Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.5 CrAccepted-AOC 201 3RD FLOOR A BLOCK SRI GURU TOWERS 80 FEET ROAD ANNA NAGAR MADURAI 625017 | MADURAI | TAMIL NADU | 625017 | ₹26.5 Cr Quoted ₹26.8 Cr | 1 | Accepted-AOC L1 offerer |
| 2 | 2₹26.8 CrRejected-AOC NO 1 PPS COMPLEX METTUR MAIN ROAD OMALUR TALUK SALEM 636455 | SALEM | SALEM | TAMIL NADU | 636455 | ₹26.8 Cr | 2 | Rejected-AOC L2 offerer |
| 3 | Rejected-Technical PLOT NO 178 A MLA COLONY ROAD NO 12 BANJARAHILLS HYDERABAD HYDERABAD TELANGANA 500034 | HYDERABAD | TELANGANA | 500034 | - | - | Rejected-Technical They have not complied with the tender eligibility criteria |
Tender Value
₹26.9 Cr
EMD Value
₹26.9 L
Closing Date
2 Mar 2023, 3:00 pmClosed
TCMPF Limited ,Aavin illam,Nandanam-35
TCMPF Limited ,Aavin illam,Nandanam-35
Construction of 60 MTPD Capacity Powder Plant at Padalur , Perambalur District
2023_TCMPF_282555_1
14130/Engg.3/2022
Open Tender
Civil Works
545 days
Padalur
refer tender document
9 documents required · 9 mandatory
₹0
₹26.9 L
Yes
TCMPF Limited ,Aavin illam,Nandanam-35
3 Aug 2023
20 Jan 2023
3 Mar 2023
20 Jan 2023
2 Mar 2023
3 Feb 2023
20 Jan 2023 - 2 Mar 2023
2 Feb 2023
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of back filling ,shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation and basement with filling Crushed stone sand in layers of not more than 15 cm thick well rammed watered and consolidated complying with std spec.
Supplying and filling conveyed gravel other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Cement Concrete 1:4:8 (One Cement, Four Crushed stone sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
Cement Concrete 1:5:10 (One Cement, Five Crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete (The crushed stone sand to be used on concrete work shall confirm to gradation as per IS 383-1970)
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Brick work in following Cement Mortar 1:5 using best quality II class table moulded chamber burnt bricks of size 9" x 4-1/2" x 3" for foundation and basement including curing, etc., complete complying with standard specifiction. In Cement Mortar 1:5 For Foundation and Basement.
For Superstructure in 0 - 4.5m level
For Superstructure in 4.5 - 9m level
For Superstructure in 9 - 13.5m level
For Superstructure in 13.5 - 18m level
For Superstructure in 18-22.5m level
For Superstructure in 22.5-27m level
For Superstructure in 27 - 31.5m level
For Superstructure in 31.5-36m level
For Superstructure in 36-40.5m level
For Superstructure in 40.5-45m level
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete. below basement - plain surface
below basement - vertical surface
below basement - Wall surface
above base - 0 to 3.30 m plain surface
above base - 0 to 3.30 m vertical surface
above base - 0 to 3.30 m Wall surface
3.30 m to 4.30 m - plain surface
3.30 m to 4.30 m - vertical surface
3.30 m to 4.30 m - Wall surface
4.30 m to 5.30 m - vertical surface
4.30 m to 5.30 m - Wall surface
5.30 m to 6.30 m - plain surface
5.30 m to 6.30 m - vertical surface
5.30 m to 6.30 m - Wall surface
6.3 m to 7.3 m - vertical surface
6.3 m to 7.3 m - wall surface
7.3 m to 8.3 m vertical surface
7.3 m to 8.3 m Wall surface
8.3 m to 9.3 m plain surface
8.3 m to 9.3 m vertical surface
8.3 m to 9.3 m Wall surface
9.3 m to 10.3 m plain surface
9.3 m to 10.3 m vertical surface
9.3 m to 10.3 m Wall surface
10.3 m to 11.3 m vertical surface
10.3 m to 11.3 m Wall surface
11.3 m to 12.3 m vertical surface
11.3 m to 12.3 m Wall surface
12.3 m to 13.3 m plain surface
12.3 m to 13.3 m vertical surface
12.3 m to 13.3 m Wall surface
13.3 m to 14.3 m vertical surface
13.3 m to 14.3 m Wall surface
14.3 m to 15.3 m vertical surface
14.3 m to 15.3 m Wall surface
15.3 m to 16.3 m vertical surface
15.3 m to 16.3 m Wall surface
16.3 m to 17.3 m vertical surface
16.3 m to 17.3 m Wall surface
17.3 m to 18.3 m vertical surface
17.3 m to 18.3 m Wall surface
18.3 m to 19.3 m Plain surface
18.3 m to 19.3 m vertical surface
18.3 m to 19.3 m Wall surface
19.3 m to 20.3 m vertical surface
19.3 m to 20.3 m wall surface
20.3 m to 21.3 m vertical surface
20.3 m to 21.3 m wall surface
21.3 m to 22.3 m vertical surface
21.3 m to 22.3 m Wall surface
22.3 m to 23.3 m plain surface
22.3 m to 23.3 m vertical surface
22.3 m to 23.3 m wall surface
23.3 m to 24.3 m vertical surface
23.3 m to 24.3 m Wall surface
24.3 m to 25.3 m plain surface
24.3 m to 25.3 m vertical surface
24.3 m to 25.3 m wall surface
25.3 m to 26.3 m vertical surface
25.3 m to 26.3 m wall surface
26.3 m to 27.3 m vertical surface
26.3 m to 27.3 m wall surface
27.3 m to 28.3 m vertical surface
27.3 m to 28.3 m Wall surface
28.3 m to 29.3 m plain surface
28.3 m to 29.3 m vertical surface
28.3 m to 29.3 m wall surface
29.3 m to 30.3 m vertical surface
30.3 m to 31.3 m vertical surface
31.3 m to 32.3 m vertical surface
32.3 m to 33.3 m plain surface
32.3 m to 33.3 m vertical surface
33.3 m to 34.3 m vertical surface
34.3 m to 35.3 m vertical surface
35.3 m to 36.3 m plain surface
35.3 m to 36.3 m vertical surface
36.3 m to 37.3 m vertical surface
37.3 m to 38.3 m plain surface
37.3 m to 38.3 m vertical surface
38.3 m to 39.3 m vertical surface
39.3 m to 40.3 m vertical surface
40.3 m to 41.3 m plain surface
40.3 m to 41.3 m vertical surface
Providing of placing RMC Cement Content 360 Kg/Cum Reinforced Cement concrete of the following grades using OPC 53 grade cement, machine crushed coarse agrregates 20 mm and 12.5 mm, M sand, Water and admixture etc complete all for casting concrete elements of all shape and size and at all heights. For Foundation and Basement.
For Superstructure in 0 - 4.5m level
For Superstructure in 4.5 - 9m level
For Superstructure in 9 - 13.5m level
For Superstructure in 13.5 - 18m level
For Superstructure in 18-22.5m level
For Superstructure in 22.5-27m level
For Superstructure in 27 - 31.5m
For Superstructure in31.5-36m level
For Superstructure in36-40.5m level
For Superstructure in 40.5-45m level
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification
Brick partition walls of 11.50cm thickness using best quality II class table moulded chamber burnt bricks of size 9" x 4-1/2" x 3" in Cement Mortar 1:3 (One Cement and Three M.Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) For Superstructure in 0 - 4.5m level
For Superstructure in 4.5 - 9m level
For Superstructure in 9 - 13.5m level
For Superstructure in 13.5 - 18m level
For Superstructure in 18-22.5m level
For Superstructure in 22.5-27m level
For Superstructure in 27 - 31.5m
For super structure 31.5-36m level
For super structure 36-40.5m level
Supplying and fixing mild steel grills for windows, ventilators, etc., including priming coat etc., complete.
Fabricting Supplying and fixing in position Aluminium anodised Natural color matt finish door of size 1.00mx2.10m with 12mm thick bothside prelaminated particle board at bottom w& 2/3 glazed using 5.50mm thick Plain glass at top with aluminium grill 10mm thick double leaves door. The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section with Vertical & Top rail: [email protected] kg/m, Bottom rail: 100x44.45x2.50mm@ 1.974 kg/m,Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 kg/m and Fixed ventilator Inner frame of section @ 63.50x38x3mm @ 1.72kg/m and necessary accessories such as rubber beading PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2Nos, aluminium tower bolt 200x12mm - 1No, aluminium door stopper with rubber bush - 2Nos ., lock-1No.,Hydraulic Door closer as per BIS standards including cost of all materials, labour charges and power consumption charges required for fabrication including chipping dismantling and making holes to the required extent in RCC in column/beam/masonry with power drill wherever neccessary and redoing the damaged portion to the original condition after fixing etc. complete.. All Aluminium section shall be used in electrically controlled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete. . a) Single leaf
Fabricting Supplying and fixing in position Aluminium anodised Natural color matt finish door of size 2.00 m x 2.10m and 1.50m x 2.10m having fixed ventilator at top of size 1.50x0.30m with 1/3 panelled with 12mm thick bothside prelaminated particle board at bottom w& 2/3 glazed using 5.50mm thick Plain glass at top with aluminium grill 10mm thick double leaves door. The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section with Vertical & Top rail: [email protected] kg/m, Bottom rail: 100x44.45x2.50mm@ 1.974 kg/m,Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 kg/m and Fixed ventilator Inner frame of section @ 63.50x38x3mm @ 1.72kg/m and necessary accessories such as rubber beading PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 2Nos, aluminium tower bolt 200x12mm - 1No, aluminium door stopper with rubber bush - 2Nos ., lock-1No.,Hydraulic Door closer as per BIS standards including cost of all materials, labour charges and power consumption charges required for fabrication including chipping dismantling and making holes to the required extent in RCC in column/beam/masonry with power drill wherever neccessary and redoing the damaged portion to the original condition after fixing etc. complete.. All Aluminium section shall be used in electrically controlled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc., complete.. Double leaves
Supplying , fabricating and fixing in position Aluminium powder coated brown shade finish Four track sliding window in all floors with Aluminium sections of outer frame Bottom Track [email protected] kg/m,Top & vertical 92.34x29.70x1.50 at 1.066 kg/m,and Shutter Vertical 39x20x1.50 at 0.493 kg/m, Top & Bottom 18x36.6x1.50at0.439 kg/m, Vertical locking arrangement 28.94x39x1.50at0.632 kg/m with necessary accessories such as rubber beadings, special hinges, lock, handle including supplying and fixing 4mm thick plain glass including cost of all materials , labours, power consumption required for fabrication , drilling holes in RCC colunm, slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing and also as directed.The aluminium sections are to be anodised with matt finish under electrically controlled in accordance with IS 1868 / 1962 for an average anodic film thickness 15 microns etc., complete.
Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept. Officials.) Design the framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere
Accessories: Brackets made of CRCA powder coated / electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement. Polyurethane brackets should be used to connect horizontal section to vertical sections. Silicone: Natural cure, with good UV resistance to be used. The above frame should be fixed to brick / concrete masonry by using nylon self-expanding cap and driving MS electro plated 80mm long screws into the caps through frames. Glass: 5mm reflective Saint Gobain OR equivalent.
Providing and fixing in position interlocking rolling shutters of approved make of 18 gauge, 75 mm wide cold rolled, MS Lathe interlocked through entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with bracket including top cover, spring, axles, guide rails, tees, iron pulleys, bearings, handles, arrangements for inside and outside locking, holding-down bolts / MS lugs embedded in CC 1:2:4 including 2 or more coats of first quality synthetic enamel paint of approved make, over a coat of primer etc. complete as directed. (Measurements to be considered for payment shall be the clear size of opening plus guide channels on both sides for width and 450mm on top for drum height) for providing and fixing in position interlocking rolling shutter partly grilled and mechanically operated with mechanical device chain and crank operated with pair of handles etc complete as directed
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Plastering with Cement Mortar 1:5 (One cement and M.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the Engineer-incharge.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge.
Prepare surfaces and plaster with CM 1:5 (1 cement: 5 fine sand) 17mm thick(12mm+5mm) to all exterior faces of walls including hacking as required on RCC surfaces continuous to masonry in super structure and 12mm will be rough plastering includes water proofing chemical compound and 5mm will be sand paper finishing & double layer chicken mesh .The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new wood/iron work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 6 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification.160mm dia PVC Rain water Pipe
Providing and fixing anodized aluminium fixed type partition fabricated out of extruded sections confirming to BIS IS 733 as detailed in the drawing of specified size and shape with anodizing 20 micron thick including supplying and fixing the frame and sub frame with expansion bolts / screws, necessary cleats for jointing with cadmium coated screws/ bolts nuts including providing and fixing 6 mm thick toughened glass with EPDM gasket felt etc complete as per drawing and as directed.
Providing, fabricating and fixing in position M.S. Structure made out of M.S. rolled/hollow (rounds/rectangular/ square etc.) sections as per architect’s details including shearing /cutting, riveting, welding, grinding to smooth surface of all works, MS fixing holdfasts / anchor bolts to be grouted in concrete 1:2:4 , providing and fixing nuts bots fasteners as required as per architect’s details, including painting with two or more coats of first quality synthetic enamel paint of approved quality and make over a coat of primer etc. complete as directed. ( MS standard section shall be measured and paid under relevant Item. Nuts, bolts, washers shall be deemed to have been included in the unit rates and nothing extra shall be paid for)
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
Supplying and fixing superfine polished Ruby red or equivalent colour Granite slab 20 mm thick for Lift facia with bullnose edges are set in CM 1:3 10mm thick for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying & pointing curing etc. complete
Supplying and fixing pre polished Ruby red or equivalent colour Granite slab 18mm to 20mm thick for stair case riser set in CM 1:3 20mm thick for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying
Providing and laying polished machine cut single piece green Kota stone of uniform shade in required size as per drawing 20 to 25 mm thick for treads, risers, sides of staircase over 20 mm thick cement mortar bed of CM 1:4 (1 part cement :4 part of coarse M.sand) with thick cement slurry including making 3 to 5 mm V shaped grooves if required, curing machine / hand, curing, grinding, polishing, wax polishing etc complete as directed.
Providing the floor with 20 mm thick Granite slabs of approved colour and size in all floors over a base layer of 20 mm thick CM 1:3, the granite slab be laid over the cement mortor by applying white cement slurry in between base mortor and granite slab. The granite slabs are to be so laid that there should not be any gap inbetween the adjacent slabs and the joints shall be in line with another joint and uniform by using cutting machine without any damage to the sides of corners of the granite slab. The entire area of the flooring so laid shall be neatly pointed with coloured cement of 1.80 kg/m2. The granite slabs proposed for the work shall be shown to the departmental officers and got approved by them before use in the work etc., complete.
Providing the floor with 30 mm thick Unpolished Granite slabs of approved colour and size in all floors over a base layer of 20mm thick CM 1:3, the granite slab be laid over the cement mortor by applying white cement slurry in between base mortor and granite slab. The granite slabs are to be so laid that there should not be any gap inbetween the adjacent slabs and the joints shall be in line with another joint and uniform by using cutting machine without any damage to the sides of corners of the granite slab. The entire area of the flooring so laid shall be neatly pointed with coloured cement of 1.80 kg/m2. The granite slabs proposed for the work shall be shown to the departmental officers and got approved by them before use in the work etc., complete.
Providing the floor with 50 mm thick Unpolished Granite slabs of approved colour and size in all floors over a base layer of 20mm thick CM 1:3, the granite slab be laid over the cement mortor by applying white cement slurry in between base mortor and granite slab. The granite slabs are to be so laid that there should not be any gap inbetween the adjacent slabs and the joints shall be in line with another joint and uniform by using cutting machine without any damage to the sides of corners of the granite slab. The entire area of the flooring so laid shall be neatly pointed with coloured cement of 1.80 kg/m2. The granite slabs proposed for the work shall be shown to the departmental officers and got approved by them before use in the work etc., complete.
Dadoing walls with following best approved quality, white / colour Glazed tiles of approved sizes set in Cement Mortar 1:2 (One Cement and Two M.sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Paving the floor with best quality Virtified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M.sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed
Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed.
Providing fabricating and installing in position Stainless Steel 304 sheets for cladding and anchored to corners of columns L shape 50 x 50 size through shaped custom fabricated etc as per the drawings including all fixing accessories, all cutting, bending, welding, grinding, and all other incidentals and approved buffing to stainless steel members etc. complete as directed.
Supplying & laying of sun reflective index tiles 305 x 305 x 7 mm of 30 mm thick in cement mortar 1:3, 30 mm thick using white cement and hard crate mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Surface Preparation:- Providing and grinding all sharp edges to make it flush with the surface, cleaning all floor, walls areas to make it free from debris, dirt, dust and other contaminants, etc and complete as per manufacturer's specification. Construction joints treatment - Providing and supplying E 135, SBR based admixture and polymer bonding agent, for filling CM 1:4 (fine M.sand) admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, including cut opening the joints in the form of "V" shape of required size, cleaning the grooves, applying neat coat of E 135, filling the groove with mixed mortar and finishing, curing, etc and complete as per manufacturer's specification. Horizontal bore packing - Providing and supplying E 135, SBR based admixture and polymer bonding agent, for filling the gap between the wall and pipe using CM of required mix ratio admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, over the neat coat of E 135, including cleaning, filling - compacting in the horizontal bore holes, finishing the mortar flush with the surface, curing, etc and complete as per manufacturer's specification. Waterproofing Membrane: Providing and applying two coats of Ardex WPM 004, two components, two components, breathable, acrylic elastomeric waterproofing coating in two coats with dft 0.8 - 1.0 mm thick using brush/roller leaving each coat to dry completely, applying first coat of WPM 004, sandwiching WPM Deck Web at all corners and pipe penetration on the wet first coat of WPM 004, applying second coat of WPM 004 and allowing it to dry, etc and complete as per manufacturer's specification. [The properties are:- Pot life : 60 min; Appearance : Grey colour fluid liquid; Mixed material density : 1-65 - 1.7 Gms / CC; Bond strength : 0.90 N/Sqmm; Depth of water penetration : >21mm, crack bridging upto 1 mm, flexible]. Screed for Floor - Providing and supplying of E 135, SBR based admixture and polymer bonding agent, for installing screed with required thickness using CM of required mix ratio admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, over the tacky bonding slurry of E 135, water and cement mixed in ratio of 1:1:3, including cleaning the surface, installing level buttons, applying the mixed mortar, compacting, leveling, curing, etc and complete as per manufacturer's specification. Plastering - Providing and supplying of E 135, SBR based admixture and polymer bonding agent, for installing plastering using CM of required mix ratio admixed with E 135 at dosage of 2.5 Ltr per 50 Kg bag of cement, over the tacky bonding slurry of E 135, water and cement mixed in ratio of 1:1:3, including cleaning the surface, installing level buttons, applying the mixed mortar, compacting, leveling, curing, etc and complete as per manufacturer's specification.
Providing and laying 125mm thick Vacuum De-watered of M25 grade concrete ( Seprate design mix for VDF flooring) with minimum cement content of 360kg/cum, surface vibrated and finished with machine for flooring over prepared sub-base in strips of width up to 3.5 M in line and level maintaining required slope , compacting with needle / surface vibrator, leveling with surface vibrator, Vacuum De-watering with vacuum pump, floating and further compaction with skin floater equipped with floating disc, providing and spreading Rockite or equivalent floor hardener @ 3.5 Kg/Sq.M, curing, formation of joints @ 4 M c/c (maximum) by cutting up to 25mm thickness of concrete slab with mechanized saw and filling the same with semi-rigid epoxy based Rockite or equivalent sealant including preparation of base, curing finishing etc. with required 12mm MS dia bar on all edges 300mm on both pannel @ 300mm c/c, curing etc complete as per the drawing / as directed by Engineer.
Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse M.sand:6 graded stone aggregate 20 mm nominal size) well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge.
Providing and fixing in position precast R.C.C. manhole cover and frame.Square shape 600mm internal dimensions
Providing and fixing PVC coated MS rungs as per drawing and instruction of Engineer in-charge complete.
Supply and installation of Anutone (or) Euivalent Brand of Acoustical False Ceiling of subtex nubby, square edge, glass fibre core fully encapsulated ceiling tile of size 595 x 595 x 15mmhaving volume density 120 Kgs / m3, weight 1.8 / 2.4 / 3 kg /m2 which is suspended by using 0.3mm thick skelet trelis T15metal grid system. Skelet trelis T15 metal grid system of 600 x600mm module includes skelet WA15 W30 wall angle withunequal flanges of 15 / 19mm, length 3000mm, fixed along theperimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15W36 MainT with flange width 15mm, height 32mm and length3600mm, from the soffit slab with help of soffit cleat and wirerod with leveling spring clip at 1200mm centres. Skelet CT15 W12 CrossT with flange width 15mm, height 26mm and length1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally, the skelet CT15W06 CrossT with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600 x 600mm module. The subtex nubby square edge of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. The systems to achieve noise reduction coefficient not less than 0.9 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, scaffolding, transportation, conveyance, etc. complying to standard specication.
Supplying and fixing colour galvanum sheet roof of 0.47mm thick in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers.
SANITARY;Supplying and fixing of Oval Shape Wash Hand Basin of size 560 x 450mm with all accessories such as 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia 'B' Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc
Supplying and fixing Stainless Steel Sink of size 600mm x 450mm x 200mm with 32mm dia 'B' Class GI Waste Water Pipe and 32mm dia CP Waste Coupling
Supplying and fixing of Granite Sink of size 600 x 600 x 250mm with 32mm dia 'B' Class GI Waste Water Pipe and 32mm dia CP Waste Coupling
Supplying and fixing SS Swan Neck Tap for lab sink
Providing and fixing liquid soap dispenser of approved make fixed with necessary fittings etc. complete as directed.
Supplying and fixing approved make C.P. towel ring with necessary fixing materials
Supplying and fixing approved make C.P. towel rail 600mm long with necessary fixing materials
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) Nahani Trap of size 100 x 75mm with stainless steel gratings
Providing and fixing factory made grade SS 304 deep seal ' P' trap / Amul Trap 300x300mm in single piece without side joints of self cleansing design with or without vent arm with provision for connecting inlet fitting complete including cost of cutting and making good the walls and floors wherever required for 100mm inlet and 100mm outlet.. The trap shall be connected to HDPE pipe etc complete as directed.
Providing & Fixing HDPE pipe 4 kg pressure 4984 PE 80 with welding, all fitting such as bend, tee, reducer etc complete. HDPE pipe 110mm
HDPE pipe 160mm
HDPE pipe 200mm
HDPE pipe 250mm
HDPE pipe 315mm
Providing & Constructing 1.0 M x 1.0 M (inside dimension) and 1.0 M to 1.5 M depth Manholes. The rate includes excavation, 150 mm thick BBCC 1:5:10 (1 part cement, 5 part coarse sand, 10 part of brick bat ) in foundation 230 mm thick brick masonry walls in CM 1:3(1 part cement, 3 part sand), 12 mm thick plastering in inside and top 300 on the external face of chamber in CM 1:5(1 part cement, 5 part sand), channels, IPS flooring, making drain channel as per specification, CI/MS rungs with paint, steps, CI cover 600 X600mm heavy duty, 150 mm thick RCC 1:2:4(1 part cement, 2 part coarse sand, 4 part of stone aggregate) slabs with standard reinforcement etc. complete as directed
.Providing & Constructing 1.2 M x 1.2 M (inside dimension) and 1.5 M to 2.0 M depth Manholes. The rate includes excavation, 150 mm thick BBCC 1:5:10 (1 part cement, 5 part coarse sand, 10 part of brick bat ) in foundation 230 mm thick brick masonry walls in CM 1:3(1 part cement, 3 part sand), 12 mm thick plastering in inside and top 300 on the external face of chamber in CM 1:5(1 part cement, 5 part sand), channels, IPS flooring, making drain channel as per specification, CI/MS rungs with paint, steps, CI cover 600 X600mm heavy duty, 150 mm thick RCC 1:2:4(1 part cement, 2 part coarse sand, 4 part of stone aggregate) slabs with standard reinforcement etc. complete as directed
Providing and constructing Inspection Chambers/ Manhole Chamber/ any other Chamber size 600 x600 mm x450mm to 1000mm deep including necessary excavation in soil/murrum/rock as per required invert level and working space all around, 150mm thick bed of cement concrete in proportion of CC 1:5:10 (1 part cement, 5 parts coarse sand and 10 parts of stone aggregates) with 150mm offsets at all around the outer faces of walls, providing and constructing of minimum 230mm thick brick/cement concrete block masonry walls in CM 1:4 (1part cement and 4 parts of coarse sand), providing and applying 15mm thick water proof plaster in CM 1:3 (1 part cement and 3 parts of coarse sand) added with integral waterproofing compound as per manufacturers specifications and finished with a floating coat of neat cement @ 2.2 Kg/SqM at the internal & external faces all around the masonry walls, necessary floor benching and channels in cement concrete 1:1.5:3 (1 part cement, 1.5 part coarse sand, 3 parts of stone aggregates) of minimum 150mm thick rendered smooth with waterproof plaster followed by neat cement, providing CI circular/square Manhole cover with frame of minimum 600mmX600mm weighing minimum 40 kg (double seal) of approved make and confirming to IS and fixing with reinforced cement concrete 1:1.5:3 of minimum 150mm thick slab including shuttering, finishing the concrete surface and faces with waterproof plaster/IPS in mild slopes with float of neat cement etc complete as directed.
Providing and fixing square mouth 'P' type S.W gully trap grade ‘A‘ of size 300x300mm complete with C.I grating, brick masonry chamber and water tight C.I cover with frame of 450 x 450 mm size. The weight of cover to be not less than 4.50 Kg and and frame to be not less than 4.70 Kg as per standard design and detail.
Supplying and fixing in position best quality UPVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using UPVC adhesives including fixing to the wall with special UPVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The UPVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level .75mm dia
110mm dia
160mm dia
Providing and laying non-pressure class NP2 RCC Hume pipes with collars including excavation of trenches in soil/murum/rock, laying the pipes as per layout and drawing, filling the joints with stiff mixture of cement mortar (1 part cement :1part fine sand) and jute, curing, testing the pipe and refilling the trenches in layers with due compaction & watering etc. complete as directedl 150mm dia
250mm dia
300mm dia
WATER SUPPLY ; Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. 50mm dia CPVC Pipe Above Ground level
40mm dia CPVC Pipe Above Ground level
32mm dia CPVC Pipe Above Ground level
25mm dia CPVC Pipe Above Ground level
20mm dia CPVC Pipe Above Ground level
15mm dia CPVC Pipe Above Ground level
Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works. 65mm dia upvc pipe
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 65mm dia
Providing and laying in position PCC pedestal on terrace for water supply pipes "1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size).
ELECTRICAL Supply, installation & commissioning of fabricated / readymade MCCB type electrical distribution board ( 6 WAYS 3 PHASE OUT GOING) flush type, indoor enclosure, hinged front cover, dust & vermin proof complete with switchgear given below and interconnection, as per detailed specification enclosed, along with powder coating painting. All MCCB with min 25 KA and MCB/RCCB/ELCB shall be of min 10 KA rupturing capacity. RCCB /ELCB shall have sensitivity of 300 mA. Detail of incoming & outgoing switchgear & component enclosed Incoming : 100 A 4P MCCB - 1 no, Outgoing : 63A TP MCB - 6 nos
LDB-Supply, installation & commissioning of electrical distribution board (THREE PHASE AND NEUTRAL, 6 WAYS 1 PHASE OUTGOING) flush type, indoor enclosure, hinged front cover, dust & vermin proof, fabricated out of 16 G mild steel sheets and complete with switchgear given below and interconnection, as per detailed specification along with powder coating. All MCB & RCCB/ELCB shall be of minimum 10 KA rupturing capacLty. RCCB /ELCB shall have sensitivity of 30 MA. (7 Segment). INCOMER : 63A, 4P, MCB - 1 NO., OUTGOING ; 63A , 2P, 30MA ELCB/ RCCB - 3 NOS ; 6/10A SP MCB - 18 NOS
PDB-Supply, installation & commissioning of electrical distribution board (THREE PHASE AND NEUTRAL, 6 WAYS 1 PHASE OUTGOING) flush type, indoor enclosure, hinged front cover, dust & vermin proof, fabricated out of 16 G mild steel sheets and complete with switchgear given below and interconnection, as per detailed specification along with powder coating. All MCB & RCCB/ELCB shall be of minimum 10 KA rupturing capacity. RCCB /ELCB shall have sensitivity of 100 MA. (7 Segment). INCOMER : 63A, 4P, MCB - 1 NO., OUTGOING ; 63A , 2P,100MA ELCB/ RCCB - 3 NOS ; 6/10A SP MCB - 18 NOS
Supply, installation & commissioning of fabricated / readymade MCB type electrical distribution board (SPN 8 WAYS) flush type, indoor enclosure, hinged front cover, dust & vermin proof, complete with switchgear given below and interconnection, as per detailed specification enclosed, along with powder coating painting. All MCB & RCCB/ELCB shall be of minimum 10 KA rupturing capacity. RCCB /ELCB shall have sensitivity of 300 mA. Detail of incoming & outgoing switchgear & component enclosed Incoming: 32 A DP MCB+RCCB, 1 No., Outgoing: 10 - 20 A SP MCB- 6 nos.
Supply and Laying XLPE insulated outer and inner PVC sheath, 1100 V grade, armoured copper conductor cable -size of cable 4X10 sq mm.
Supply and Laying XLPE insulated outer and inner PVC sheath, 1100 V grade, armoured copper conductor cable -size of cable 4X16 sq mm.
Supply and Laying XLPE insulated outer and inner PVC sheath, 1100 V grade, armoured Aluminium conductor cable -size of cable 4X25 sq mm.
Supply and Laying XLPE insulated outer and inner PVC sheath, 1100 V grade, armoured Aluminium conductor cable -size of cable 3.5 X 50 sq mm.
Supply and Laying XLPE insulated outer and inner PVC sheath, 1100 V grade, armoured Copper conductor cable -size of cable 3 X 6 sq mm.
TERMINATION 4C X 10 SQ.MM cu.AR.CABLE
4C X 16 SQ.MM cu.AR.CABLE
4C X 25 SQ.MM AL.AR.CABLE
4C X 50 SQ.MM AL.AR.CABLE
3C X 6 SQ.MM cu.AR.CABLE
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Secondary Light Points: Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Primary Light / Fan Point Wiring: Supply, wiring, connecting & commissioning of 3Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer's mounting box fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit and for Vertical and horizontal drops concealed PVC conduits can be used. Accordingly the length of the conduit can be calculated.
Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 3R 2.5SQMM COPPER WIRE
Ceiling Fan Points: Supply,installation,testing and commissioning of ceiling fan points same as Primary Light Point Wiring but for ceiling fan points including supplying and fixing concealed type fan hook box and supply and fixing of electronic type regulator
Providing and fixing/ laying of conduit and wires for Exhaust / Brackate fan point wiring with 1.5 sq. mm PVC insulated, FRLS, Cu. conductor (stranded) 1100V grade wires alongwith earthing in 25 mm dia. Medium duty PVC surface/ concealed conduit system including providing and fixing one no. modular 10A single way switch, grid plate mounted with moulded cover plate in zinc chromate passivated GI box suitable for modular switches complete in all respect ( wiring & conduiting up to switchboard not included in item cost). Including making zaries in the wall and finishing the same
Supply, fixing, testing and commissioning of 6A Universal (Flat type/Round type ) 5 Pin Raw Power Socket and 6A switch without modular box fixed in modular furniture in recessed system. (6A socket controlled by 6A Switch) for RAW power socket
Supply, fixing, testing and commissioning of 1 no of 6/16A Universal (Flat type/Round type ) 5 Pin Raw Power Socket and individual 16A switch with modular box. (6/16A socket controlled by 1 Switch)
Wiring to the 6A 5 Pin Raw power socket Universal (Flat type/Round type ) using 2 Runs of 2.5sqmm and 1 Run of 2.5 sqmm multi stand PVC insulated copper conductor (FRLS) in suitable size Rigid PVC pipe in open conduit system above false ceiling and concealed conduit system in below false ceiling in wall / column/floor etc.
Supply & Laying of 2R 4 sq.mm and 1R4 Sq.mm. PVC insulated FRLS multistranded cu wires with all accessories in pvc conduits as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.).
Supply & Installation, testing and commissioning of ceiling1200MM fan, with all standard accessories and connecting with 1.5 sq mm Cu. conductor PVC wires.
Supply &Installation, testing and commissioning of ceiling/ bracket fan, with all standard accessories and connecting with 1.5 sq mm Cu. conductor PVC wires. The standard hanging rod of ceiling fan to be replaced with new GI class `B' pipe up to 700 mm long. (including painting of new pipe)
Supply & Installation, testing and commissioning of ceiling/ bracket fan, with all standard accessories and connecting with 1.5 sq mm Cu. conductor PVC wires. The standard hanging rod of ceiling fan to be replaced with new GI class `B' pipe above 700 mm and up to 1500 mm long (including painting of new pipe)
Supply & Installation, testing & commissioning of exhaust fan up to 450 mm size with all accessories inculding opening in wall and connecting with 2.5 sq mm Cu. Conductor PVC flexible cable with flexible conduit from exhaust fan point.
