Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC VILLAGE P O LANGHA VIKASNAGAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹41.0 L+₹2.3 L (5.86%)Rejected-Finance | L2 | Rejected-Finance Highest Rate Quoted by bidder | |
| 3 | L3₹42.0 L+₹3.3 L (8.59%)Rejected-Finance | L3 | Rejected-Finance Highest Rate Quoted by bidder |
Tender Value
₹43.3 L
EMD Value
₹87,000
Closing Date
15 Oct 2020, 5:00 pmClosed
Project Manager
Project Manager, Const. Unit, UKPJN, Dehradun
RENOVATION OF GOVT. GIRLS INTER COLLEGE RAJPUR ROAD DEHRADUN
2020_MDPEY_26460_1
1476/Nivida Suchna/107 dated 29/09/2020
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer tender doucment
3 documents required · 3 mandatory
₹2,360
PM, Const. Unit. UKPJN, Dehradun
₹87,000
14 Sept 2021
30 Sept 2020
17 Oct 2020
1 Oct 2020
15 Oct 2020
1 Oct 2020
Amount
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50metres lead as per direction of Engineer - in- charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150X10 MM
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m²
Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand and manufacture
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall 15 mm nominal Internal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Iinternal work - Exposed on wall 20mm nominal outer dia Pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : Every 5 Mtr. 15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tap
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing soil, waste and vent pipes IS 13592 & fitting (IS:14735) suitable to rubber ring joints, which includes bends, rubber ring, jointing, junctions, clean out plug, cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design, etc. complete including jointing. 100 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-B
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing soil, waste and vent pipes IS 13592 & fitting (IS:14735) suitable to rubber ring joints, which includes bends, rubber ring, jointing, junctions, clean out plug, cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self cleansing design, etc. complete including jointing. 75 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type - B
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm diameter pipe
Providing and fixing plain bend of required degree. 100 mm diameter pipe
Providing and fixing plain bend of required degree. 75 mm diameter pipe
Providing and fixing floor drain points formed out of 65 mm dia PVC ,elbow, including with 75mm dia Stainless Steel grating with frame, embedded in floor, all complete as directed.
Providing and fixing collar : P.V.C. 100 mm
Providing and fixing collar : P.V.C. 75 mm
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: White glazed fire clay kitchen sink of size 600x450x 250 mm
Providing and fixing of Nahani trap
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : v
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum moisture resistant board
Wiring for light point/ Fan point/ Exhaust fan point/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cablein surface/ recessed PVC conduit with piano type switch phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with one no. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2x2.5 sq.mm+1x2.5 sq.mm earth wire.
a. Sub main 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
b. Sub main 4 X 10 sq. mm + 2 X 10 sq. mm earth wire
Supplying and fixing 5/6 amps piano type switch on the existing switch box/ cover including connections etc. as required.
Supplying and fixing 3 pin 5/6 amp socket outlet on the existing switch box/ cover including connections etc. as required.
Supply and fixing metal box of 180mmx 100mm x60 mm deep ( Nominal size) on surface of in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supply and fixing suitable metal box 150 mm x 75 mm x 60 mm deep with modular plate & cover on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc. as required.
Supply and fixing 3 pin, 5 amp. Ceilling rose on the existing junction box/ wooded block including connection etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation, testing and commissioning of pre- wired, fluorescent fitting/ compact fluorescent fitting of all type, complete with all asccessories and tube etc. directly on celling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation,testing and commissioning of celling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation and fixing of stepped type electronic fan ragulator on the modular plate switch including connection but excluding modular plate etc. as required.
Supply and fixing following way, Three pole and neutral, prewied, sheet steel, MCB disribution board,415 volts, on surface/ recess.complete with loose wire box, terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor up to terminal block, tinned copper busbar, neutral ink, earth bar, din bar, detachable gland plate, intercnnections, phosphatized and powder painted including earthing etc. as required ( But without MCB/RCCB/ lsolator.) (b) 4 way (4+12) Double Door
Supply and fixing following way, Three pole and neutral, prewied, sheet steel, MCB disribution board,415 volts, on surface/ recess.complete with loose wire box, terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor up to terminal block, tinned copper busbar, neutral ink, earth bar, din bar, detachable gland plate, intercnnections, phosphatized and powder painted including earthing etc. as required ( But without MCB/RCCB/ lsolator.) 6 way (4+18) Double Door
Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C" series, minature circuit baeaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required. Single Pole.
Supplying and fixing of 63 Amp FP MCB, 415 volts, in the existing MCB DB complete with connection, testing and commissioning etc. as required.
Earthing with G.I. earth plate 600 mmx600mmx6 mm thick including accssories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
Supplying ans laying 25 mmx5mm G.I. strip at 0.40 metre below ground as strip earth electrode, including soldering etc. as required.
supply and fixing of floor sub panel
Supply of AC 230/250 volts, 50 Hz energy efficient ceiling fan with standard down rod, blades, 2 nos. caps etc. complet in all aspects as per direction of Engineer in charge (1400mm sweep)
S. M. Builders
M/S Shiv Shakti Construction Co
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .