib cock with all
necessary fittings of Polished Bright
e 12 Chrome Finish of Jaquar make model no. 3280.52 No.
031L65 or equivalent make as approved by
Engineer in Charge. Rate including of cost
of labour, material etc. in complete manner.
Providing and Fixing of C.P. Brass Two
Way Bib Cock of 15 mm Dia of Jaquar
f 22 make model no. 041kn or equivalent make 1411.58 No.
approved make with all necessary fittings.
as approved by Engineer - in - charge.,
Providing and Fixing of C.P. Brass urinal
Valve Auto Closing System With Full Built in
Control Cock & Wall Flange of 15 mm Dia
g 16 of Jaquar make model no. 077 or equivalent 2568.08 No.
make approved make with all necessary
fittings. as approved by Engineer - in -
Provdg. & laying S.W. Gully trap with C.I.
garting brick masonry chamber & water
30 12 tight C.I. cover with frame of 300 mm x 300 1234.57 No.
mm size ( inside) with standard weight.
sqare mouth trap size 150 x100 mm P trap
Providing erecting and fixing double coated
ISI water tank of required capacity each
31 2000 with all necessary fittings and connection 3.91 Litre
etc. complete on terrace
Extra rate over item of excavation of earth
for excavation of asphalt pavement/RCC of
thickness up to 0.20 meter including
32 20 demolishing the asphalt carpet, metal, 71.42 Sq.M.
soiling / cutting Reinforcement etc.comp.
with stacking the material as directed.-up to
0.20 meter thickness
Providing and fixing PVC SWR Nahni trap
IS 14735 for drain - 100 mm diameter with
jali of the following nominal diameter of self
33 30 cleansing design with C.I scread down or 565.43 No.
hinged grating including the cost of cutting
and making good the walls.
Provdg. And fixing Concealed / Open to
wall, ceiling & floor in true line and level
UPVC pipe Schedule- 40 of make as
approved by engg. incharge. pipe shall be
fix on wall with the help of clamp at every
34a twi meter center to center of shall be
concealed as directed in cluding neccesarry
fitting etc. in cluding testing of pipe and
jointd and fixing the same with adhesive
solvent , including cost of all materials of
following nominal bore
i 60 15 mm 71.93 Rmt
ii 250 25 mm 90.93 Rmt
iii 30 32 mm 117.97 Rmt
iv 180 40 mm 146.65 Rmt
Providing and fixing concealed center point
to wall ceiling & floor CPVC (SDR 13.5)
PIPE having National Sanitation Foundation
34b (NSF) seal for potable water of following
dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and
floor etc. complete
i 5 15 mm 165.21 Rmt
ii 5 20 mm 202.97 Rmt
iii 5 25 mm 247.25 Rmt
iv 5 32 mm 330.36 Rmt
v 5 40 mm 437.66 Rmt
vi 5 50 mm 647.30 Rmt
Provdg. And fixing to wall ,ceiling and floor
10.00 kg. F/Sq.Cm2 working pressure
polythelene pipes of the following outside
35 diameter, low, density, complete with
special flange compression type fittings,
wall clips etc. making good wall ceiling and
b 70 (A) 75mm dia 274.68 Rmt
c 140 © 110 mm dia 332.91 Rmt
Providing and fixing water closet squatting
Pan ( Indian type W.C. Pan) size 580mm
36 8 (A)VitreousChina. (I)Long pattern = White 1351.49 No.
colour with Trap and Pair of Foot Rest
Providing and fixing white vitreous china
extended wall mounting water closet of
Cera Make S1043101 Carat Model Or
Equivalent Model With EWC Soft Close
Seat Cover, Chair Bracket, nuts, bolts and
gasket etc complete.
Providing and Fixing of C.P. Brass Flush
Cock of 25 mm Dia of Jaquar make model
no. 081 or equivalent and Outer Body of
b 24 Jaquar make model no. 5083KPM or 2732.58 No.
equivalent approved make with all
necessary fittings. as approved by Engineer
- in - charge.,
Providing and fixing Health Faucet of
Jaquar make model no. 573 oe equivalent
c 16 make as approved by engg. In charge with 1543.36 No.
flexible tube upto 1 metre long etc.
Providing and fixing 24"x18"x8" Carysil
Elegance or Equivalent Make of Single
38a 2 Bowl Sink S.S. Matt Finish With Waste 7960.49 No.
Coupling, Waste Pipe,etc. cutting and
making good the walls wherever required.
Providing and fixing Under counter Wash
basine including 15 mm C.P. Brass Pillar
tap, 32 mm C.P. Brass Waste of Standard
make, Cutting & Making good the wall /
granite Wherever Required in White Color :
Model S2030101 of Cera Clair Series or
Equivalent make Wash basine of size :
Providing and fixing Wall Hung wash basin
Including 32 mm C.P. brass waste of
standard pattern, cutting and making good
c 4 the walls / granite wherever require:In White 3825.20 No.
Color : Cera Cadal Or Equivalent Make
Wash basin of size 515 x 410 mm
Provdg. & fixing 600mm x 450 mm
Bevelled edge mirror of superior glass
39a 10 mounted of .6 mm th. A.C. sheet or plywood 825.48 No.
sheet and fixed to wooden pluge with C.P.
brass screws and washers.
Providing and fixing mirror of superior glass
(of approved quality) and of required shape
and size with plastic moulded frame of
approved make and shade with 6 mm thick
hard board backing : Rectangular shape
Provdg. & fixing C.P..Brass towal rail
complete with C.P. brass brackets fixed to
wooden plugs with C.P. Brass screws.(600
mmx 20 mm size)
Providing and fixing ball valve (brass) of
41 approved quality, High or low pressure, with
plastic floats complete :
i 8 15 mm dia 886.22 No.
ii 1 20 mm dia 1099.94 No.
iii 25 25 mm dia 1552.93 No.
iv 12 40 mm dia 3312.60 No.
v 4 50 mm dia 4613.48 No.
Providing and fixing Full Way valve (HEX)
42a with wheel of approved quality :
i 2 15 mm Full Way valve (HEX) 1461.17 No.
ii 2 20 mm Full Way valve (HEX) 1924.61 No.
iii 8 25 mm Full Way valve (HEX) 2535.55 No.
iv 1 32 mm Full Way valve (HEX) 3377.64 No.
v 8 40 mm Full Way valve (HEX) 4661.10 No.
vi 3 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass Pillar
Cock of 15 mm Dia of approved make with
all necessary fittings. as approved by
Engineer - in - charge.,
Providing fixing of SS grab bar with all
b 4 hardwares for Physically Handicap toilet. 1937.24 No.
Providing and laying integral cement based
water proofing treatment including
44a 1000 preparation of surface as required for 1150.48 Sq.M.
treatment of roofs, balconies, terraces etc
consisting of following operations:
(a) Applying a slurry coat of neat cement
using 2.75 kg/sqm of cement admixed with
water proofing compound conforming to IS.
2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls
upto 300 mm height including cleaning the
surface before treatment.
(b) Laying brick bats with mortar using
broken bricks/brick bats 25 mm to 115 mm
size with 50% of cement mortar 1:5 (1
cement : 5 coarse sand) admixed with
water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge
over 20 mm thick layer of cement mortar of
mix 1:5 (1 cement :5 coarse sand ) admixed
with water proofing compound conforming
to IS : 2645 and approved by Engineer-in-
charge to required slope and treating
similarly the adjoining walls upto 300 mm
height including rounding of junctions of
walls and slabs.
(c) After two days of proper curing applying
a second coat of cement slurry using
kg/ sqm of cement admixed with water
proofing compound conforming to IS :
and approved by Engineerin- charge.
(d) Finishing the surface with 20 mm thick
jointless cement mortar of mix 1:4 (1
cement :4 coarse sand) admixed with water
proofing compound conforming to IS :
and approved by Engineerin- charge
(e) The whole terrace so finished shall be
flooded with water for a minimum period of
two weeks for curing and for final test.“All
above operations to be done in order and
as directed and specified by the Engineer-
in-Charge :and shall be guaranteed for
minimum period of 10 years after handing
over the completed building by the main
contractor to be finished as directed.
Stamp paper guarantee 10 years to be
furnished before receiving any payment
from the client.
With average thickness of 120 mm and
minimum thickness at khurra as 65 mm.
Providing and laying broken chine mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
cement mortar 1:3 to plain or slope and to
b 1000 be tempered to bring mortar creme out upto 739.89 Sq. M.
surface using white cement including
rounding off junctions and extending them
upto 15 cm along the wall,clearing with
water and oxalic acid etc. as directed.
Providing and applying fibre reinforced
elastomeric liquid water proofing membrane
with resilient acrylic polymers having Sun
Reflectivity Index (SRI) of 105 on top of
concrete roof in three coats @10.76 litre/
sqm. One coat of self-priming of
elastomeric waterproofing liquid (dilution
with water in the ratio of 3:1) and two coats
of undiluted elastomeric waterproofing liquid
(dry film thickness of complete
application/system not less than
microns). The operation shall be carried out
after scrapping and properly cleaning the
surface to remove loose particles with wire
brushes, complete in all respect as per the
direction of Engineer-in-Charge.
Filling in Sunken Portion with good Quality
Aerated light weight concrete block having
crushing strength not less than 35 kg/sqcm
and where directed by the Architect /
Engineer-in-charge, in sunk in layer.
including watering, ramming where it is
required etc. complete, as directed by the
Architect / Engineer-in-charge .
Providing and laying cement concrete
flooring ( I.P.S.) 1:2:4 (1-cement : 2-coarse
sand : 4-graded stone aggregate 20mm
nominal size) laid in one layer and finished
with a floating coat of neat cement. (B)
Providing and fixing M.S. grills/ Gate of
required pattern to wooden/ Granite frames
of windows etc. with M.S. flats at required
spacings and frame alround, square or
round bars with round headed bolts and
nuts or by screws all complete as per the
structural designs and directions of
Engineer in charge
Providing & Fixing Structural steel work (
Confirming to IS 4923-1997) riveted, bolted
or welded in builtup for all type sections, in
framed work, including cutting, hoisting,
fixing in position and applying a priming
coat of approved steel primer all complete
as per the structural designs and directions
of Engineer in charge
Applying priming coat over new steel and
other metel surface after and including
preparing the surface by throughly cleaning,
c 600 oil, grease, dirt and other foreign matter and 34.34 Sqmt
scoured with brushes fine steel wood,
scrapers and sand paper with ready mixed
priming paint brushing red lead.
Painting two coats (excluding priming coat)
on new steel and other metal surface with
enamel paint, brushing, interior to give an
d 600 even shade including cleaning the surface 86.94 Sqmt
an even shade including cleaning the
surface of all dirt, dust and other foreign
Providing & Fixing 1 mm Thick S.S.-304
Grade 90 mm High S.S. Railing having
Hand Rail Member of 50 mm Dia., 3 No. of
Horizontal Pipe of 16 mm Dia. & Baluster
Suppprt of 40 mm Dia. At Every Third Step
as per Detail Given. Rate Includes All Work
Complete as per Description & as per
Direction of Engg. in Charge.
Providing and fixing in position collapsible
steel shutters with vertical channels
20x10x2 mm braced with flat iron diagonals
20x5 mm size with top & bottom rails of T-
iron 40x40x6 mm with 38 mm dia. Steel
pulleys complete with bolts , nuts , locking
arrangement , stoppers , handles including
applying a priming coat of red lead paint.
Providing corrugated 0.80 mm (22 gauge)
thick G.I. sheets roofing fixed with
galvanized iron ‘J’ or ‘L’ hook bolts, and
b 10 nuts 8 mm. dia with bitumen and G.I. limpet 719.93 Sq.M.
washers filled with white lead complete
excluding the cost of purlines, rafters and
Providing valleys 900 mm. overall in plain
1.6 mm. thick G.I. sheet Class – 3 fixed with
c 3 ‘J’ or ‘L’ hook bolts and nuts galvanized 1042.78 Sq.mt.
from ‘J’ or ‘L’ hook bolts and bitumen
washers complete.
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their
entire length and jointed together at the
ends by end locks mounted on specially
48a 9 designed pipe shaft with bracket plates, 3468.72 Sq.M.
guide channels and arragements for inside
and outside locking with push-pull operation
including the cost of hood cover and spring
etc. complete.(A) Shutters having width
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their
entire length and jointed together at the
ends by end locks mounted on specially
48b 30 designed pipe shaft with bracket plates, 4450.51 Sq.M.
guide channels and arragements for inside
and outside locking with push-pull operation
including the cost of hood cover and spring
etc. complete.(A) Shutters having width
Providing and fixing 27mm domal Series -
1.2 mm Th. Alluminium Section Three track
Sliding window With Metalic Powder
49a 115 Coating and 4 MM Clear Glaas(Non Tuffen) 6373.85 Sq. M.
Include All Accessaries and Fixture etc.
complete as per the direction of Engineer-
Providing and fixing 27mm domal Series -
1.2 mm Th. Alluminium Section Two track
Sliding window With Metalic Powder
b 14 Coating and 4 MM Clear Glaas(Non Tuffen) 4999.10 Sq. M.
Include All Accessaries and Fixture etc.
complete as per the direction of Engineer-
ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door work
(Single Shutter OR Double Shutter with fix
glass) made from Jindal or equivalent make
Powder Coated (50 micron pure polyester
coating ) ,aluminium section frame built up
standard tubular and other section of
approved make confirming to IS 733 and IS
1285 , member size with shutters of
horizontal member , vertical member
Confirming to IS733 and IS 1285 fixed with
rawl plug abd screws or fixing clips or with
expansion hold fasteners including
necessary filling up of gaps at junctions at
top bottom and sides with required PVC/
c 26 Neoprene felt, 8/12 mm toughened glass of 5401.70 Sq. M.
approved make etc. Aluminum sections
shall be smooth, rust free, straight.mitred
and jointed mechanically wherever required
including Door Hardware such as cleat
angles aluminum snap beading for glazing
/paneling, CP Brass/ Stainless steel screws,
Stoppers, heavy duty floor hing, S.S.
Hinges, aldrop , Locking system, heavy
duty Floor Springs, Pivot and fixtures and
transparent silicon sealant glass fixing to
frame as per details all complete as per
architectural drawings and the direction of
Engineer in Charge. rate incl. all type of
alumnium sections for doors as per the
detail Architectural dwg.
Providing and fixing standared extruded of
alluminium section of size 63 mm x
mm x 1.2mm (Section:2434, @
50 a 12 Wt.0.643Kg/mt ) with colour anodized 1163.92 Sq. M.
alluminium frame for ventilation with 5 mm
thick frosted glass as details etc complete
for Ventilation
Providing and fixing standared extruded of
alluminium section of size 63.50 x 38.10 x
1.95 mm ( Section no: 4605, @Wt 1.094 Kg
50 b 20 / Rmt with colour anodized alluminium 1509.90 Sq. M.
frame with 5 mm thick transparent bronze
colour tinted float glass as details etc
complete for Fix window.
Providing Fixing 1.2 mm thick Alluminium
Section Partition -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
Having Size of Section of 2.1/2 x 1.1/2 with
4 mm Compact Sheet / 5 mm thick Glass
Fixing with 4 mm thick EPDM Rubber etc.
Complete as per Direction of Consultant /
Providing Fixing 1.2 mm thick Alluminium
Section Partition Door -Fully Glazed / Partly
Panelled Partly Glazed / Fully Panelled
frame Having Size of Section of 2 .1/2 x
.1/2 and Door Section Having Size of Tips
Vertical 1 .3/4 x 1 .3/4, Top Rail 4 x
50d 13 .3/4, Middle Rail 1 .3/4 x 1 .3/4, Bottom rail 4061.77 Sq.mtr.
4 x 1 .3/4 with 4 mm Compact Sheet /
mm thick Glass Fixing with 4 mm thick
EPDM Rubber Including Lock, Handle,
Door Closer, Door Stoper, Stopper etc
Complete as per Direction of Consultant /
Providing and fixing Structural Glazing with
using the 17 Micron anodised of approved
colour alluminium section as transium,
mullium of size 63mm x 38mm x 2 mm with
using 6 mm thick reflective structural glass
of approved make, colour / Tinted,
toughned and shade and fixed with silicone
sealant and spacer tap and at corner sealed
neoprene foam dust and Air sealed gasket
mirred including scaffolding, cleaning of
glass etc.complete at all heights anf lifts
with all necessary fitting and fixtures,
anchore fasteners, necessary M.S. or
Aluminium brackets, suitable design for
openable or sliding window as per
Architectural drawing and as directed by
Engineer-in-charge. Grooves between the
glasses to be filled with sealant of Dow
corning - structural sealant 995, weather
sealant 789. The entire facade should be
water proof. The mullions are to be
connected to bracket by SS-304 nut bolts.
Measurement shall be given as per actual
execution of the work. (Rate are included
providing & fixing of MS structure steel work
wherever Required)
Providing and fixing wall acoustical paneling
Fixing with Sound Strut screw fixed
horizontal/vertical to wall at every 600mm
c/c. Metal cleat can be fixed on top edges of
Sound Strut Ceiling Section 55 fixed directly
by stamping to the CS55 and Intermediate
Channel-91 which is screw fixed directly to
the wall where ever required and using
Rock wool between framing and panel with
technical specification of 50 Kg Density and
50MM thick and above CS55 fixing
aluminum channel with clip and fixing
ecotone Slato Acoustic Panel make Slats L-
16 of size 128mm x 2430 mm x 16mm thick
up to 2400mm high as per the following
51b 647 specification :-Slats L-16- 2mm @16mm, 32 4376.53 Sqmt
x 128 x 2430 mm high E1 grade Pine wood
base Medium Density Fiber acoustic boards
with Tongue & Groove Edge,2mm slot
perforation @ 16mm centre, slates
perforations, The acoustic should be
furnished with a Black absorbent felt
backing with an airflow resistance of 330-
460 Ns/m³ (DIN 53887),wood practical
core,NRC : should be Up to 0.75,should
meet the safety requirements of EN
The colour of panel as approved by
Architect and as specified including all
accessories, material &labour complete as
directed by Architect / Engineer – in –
Design supply & installation of suspended
Spider Glazing system designed to
withstand the wind pressure as per IS
(Part-III). The Suspended System held with
Spider Fittings of SS-316 Grade Steel of
approved manufacturer with glass panel
having 12 mm thick clear toughened glass
held together with SS- 316 Grade Stainless
steel Spider & bolt assembly with laminated
glass fins 21 mm thick. The Glass fins and
glass panel assembly shall be connected to
Slab/ beams by means of SS- 316 Grade
stainless steel brackets & Anchor bolts and
at the bottom using SS channel of
50x25x2mm using fastener & anchor bolts,
non staining weather sealants of approved
make, Teflon/ nylon bushes and separators
to prevent bi-metallic contacts, all complete
to perform as per specification and
approved drawings. The complete system
to be designed to accommodate thermal
expansion & seismic movements etc. The
joints between glass panels (6 to 8 mm)
and gaps at the perimeter & in U channel of
the assembly to be filled with non staining
weather sealant, so as to make the entire
system fully water proof & dust proof.
The rate shall include all design,
Engineering and shop drawing including
approval from structural designer, labour,
T&P, scaffolding, other incidental charges
including wastage, enabling temporary
services all fitting fixers nut bolts, washer,
Buffer plates, fastener, anchors, SS
channel laminated glass etc. all complete.
For the purpose of payment, actual
elevation area of Glazing including
thickness of joints and the portion of Glass
panel inside the SS channel shall be
Providing and fixing 12 mm thick
Toughened Glass Door with / Without Fix
Portion Including Floor Spring , Lock,
mm Long Door Handle, Nut Bolt, Clamp,
Connector and All accessaries as approved
by Engg. Incharge
Providing and fixing ISI marked 35 mm thick
flush door shutters conforming to IS :
(Part I) decorative type, core of block board
construction with frame of 1st class hard
wood and well matched teak 3 ply
veneering with vertical grains or cross
bands and face veneers on both faces of
shutters with 1.00 mm thick Decorative
Laminated Sheet on both faces of shutters
including ISI marked Stainless Steel butt
hinges, bright /matt finished 125 mm
Stainless Steel handles of approved quality
& make, ISI marked oxidised M.S. door
latches / Aldrop Conforming to IS:5930 with
necessary screws etc. complete as per
direction of Engg. incharge.
Providing wood work in frames of Doors,
windows cleare story windows and
b 170 othersimilar works wrought, framede and 602.04
fixed in position. (A) Indian Teak Wood
Providing and fixing 35 mm th. Shutters for
doors windows & clearstory windows incl.
wood frames as specified 12 cm. x 7cm.
53 size incl. anodised alluminium fixtures and
fastenings including primer coat of
approved quality and two coats of oil paint
a 3 Fully glazed 4788.50 Sq. M.
b 3 Fully panelled 5478.89 Sq. M.
c 3 Partly panelled and partly glazed 5133.69 Sq. M.
Providing and fixing FRP frame size 100x50
mm and 28mm thick FRP depress panel
shutter having extra reinforcement on sides
& edges in Gel coat finish. The core of the
shutter & frame is to be filed up with
injected fire retardant grade polyurethene
foam done in situ alongwith embedded
54 47 wooden pieces for stiffening & also taking 2354.22 Sq.M.
hinges & fintures. The whole FRP frame &
shutter is to be water proof weather proof,
termite proof & resistance to mild
acid/alkali. Rates are to be inclusive of S.S
hinges with necessary screws & alluminium
fixtures & fastenings & fastener sleeve.
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be
well repaired as per instructions.
a 1 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1 For Pipe 400 mm to 600 mm diameter 2232.14 No.
Making connection of galvanised Mild steel
distribution branch with galvanised mild
56 1 steel main 50mm to 80mm nominal bore by 600.08 No.
providing and fixing tee including cutting
and threading the pipes complete
Providing throating or plaster drip, grooves
57a 1500 and moulding to Wall , R.C.C. chajja and 41.25 Rmt
Providing & Laying cement vatta 10 cm x
cm in size quarter round in c.m. 1:1 (
57b 180 cement, 1 coarse sand) laid in one layers 23.45 Rmt
finishing with a floating of neat cement
watering etc complete as dire.
Carring out plinth treat ment to post
construction/ existing structure by spraying
chemical solution for termite control
treatment including labour and material
consist ment withI.S.I specification. Using
Chlordene and Chiorpur files 20EC. As Per
58 1200 6131_ paret- II Consentration Weight one 104.90 Sq.mt
percent is recommended i.e one litre 20EC
chemical emulsion with19 liter give1%
concrentration inclusive of one litre
chemical emulsion appication at the rate of
5 Litre chemical/ Sqm of surface is
recommended as per I.S
Carring out timber treatment to all wood
work including drilling holes and spraying oil
based chemical solution on surface of
timber work for termite control including
labour and material etc. complete. Using
Chlordene 20EC. As Per 6113_part III
59 10 Consentration Weight 1.00 percent is 54.98 Smt
recommended one litre chemical emulsion
dillute with 9 liter of kerosene precent
concentration. Total dillute concrentration
will be10litre inclusive of the litre chemical
emulsion application 0.75/Litre chemical per
one Sqmt printed two coat wood surface.
Paver Block Providing and laying shot
blasted Non - interlocking, Paver blocks of
specified thickness, size, grade of concrete
and colour machine made and blasting by
automatic shot blasting machine and high
density of as per approved sample of
approved make for footpath, parking areas,
service lanes,cross over and other areas as
mentioned in the drawing. Including
providing and laying 50 mm thick averave
bedding layer of coarse sand below paver
block as per required grading and
specification. Laid paver block shall be
mechanically compacted. The work of the
paving blocks shall be executed in line and
60 200 level by skilled mason of flooring work only. 1150.59 Sq.mt.
Small size of paver block with same
specification shall be used at residue or at
end. It should be laid in such a way that the
no cutting of the paver block to be
necessary. If cutting of paver block shall be
required , than cut by machine only and
laying to be done by skilled flooring mason.
The finished surface of the paver block shall
have coarse sand Texture Finish. Pave
blocks shall be compacted and shall be re-
laid if necessary. Actual laid area shall be
measured and paid without any wastage.
(A) 80 mm thick M-35 grade Grey Paver
block of size 200mm x 200mm. As per
Providing and fixing pre-cast concrete kerb
stone of gray cement based concrete block
30cm length,30cm height and 15cm thick of
61 350 M250 grade concret as per approved 358.06 R.mt.
design and including excavation for fixing in
proper line and level,filling the joint with C:M
1:3 (1cement:3fine sand) etc complete.
Providing and fixing double action hydraulic
floor spring of approved brand and
manufacture conforming to IS :
having brand logo embossed on the body /
plate with double spring mechanism and
door weight upto 125 kg, for doors,
including cost of cutting floors, embedding
in floors as required and making good the
same matching to the existing floor finishing
and cover plates with brass pivot and single
piece M.S. sheet outer box with slide plate
etc. complete as per the direction of
Engineer-in-charge. With stainless steel
cover plate minimum 1.25 mm thickness
Providing and fixing aluminium extruded
section body tubular type universal
hydraulic door closer (having brand logo
with ISi, IS : 3564, embossed on the body,
door weight upto 36 kg to 80 kg and door
width from 701 mm to 1200 mm), with
double speed adjustment with necessary
accessories and screws etc. complete.
Designing, fabricating, testing, installing and
fixing in position Curtain Wall with
Aluminium Composite Panel Cladding, with
open grooves for linear as well as
curvilinear portions of the building , for all
heights and all levels etc. including:
(a) Structural analysis & design and
preparation of shop drawings for pressure
equalisation or rain screen principle as
required, proper drainage of water to make
it watertight including checking of all the
structural and functional design.
(b) Providing, fabricating and supplying and
fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of
approved shades made out of 4mm thick
aluminium composite panel material
consisting of 3mm thick FR grade mineral
core sandwiched between two Aluminium
sheets (each 0.5mm thick). The aluminium
composite panel cladding sheet shall be coil
coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating
of approved colour andshade on face #
and polymer (Service) coating on face #
as specified using stainless steel screws,
nuts, bolts, washers, cleats, weather
silicone sealant, backer rods etc.
(c) The fastening brackets of Aluminium
alloy 6005 T5 / MS with Hot Dip Galvanised
with serrations and serrated washers to
arrest the wind load movement, fasteners,
SS 316 Pins and anchor bolts of approved
make in SS 316, Nylon separators to
prevent bi-metallic contacts all complete
required to perform as per specification and
drawing The item includes cost of all
material & labour component, the cost of all
mock ups at site, cost of all samples of the
individual components for testing in an
approved laboratory, field tests on the
assembled working curtain wall with
aluminium composite panel cladding,
cleaning and protection of the curtain wall
with aluminium composite panel cladding till
the handing over of the building for
occupation. Base frame work cost for ACP
cladding is included in this item rate. The
Contractor shall provide curtain wall with
aluminium composite panel cladding,
having all the performance characteristics
all complete , as per the Architectural
drawings, as per item description, as
specified, as per the approved shop
drawings and as directed by the Engineer-
in-Charge. However, for the purpose of
payment, only the actual area on the
external face of the curtain wall with
Aluminum Composite Panel Cladding
(including width of groove) shall be
measured in sqm. up to two decimal places.
Providing and Fixing Box type metal letters
forming composite box made from 1mm
thick stainless steel plate of grade
having brush finish of following font size to
64 be fixed at Main Gate in english and or
Gujrati and including fixing charges. etc.
complete as per direction of Engg.
incharge. for Payment Purpose Height of
Letter will be measured.
a 960 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made out of
2mm thick s.s. plate grade 304, including
making necessary design as per Architect
dwg. Through laser cutting including
connection to the R.C.C./Masonary with
necessary frame,anchor fastnuts,M.S.Plate
etc. complete as per direction of Engg.
Providing and Fixing Sinage - internal and
external signage boards with Vinyle Text on
65b 7000 ACP sheet / 2 mm th. S.S. Plate etc. 9.38 Sq.Inch
complete as per direction of Engg.
Providing and fixing retro Reflective Hi
Intensity Micro Prismatic Grade Board using
2mm Aluminum / 4mm ACP, angle iron 75 x
75 x 6mm. Descaling and degreasing the
board as per requirement using epoxy
reflactive process by screen painting as
directed etc. complete including
transporting and fixing in C.C. 1:2:4 with
65c 8 necessary excavation curing etc. complete 7535.31 Sq.mtr.
as per I.R.C. 67-2012 design. A warranty
for 7 years for the Retro reflective sheeting
from original manufacturer & a certified
copy of 3 year outdoor exposure test report
from third party test lab for the product
offered shall be submitted by contractor.
(B)Class B Type-4(MDR/ODR) retro
reflective sheeting
Road marking with hot applied
thermoplastic paints with reflectorising glass
beads on bitumin surface providing and
laying a hot applied thermoplastic
compound 2.5 mm thick including
reflectorising glass beads @ 250gms per
sqm area, thickness of 2.5mm is excluding
of surface applied glass beds as per
IRC:35-2015. The finished surface to be
level, uniform and free from streaks and
holes. zebra patta /bump patta lane/center
line/ edge line/cut patta. The white color
marking should provide liminance
coefficinet on cemend road shalll be min
130 mcd/m2/lux and Asphalt road shall be
min 100 mcd/m2/lux during the service life
during the day time. The marking should
meet the performance criteria for night time
reflectivity, wet reflectivity and skid
resistance as mentioned in the section-15
of IRC 352015. Warranty for the Retro
reflectivity should be two years.
CAT EYE/Pavement Marker(MNC two nail)
made out of acrylic StreneAcrylonitrile or hi-
impact poly Steren fitted with moulded of
metheacrylate(MNC)reflector cube corner
reflector design,filled with tightly adhering
pooting compound as per ASTMD-788 size
11.5x7x1.60 cms or 10x10x1.75 cms
provided with bituminous adhesive in
sufficient quantity with each unit fixing with
two shrank .Reflector on both side.Co
efficient of lumination as per specification
and compressive strenth 13 tones at
degree centigrade etc.B) Double side
Providing and fixing eco-friendly light weight
calcium silicate false ceiling tiles having T
egular edge & 15mm Thick Densified edges
on the Tile Periphery for Extra Strength The
Light weight calcium silicate ceiling tiles
shall have, light reflection 85% non-
combustible as per B.S.476 part IV, 100%
humidity resistance and also having thermal
conductivity 0.043° w/m KC. for the best
thermal Insulation.
The Light weight calcium Silicate tile shall
be of approved texture Fine fissured/
Spintone/ Cosmos having NRC value of
& Globe having NRC value of 0.75 NRC or
equivalent of size 595X595 mm to be laid
on true horizontal level suspended inter
locking metal grid of hot dipped galvanized
steel sections (galvanizing @ 120 grams
per sqm including bothside) consisting of
main ‘T’ runner suitably spaced at joints to
get required length and size of 24X38 mm
made from 0.30 mm thick (minimum) sheet,
1200 mm centre to centre, and cross ‘T’ of
size 24X28 mm made out of 0.33 mm
(Minimum) sheet spaced 1200 mm along
spaced between main ‘T’ at 600 mm centre
to centre to form a grid of 1200X600mm
and secondary cross ’T’ of length 600mm
and size 24x28mm made of 0.30 mm thick
(Minimum) sheet to be interlocked at middle
of the 1200X600mm panel to form grid of
size 600X600mm resting on periphery walls
/ partitions on a perimeter wall angle pre-
coated steel of size (24X24X3000mm made
of 0.40mm thick (minimum)
sheet with the help of rawl plugs at 450mm
centre to centre with 25mm long dry wall
screws @ 230mm interval and laying 15mm
thick Densified edges light weight calcium
silicate ceiling tiles of approved texture
(Fine Fissured/ Cosmos/Spintone) in the
grid including, cutting /making opening for
services like diffusers, grills, light fittings,
fixtures, smoke detectors etc., wherever
required, Main ‘T’ runners to be suspended
from ceiling using G.I. slotted cleats of size
25X35X1.6mm fixed to ceiling with 12.5mm
dia and 50mm long dash fasteners, 4mm
G.I. adjustable rods with galvanized steel
level clips of size 85X30X0.8mm, spaced at
1200mm centre to centre long main ‘T’
bottom exposed with 24mm of all T-sections
shall be pre-painted with polyester baked
paint, for all heights,
, as per specifications, drawings and as
directed by engineer-incharge.Note:- Only
calcium silicate false ceiling area will be
measured from wall to wall. No deduction
shall be made for exposed frames/ opening
(cut outs) having area less than 0.30 sqm.
The calcium silicate ceiling tiles shall have
NRC. Value of 0.50 (Minimum) for Fine
fissured/ Spintone/ Cosmos and 0.75 NRC
for Globe, light reflection 85%
noncombustible as per B.S. 476 part IV,
100% humidity resistance and also having
thermal conductivity. 0.043° w/m KC.for the
best thermal Insulation
Providing and fixing single layer water proof
66b 755 gypusm board 12.5 mm thick of the make 600.94 Sq.mt.
New good Group Co.Ltd. or equivalent &
New good Group Co.Ltd. company sections
using water proof board of size 1220 mm x
1830 mm x 8.0 mm suspended by G.I
suspender of size 25 mm x 3 mm with
intermediate channel of size 18mm x40mm
x0.80mm at 1220 mm center to center
ceiling section of size 40mmx 35mmx
0.55mm at 457 mm center to center and
perimetre chanel A of size 20mm x 27mm x
30mm x 0.50mm at edges & drops including
paper taps and sofit cleat, anchor fastener,
scoch bolt connecting cleat joining
compound top coat on ceiling including
making necessary opening for light fitting,
diffuser etc. complete as per detail drawing
Providing and Fixing 6 mm thick Lexan
Polycarbonate multi wall roofing sheet fixed
67 10 with hilti screw and rubber silicon sealer 1427.62 sq.mt.
and alluminium strip of size 50 x 3 mm etc
complete as directed by Engineer in charge
Providing and supplying ISI Standard RCC
pipes (of sulphate resisting Cement )in
standard lengths of following class and
diameter suitable for rubber ring joints
68 (socket and spigot) including all
taxes,insurance, transportation,treight
charges,octroi,inspection charges,
loading,unloading, conveyance to
departmental stores, stacking etc. comple
Class NP3 Test pressure 0.7 Kg/Sq.Cm
a 200 300 mm Diameter 755.00 Rmt
b 25 450 mm Diameter 1361.00 Rmt
Lowering, laying and jointing R.C.C. pipes
in C.M.1:1 1/2 of following diameters in
proper position , grade and alignment at all
68 level as directed by Engineer-in- charge
including conveyance from stone to site of
work, labour giving hydraulic testing as per
c 200 300 mm Diameter 119.00 Rmt
d 25 450 mm Diameter 171.00 Rmt
Constructing Bombay Pattern Type Catch
Pit of size 0.60 x 0.60 depth up to 1 mt
including excavation, B.B.C.C. (1:5:10),
cms thick brick maso. wall in the prop. of
69 20 CM (1:6) with 40 mm thick IPS flooring in 3125.00 No
the prop M15 at bottom and 15 mm thick
cement plaster inside the catch pit in the
proportion of CM (1:3) with out jali etc.
comp. as directed.
CatchPit Jali Fixing P/F FRC catch pit jali
with frame 600mm x 600mm clear opening
etc. comp.. As directed by engineer in
PERCOLATION WELL
Drilling of pilot bore hole in Alluvial Strata by
71 120 direct Rotary Rig of 250 mm. 694.64 Rmt
72 120 Reaming 400 mm 212.50 Rmt
73 1 Electro Logging charges with carting 16071.43 Job
Providing and Installing 200 mm dia
74 60 IS:12818 upvc Casing Pipe "CM" class 1193.75 Rmt
Providing and Installing 200 mm dia
75 1 IS:12818 upvc End Cap, with Air Vent cowl 669.64 Set
200 mm dia Regular with 1.5 mm sloted
size cage type trapezoidal shape wire
wound little carbon galvanized screen
confirming to IS:8110
77 10 Supply of Pea sized Gravel 2029.46 Cmt
78 1 Air Vent of 50 mm Bend 401.79 Unit
Lowering and Removing of Dropline up to
79 120 Depth 186 mtr. 147.32 Rmt
80 1 Air Compressor 60 CFM/150 PSI 22205.36 Ls
Estimate For Civil Work With Percolation
Electrical Work
I. No. Qty Items Unit Rate Per Amount
Electrical Work Estimate
1 INTERNAL WIRING
Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand
copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type
switch / bell push & accessories and earth
continuity of following type, erected on
PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
225 accessories erected concealed in 505.05 Pt
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (Green) both are of
.ISI marked 1.1 KV Grade ZHFR/HRFR
PVC insulated multi strand copper wires up
to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and
hum free EME four or more step type
electronic fan regulator with separately
mounted and accessories with earth
continuity of following type erected on PVC
/ Metallic/Wooden box, single mounting
base frame covered with
textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe
erected. with necessary ceiling rose /
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
Point wiring for secondary light point with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi strand
copper wires, in below type of pipe to be
erected complete with earth continuity and
necessary connection with primary light with
accessories erected on Metal / PVC /
wooden box covered covered with
appropriate front plate modules erected on /
in wall / ceiling for open / concealed wiring.
with necessary Lamp holder / ceiling rose /
H.D.Connector as directed.as per pipe
erected with following type of accessories.
Note:- Maximum up to 6 mtrs length,
excess will be considered as Mains for
Secondary Point.
(f) with medium class Rigid PVC pipe and
260 accessories erected concealed in 174.30 Pt
wall/ceiling complete
Point wiring for Individual Plug with & earth
wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires up to
mtr length, in below type of pipe erected
1.4 complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden
box covered with appropriate front plate
modules erected on / in wall / ceiling as per
pipe erected with following type of
[I] For 6A Plug and 6 a switch with 2-1.5
1.4.1 30 sq.mm Cu. Wire from nearby 530.25 Pt
switchboard/mcb db board
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
[II] For 16A Plug and 16 amp switch with 2-
1.4.2 25 2.5 sq.mm Cu. Wire from mcb db board. 774.90 Pt
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
[III] For 16A Plug and 16 amp switch with
1.4.3 20 2-4 sq.mm Cu. Wire with 2.5 sq.mm ( 906.15 Pt
green) earthing wire from mcb d b board.
(f) with medium class Rigid PVC pipe and
accessories erected concealed in
wall/ceiling complete
Point wiring for on board Looped Plug with
6A Modular type switch & 5 pin socket
erected on PVC / Metallic/Wooden box,
1.5 65 single mounting base frame covered with 255.00 Pt
textured / metallic/white front plate modules
erected on / in wall / ceiling with following
type accessories
Point wiring for Two Way Controlled Light
Point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of .ISI marked
KV grade ZHFR/HRFR PVC insulated multi
strand copper wires erected in below type
of pipe with 6A Modular type switches and
1.6 following type of accessories erected on
PVC / Metallic/Wooden box, single
mounting base frame covered with textured
/ metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected.
with necessary batten/angle holder or
ceiling rose or H.D.Connector as directed.
(f) with medium class Rigid PVC pipe and
6 accessories erected concealed in 627.90 Pt
wall/ceiling complete
Providing following type of Modular Type
Accessories mounted with PVC /
metallic/Wooden box, single mounting base
1.7 frame covered with textured / metallic/white
front plate , modules erected with
necessary connections as per site situation
directed by Engineer In charge.
1.7.1 5 (1)One No. SP 6 Amp. 150.00 E.a.
1.7.2 5 (2) One No 5 pin plug 150.00 E.a.
1.7.3 80 (7) Blank Plate Single 25.00 E.a.
1.7.4 1 (8) Computer RJ-45 socket 159.00 E.a.
1.7.5 15 (9) 16 Amp. SP one way switch 179.00 E.a.
1.7.6 15 (10) 6/16Amp. Universal socket 198.00 E.a.
(13) 6A/10A/16A/20A/25A/32A Single pole
1.7.7 4 Modular MCB Switch 307.00 E.a.
(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double
1.7.8 4 Pole Modular MCB Switch 406.00 E.a.
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
1.8 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in
approved manner as directed
Providing & erecting PVC Corrugated
Flexible Conduit with required nos. of
1.9 coupling, PVC bushes, Check-nuts etc.
complete of following sizes.
providing and erecting Mains with ISI
marked electrolyte stranded copper
conductor, Non PVC Zero Halogen free fire
retardant insulated copper conductor,
insulated wire (HRFR) conforms to IS-694,
erected in existing pipe with 1.5sq. mm
copper conductor of same specifications for
earth continuity of following size.
In Existing medium class Rigid PVC pipe
and accessories
1.10.4 25 (b) 2 wire 6 sq. mm 139.00 Mtr
providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following
1.11 type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green
colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and
1.11.1 30 (h) 4 wire 6 sq. mm 258.00 Mtr
(i) 4 wire 10 sq. mm
(use earth wire of 4 sq.mm )
providing and erecting Mains with ISI
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS
1.12 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel,
relays, power switchgears, motor starters &
control wiring) with required size of copper
lugs, nuts and bolts if required.
1.12.1 20 (e) One wire 6.00 sq. mm 56.00 Mtr
1.12.2 20 (f) One wire 10.00 sq. mm 91.00 Mtr
1.12.3 15 (g) One wire 16.00 sq. mm 141.00 Mtr
1.12.4 15 (h) One wire 25.00 sq. mm 234.00 Mtr
1.12.5 15 (i) One wire 35.00 sq. mm 298.00 Mtr
1.12.6 50 (k) One wire 70.00 sq. mm 663.00 Mtr
Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kv
1.13 grade ISI marked copper wires of following
size to be erected as directed.
1.13.1 140 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
1.13.2 80 h) 2.50 Sq.mm 3 core round PVC sheathed 77.00 Mtr
1.13.3 15 k) 4.00Sq.mm 4 core round PVC sheathed 175.00 Mtr
Supplying & erecting M.S. Box having
Gauge painted with red oxide or Heavy
1.14 duty PVC box erected flushed on wall or
concealed in wall with necessary plastering
& finishing as directed of following size.
Supplying and laying UPVC cable trunking
system comprising unplasticised polyvinyl,
chloride rigid material with ignition free and
flame proof confirming BS with necessary
end caps Internal and external bend, flat
bends, coupler, tee etc..All necessary
accessories and measuring of following
1.15.1 5 (2) 100 mm x 50 mm trunking 424.00 Mtr
(4)100 mm x 50 mm trunking with TWIN
1.15.2 5 compartment With clip in divider 1309.00 Mtr
Supply & installation of surface mounted U
PVC snap-on adaptable trunking raceways,
fabricated out of U-PVC to Off-White or
approved shade as per IS 733 of thickness
1.16 2.0mm for the base and sides with all
accessories like removable covers, joints
,height spacer,angles complete with
necessary bends, suitable sized junction
boxes and tees etc, Complete.
(a)Size: 50x80mm PVC Raceways for
5 Power & Data with 2 compartments above 1052.00 Mtr
specifications.
Supply & installation of modular type
accessories for U PVC snap-on adaptable
1.17 trunking/Pop up Box with required items
erected with necessary connection. As
desired by Engineer In charge
1.17.1 1 i) 6 A SP 1 Way Switch 204.00 No
1.17.2 1 ii) 16A SP 1 Way Switch 351.00 No
1.17.3 1 iv) 6A universal socket shuttered 347.00 No
1.17.4 1 iv) 6/16 A universal socket shuttered 458.00 No
1.17.5 1 vi) Cat-6 LAN Socket 561.00 No
SUB - TOTAL OF INTERNAL WIRING
2 Switchgears , Panels , MCBDBs & MCBs
Design, fabrication, assembling, supply,
installation, testing and commissioning of
cubicle type, wall / Floor mounted LT panel
suitable for 415 V 3 phase, 4 wire 50 Hz AC
supply system fabricated in
compartmentised design from CRCA sheet
steel of 2 mm thick for frame work ,Doors
and partitions IP 42 and covers,3 mm thick
for gland plates i/c cleaning and finishing
complete 9 tank process in house facility for
powder coating in approved shade,
extendable type FP aluminium alloy
busbars of high condectivity, DMC/SMC
busbar supports, entire panel shall have a
common copper earthbar of size 25mm X
mm / 50 x 6mm al earth bar at the rear with
2 Nos. earth studs, solid connection from
main busbar to switchgears with require
size of aluminium busbar & control wiring
with 1.5 sqmm FRLS insulated copper
conductor cable, cable alleys, cable gland
plates i/c accessrories as per specification
and providing switchgears, metering
instruments etc. for following
panel.G.A.Drawing to be approved by EIC
or consultant. ( Outgoing connectors must
be nut-bolt type. Outgoing mains for 63Amp
MCBs must be of 4 x 16sqmm cu flexible
wires).Incomers Mains for MCBs shall be
always from the busbars.
( a ) Providing cable clamps / supports
within distribution boards cable alley.
( b ) All hinged door shall be earthed
through 2.5 sq mm tinned b raided copper
( c ) Pad locking of MCCB’s handles in
“OFF” Position.
( d ) All the C.T.s should be auto short link
( e ) All the MCCB's should be with rotary
( f ) All incoming and outgoing air circuit
breakers shall be placed on middle portion
of the vertical in single tier formation.
( g ) Any descripancy found in SLD & Boq
it should be brought in the notice of the
client / consultant, and the decision will be
taken final by Client / consultant.
Providing and erecting Approved make
Four pole moulded case circuit breaker
having breaking capacity ICU of 50 K.A.
and above at 415 V having normal current
rating up to 630A. with variable thermal &
magnetic release suitable to work on
A.C.supply 50 c/s. with all internal
connections, spreader tinned copper &
complete erected in existing 16 G.M.S.
2 ICS=100% of ICU only 37658.25 No
Providing and erecting Approved make
Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. and
above at 415 V . having normal current
rating 250A. with variable thermal &
magnetic release suitable to work on
A.C.supply 50 c/s. with all internal
connections, spreader tinned copper &
complete erected in existing 16 G.M.S.
4 ICS=100% of ICU only 20739.00 No
Providing and erecting Approved make
Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at
415 V. having Normal current rating
2.3 200A.with variable Thermal & magnetic
release suitable to work on A.C.supply
c/s. with all internal connections, spreader
tinned copper & complete erected in
existing 16 G.M.S.housing
3 ICS=100% of ICU only 16061.00 No
Providing and erecting Approved make
2.4 Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. at
415 V. having normal current rating 125A.
with Fixed thermal & magnetic release
suitable to work on A.C.supply 50 c/s. with
all internal connections, spreader tinned
copper & complete erected in existing
G.M.S. housing.
5 ICS=100% of ICU only 7976.00 No
Providing and erecting Approved make
Four pole moulded case circuit breaker
having breaking capacity ICU of 25 KA. at
415 V,having normal current rating up to
2.5 A to 100A. with Fixed thermal & magnetic
release suitable to work on A.C. supply
c/s. with all internal connections, spreader
tinned copper & complete erected in
existing 16 G.M.S. housing.
6 ICS=100% of ICU only 6112.00 No
Providing and erecting Approved make
Three pole moulded case circuit breaker
having breaking capacity/strength ICU of
K.A. and above at 415 V. having Normal
current rating 200A.with variable Thermal &
magnetic release suitable to work on
A.C.supply 50 c/s. with all internal
connections, spreader tinned copper &
complete erected in existing 16 G.M.S.
1 ICS=100% of ICU only 15421.00 No
providing and erecting Approved make
Earth fault Relay suitable to mount with
inter connection suitable to following size of
moulded case circuit breaker having CT
ratio & MCCB rating as following along with
shunt trip 220V AC. with all internal
connections & complete erected in existing
Fabricating the box type items made from
M.S. Sheet with A.I. supports, wings, doors,
handles other hardware materials as per
requirement design with finishing by three
tank powder coating processed inside and
outside painted, erected as directed
including minor civil work. to install above
providing and erecting Miniature circuit
breaker single pole 0.5A to 2A system and
2.9 80 having breaking capacity 10 KA to be 268.00 No
erected in existing box. confirming to IS
8828/1996 with ISI Mark
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996
2.11 Providing & erecting 240 V MCB double
pole switch for motor & inductive load (C
Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having
following capacity
Providing & erecting 415 V MCB Four Pole
for Motor & Inductive Load (C Curve)
2.12 having 10KA breaking capacity & confirms
to IS :8828 in existing box having following
Providing & erecting 415 V MCB three Pole
for Motor & Inductive Load (C Curve)
2.13 having 10KA breaking capacity & confirms
to IS :8828 in existing box having following
Providing and erecting Approved make
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for
2.14 operation on single phase 240 V,50Hz.
having characteristic of quick action &
tripping with all advance feature & do not
incorporate any electronic component. for
following Max. rating erected as directed
8 (ii) 40Amps. DP 2213.00 No
Providing and erecting following additional
2.15 parts for panel mounting MCCBs
(A)Extended operating rotary handle with
pad lock with three position trip,off,on
suitable for 25A to 250 A panel mounting
(B)Extended operating rotary handle with
pad lock with three position trip,off,on
suitable for 400A to 630 A panel mounting
Supplying and erecting approved make
panel mounting type Digital Voltmeter
having 3 digits LED display, 0 to 750 AC
Volts range erected on existing panel
board with all connection, wiring etc .with
manufacturers calibration certificate.
Supplying and erecting approved make
panel mounting type Digital Ammeter
having 3 digits LED display, external CT
operated, calibrated for 0 to 1000 Amps
suitable to operate on 500 Volt AC , erected
on existing panel board with all connection,
wiring etc .with manufacturers calibration
Supplying and erecting Ammeter /
Voltmeter selector switch for 3 phase AC
Supply 500 V on existing panel board with
necessary connections.
Providing & erecting L.T. Current
Transformer with bar primary 50/5 to 1000/5
ratio 15 VA burden erected in existing
CRCA box duly secured with insulating
materials connected to the meter
Supplying & erecting approved make Power
Factor Meter 150mm dia flush/projection
type/ balanced & unbalanced load to work
2.20. 4 with appropriately provided CT’s 100/5A to 5052.00 No
400/5A ratio & other accessories complete
erected in M.S. box & connected to the
circuit by means of PVC copper Core leads.
Supplying and erecting approved make
suitable panel indicator LED type lamp, lens
cover, complete erected with necessary
Providing and erecting metallic vitrified
danger notice board as per language
2.22 16 suggested by engineer incharge for 69.00 No
MEDIUM VOLTAGE installation to be
erected as per IS-2551.
Providing and erecting required size
Aluminium strip for earthing of H.T. , OCB /
ACB / Transformer, LT panel board, Motors
etc. using copper clamp.
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc.
using copper clamp.
providng and erecting Approved make
energy meter 3 phase 4 wire unbalanced
load 500 V. 5 to 10A complete erected as
directed with necessary earth wire.Class-1
Providing , erecting , fabricating the M.S.
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding,
grinding & finishing duly painted with one
coat of red oxide with erection on site as
per direction of engineer in charge with
necessary grouting, cementing, plastering &
finishing complete.
Supplying and erecting triple pole & neutral
440V/ 500V panel mounting Aluminium
Busbars with four equal Nos. of bus having
current density not more than 0.8 Amp. /
sq.mm (Rated current / cross section area)
2.27 duly wrapped with colour insulating tape for
phase sequence of following current
carrying capacity, erected with necessary
bus bar supports /insulators, main cable
socket to each busbar,erected in existing
cubical panel with necessary connections.
2.27.1 22 (A) Suitable for 100 Amp. Capacity 654.00 RnMtr
2.27.2 12 (B) Suitable for 200 Amp. Capacity 1027.00 RnMtr
2.27.3 10 (C) Suitable for 300 Amp. Capacity 1455.00 RnMtr
2.27.4 10 (F) Suitable for 800 Amp. capacity 6179.00 RnMtr
Supplying and erecting triple pole & neutral
440V / 500V panel mounting Copper
Busbars with four equal Nos. of electrolyte
bus having current density not more than
1.6 Amp. / sq.mm (Rated current / cross
section area) duly wrapped with colour
insulating tape for phase sequence of
following current carrying capacity, erected
with necessary bus bar supports /insulators,
main cable socket to each bar, erected in
existing cubical panel with necessary
4 (A) Suitable for 100 Amp. Capacity 1942.00 RnMtr
Providing & erecting weather proof, dust &
vermin proof, floor mounted front operated
indoor type cubical panel board necessary
IP-42 and above protection as per approval
from engineer incharge made from 14 SWG
thick CRC M.S. sheet for outer body &
doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary
accesories , supporting angles/ flats
channel including cutting, bending, drilling,
welding, riveting with internal partitions &
cable alley as per requirements &
instruction of engineer-in-charge with
supplied switch gears, BUSBARS, suitable
size of inter connecting PVC copper wire /
copper-aluminium strips, rubber grommets,
rib, bakelite control fuses/MCB for
measuring instruments, earth bus & earth
bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with
locking arrangement and rubber
gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder
(The rates excludes the cost of switchgears,
bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding
base beams) The panel shall be supplied
with following approved manufacturers with
following size.
(B) The standard companies switch gear
shall be used and only manufacturers at
CPRI approved factory
25 (i) with 350mm depth 14755.00 Sqmtr
Providing & erecting weather proof, dust &
vermin proof, floor mounted front operated
outdoor type double door cubical panel
board necessary IP-54 and above
protection as per approval from engineer
incharge made from 14 SWG thick CRC
M.S. sheet for outer body & doors, 16 SWG
thick CRC M.S.sheet for internal partitions
with necessary accesories , supporting
angles/ flats channel including cutting,
bending, drilling, welding, riveting with
internal partitions & cable alley as per
requirements & instruction of engineer-in-
charge with erection of
supplied switch gears, BUSBARS, suitable
size of inter connecting PVC copper wire /
copper-aluminium strips, rubber grommets,
rib, bakelite control fuses/MCB for
measuring instruments, earth bus & earth
bolts, foundation flange - bolts-base Plates,
sufficient nos. of hinged doors, handles with
locking arrangement and rubber
gasket,heavy duty end terminal
connection,danger notice board,necessary
ventilation,earthing strip complete. The
Panel shall be painted with epoxy powder
(The rates excludes the cost of switchgears,
bus bars, inter connecting mains & Copper
Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding
base beams) The panel shall be supplied
with following approved manufacturers with
following size.
(B) The standard companies switch gear
shall be used and only manufacturers at
CPRI approved factory
4 (i) with 350mm depth 16162.00 Sqmtr
Supplying & erecting XLPE(IS:7098)(I)-88
2.31 ISI unarmoured copper cable 1.1 KV grade
to be erected as directed of following size.
2.31.3 60 (L) 4 core 6 Sq. mm 361.00 Mtr
2.31.4 20 (C) 2 core 6 Sq. mm 202.00 Mtr
2.31.5 40 (B) 2 core 4 sq.mm 130.00 Mtr
providing and erecting Mains with ISI
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with
heat resistant PVC insulated conforms to IS
2.32 694, IEC - 227 erected in existing pipe of
following size (Specifically for control panel,
relays, power switchgears, motor starters &
control wiring) with required size of copper
lugs, nuts and bolts if required.
2.32.1 270 (a) One wire 1.00 sq. mm 12.00 Mtr
2.32.2 310 (b) One wire 1.50 sq. mm 17.00 Mtr
2.32.3 225 (c) One wire 2.50 sq. mm 27.00 Mtr
2.33 1 50KVAR APFC PANEL 141527.00 No
Design, Supplying, installing, testing of
factory fabricated ready made Three phase
APFC Panel Cubical Panel fabrication
should be type tested as per IEC
61439:1&2 Capacitor Duty Contactor for
switching as per following Steps Incomer
Switch of MCCB type Icu=Ics=50KA at
400/440 Volts, with OC, SC, internal earth
fault protection Incomer Switch of MCCB
type Icu=Ics=50KA at 400/440 Volts, with
OC, SC, internal earth fault
protection,Copper tinned insulated
Busbar,Cubical panel should be indoor type
with IP 43 and IK 10,Metalized
polypropylene film tye3-phase 550Volt
Capacitor,De tuning Reactor for each
capacitor,Panel having Short Circuit and
Overload protection,Each step Capacitor
having suitable MCB with Sc, OL, internal
earth fault relay,Each stage having Stage
Contactor (Capacitor load rating),PF
regulator master controller having suitable
steps with LCD display, Rs
Communication port, Indication LED Lamps
for main incomer and ON-OFF for each
capacitor bank,MS Chanel for Floor
mounting, Cable entry as per site
situation,Cooling fans for panel
Supplying & erecting approved make IP
grade Company fabricated Timer Panel of
following capacity for switch On-Off street
lights on time scheduling basis made from
16G CRCA sheet duly epoxy power painted
inside and outside with hinged doors and
locking arrangement consisting of suitable
size of 4 Pole MCB and 4 pole contactor
(cat-III)with analog time switch, auto manual
switch of same make and suitable input
and output Bakelite terminals and with door
earthing approved by Engineer in charge.
MCBDBs and MCBs
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996
Providing & erecting 240 V MCB double
pole switch for motor & inductive load (C
2.36 Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having
following capacity
Providing & erecting 415 V MCB Four Pole
2.37 for Motor & Inductive Load (C Curve)
having 10KA breaking capacity & confirms
to IS :8828 in existing box having following
Sheets steel powder coated enclosure
2.38 4 suitable for incorporating One/Two nos. 175.00 E.a.
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush /
surface mounted fitted with busbar, neutral
link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB
to house appropriate nos. of MCBs.(The
DBs should be used of same company of
MCB to be used) suitable for
(A) single phase incoming and horizontal
single phase outgoing
(b) sheet steel double door (IP-43)
2.39.1 4 (i)4 way ( concealed manner ) 747.60 E.a.
2.39.3 1 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.39.5 4 (iv)12 way ( concealed manner ) 1773.60 E.a.
(B) three phase incoming and single phase
2.40. horizontal type outgoing Per phase
isolation type (PPI)
(b) sheet steel double door
2.40.1 3 (i)4 way ( concealed manner ) 2779.20 E.a.
2.40.3 2 (ii)6 way ( concealed manner ) 3462.00 E.a.
2.40.5 9 (iii)8 way ( concealed manner ) 4054.80 E.a.
Supplying & erecting Sheet Steel powder
coated Cable end termination Box to be
mounted on Top or Bottom of the MCB
Distribution Box for housing/covering Extra
wires & Cables, suitable for following size of
(G) Three Phase 8 Way ( concealed
2.41.2 2 (F) Three Phase 8 Way 683.00 E.a.
providing and erecting Approved make
ELCBs / RCCBs conforming to IS:
and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and
suitable for operation on single phase
V,50Hz. having characteristic of quick
action & tripping with all advance feature &
do not incorporate any electronic
component. for following Max. rating
erected as directed
Providing and erecting Approved make
RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral
415V,50Hz. having characteristic of quick
action & tripping with all advance feature &
do not incorporate any electronic
component for following Max. rating
erected as directed.
Supplying & erecting approved make SMC
press moulded composite FRP. loop-in,
loop-out approx. 2mm thick box complete
with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting MCB
& hinged doors as per requirement having
locking arrangements with mounting clamp
with nuts, bolts & washers suitable for
erection on pole with cable clamps& earth
bolt of following size of box.
18 (F) 200mm x 180mm x 100mm [deep] 538.00 E.a.
Providing and erecting metallic vitrified
danger notice board as per language
2.45 20 suggested by engineer incharge for 69.00 E.a.
MEDIUM VOLTAGE installation to be
erected as per IS-2551.
Providing & erecting Medium Voltage
Danger Notice Board sticker as per
2.46 5 language suggested by engineer incharge 26.00 E.a.
of standard size as per IS-2551
SUB - TOTAL OF Switchgears , Panel
Follow IS code :3043 is the guideline for
Providing and erecting required size HOT
deep Galvanised iron strip for earthing of
3.1 300 H.T. , OCB/ ACB/ Transformer LT panel 77.00 KG
board, Motors etc. using proper clamp.
Providing and erecting required size Copper
strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc.
using copper clamp.
Providing and erecting Annealed bare
3.3 10 Copper wire 8 to 16 SWG. 787.00 KG
Providing and erecting HOT deep
3.4 90 Galvanised iron strip wire 8 to 16 SWG. 77.00 KG
Supplying & erecting earth pit of minimum
bore dia.150mm size approved make
Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of
3.5 corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm
having 200-250 Micron galvanising,
connection terminal dia of 12mm with
constant ohmic value surrounded by highly
conductive compound with high charge
dissipation suitable for following type of
applications with chamber and heavy duty
cover.(approved make OEM has to submit
test certificate) & having back filling
compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 W/ meter
testing as per IEC 62561-2017, Voltage
drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should
be capable to retain moisture for long time
Necessary test report must be submitted.
(a) For Electrical Installation up to 440V in
normal soil, Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of
(c) For Electrical Installation covering
Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer
System(like Automation, SCADA) i.e
independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of
Supply, installation,testing and
commissioning of Chemical Earthing with
UL Certified 17.2mm Dia. X 3000mm Long
254 Micron-Copper bonded M.S. Rod
manufactured as per IEC 62561-2 with
25Kg Bentonite powder plus " U " bolt rod
clamp complete with Lockable high
performence chamber suitable & tested for
5000T capacity with SS Hardware.or
SUB - TOTAL OF Earthing
CABLES, Cable Termination and cable
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Aluminium
4.1 conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench
/ pipe of following size of cables
(A-1) 3 1/2 core 35 Sq. mm (16 Sq. mm 1/2
(B) 3 1/2 core 50 Sq. mm (25 Sq.1/2 mm
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-
88 ISI armoured cable multistrand / Solid
Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
4.2.1 25 (a) 4 core 4 Sq. mm 116.00 Mtr
4.2.2 300 (b) 4 core 6 Sq. mm 125.00 Mtr
Providing and erecting XLPE (IS:7098)(I)-
88 ISI armoured cable multistrand
4.3 Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing
trench / pipe of following size of cables
4.3.2 80 (e) 4 core 25 Sq. mm 189.00 Mtr
Supplying & erecting XLPE(IS:7098)(I)-88
4.4 ISI unarmoured copper cable 1.1 KV grade
to be erected as directed of following size.
4.4.1 30 (G) 3 core 6 Sq. mm 290.00 Mtr
4.4.2 10 (H) 3 core 10 Sq. mm 439.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand / Solid
Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing
trench / pipe at road crossing or floor of
following size of cables.
4.5.2 55 (B) 4 core 4 Sq. mm 361.00 Mtr
4.5.3 790 (C) 4 core 6 Sq. mm 505.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench
/ pipe at road crossing or floor of following
size of cables.
140 (C) 4 core 10 Sq. mm 670.00 Mtr
Making trench in soft soil of suitable width
of 90 cm deep for laying cable or locating
4.7 280 the fault all over the run and back filling the 55.00 Mtr
same and making the surface as normal
Covering of cable with second class bricks
or cement tiles laid cover the cable
4.8 30 crosswise & also on both sides with 139.00 Mtr
covering of 7. 5 Cm. layer of sand above &
below cable (16 bricks per meter)
( A )Making trench in Hard Murrum / Tar
Road of suitable width of 90 cm or required
depth for laying any size of cable or locating
the fault all over the run and back filling the
same and making the surface as normal
(B) If additional machinery like hammer
driller or JCB use [Add]
Drilling the road without breaking the road
surface (Asphalt) for laying of cable for
4.11 feeding power supply by making up to
following size of holes at both ends
4.11.1 5 (A) Up to 100 mm bore dia 488.00 Mtr
4.11.2 5 (B) Up to 150 mm bore dia 610.00 Mtr
4.12 Supplying following size of Light duty “A”
Class G.I . Pipe & erecting as directed by
Engineer-in-charge.
20 (A) 25 mm dia 171.00 Mtr
Providing & laying. R.C.C. Hume pipe for
cable to be laid 90 cm. below ground across
4.13 the road crossing or on floor with necessary
material in an approved manner and
making the ground as per original.
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
4.14 necessary connecting accessories of same
material at required depth in existing trench
for laying of cable. below ground / road
surface for enclosing cable
4.14.1 90 (A)50 mm outer dia 62.00 Mtr
4.14.2 310 (B)63mm outer dia 73.00 Mtr
4.14.3 50 (C))90 mm outer dia 95.00 Mtr
4.14.4 40 (D)120 mm outer dia. 136.00 Mtr
Providing & laying approved make ISI
marked Rigid PVC pipe having 6Kg / cm2
(Class-3) to be erected at road crossing on
or floor as directed for laying of cable. The
pipes as following size of dia & weight per
4.15.1 15 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124.00 Mtr
4.15.2 10 (F) 110 mm inner Dia. (11.63 Kg/6 RMT) 234.00 Mtr
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
4.16 insulated armoured cable complete with out
going tails, insulating tape etc for following
size of cables.
Providing and, fixing heavy duty flange type
brass double compression type cable
gland with rubber ring for PVC insulated
armoured cable complete with out going
tails, insulating tape etc for following size of
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of
following size evenly crimped with high
pressure tool & connected to switchgear
terminals with brass/cadmium plated nut
bolts in an approved manner.
Solder less crimping type Copper lugs
conforming to IS suitable for cable of
following size evenly crimped with high
pressure tool & connected to switchgear
terminals with brass/cadmium plated nut
bolts in an approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made from
sheet steel. The cable tray should be single
or double bended as per required and as
per IS 2062/1079 and shall be coated with
hot dip galvanizing as per IS 2629/4759.
with max 17.5% perforation with coupler
plate / Fish plate and GI hardware like nut -
bolt and washers etc. erection with
necessary support( included) as per
Specification and as per instruction of
engineer in charge..
SUB - TOTAL OF Cables,Cable
Terminations & Cable Trenches
5 Light Fixtures & Fans
Supply , Installation, testing and
commissioning of pre-wired, LED fitting/post
top luminaries etc of all types, complete
with all accessories and tube etc. directly on
ceiling/ wall, including connection with
sq. mm FRLS PVC insulated, flexible,
copper conductor, single core cable with
flexible conduits and coupler and earthing
etc. as required. Note:- The LED Light
fixtures should comply all international
standards third party ( LM 79 for complete
fixture, LM 80 for individual LED ). The
Manufacturer / Channel Partner of the
Manufacturer has to submit 4- Years
unconditional free Replacement Guarantee
for complete fixture.
Supplying and erecting LED indoor fittings
with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing
used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V,
5.1 Power Factor more than 0.95, THD <
15%,CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt , LED driver
efficiency > 85 %( fitting required LM-79 &
LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer
incharge may select any wattage capacity
between the ranges shown.)
( A ) Tube Light with integral / non integral
(iii) 18-20 Watts, Surge - 2KV,IP-20,
5.1.1a 2 conventional 4 feet 293.00 No
(v) 36-40 Watts, Surge-2 KV, IP-20,
5.1.1b 100 conventional 4 feet 530.00 No
(B) LED Panel Light with provision for Plane
5.1.2 front frame with translucent cover fixed to
housing complete.IP20
5.1.2a 4 (i)up to 8 Watts,4" x 4", Surge-2 KV 271.00 No
5.1.2b 160 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462.00 No
5.1.2c 30 (iv) 18 to 20 watts, 8" x 8", Surge- 2 KV 607.00 No
5.1.2d 130 (vi) 36 watts, 24" x 24", Surge- 2KV 1777.00 No
5.1.3 (G) Spot Light 425 Lumens, Surge-2KV
5.1.3a 10 (a) 3 to 7 Watts 805.00 No
(H) Mirror Light 9 Watts, wall mounted
5.1.4 4 minimum 1 feet long 309.00 No
(I) Adjustable spot light with COB led having
5.1.5 aluminium reflector of following wattage
5.1.5a 20 (ii) 12 Watts 957.00 No
5.1.5b 20 (iii) 15 Watts 1087.00 No
Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt
A.C. 50 Hz 1200 mm sweep complete
having 3blades with aluminium blades with
, canopy & 30 cm. down rod erected with
earthing.(Make shall be approved by
Engineer in charge))
Providing & erecting Approved make
Ceiling Fan with double ball bearing ISI
mark with condenser A.C.230V 50c/s.
5.3 4 mm. sweep complete, canopy erected on 1721.00 No
existing hook or clamp with earthing [ Make
shall be approved by Engineer in Charge]
Providing & erecting Approved make
Ceiling Fan with double ball bearing with
Condenser 230 volt A.C.50 Hz. 900 mm
sweep complete having 3 Aluminium
blades, canopy erected complete. [ Make
shall be approved by Engineer in Charge]
Supplying and erecting approved make
oscillating type medium duty bracket fan
with Aluminium Blades A.C. 23OV. 50cy/s
wall mounted with height adjustment and
5.5 1 rotary tilting device complete with guard, 2329.00 No
mounting accessories kit, pull cord for
speed and oscillation flexible Core plug top
complete erected with lead wires as
directed. 400MM.
Supplying & erecting approved make low
noise decorative exhaust fan having size
5.6 6 200mm with 1350 RPM with square frame 1687.00 No
ABS body with inbuilt lowers & square
Supplying & erecting fan hook box of
mm M.S. round bar bounded to the RCC
bars up to 50mm length each side and
5.7 35 pierced through a 16 Gauge M.S. box / 107.00 No
Heavy Duty PVC box complete erected
concealed in Ceiling with necessary
Providing 2.5mm.thick laminated acrylic
5.8 35 sheet to cover the fan hook or Fan box. 18.00 No
Supplying and erecting 19 / 20 mm. nominal
bore Medium Class M.S. Pipe down rod
5.9 35 erected duly painted for fan complete with 107.00 Mtr
proper insulation without leakage and
Supplying & erecting single phase approved
make industrial exhaust fan suitable for
medium duty ring mounted low noise
operation suitable for medium duty having
following dia size and maximum speed in
5 [D] 450 mm dia 900 RPM 3306.00 No
Providing suitable M.S. louver shutter of the
5.11 5 Exhaust fan. 365.00 No
Supplying & erecting electro galvanised G.I.
wire micro mesh jali cover of grade
5.12 4 required size with suitable wooden frame 628.00 Sqmtr
duly fitted in wall outside of exhaust fan for
insect protection.
Providing and erecting PVC body surface or
pendent mounting LED Bulk type 9 watt
Lighting Fitting with electronic driver. And
lumen output from luminaire 720lm , input
voltage range 90-300VAC , 50Hz cool
white(3000 to 6500k), inbuilt driver, -
20degC to +60degC working temperature,
AL frame with Beam Angle 120deg
SUB - TOTAL OF Light Fixtures & Fans
6 External lighting
Supply , Installation, testing and
commissioning of pre-wired, LED fitting
/post top luminaries etc of all typesof
external lights, complete with all
accessories and tube etc. directly on pole /
pole bracket , including connection with
/ 2.5 sq. mm FRLS PVC insulated,3 core
flexible, copper conductor, with flexible
conduits and coupler and earthing etc. as
Supplying and erecting LED street light /
Flood light fittings with High power White
LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with
toughened glass with company mark/name
engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required
LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer
incharge may select any wattage capacity
between the ranges shown.)
(A) Street Light (IP-65), Surge protection -
4KV /5000K integral and 10 kv non integral
6.1.1 ,Light must have 440VAC line supply
protection. It should withstand 48 hours for
440VAC line supply.
(f) Above 60 watts to 90 watts ( Required
(B) Flood Light (IP-65), Surge -4KV/5000K
,Light must have 440VAC line supply
protection. It should withstand 48 hours for
440VAC line supply
6.1.2.a 6 (c) Above 60 watts to 100 watts 6028.00 No
6.1.2.b 4 (v) above 120 to 160 watts 8370.00 No
Supply of approved make frp/grp pole
having followiing specifications :
FRP/GRP pole made by centrifugal
moulding process using thermoset resin
polyester/epoxy resin system having
minimum glass content 45.0%.The pole
should be in one pieceand tapered round in
shape,having smooth outside surface finish
and should be totally fre from corrosion as
well as non conductive and shock proof.
Pole should be provided with FRP/GRP
base bracket dully fabricated from
6.2 metal(M.S) and dully claded with FRP/GRP
material to avoid any metal exposer and
painted with PU paint.
Pole should mechanical properties i.e
Specfic gravity (ASTM D 792) 1.3‐1.8
Kg/m3, 2. Glass Content % by weight
absorption (ASTM D 570) <0.5%, 4. Tensile
Strength(ASTM D 638) 200+/‐50Mpa,
Flexural strength (ASTM D 790) 250+/‐
50Mpa, 6. Compressive Strength (ASTM D
695) 200+/‐50MPa, 7. Yeild Strength(ASTM
Pole should be flame retardant as per IS
6746.Resin used shall be UV resistance
and pigmented. Pole should be painted with
first coat of epoxy primer and then two coat
of highly weather resistance polyurethen
paint to ensure proper addhesion of the
paint.Minimum thickness shall be 80 to
micron.Defelection of the pole shall not
exceed more than 10.0 % of the length of
the pole for the given load.Pole should be
generally made as per the dimensional
data,performance criteria and some
interchagebility features of poles as per the
standard ANSI C123.20 latest version of
ASTM D 923/01 including cable termination
box with necessory accessories.The size of
pole and type of installation with foundation
, Anchor Base & Internal junction box as per
the manufacturer details and site
requirement . The cost of 6 Mtr & 10 Mtr
pole's Flood light mounting ring is included.
(3) 'B' class (Heavy Duty) frp/grp pole
suitable for base plate mounting
[D] Overall Length of 6.0 meter, Average
thickness : 7mm, Top/Bottom Outside Dia.
76/176mm +/‐2.Weight of Pole 25.0 Kg
14 approx. (Without base) Metal Anchor Base 16815.00 E.a.
dully frp claded (Size : 340 Ø * 12mmthk
Mounting hole PCD 285mm * 6 nos. of 20 Ø
Providing FRP/GRP arm bracket of having
6.3 15˚ arm with 50 mm OD pipe *5 mm
thk,1000mm long from pole centre
6.3.1 14 (a) Single arm bracket 1882.00 No
6.3.2 1 (b) Double arm bracket 2390.00 No
Supplying & erecting sintex make SMC
press moulded composite FRP. loop-in,
loop-out approx. 2mm thick box complete
with bakelite connector strip 4way & hinged
doors having locking arrangements with
mounting clamp with nuts, bolts & washers
suitable for erection on wall ( c)150mm x
125mm x 100mm [deep].
Providing cement concrete.for foundation
or for concrete filling in 1:2:4 ratio with 20 to
6.5 9 25 mm stone metal duly plastered with 5077.00 CU Mtr
necessary curing for pole muffing or any
B' class galvanised iron pipe 32 mm outside
dia 45 cms long duly welded on 20 cms x
20 cms x 3 mm thick M.S. base plate,
erected on wall or corner for mounting
street light luminaire with necessary
hardware materials duly painted.
SUB - TOTAL OF External Lighting
Supplying & erecting approved make
Automatic liquid level controller 6A. with
sensor testing as per instruction of Engineer
7.1 1 in charge on site complete with wiring 2332.00 Job
connection with existing wires , with copper
conductor from pump to upper and lower
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv grade
7.2 ISI marked copper wires of following size to
be erected as directed.
90 e) 1.50 Sq.mm 3 core round PVC sheathed 46.00 Mtr
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
7.3 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in
approved manner as directed .
Providing & erecting water cooler having
storage capacity 150 Ltr. & cooling capacity
150 Ltr.per hour @ an ambient temp of 45˚
C. The outlet temp. of the water should drop
by 15˚C within a hour, The water cooler
should be comprising of hermetically sealed
7.4 2 compressor, fan motor, condensing unit, 55340.00 No
water tank surrounded by evaporating, coil,
thermostats, relay etc.complete with
necessary inlet & outlet connection. The
body of water cooler will be made from
Stainless Steel.
Supplying and erecting water filter cum
purifier with ultra violate technology.
7.5 2 (Aquaguard / waterdoc model or equivalent 5371.00 No
symphony/ crystal/videocon model)
Providing & erecting open well horizontal
mono block pump set with cast iron body,
complete for three phase submersible
[D] For 5 HP 3 phase open well horizontal
mono block pump set suitable for 1350 LPM
7.6.1 2 to 310 LPM @ 10 to 42 Mtr head suitable 18561.00 No
for 50/65 mm dia delivery pipe
[C] For 3 HP 3 phase open well horizontal
mono block pump set suitable for 85 LPM to
7.6.2 1 270 LPM @ 11 mtr to 33 mtr head suitable 15552.00 No
for 50/65 mm dia delivery pipe
Supplying & erecting approved make
motor control cubical panel (Direct - on -
line) made from 16 G. CRCA sheet duly
epoxy powder painted inside and outside
with hinged doors and locking, arrangement
consisting of suitable size of ON- OFF
isolator (AC - 3/23duty) main fuses, single
phasing preventer, indicating lamps for R- Y
7.7 - B phases, overload relay, Automatic water
level controller, Ammeter, Voltmeter each
with two way selector switch incoming,
wires duly socket crimped, main contactor &
overload relay, start - stop push buttons, to
be erected on angle iron frame grouted on
wall as directed. The isolator, overload relay
& contactors will be of L & T, Siemens or
2 (a) DOL up to 5.0 H.P. 7646.00 No
Supplying & erecting approved make
phase motor control cubical panel ( Star -
Delta) made from16 G. CRCA sheet duly
painted with epoxy powder painted inside
and outside with hinged doors and locking
arrangement, consisting of suitable size of
ON- OFF isolator (AC - 3/23 duty) main
fuses, single phasing preventer cum water
level. Guard (Complete unit), Toggle switch
to by pass Single phase preventer cum
WLG, indicating lamps for R- Y- B phases,
7.8 over load relay, Automatic water level
controller, Ammeter & Voltmeter each with
two way selector switch incoming wires duly
socket Crimped, Panel to be erected on
angle iron frame grouted on wall as
directed. Star Delta & main contactor,
overload relay, thermal / Electronic Star
delta cutoff timer, start - stop push buttons.
The isolator overload relay & contactors of
L& T, Siemens or Cuttler Hamer make only.
Panel to be erected on angle iron frame
ground on wall.
(A) S/D up to 7.5 H.P. for sewerage pump
1 in basement 12865.00 No
Charges for doing liasioning work for
obtaining the necessary clearances from
the Electrical inspector / competent
Authorities for the total Electrical
installation,co-ordinating with various
agencies. All necessary drawings,
calculations, test certificates, etc. as
7.9 1 required by these authorities shall be 41000.00 No
prepared and furnished by the EPC Vendor.
Any modification/rectification as required by
these authorities shall be carried out by
theEPC Vendor at free of cost. The fees
required to be paid to these authorities for
inspection shall be borne by Owner on
production of documentary evidences.
online Un-interruptible Power Supply
Supplying and erecting approved make
online Un-interruptible Power Supply
system comprising flat cum-boost charger
with IGBT base rectifier & Inverter & sealed
maintenance free SMF batteries. The
charger having operating capacity for input
160-270V AC & inverter having output
230V,50 Hz Ac with 0.8 load power factor
with battery, over/under voltage output with
over load & short circuit protection
equipment. The system housed in CRC
sheet duly powder coated paint with
following power backup.with MS painted
batteries stand, 10% Overload capacity for
momentary load.
1 (D) 5 KVA with 1Hr Backup 128815.00 No
SUB - TOTAL OF MISC. Work
8 PASSENGERS ELEVATOR
Supply ,installing , commissioning and
testing of M.R.L. Passengers Elevator
to 10 passengers as per R & B S.O.R (
Category - Premium ) having following
specifications:- Ground+ 2 upper floor
Supplying, Erecting, Testing &
Commissioning the passenger lift having
following main features:
[1] GEAR LESS LIFT DRIVE comprising of
High Starting torque Lift 3 phase 440 V
A. C. Permanent Magnet Synchronous
motor of proper rating with high efficiency
[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback
closed loop system shall be used for lift car
and door operation which shall be full
collective selective operation hall call
demand response, UP/DOWN hall stops,
Main, Up/ Down Contactor with overload
and phase reversal relay and safety
[3] Car with M S platform with bracings of
adequate size and to sustain the impact
load cabin + passenger with safety factor of
fire for steel and side panels of Stainless
steel of sheet of grade 304 duty. Car ceiling
will be S.S. finishes with aesthetic
appearance with LED ceiling lights. Car
flooring shall be of anti skid PVC with
choice of colour of engineer in charge. Car
doors shall be of stainless steel grade
hairline finish with centre opening /
telescopic automatic doors. Car panel will
also be S.S. 304 finished with emergency
stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel
buttons and all floor switches must be with
brail language as per lift act.
[4] All landing doors must be fire rated for
hour shall be fully automatic centre
opening/ telescopic opening made of
hairline finish steel grade of 304 with key
holes and infrared curtains with Unlocking
facility from outside
[5] Appropriate battery operated emergency
light in the car along with alarm switch shall
be provided. Also, Emergency Light & Fan
should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-
down arrow along with floor position
indicator shall be provided inside the car
and at all floors.
[7] Full height infra red curtain with multiple
cross / crossing light beams shall be
[8] Automatic Rescue Device (ARD) shall
be provided accordingly of passenger
capacity with Manual Rescue Operation (
Manual Cranking Facility).
[9] Audio visual indication in the lift car
showing over loading shall be provided
such that doors kept open till excess load is
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger capacity with
automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music
shall be provided in lift car.
[13] Self diagnostics system for operational
and safety parameters shall be provided in
[14] Mechanical over speed governor with
governor calibration as per actual site
parameters and submission of calibration
certificate submission, door key holes in the
floor doors, fireman switch shall be
[15] Lift machine hoisting arrangement in
the lift machine room and monkey ladder for
lift pit should be provided by the lift agency,
along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be
provided without any extra cost, where ever
required as / if directed by engineer in
[17] Permanent wiring with necessary
safety devices like RCCB in all circuit, Over
Voltage Under Voltage protection and THD
eliminator in circuit for lift machine room
and lift well with proper numbers of light
points, with fixtures, exhaust fan and plug
points shall be provided by the agency.
Only 3 phase Power Supply shall be made
available by department in lift machine
room. Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional
and alteration in lift shaft and machine room
related to erection of lift shall be made by lift
agency without any extra cost.
(granite/marble fixing around all landing
door openings are not in lift agency’s
[19] Agency has to provide all working
drawings and documents and liaison
services for obtaining all necessary
permission from lift inspector and other
[20] acrylic transparent licence/display A4
size holder in lift car
[20A] As per statutory requirement of Govt.
Of Gujarat lift & escalator act 2000, lift
agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground
4.carrying out third party lift inspection
during/after lift erection and provide report
by third party authorized by concern
licensing authority 5.agency has to
provide third party insurance upto
completion of free maintenance period and
submit the document for the same.
[21] Car Panel Operating Buttons with floor
position indicator/buttons must be of Auto
Glow type clearly visible when view from
[22] For Physically Handicapped person
Full Length Handrails of hairline finish steel
grade of 304 should be provided at
appropriate height on the Rear & Side Wall
Panels in Lift Car.
[23] With Necessary KVA rating voltage
controlled Stabilizer suitable for your
controller, drive and all equipments of lift.
[24] Necessary rating of DP Elcb and FP
Elcb required for lift is in scope of work
which rating is sugested by CEICED
Department (electrical Inspector)
(B) SPECIAL FEATURES DESCRIPTION
OF LIFTS for PREMIUM category
1. Advanced control system dual 64 bit
embedded microprocessor with CANBUS
Serial Communication mode including
Regenerative power efficient operation,on
site programming facility, Anti nuisance,
Pte-opening, BMS/RMS with necessary
online real time monitoring system having
necessary connectivity for remote
monitoring & other suitable supporting
hardware & software devices to fulfil the
2. Floor Indication LCD Display with call
registration & brail mark with arrival gong
and hall lantern & TFT Screen in the car
with MP3 Voice Announcer.
3. CAR Panel should be Scratch resistive
SS Moonrock finish / Hair Line /
Honeycomb for car and all Doors, All
landing doors must have fire rating up to
hours and car door must have multi-level
crisscross beam door protection.
4. To & fro communication system & wiring
(i.e. car , control room & guard room ) and
Each elevator are equipped with remote
monitoring system.agency has to provide
mobile app and user id and password for
8/10 passengers Ground + 2 upper floors
with Rated Speed of 1.0 m/sec -
AMC LOGO design as per given by
department to be embossed inside the lift
car wall opp. To door.
(C) With General PLUS ADDITIONAL
2 SPECIAL FEATURES attached herewith. 1460178.00 No
SUB TOTAL of Passengers Elevator
Providing and erecting approved make
ductable split Air Conditioning unit each
consist of remote located condensing
unit and an evaporating unit complete
with interconnecting insulated refrigerant
piping up to 10 RMT. rigid PVC, drain piping
of 10 kg / cm2 dully insulated with nitrile
rubber insulation of 10 RMT with ECO
Friendly Green gas. The condensing unit
is complete with hermetically sealed
scroll compressor & condenser unit which
effectively achieves heat rejection by
utilizing air of fan and coil type
condenser. The evaporating unit will be
complete with DX evaporator centrifugal
blower, blower motor along with
microprocessor biased remote controller
with memory backup etc.
DUCTABLE SPLIT AIR CONDITIONERS
9.1.1 10 5.5 TR Ductable A.C. Unit 129950.00 No
9.1.2 8 8.5 TR Ductable A.C. Unit 190900.00 No
SPLIT AIRCONDITIONING
Providing and erecting approved make split
air-conditioning unit consisting of copper
condensing unit with fan motor, hermetically
sealed rotary compressor with accessories
etc. duly connected separately erected
evaporating unit and blower motor with its
accessories by means of extra supplied
proper insulated copper tubing,drain PVC
pipes suitable for ( cost includes powder
coated Stand, Eco Friendly green gas
charging, 15A plug top & Remote Control)
with necessary core cutting.
(2)For ISEER Range (KWH/KWH)(4.0 to
2 (c) for 2 ton capacity 58706.00 No
Supplying and erecting insulated pair of soft
copper tubing including power and control
cable,necessary PVC drain pipes for Split
AC machine up to 4 TR capacity
Supplying and installing MS angle , powder
coated / Painted standard type of wall/floor
9.4 stand mount for outdoor unit of split AC of
following capacity, erected with necessary
hardware materials as directed.
(B) 35mm*35mm*5mm thick M.S angle
2 suitable for above 2 TR to 4 TR Capacity of 1496.00 No
9.5 Refrigerant Piping & Cabling for Air cooled
Supply, Installation, testing and
commissioning including vaccumiazation
and Nitrogen testing of following nominal
sizes of soft/hard drawn copper refrigerant
piping for VRV system, complete with
fittings, with suitable adjustable ring type
hanger supports, jointing/brazing including
accessories, insulated with XPLE Class-0
tubular insulation/with Class-0 closed cell
elastometric nitrile rubber tubular sleeves
sections of specified thickness as given
below for Suction and Liquid lines, all
accessories as per specifications etc with
necessary refrigerant joint as required :
(B) 9.5 mm dia (OD) (Soft drawn) with tube
9.5.1 395 thickness 1.2 mm with 19 mm thick 367.00 RMT
(C.) 12.7 mm dia (OD) (Soft drawn) with
9.5.2 395 tube thickness 1.2 mm with 19 mm thick 506.00 RMT
(F) 22.2 mm dia (OD) (Hard drawn) with
9.5.3 410 tube thickness 1.2 mm with 19 mm thick 953.00 RMT
(H) 28.58 mm dia (OD) (Hard drawn) with
9.5.4 410 tube thickness 1.2 mm with 19 mm thick 1191.00 RMT
Rigid UPVC drain pipe of 10 Kg/cm2. rating
9.6 with 9 mm thick.nitrile rubber insulation.
Supply and Installtion for Canvass
9.7 18 connections with zip to Ductable Ac Unit 1650.00 Nos.
9.8 SHEET METAL DUCT
Supply, installation, balancing and
commissioning of fabricated at site GSS
sheet metal rectangular/round ducting
complete with neoprene rubber gaskets,
elbows, splitter dampers, vanes, hangers,
supports etc. as per approved drawings and
specifications of following sheet thickness
complete as required.
Supplying & fixing of powder coated
extruded aluminium Supply Air Grills with
aluminium volume control dampers
complete as per specifications and size &
shape as per site requirement and
approved design.
Supplying & fixing of powder coated
extruded aluminium Return Air Grills with
louvers but without volume control dampers
complete as per specifications and size &
shape as per site requirement and
approved design.
Supplying, fixing testing commissioning of
supply air diffuser of powder coated
aluminium with aluminium volume control
dampers with anti smudge ring & removable
core and size & shape as per site
requirement and approved design.
Supplying, fixing testing commissioning of
Return air diffuser of powder coated
aluminium without volume control
dampers with anti smudge ring & removable
core and size & shape as per site
requirement and approved design..
9.13 INSULATION WORK
Supplying and fixing of following
thickness duly laminated aluminum foil
of mat finish closed cell Nitrile rubber (Class
"O") insulation on existing duct after
applying suitable adhesive for Nitrile
rubber. The joints shall be sealed with
mm wide and 3 mm thick self adhesive
nitrile rubber tape insulation complete as
per specifications and as required.
725 13 MM Thick 583.00 Sqmtr
Supply and Fixing of Acoustic Insulation of
Duct by Open Cell Nitrile Rubber, having
density 140 - 180 kg/m³.NRC value is
The Insulation shall pass Air Erosion
Resistance Test in accordance to ASTM
Standard C 1071 - 05 from an independent
accredited testing agency. EPA Approved
for use in Ductwork. 9mm / 10mm size
Supplying & fixing 50mm thick TF quality
expanded polystyrene for underdeck
9.15 605 insulation on slab/wall /shaft exposed to 409.00 Sqmtr
sun/atmosphere as per specifications.
Fresh air intake louvers in 20 G extruded
aluminium construction with 18 G extruded
aluminium blades, bird screen, rain cowl,
G‐4 type Pre filters of 80‐90% down to
micron & necessary supporting
arrangement. Louver will be provided with
SS wire mesh of 6.35 X 6.35 mm (i.e.
mm wire dia). All shall be housed in G.I.
casing to enable fitted in PEB structure wall
with filter removal facility from inside.
Supply, installation, testing and
commissioning of ceiling mounted Single
Inline fan - 500 cfm , 15 mm static pressure
suitable for 220±10% volts, 50 Hz,single
phase AC supply and complete with all
standard accessories such as
motors,blades etc.The casing of inline fan
9.17 4 shall be accoustically lined and shall be 20120.00 No
selected for lower noise level. Fan motor
shall have inbuilt speed controller. Provision
of connection with 1.5 sq. mm PVC
insulated FR copper conductor wire from
the point outlet to the fan as required shall
be deemed to be point outlet to the fan to
be included in this cost.
Misc. Civil Work like Wall jari , Civil cutouts
with Core Cutting ,walls / slab opening to
Pass Ducts , Copper Pipes & Drain pipes
including with Refinishing & Plastering of
the same to the original finish.
Supply, installation, testing &
commissioning of 6 FEET Length AIR
Curtain for Hall doors that are exposed to
ambient, with all necessary accessories and
mounting fixtures, Air curtain have Stainless
Steel body ( 304 grade), Max. Air velocity at
nozzle : 21 m/s, 2700/2100 RPM,
CFM,Noise level 50-55db,No. of Blowers :
6, 220V/1P/50hz ,820w motor suitable for
continues/intermittent functioning.
Providing and fixing Trap Door of requried
size with using wooden frame of Size :-
X 50 and Hinging with Support of 12mm
thick Round Bar with Anchor Fastner on
Ceiling and Nut Bolt with Wooden Frame at
Level of False Ceiling Bottom and using
9.20. 40 19mm thick M.R.Quality ISI make plywood 7054.24 Sqmtr
for opening Door in two part and fixing with
require Hinches, Lock, Screw and all other
require Hardware and open Serface finish
with 1.00 mm thick Laminate In and Out
side as per Arcitects Requirement with all
Material & Labour etc. Complited.
Providing , erecting , fabricating the M.S.
structure as per requirement on site
incorporating proper size of M.S.
angles,square,round, flats, bars, channels,
sections complete with cutting, welding,
grinding & finishing duly painted with one
coat of red oxide with erection on site as
per direction of engineer in charge with
necessary grouting, cementing, plastering &
finishing complete.
Supply and laying 1.5sqmm x 7core cu
9.22 810 flexible round cable from indoor to outdoor 180.00 Mtr
SUB TOTAL of HVAC WORK
10 ANNUAL OPERATION WORKS
Annual Operation Contract of
Electrical/ELV/passenger elevators and
HVAC System For DLP + 1 Year.
Annual Operating charges for 1-Year of
DLP + 1 year for entire Electrical / ELV and
HVAC system installed at site including
General working hrs plus Additional
working hrs during occupation of hall with
one skilled electrictian , who also look after
operation of passenger elevator. AOC
period starts after Virtual completion of
project. Payment for AOC shall be made
on quarterly basis & after completion of
each quarter. Note:- Such person should
inform to Lift Maintenance agency during
breakdown or any Minor fault.
Operating Charges only During Guarentee /
Defect Liability period.
Annual operation Charges for First year
10.2 12 After Guarentee / Defect Liability Period 14682.20 Month
SUB-TOTAL Of ANNUAL Operation
contract Of Electrical /passenger
elevators and HVAC System
11 COMPREHENSIVE Maintenance
Annual Comprehensive Type
Maintenance Contract of ELECTRICAL +
HVAC + passenger elevators For 1-
Year DLP + ONE Year
Annual comprehensive Type Maintenance
11.1 1 Charges only During Guarentee / Defect FREE Year
Liability period.
Annual comprehensive Type Maintenance
11.2 1 Charges for 1st Year after Guarentee / 399003.94 Year
Defect Liability period.
SUB-TOTAL Of ANNUAL comprehensive
maintenance contract Of Electrical /
HVAC and passenger elevators
I. No. Qty Items Unit Rate Per Amount
Final specification and block diagram
shall be submitted by CCTV camera
SITC of 1/2.8" CMOS 3MP IP Fixed Lens
IR rugged DOME Camera having
progressive scanning system , Pixels 3MP
(2304 x 1296),Lens 2.8 mm, Fixed, F1.4,
Minimum Illumination color / BW: Color:
0.002 Lux @ F1.6, BW 0 Lux IR ON,IR
Distance 40 Mtrs,Wide Dynamic Range
Db,Privacy Masking Off/On (5 Areas),Local
Storage Micro SD/SDHC/SDXC card slot
(2TB),Gain Control 0 ~ 100%,Angle of View
(H x V) H:87.2° V:49.1°,Ethernet 10 Base-
T/100 Base-TX Ethernet (RJ-
45),Protocols:IPv4, IPv6, TCP/IP, HTTP,
HTTPS, RTSP/RTP/RTCP, IGMP/Multicast,
SMTP, SNMP, DHCP, NTP, DNS, DDNS,
CoS, QoS,802.1X, UPnP, mDNS(Bonjour),
UDP, ICMP, ARP, TLS, SFTP,Body
Material Aluminium +
Polycarbonate,Number of Video Streams
4,Ingress Protection IP66, IP67, Event Notifi
cation HTTPS, HTTP, SMTP, ONVIF, Bit
Rate 100 K ~ 6 Mbps Certificates: FCC
PART 15, CE (EN 55032), ICES-003,CE
(EN 55035),UL listed to UL/CSA 62368-1,
BIS IS 13252 (Part 1)/IEC 69050-1,RoHS,
REACH, WEEE,BIS ER, STQC
SITC of 1/2.8" CMOS 3MP IP Fixed Lens
IR rugged Bullet Camera having
progressive scanning system , Pixels 3MP
(2304 x 1296),Lens 3.6 mm, Fixed, F1.4,
Minimum Illumination color / BW: Color:
0.002 Lux @ F1.6, BW 0 Lux IR ON,IR
Distance 50 Mtrs,Wide Dynamic Range
Db,Privacy Masking Off/On (5 Areas),Local
Storage Micro SD/SDHC/SDXC card slot
(2TB),Gain Control 0 ~ 100%,Angle of View
(H x V) H:87.2° V:49.1°,Ethernet 10 Base-
T/100 Base-TX Ethernet (RJ-
45),Protocols:IPv4, IPv6, TCP/IP, HTTP,
HTTPS, RTSP/RTP/RTCP, IGMP/Multicast,
SMTP, SNMP, DHCP, NTP, DNS, DDNS,
CoS, QoS,802.1X, UPnP, mDNS(Bonjour),
UDP, ICMP, ARP, TLS, SFTP,Body
Material Aluminium +
Polycarbonate,Number of Video Streams
4,Ingress Protection IP66, IP67, Event Notifi
cation HTTPS, HTTP, SMTP, ONVIF, Bit
Rate 100 K ~ 6 Mbps, Certificates: FCC
PART 15, CE (EN 55032), ICES-003,CE
(EN 55035),UL listed to UL/CSA 62368-1,
BIS IS 13252 (Part 1)/IEC 69050-1,RoHS,
REACH, WEEE,BIS ER, STQC
Supply , Installation , Testing and
commissioning of 32 Channel NVR
(Network Video Recorder) Embedded Linux
based for recording upto 32CH at 1080P,
960fps with 04 nos. SATA HDDs minimum
40TB storage or more (recording
requirement all cameras recording at 2MP,
25fps for 30 days), H.265
HEVC/H.264/MJPEG codec decoding,
Front Panel with LEDs Indication for Power
& HDDs Status, 3 nos. USB, ONVIF S,
Time Sync with NTP, Encrypted Streaming
& Control, 2-Way Audio Line & Out, PTZ
Operation Pan, Tilt, Zoom, Support, Pre &
Post Alarm Recording Support,
Recording/Evidence Clip Export to USB,
Channel Synchronous Playback, Playback
1.3 1 control i.e Play, Pause, Stop, Fast Forward, 66202.00 No
Backward, Speed Control, Timeline &
Zoom; Snapshot, Web Client, Central
Monitoring Software, iPhone; iPad; Android
based Mobile clients, 02HDMI & 01VGA
Output, 04 On Board HDDS each up to
10TB, Alarm Input (16 nos.), Alarm Output
(04 nos.), RS232/485, eSATA, 256 Mbps
throughput, NDAA Section 889 Compliant,
Operating Temperature –10°C to 55°C,
Certification : Certifications: ONVIF
compliant, UL/CSA 62368-1, CE (EN
50130-4), FCC Part 15, EN 55032, NDAA &
RoHS (EN63000) compliant. Including fixing
accessories and cable termination with
required connectors/Jack, complete in all
respect as per instruction of engineer in-
Supply Installation Testing &
1.4 2 Commissioning of 8TB Surveillance 25150.00 No
Supply, Installation, Testing and
Commissioning of 43 inch, Professional
LED Display Cum Commercial TV with
Android 11 & Inbuilt play store, UHD
resolution, 400 nits brightness, It's 24*7
usage, 50,000 hours life, 3 years warranty,
Android 11 with inbuilt play store, Inbuilt
wifi, Landscape / Portrait mode, Inbuilt
Bluetooth, 2 GB / 16 GB Memory, Inbuilt
SOC with HDMI cable
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
1.6 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in
approved manner as directed
CAT 6 UTP Cable
Supplying & erecting approved make LAN
1.7 cable of following size in existing pipe as
Supply, Installation, Testing &
1.8.1 1 Commissioning of 9U wall mount rack. 12053.57 No
1.8.2 2 3U wall mount Rack 5025.01 No
Supply, Installation, Testing &
1.8.2 1 Commissioning of weather proof outdoor 12840.00 No
rack. For 8 port POE switch.
SITC of 24 x 10/100/1000BASE-T PoE
ports 4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security
features L2+ Static Routing Optional
“standard mode” or “surveillance mode”
management user interface 193 W PoE
budget (Including Five year free
maintenance with guarantee)
SITC of 8 x 10/100/1000BASE-T PoE ports
2 x Gigabit SFP ports Advanced L2
switching and security features L2+ Static
1.10. 2 Routing Optional “standard mode” or 18218.00 No
surveillance mode” management user
interface 65W PoE budget [Approved by
Competent Authority
Supply, Installation Testing &
Commissioning 5 Mtr. HDMI Interface
1.11 1 Cable as per the detailed Specifications 820.00 No
supports transmission of 4K Signals as per
the detailed Specifications
Supply, installation, fixing, testing and
commissioning of PVC Junction box for
1.12 29 CCTV Camera, IP65, outdoor application. 440.00 No
Junction Box size will be as per vendor's
requirement and site condition.
1.13 1 SITC of Patch Panel Cat 6 UTP Keystone 4357.00 No
Type- 24 Port-Fully Loaded (Including Five
year free maintenance with guarantee)
SITC of Jack Cat 6 Keystone UTP
1.14 29 (Including Five year free maintenance with 160.00 No
SITC of CAT6 UTP 24AWG PATCH
1.15 29 CORD:1M,Plug 30U' Snag less (Including 155.00 No
Five year free maintenance with guarantee)
SUB -TOTAL OF CCTV SYSTEM
2 COMPREHENSIVE Maintenance
Annual Comprehensive Type
Maintenance Contract of CCTV System
For 1-Year DLP + ONE Year
Annual comprehensive Type Maintenance
2.1 1 Charges only During Guarentee / Defect FREE Year
Liability period.
Annual comprehensive Type Maintenance
2.2 1 Charges for 1st Year after Guarentee / 19223.42 Year
Defect Liability period.
SUB -TOTAL OF CCTV Comprehensive
Maintenance work
I. No. Qty Items Unit Rate Per Amount
FIRE FIGHTING SYSTEM
Design,Drawing,Supply,installing,testing
and commissioning of FIRE HYDRANT
Internal / External Hydrant
Supplying, Installation, Testing and
Commissioning of electric driven main
Hydrant fire pump and Sprinkler pump
suitable for automatic operation and
consisting of following: complete in all
respect as required.
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body &
bronze impeller with stainless steel shaft,
mechanical seal to ensure a minimum
pressure of 3.5 kg/sq. cm. at highest and
farthest outlet at specified flow of 2280 lpm
at 65 Mtr. head conforming to IS 1520.with
suitable size of footvalve confirming to IS
4038, Pressure rating PN2 , preventing
entry of foreign body to pump through
suction pipe, perfectly flat seating surfaces
for good sealing.
b) Suitable HP Squirrel cage induction
motor, TEFC, suitable for opertion on
volts, 3 phase 50 Hz. AC with IP 55 class
protection for enclosure, horizontal foot
mounted type with Class - 'F' insulation,
conforming to IS-325.
c) M.S. fabricated Common base plate,
coupling, coupling guard, foundation bolts
etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
The pump shall be capable of giving not
less than 150% discharge at ahead not less
than 65% of the rated head.
Supplying, Installation, Testing and
Commissioning of electric driven
1.1.2 1 pressurisation pump suitable for automatic 61717.00 Set
operation and consisting of following:
complete in all respect as required
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body and
bronze impeller with stainless steel shaft,
mechanical seal at specified flow of 180 lpm
at 70 m. head conforming to IS: 1520.with
suitable size of footvalve confirming to IS
4038, Pressure rating PN2 , preventing
entry of foreign body to pump through
suction pipe, perfectly flat seating surfaces
for good sealing.
b) Suitable HP Squirrel cage induction
motor TEFC type suitable for operation on
415 volts, 3 phase 50 Hz. AC with IP
Class of protection for enclosure, horizontal
foot mounted type with Class F' insulation,
conforming to IS :
c) M.S. fabricated Common base plate,
flexible rubber coupling, coupling guard,
foundtion bolts etc. as required.
d) Suitable cement concrete foundation duly
plastered with anti vibration pads.
1.1.3 ENGINE DRIVEN PUMP
Supplying, Installation, Testing and
Commissioning of diesel engine driven
1 main fire pump suitable for automatic 506181.00 Set
operation and consisting of following:
complete in all respect as required
a) Horizontal type, single stage, centrifugal,
end suction pump of cast iron body and
bronze impeller with stainless steel shaft,
mechanical seal to ensure a minimum
pressure of 3.5 kg/sq. cm at highest and
farthest outlet at specified flow of 2280 lpm
at 65 m. head conforming to IS
b) Suitable HP, 1500 /1800 RPM water
cooled with radiator, diesel engine
conforming to relevant BS & IS standard
complete with auto starting mechanism,
12/24 volts electric starting equipment,
AH lead acid battery with battery stand,
exhaust pipe extended upto 6 m. outside
pump house duly insulated with 50 mm
thick glass wool with 1.0 mm. thick
aluminium sheet cladding, residential
silencer, instruments and protection as per
specification, stop solenoid for auto stop in
the event of fault with audio indications,
painted with post office red colour etc. as
c) One 200 Ltr capacity day oil storage tank
fabricated from 3 mm thick M.S. plates.
Tank shall be provided with inlet, outlet,
overflow, air vent, drain connections, filling
connection & level indicator. Tank shall be
mounted on a suitable steel structure
(Painted with 2 coats of red oxide paint).
Tank shall be provided with two or more
coats of synthetic enamel paint outside over
two coats of red oxide primer.
d) M.S. Fabricated Common base plate,
coupling, coupling guard, foundation bolts
etc. as required.
e) Suitable cement concrete foundation duly
plastered with anti vibration pads.
Fabrication, Supplying, Installation, Testing
& Commissioning of electrical control panel
of cubical construction, floor mounted type,
fabricated out of 2mm thick CRCA sheet,
compartmentalised with hinged lockable
doors, dust and vermin proof, powder
coated of approved shade after 7 tank
treatement process, cable alley, inter-
connection, having switchgears and
accessories mounting and internal wiring,
1 earth terminals, numbering etc. complete in 311460.00 No
all respect, suitable for main fire pump,
pressurisation pump complete as per
CPWD specification with following in
coming and Outgoings, suitable for
operation on 415V, 3 phase, 50Hz Ac
Supply with enclosure protection class IP
42 as required :suitable for operation on
415 V, 3 phase, 50 HZ, AC supply with
enclosure protection class IP 42 as
A. Incoming Feeder:-
(i) 1 No of 250 A,35KA, 415V,FP MCCB
with Thermalmagnetic Based Releases
having O/C, S/C ,E/F protection, Digital
ELR 96x96mm with CBCT, FP Spreader
Terminals 1 set= 8 Pcs, Extended Rotory
Handle for MCCB, 240V AC Shunt Trip coil
(ii) LED type indicating Lamp with suitable
rating 2 Amp SP MCB:- 1 Set (each set
comprise of R,Y,B)
(iii) Digital type 3 phase Multi function Meter
with suitable rating of MCB & 3 Nos. of
single core epoxy resin cast type CTs of
250/5 Amps, 10 VA, CL 1.0 ratings -1 Set.
415 V, 200 Amps, FP Aluminium Busbars
with Heat shrinkable color code insulation
OUTGOINGS:-( All outgoing feeders for
pumps should have digital Ammeter with
selector switches and LED type
ON,OFF,Trip indicating Lamps )
1 sets - 160 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for 85 HP pump with overload
protection, current sensing type single
phase preventor complete with all
acceessories and internal wiring required
for automatic operation,selector switch for
local/remote, auto/manual/OFF operation.
1 sets - 160 A, 25kA TPN MCCB, Ics=100%
Icu, with fully automatic Star/Delta starter
suitable for 85 HP pump with overload
protection, current sensing type single
phase preventor complete with all
acceessories and internal wiring required
for automatic operation,selector switch for
local/remote, auto/manual/OFF operation.
1 no.63A,16KA MCCB Ics=100%,Extended
Rotry handle with TM release having O/C &
S/C protection with 12.5 HP fully automatic
star/ delta starter , current sensing type,
Single Phase Preventer, ON/OFF Push
Button & LED type Indicating lamps
complete with all accessories and internal
wiring required for automatic operation,
selector switch, for local/remote,
auto/manual operation
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch & 3 attempt
starting device, timers and relays as
required, push buttons, start/stop in manual
ii) LED type Indication lamp for High/Low
Lub. Oil pressure, High Water Temp and
Engine ON indication.
iii) Battery charger suitable for 12 V/24 V
DC with boost and trickle selector switch, 0-
30 V DC volt meter, 0-20 Amp DC
iv) All standard relays, accessories for
automatic operation of diesel engine, wiring
with 1.5 sq mm PVC insulated copper wire
between various sensors and system
controller / starter, suitable size cable for
battery charging etc. as required.
System Controller
Designing, Supply, Installation, Testing and
Commissioning of system controller to
control operation of Main Electric Fire
Pump, Diesel Pump, Pressurisation Pump,
in sequence as per specification consisting
of relays, timers, sensors, annunciation
window for fault indication, control wiring
complete as specification.
3 NOS. 25A DP MCB " C " Curve
Providing and fixing in position the
1.3 3 industrial type pressure gauges with gun 967.73 Set
metal / brass valves complete as required
Providing, fixing, testing and commissioning
1.4 3 of Pressure Switch with Needle Valve. 1329.87 Set
Supplying, Installation, Testing and
commissioning of Air vessel fabricated from
10mm MS plate with dished ends,dia of
mm and height 1500 mm with suitable
supporting legs, outside painted with one
1.5 1 coat of primer and two coats of synthetic 48500.00 No
enamel paint of approved shade, complete
with one 25mm dia connection from pump
delivery, one 25 mm drain with
valve.Complete as per technical
specification & drawing details.
Providing, laying, testing & commissioning
of 'C' class heavy duty MS Pipe conforming
to IS 1239 i/c fittings like elbows, tees,
flanges, tapers, nuts bolts, gaskets etc., in
ground including excavation and providing
cement concrete blocks as support,
anticorrosive treatment with coaltar/asphalt
tape as per IS 10221, refilling the trench
etc. of following sizes complete as required
.( For HYDRANT )
30 100MM Dia 2300.63 Mtr
Providing, laying, testing & commissioning
of 'C' class heavy duty MS pipe conforming
to IS 3589/IS 1239 including Welding,
fittings like elbows, tees, flanges,tapers,
1.7 nuts bolts, gaskets etc. and fixing the pipe
on the wall/ceiling with suitable
clamp/support frame and painting with two
or more coats of synthetic enamel paint of
required shade complete as required :
1.7.9 5 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
Supplying and fixing Single headed internal
/ External hydrant valve with 1 No. 63 mm
dia instantaneous FM Gunmetal/Stainless
1.8 Steel coupling and cast iron wheel,ISI
marked, conforming to IS 5290 (type A) with
blank Gunmetal/Stainless Steel cap and
chain as required :
14 Single headed Stainless steel 5549.04 No
Providing, fixing, testing and commissioning
of Wall mounting swing type first aid Fire
Hose Reel with drum, hanging bracket,
1.9 13 M x 25 mm dia high pressure hose reel 10499.50 No
tubing as per IS:884 with shut nozzle and
ball valve and all required accessories.
Supply, Installation, Testing and
Commissioning of Weather proof Standard
Fire Hose Cabinet wall mounting type
(750 mm x 600 mm x 250 mm deep)
1.10. 13 having Double door opening with 4726.50 No
necessary locking arrangement by allan
key suitable for housing 2 no.x15 mtrs.
hose pipe, 1no. Branch pipe & nozzle
spanner.Duly synthetic enamel painted.
Providing ISI marked RRL (IS : 636, type‐A)
fire hose pipe 15 meter long and 63 mm dia
with ISI marked (IS : 903) Stainless steel
1.11 26 male and female coupling bound and 4020.55 No
rivetted to hose pipes with copper rivets and
copper wire complete as required.
Providing Stainless steel ISI marked
mm. dia. male Instantaneous pattern short
branch pipes with 20 mm dia. Nozzle as per
1.12 14 IS : 903, suitable for 10 Kg/sqcm operating 1502.28 No
pressure and suitable for interconnections
to hose pipe coupling as required.
Supplying and fixing of fire brigade
connection of cast iron body with gun metal
male instantaneous inlet couplings
complete with cap and chain as reqd. for
suitable dia MS pipe connection conforming
1.13.1 1 2 way - 100 mm dia M.S. Pipe 6094.09 No
1.13.2 1 4 way - 150 mm dia M.S. Pipe 12634.09 No
Providing, fixing, testing and commissioning
1.14 2 of 25 mm dia Air Release Valve and Ball 1949.25 No
Valve assembly for Air release system.
Providing, fixing, testing and commissioning
1.15 1 Pressure Relieaf Valve 25mm dia with Ball 4940.68 No
Supplying and fixing orifice plate made out
of 6 mm thick stainless steel (Grade 304)
with orifice of required size to be fitted
1.16 14 between flange & landing valve of external 1932.76 No
and internal hydrants to reduce pressure at
the outlet to the level of 3.5 kg/cm2
complete as required.
Supplying, fixing, testing and
commissioning of butterfly valve of PN
rating with bronze/gunmetal seat duly ISI
marked complete with nuts, bolts, washers,
gaskets conforming to IS 13095 of following
sizes as required :
Providing, installation, testing and
commissioning of non-return valve of
1.18 following sizes confirming to IS:5312
complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
Providing, installation, testing and
commissioning of stainless steel Y-strainer
1.19 fabricated out of 1.6 mm thick stainless
steel, Grade 304, sheet with 3 mm dia holes
with stainless steel flange.
Supply, Installation, Testing and
1.20. 12 Commissioning of Brass. Ball Valves with 737.27 No
all fittings required. 25mm size
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv grade
1.21 ISI marked copper wires of following size to
be erected as directed.
120 f) 1.50 Sq.mm 4 core round PVC sheathed 67.00 Mtr
SITC of fire pump start stop push buttons in
SITC of 2 Zone standalone Fire Alarm
control Panel, 16X2 Character LCD
Display, provision for zone wise contact and
1.23 1 sounder. Panel does not have provision to 9300.00 No
connect Repeater Panel. Make: Ravel
Approval: CE Mark. (Including Five year
free maintenance with guarantee)
Providing and erecting ISI mark Medium
class RIGID PVC PIPES of following size
complete to be erected on/in wall or ceiling
1.24 erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution
& Clamps with following dia of pipes, in
approved manner as directed
Supply, Installation, Testing and
Commissioning of Single action Manual Pull
Station.Shock and Vibration Resistant, pull
Down Lever Remains Down Until Reset.
1.25 6 Shall be Polarity Insensitive (with all 1201.75 No
mounting accessories , complete with
Junction Box for mooting on Surface, Cable
lugs at Ends, cable compression glands,
cable tags and ferruling.
Supply, Installation, Testing and
Commissioning of Conventional Sounder
cum strobe having tone settings with range
of 95dbA and field selectable 15/30/75/110
1.26 6 candelas.(with all mounting accessories , 1201.75 No
complete with Junction Box for mooting on
surface, cable lugs at ends, cable
compression glands, cable tags and
CABLES AND TERMINATIONS
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench
/ pipe at road crossing or floor of following
1.27.1 36 (B) 3 core 4 Sq. mm 285.00 Mtr
1.27.2 15 (G) 3 core 6 Sq. mm 392.00 Mtr
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench
/ pipe at road crossing or floor of following
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench
/ pipe at road crossing or floor of following
size of cables.
Providing and, fixing heavy duty flange type
brass cable gland with rubber ring for PVC
1.30. insulated armoured cable complete with out
going tails, insulating tape etc for following
size of cables.
1.30.2 4 (C) 2 to 4 core 10 Sq. mm 38.00 No
1.30.3 8 (D) 2 to 4 core 16 Sq. mm 47.00 No
Solder less crimping type Copper lugs
conforming to IS suitable for cable of
following size evenly crimped with high
pressure tool & connected to switchgear
terminals with brass/cadmium plated nut
bolts in an approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made from
sheet steel. The cable tray should be single
or double bended as per required and as
per IS 2062/1079 and shall be coated with
hot dip galvanizing as per IS 2629/4759.
with max 17.5% perforation with coupler
plate / Fish plate and GI hardware like nut -
bolt and washers etc. erection with
necessary support( included) as per
Specification and as per instruction of
engineer in charge..
Supply, installation,testing and
commissioning of Chemical Earthing with
UL Certified 17.2mm Dia. X 3000mm Long
254 Micron-Copper bonded M.S. Rod
manufactured as per IEC 62561-2 with
25Kg Bentonite powder plus " U " bolt rod
clamp complete with Lockable high
performence chamber suitable & tested for
5000T capacity with SS Hardware.or
Supplying, Installation, Testing and
commissioning Sewage water submersible
pumping sets of CI casing & impeller, SS
shaft, including with inbuilt water level
sensors for operating the pumps
automatically and all accessories suitable
for operation on 220 V-240 V, single phase,
50 Hz. AC supply etc. as reqd.
> 10 mm solid handling capacity,Minimum
Capacity - 50 LPM,Minimum Head >
Charges of Preparing Design , Drawings
,Testing of Fire Fighting System with
1.35 1 necessary Approval from Local Fire 76271.19 job
authority.( Including Pre-NOC and NOC
from Fire authority. )
Providing, fixing, testing and commissioning
1.36 of below Auto Glow Signages.
1.36.2 12 Fire Equipment: 4" X 12" 514.97 No
In case of Fire, do not use lift, use
1.36.3 6 staircase: 8" x 8" 650.00 No
1.36.4 3 Fire Lift 4"X12" 514.97 No
1.36.5 6 Fire Extinguishers 8"x 4" 480.00 No
1.36.6 6 Floor Sign": 4" X 12" 514.97 No
1.36.7 6 Fire Hydrant 4” X 12” 514.97 No
1.36.8 6 Fire Hose Reel.4” X 12” 514.97 No
1.36.9 6 DCP Extinguisher 8"x 4" 480.00 No
1.36.10 6 CO2 Extinguisher 8"X 4" 480.00 No
Providing, fixing, testing & commissioning of
1.37 15mm dia quartzoid bulb type sprinklers of
rating with required accessories :
Pendent Sprinkler 57°C standard response
Pendent Sprinkler 68°C standard response
1.37.2 40 (K-80) UL Listed 471.50 No
Supplying, installation, testing &
commissioning of sprinkler flexible pipe (UL
Listed) of stainless steel complete with
NPT on reducer thread with maximum
working pressure of 175 PSI test pressure
of 875 PSI (Burst) with branch line (Inlet)
25mm NPT male thread to sprinkler head
(Outlet) 15mm NPT female thread with
reducer, nipple, 2 side brackets,center
bracket, stockbar of following sizes
complete as required etc of following sizes
Providing fixing, testing and commissioning
of Drainning & Testing Assembly 25mm dia
1.39 1 with Sight Glass , Union joint , Ball Valve & 4939.25 No
Supplying, Installation, Testing and
commissioning of Flow Switch on sprinkler
distribution header on each floor with
1.40. necessary Junction Box and shall be
connected to fire alarm panel through cable.
Flow switch shall be "UL" Listed size
150mm dia/ 100mm dia/ 80mm dia.
Providing, fixing, testing and commissioning
of Sprinkler Alarm valve of cast iron body
and brass/bronze working parts comprising
of water motor alarm, bronze seat clapper,
and clapper arm, hydraulically driven
mechanical gong bell to sound continuous
alarm when the sprinkler system
activates,pressure guages, emergancy
releases, strainer, pressure switch, cock
valve complete with drain valve and bypass,
test control box, ball valves, flanges,gasket
etc. 100mm dia.
Supplying, Installation, Testing and
commissioning of 2 C X 1.5 Sqmm Copper
1.42 90 Armoured for Flow Switch Cabling from 122.88 Mtr
Announciation panel to Flow Switch.
SITC of 5 HP sewage pump for the
basement designed for liquids which are
non-aggressive and non-explosive, sewage
/ effluent water with solids or fibers, pump
shall have non clog, semi open or closed
type impeller with material of construction of
cast Iron FG260, CF8 AND CF8M, stainless
steel shaft, suitable for pumping liquid up to
50 degree C. The Pump shall be supplied
with double mechanical shaft seal with
material of construction of SiC
2 /SiC/Viton/S.S 316 at the pump end , close 60797.00 No
coupled with dry submersible motor, having
class F insulation, IP 68 protection, epoxy
sealed cable entry, with S1 duty for fully
submerged and S3 duty for partially
submerged, suitable for 3 phase, 415volts,
50 Hz power supply, All cast iron parts shall
be CED (cathode electrode deposition)
coated for corrosion resistance with uniform
coating and controlled deposition thickness
of 20-30 microns. The pump has 1500-
LPM at 5.8-16.2 Mtr head with 1450RPM.
SUB-TOTAL OF FIRE HYDRANT System
2 FIRE EXTINGUISHERS
FIRE EXTINGUISHER Supplying,
Installation, Testing and commissioning of
Dry Chemical Powder (DCP) 6 Kg Fire
Extinguisher Mono Ammonium Phosphate
Powder 40, Stored Pressure Type,
2.1 6 Pressure Gauge, Controllable discharge 2724.25 No
mechanism Class A, Rating 3A & Class B
rating 21B as per IS 15683 ISI MARK (ABC
Dry Chemical Powder - MAP 40%)fitted
with required accessories including wall
suspension brackets.
Supplying, fixing, testing and
commissioning of CO2 type Fire
Extinguisher of capacity 4.5 kg filled with
Co2 Gas as per IS 15222 with controll
discharge mechanismfitted with Hose &
Horn applicable on Class B fire rating 21B
confirms to IS 15683, bearing ISI mark.
Co2 Cylinder as per IS
Providing & fixing of ISI marked water CO2
type Portable fire extingusher,9 LTR
capacity, Hydraulic test pressure 35Kgf/
cm2, Discharge range 2 Mtr,Average
discharge time: Min. 13Sec,Fire Rating
3A,Grade: IS:15683.
Providing & fixing of ISI marked, Squeeze
Grip Cartridge Type water CO2 type
Portable fire extingusher,9 LTR capacity,
2.4 1 Hydraulic test pressure 35Kgf/ cm2, 4200.00 No
Discharge range 2 Mtr,Average discharge
time: Min. 13Sec,Fire Rating 3A,Grade:
Providing,fixing, testing and commissioning
of 10Kg Modular type fire extinguisher
having Nitrogen expellant ,ceiling
2.5 1 mounted,Sprinkler Nozzle is gas tight the 2950.00 No
release temperature is adjusted with
sprinkler imported bulb set at 57 degree C
or 68 degree C ,coverage area 4 to 5 sqmtr,
SUB TOTAL of FIRE EXTINGUISERS
3 FIRE DETCTION & FIRE ALARM SYSTEM
Supply, Installation, Testing &
Commissioning of Microprocessor based
Networkable Analogue Addressable Fire
Alarm Control Panel. The Panel shall be
compliant with EN54-2, EN54-4 and
approved by LPCB. The Fire Alarm Control
Panel shall have inbuilt 2 loops and
expandable capacity upto 8 loops. The
Panel must have Full colour 800 x 480 LCD
with resistive touch screen and automatic
backlight dimming. The Panel must also
have the capability to take Addressable
Intelligent Wired and Wireless Devices on
same loop. Each loop shall have a capacity
of 127 analogue Addressable devices and
127 Base sounders/Base Sounder
Beacons. The panel shall have an event log
of minimum 10,000 events @ 1 second
resolution, Filterable and Printable. The
Panel shall have Three access levels.
Panel shall support upto 5000 Cause &
Effects entries, with upto 20,000 inputs
controlling & 20,000 Controlling outputs
across the network. The Panel shall have
capability for Peer to Peer networking
through RS485 network card.
The Panel must have 4 inbuilt
programmable sounder circuits, each circuit
rated at 2.5A.The Panel must have inbuilt
programmable inputs and 5 inbuilt
programmable relay outputs. The Panel
shall have up to sub-addressable
programmable Inputs/Outputs via optional
RS485 COMMS serially connected
expansion cards. The Panel shall have
V AC power supply along with automatic
Battery Charger. The Panel shall be fully
expandable via common plug in loop driver
boards. The user shall have a choice of
using the panel with 5.25 Amp or
Amp power supply unit which is inbuilt in
the FACP and should be approved to
EN54-4. The Panel shall have configurable
via USB port to PC or memory stick. The
Panel shall have dedicated RS232 serial
port for optional printer. Approved by LPCB
SITC of Analogue Addressable Multi-
Sensor which is fully compatible with
Analogue Addressable Protocol,having
removable high performance chamber with
Twin fire LED's allow 360 degree viewing,
User selectable sensitivity modes 1% to
3.2 95 4.5% obs/m, Incorporate Optical and dual 3597.20 No
Heat elements, lock mechanism (sensor to
base), Electronically addressed,
Pulsing/non-pulsing controlled from panel.
Approved by LPCB & VdS. (Including Five
year free maintenance with guarantee)
SITC of Analogue Addressable Multi- Heat
Sensor which is fully compatible with
Analogue Addressable Protocol,having
removable high performance chamber with
Twin fire LED's allow 360 degree viewing,
User selectable sensitivity modes 0 to
degree Celsius, Incorporates Fixed
Temperature and Rate Of Rise Heat
elements, lock mechanism (sensor to
base), Electronically addressed,
Pulsing/non-pulsing controlled from panel.
Approved by LPCB (EN54: Part 5)
(Including Five year free maintenance with
SITC of sensor common mounting base,
includes stainless steel contacts, slim
profile - only 8mm, quick connection via
3.4 130 square cable clamps, facility for remote 354.20 No
indicator, Approved by LPCB (Including
Five year free maintenance with guarantee)
Supply,Instllation,Testing and
Commissioning of Fault isolator Module
capable of monitoring shorted loop circuit
3.5 13 and automatically restore communications 2477.10 No
when shorted conditions are corrected
(Including Five year free maintenance with
Supplying, installation, testing &
commissioning of response indicator on
3.6 10 surface/recessed MS Box having two LED, 193.20 No
metallic cover complete with all connections
etc as required.
SITC of Manual Call Point approved to
EN54-11:2001, Approved by LPCB Easy to
3.7 8 install, push-fit wiring terminals (Including 4191.75 No
Five year free maintenance with guarantee)
SITC of Analogue addressable loop
powered Base Sounder, variable sound
output 50 ~ 98 dB(A) (±2 dB(A)) output at
metre, 51 user-selectable tones (all tones
EN54-3 compatible), Auto shutdown feature
prevents noise-pollution, Approved by
LPCB & VdS (Including Five year free
maintenance with guarantee)
Supply, Installation, Testing and
Commissioning of Analogue Addressable
Single Input Module. which Includes a
3.9 5 single monitored input, flying leads for easy 3982.00 No
installation. Electronically addressed,
(conforms to EN54). as per tender
specification etc. as required.
Supply, Installation, Testing &
Commissioning of Analogue Addressable
Single Output Module . which Includes a
single output, flying leads for easy
installation. Electronically addressed,
Approved by LPCB & Vds.
Supplying & laying of 2x1.5 sqmm fire alarm
armoured cable, 600/1000V rated with
3.11 1050 annealed copper conductor having XLPE 135.70 Mtr
insulation, steel wire armouring & FRLS
outer sheath complete as required.
SUB -TOTAL OF FIRE DETECTION&
Annual Comprehensive Type
Maintenance Contract of for Above Fire
Fighting System For 1-Year DLP + ONE
Every six months Testing certificates
with Photographs should be sent to
competent authority by concern
Annual comprehensive Type Maintenance
4.1 1 Charges only During 1st Year DLP / Defect 0.00 Year
Liability period.
Annual comprehensive Type Maintenance
4.2 1 Charges for 1st Year after Guarentee / 134052.35 Year
Defect Liability period.
SUB TOTAL of Annual Comprehensive
Maintenance of Fire Fighting Sytem
LANDSCAPING WORK :
LAYING OUT LAWN – After excavating soil
upto 30 cm. depth & removing unwanted
stuff, stones etc. Preparing soil for planting
by supplying and mixing 6 inch river fine
site and 0.5 cmt FYM maximum 100 sqmt
of lawn area and doing termicide @ 1 fit /
100 sqmt area and planting selection 1 type
/ approved lawn grass at maximum 6 cm x
6 cm distance and maintain it upto
days. Maintainance include all operations
i.e. watering, grass cutting, gap filling,
applying of fertizer if require etc.
Supplying, Spreading and leveling of good
2 315 earth like firtile soil as directed etc compt. 575.00 Cmt.
Supplying, Spreading and leveling of good
3 70 quality river Kap Filling 100 mm as directed 575.00 Cmt.
Supply and Planting saplings of Hedge
plants like kadvi mahendi, karmda,
dyuranta, nikodeviya etc. specifies bag
size is 4 inch x 6 inch, well established &
free from disease at site. as per the
Supply and Planting saplings of Ficus
panda, Ficus benjamina, Ficus benjamina
variegated, Ficus longisland bag size is
inch x 13 inch, well branched, well
established & free from disease at site as
per the instructions
Supply and Planting saplings of (Jasud,
Ixora, Ticoma Gaudi-chaudi, Gultora,
Jetropha, Haemeliya, Chandani, Mogaro,
Galfemia, , Allamenda, Desi Gulab,
Euphorbia mili, Jasud Hybrid, Chandani
6 300 double, Madhukamini, Madhumalti, Ticoma 85.00 Nos
Capensis, Ixora draft, Nikadevia, English
Karen etc.) having height of minimum
to 2.5 ft. and bag size is 8 inch x 10 inch,
well branched, well established & free from
disease at site as per the instructions.
Supply and Planting saplings of Golden
Bamboo having height of minimum 5 to
7 100 ft. and bag size is 8 inch x 10 inch, well 45.00 Nos
branched, well established & free from
disease at site as per the instructions.
Supply and Planting saplings of Palm(Botal
palm,foxtel) having height of minimum
10.00 to 12.00 ft. and bag size is 21 inch x
21 inch, well branched, well established &
free from disease at site as per the
Supply and Planting saplings of champa
(deshi) having height of minimum 8 to
9 30 ft. and bag size is 15 inch x 16 inch, well 450.00 Nos
branched, well established & free from
disease at site as per the instructions.
Supply, Spreading and leveling of Brick
10 10 dust (Chharu) particle size having 1300.00 Cmt
Supply Saplings and Planting of trees
species as specified ( Alstonia scholaris,
Erythrina indica, Jacaranda
mimosifolia,Delonix regia , Anthocephalus
cadamba, Spathodea companulata,Neem
(Azadirachta indica), Lagerstromia
speciosa , Tabebuia argentea, Cordia
sebestena, Mimusops elengi, Bauhinia
blakeana, Kigelia pinnata, Cassia fistula,
11 120 Banyan, Ficus religiosa, Peltophoroum, 250.00 Nos
Bottle brush, Silver Oak, Billi, Mahagony,
Pendula, Desi Asopalav,Sevan, Badam,
Ficus infectoria, Pinkesiya, Millingtonia
hotensis, Rain Tree, Bakm limdi, kasid,
Ashok tree, parkia, Tabebuia Rosea,
millettia, etc.) having height of minimum
7.00 to 8.0 ft. and bag size is 13 inch x
inch, well branched, well established & free
from disease at site as per the instructions.
Supplying insecticides at site well packed
in bottle of 20 litre. weight including royalty
12 80 and carriage with all leads and lifts (product 300.00
to be brought in company sealed packing
Furniture (Table, Chair and Window
Supply of Midium back revolving chair
having denim blue color, 12 mm BWR
grade ply, L ply frame, 45 mm mold sheet
back, fibre base27" custer(Nylon), Hidrolic
Mechanism etc comp. As per sample
approved by department.
Supply of Officer Table( Single Mobile
Drower Unit) Size-66"x30"x30", 36 mm
post form Formika top and 42 mm post form
Formika side made from ISI grade MDF
board, wirh keyboard tray and apron,
Mobile Drower Unit- size, 18"x21"x27"
made from Post Form ISI grade MDF board
unit with three drower, handle, lock, high
quality channel. As per sample approved
Providing & Fixing in Position Vertical Roller
Blinds with Minimum 3 % and Maximum
% Light Transperace Screen Fabric
Incuding Providing & Fixing of Powder
coated G- Channel at the Topof Window
with necessary Screw , Cleats etc. and PVC
Roller ( Weight Pipe) and PVC Chain For
Up and Down Movement of Blinds etc. of
3 140 Approved Make and as per Drawings / 1372.03 Sq.mt.
Instruction of Engg. in Charge For All
Colors and Shades. Rates Includes all Lead
and Lift For All Floor Level, All Height , All
Material , Accessories, Fixing , Scaffolding
Labor etc. Complete in All Respects. All
Required Accessories & Material must be
From Same Manufacturer.
Providing & Fixing Sun Control Reflective
Type Film / Frosted Film as Selected by
4 140 Architect/ Engg. In Charge For Glass Doors 646.37 Sq.mt.
/ Windows etc. as Directed.
Signature of Bidder
Special Condition For Tenderers
• Scope includes Complete Demolition of Super Structure & Sub Structure up to
Foundation Level of Existing Old Buildings in the Said Plot Under Development as
Instructed by Engg. In Charge & Then Disposal of Serviceable & Un Serviceable
Material including Cleaning & Levelling of Entire Plot. The Total Project Includes
Demolition of Existing Units and Site Clearance. The Total Responsibility and
Liability of This Demolition Works Including Site Clearance Shall Be of The
Contractor. This Demolition and Debris Removal Includes all Hidden Foundation
also at Locations Where New Foundation or New Work is To Be Done.
• Contractor Has to Visit Site with representative of A.M.C. Before Quoting Amount in
Tender. The Contractor Shall Not Be Paid For Any Dismantling, Demolition, Carting
The Debris And/ or Any Expenses Incurred For Site Clearance.
• Contractor shall have to Pay Premium Amount to A.M.C. For Disposal of Serviceable
Goods Like Old Reinforcement, Old Wooden Doors/Windows, Iron Work,
Copper/Alu. Wiring, Bricks etc. Which shall be Quoted in Part-A of Financial Bid.
• For Consideration of Lowest Eligible Bidders , Premium Amount as Mentioned
Above i.e. Part-A shall be Deducted From e-Tender Amount For Construction Work
i.e. Part-B , Quoted by the Contractors.
• The Lowest Eligible Bidder shall have to Deposit Premium Amount for the
Serviceable Goods at the Time of Submission of Security Deposit.
Signature of contractor Additional City Engineer (NORTH ZONE)
Seal Ahmedabad Municipal Corporation
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- NORTH ZONE
Name of Work : CONSTRUCTION OF INDULAL YAGNIK COMMUNITY HALL AFTER DEMOLITION OF OLD
HALL BUILDING AT F.P.NO. 192, T.P.S.NO. 12 ( ASARVA EXTENSION SOUTH ) IN BAPUNAGAR WARD,
NORTH ZONE, AHMEDABAD.
FINANCIAL BID (Online Only)
Demolition of Existing Structure
Sr.No. Description Amount
Quoted Premium Amount For Serviceable Material (Which is Payable to
1 A.M.C. at The Time of Depositing Security Deposit by the Lowest Eligible
Amount in Words Rupees :
Sr.No. Description Amount
1 Amount For Civil Work Rs.7,46,17,470.58
Amount For Electrical, Elevator & HVAC Work with Annual Operation &
Comprehensive Maintenance for 1 Years after completion of DLP of 1 Year Rs.1,67,03,144.45
Amount For CCTV Work with Annual Operation & Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
Amount For Fire Fighting System Work with Annual Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
5 Amount For Landscaping Work Rs.
6 Amount For Furniture Work (Table Chair and Window Curtains) Rs.
I/We am/are willing to carry out work at ______% above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : Rs. 9,86,35,135.21 Estimated cost put to tender : Rs.
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Net Tender Amount For Consideration of Lowest Eligible Bidders
Sr.No. Description Amount
1 Net Amount For Cost of Civil , Electrical, Fire Fighting, O&M, Landscaping
and Interior & Furniture Work i.e. Part-B Rs.
2 Quoted Premium Amount Payable to A.M.C. i.e. Part-A Rs.
3 Net Tender Amount i.e. (Part-B -
Net Tender Amount in Words Rupees :
Signature of contractor Additional City Engineer ( N.Z. )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NZ INDULAL YAGNIK VOLUME 1A.pdf
NZ INDULAL YAGNIK NIT.pdf
NZ INDULAL YAGNIK VOLUME 1A.pdf
NZ INDULAL HALL Vol-1 Part B TS Civil Work Dt 09-06-2026.pdf
NZ INDULAL HALL Vol-1 part-C Electrical Specification.pdf
NZ INDULAL HALL Vol-1 part-D CCTV Work Specification.pdf
NZ INDULAL HALL Vol-1 part-E Fire Fighting Specification.pdf
NZ INDULAL HALL Final Price Bid Vol -II Dt-09-06-2026.pdf
TENDER DRAWING INDULAL YAGNIK HALL Dt 09-06-2026.pdf
Download all tender documents and submit your bid