Supply & Installation, testing and commissioning of 40 W LED water proof lighting fixture directly on ceiling/ beams/ walls / trusses etc. complete with all accessories . The item include supply of anchore fastners for fixing the Lighting fixture & connecting with 1.5 sq.mm Cu. conductor wires from light point.-crompton CIS-300-40-57-SL-DP-NGR or eqvt
Supply & Installation, testing and commissioning of 36w LED 2x2 lighter lighting fixture directly on ceiling. complete with all accessories . The item include supply of anchore fastners for fixing the Lighting fixture & connecting with 1.5 sq.mm Cu. conductor wires from light point. Crompton cat noLCT LRNE 36 FO CDL or eqvt
EXPRESS BAY -60-75W-LED high bay LIGHT WIPRO Wipro Enterprises (P) LED Highbay Luminaire (1.000) cat no LH15-102-090-57XX EQVT INCL CABLES TO PLUG OUTLET - FACTORY
Supply & Installation, testing and commissioning of 60W LED FLOOD lighting fixture directly on beams/ walls / trusses etc. complete with all accessories . The item include supply of anchore fastners for fixing the Lighting fixture & connecting with 1.5 sq.mm Cu. conductor wires from light point.WIPRO CAT NO LF19-711-060-57XX OR EQVT
Supply & installation of heavy gauge perforated Cable Tray made of SS, min1.2 mm thick, with sides not less than 50 mm deep, fittings are to be same material as tray, each coupling should have GI earthing connector, with suitable supports with bends & couplings to avoid sagging of the cable tray. The rate shall be inclusive of all other accessories, supports, rods & plates etc. Size 150 mm wide x 50mm depthX1.2MM
Supply & installation of heavy gauge perforated Cable Tray made of SS sheet steel, min 1.2 mm thick, with sides not less than 50 mm deep, fittings are to be same material as tray, each coupling should have GI earthing connector, with suitable supports with bends & couplings to avoid sagging of the cable tray. The rate shall be inclusive of all other accessories, supports, rods & plates etc. Size 300 mm wide x 50mm depth
Providing plate type earthing pit with GI plate (600X600X6.0 mm)electrode including all accessories, and civil work complete as per IS 3043-1987 latest revision, and as per sketch.
Providing and laying earth continuity conductor in ground/ on surface of building with necessary clamps as required, of size GI strip 25X6mm
Providing and laying earth continuity conductor in ground/ on surface of building with necessary clamps as required, of size GI strip 50X6mm
Providing and laying earth continuity conductor in ground/ on surface of building with necessary clamps as required, of size copper wire 8swg STREET LIGHTING -- MAIN ROADS The rate includes excavation and foundation for erecting the referred street light pole as required at site and inclusive of necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. each arm with light- The pole shall be grouted inside ground pit (cross section 600 x 600 mm) with cement concrete 1:2:4 with necessary GI ‘A’ class pipes (not less than 38 mm dia, NB) to facilitate pulling of cables. Separate pipes shall be provided for incoming and outgoing cables. The cement concrete shall be protected from premature drying by curing for at least seven days after pouring. All concrete surfaces from 150 mm below ground level to top shall be finished smooth with cement mortar 1:4.octagonal -pole height above ground - VALMONT - poles,with base plate size 260x260x16mm, 4nos foundation bolts,700 mm length 24mm dia.
Supply, erection, testing and commissioning of street light fitting with 1x120W LED lamp, driver, fixed on 7m (above ground) TUBULAR poles confirming to IS1161, - 1 m angle arm - decorative SINGLE arm VOLMANT cat no DELTA, or Hornbill or as per client choice -bracket for mounting fitting ,bracket assembly on to the pole top by means of angular rings , pedestal size 450x450mmwith reinforcement 8-Y12 WITH Y8@150c/c, pedestal 150mm above ground, base plate,ribs,4 fixing bolts Y10@150c/cBOTH WAYS, (700mm anchoring bolt with 90 degree bend, including red oxide paint 24mm rod with 2nos PL Washers and 3nos nuts) anchoring bolt,cable entry pipe, poles treated for corrosion protection, earthing arrangement, excavation and back filling, supplying and laying cables through Hansel make weather proof junction box with DP 3 amps MCB ,wiring with 3x2.5 Sq.mm PVC insulated 1100 volts grade copper conductor wires from junction box to lighting fixture complete as required. finish to be of approved colour.Entire application shall confirm to IS2713 for Tubular Steel Poles for Overhead Power lines including numbering of poles. 4 way 30 A rated terminal block for loop in & loop out cable arrangements coil earthing etc. The pole shall be painted with one coat of primer and two coats of enamel paint,with 1Mtr long 25mm dia 'B' class G.I. Pipe as earth electrode with charcoal ,Salt with 10SWG copper wire interconnected with street light pole. cable entry G.I pipe of 2.5" dia. as per Drg and Technical Specification.-CROMPTON CAT NO LSTP-120-WW-M-OR equivalent approved make
GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.)
PPSandCo
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid