Loading…
Loading…
Tender Value
₹24.6 L
EMD Value
₹25,000
Closing Date
1 Jun 2026, 6:00 pmClosed
Executive Engineer, Panchayat Road and Building Division, Morbi
Construction of Community Hall and Compound Wall at Various Village of Taluka Wankaner (Under MP Grant Yr-2025-26) Tal. Wankaner Dist. Morbi (Thikariyala Village,Kerala Village and Chandrpur Village )
307647
67 / 2026
Open
Civil - All
Works
Morbi
7 documents required · 7 mandatory
₹900
Executive Engineer, Panchayat Road and Building Division, MORBI
₹25,000
22 May 2026
22 May 2026
22 May 2026
1 Jun 2026
22 May 2026
Name of Work :-Construction of Community Hall & Compound Wall at Various Village of Taluka Wankaner (Under
MP Grant Yr-2025-26) Tal. Wankaner Dist. Morbi (Thikariyala Village,Kerala Village & Chandrpur Village )
Bill of Quantities
Memorandum showing items of works to be carried out
Item Discription of Item (With Brief Specification and reference to Quantity Unit Rate In Amount
No. book of Specification) Figures
In Figure Rs. Ps
1 Excavation for foundation upto 1.50 M.depth including sorting out 38.00 Cum 157.13
&stacking of useful materials i.e. dispositing the excavated stuff up
to all lead & lift (a)Dense or Hard soil.
2 Excavation for foundation upto 1.50 M.depth including sorting out 69.00 Cum 267.08
&stacking of useful materials And dispositing the excavated stuff up
to all lead & lift ©Hard Murrum
3 Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse 18.00 Cum 2932.73
sand : 8- machine crushed stone aggregates 40 mm nominal size)
and curing complete excluding cost of formwork in (A) Foundation
4 Providing and laying ordinary cement concrete1:1.5:3 (1cement,1.5 7.20 Cum 8804.10
sand, 3 gradedstone aggregates 20 mm.Nominal size) and
finishing smooth with curing etc. complete excluding cost of form
work and reinforcement for reinforced cement concrete work in in A)
Foundations, footings, base of columns and mass concrete
5 Providing and laying ordinary cement concrete1:1.5:3 7.40 Cum 10914.49
(1cement,1.5sand, 3 gradedstone aggregates 20 mm.Nominal
size) and finishing smooth with curing etc. complete including the
cost of formwork but excluding the cost of reinforcement of R.C.C.
work in Column (iii) Having cross-sectional area more than
Sq.M. and up to 0.18Sq.M.
6 Brickwork using common burnt clay building brick shaving crushing 20.00 Cum 4214.33
strength not less than 35 Kg/Sqcm. in foundation and plinth in
cement mortar 1:6(1 Cement ; 6 Fine sand) Conventional bricks
7 White Stone Bela mesonry block in course in superstructure with 101.00 Cum 6479.68
stone of approved quality in Lime Mortar 1:6 (1-Cement : 6- course
sand) including packing the joints etc. complete.
8 Filling in foundation and plinth with murrum or selected soil in layers 42.00 Cum 301.78
of 20cm. thickness including watering, ramming and consolidating
9 Brickwork using common burnt clay building brick shaving crushing 42.00 Cum 4496.05
strength not less than 35 Kg/Sqcm. in super structure Upto All floor
level in cement mortar 1:6(1 Cement ; 6 Fine sand)
10 Providing and laying cement concrete1:1.5:3 (1cement,1.5sand, 3 0.80 Cum 7186.78
gradedstone aggregates20 mm.Nominal size) and curing complete,
including cost of formwork in sill and sides (R.C.C. band) but
excluding the cost of reinforcement upto All floor level
11 Providing & laying ordinary C.C. 1:1 1/2:3 ( 1 cement ,1 1/2 course 1.20 Cum 10589.02
sand, 3 graded stone agg. of 20 mm nominal size )and for R.C.C.
LINTELS incl. Finishing smooth with curring of formwork but excl.
the cost of reinforcement.for above floor upto All Floor level.
12 Providing & laying cement concrete 1:11/2:3 (1 cement ,11/2 1.40 Cum 7042.78
course sand,3graded stone agg.of 20 mm nominal size) for rein-
forcement concrete CHHAJJAS not exceeding 10cm. thickness upto
floor two level incl. finishing the exposed surface with C.M. 1:3 (1
cement ,3 fine sand) to give a smooth and ever surface, centering,
formwork and curring comp.Excl. the cost of reinforcement.above
plinth Upto All floor level.
13 Providing & laying C.C. 1:11/2:3 (1 cement ,11/2 course sand,3 14.20 Cum 6948.11
graded stone agg.of 20 mm nominal size) and finishing smooth with
curring etc. comp. incl. the cost of formwork but excl. the cost of
reinforcement for R.C.C. work in. (A) Beam :- Having cross
sectional Area 0.085 to 0.12 Sqm.upto All floor level
14 Providing & laying ordinary cement concrete1:11/2:3 (1 cement 12.00 Cum 4659.23
,11/2 course sand,3 graded stone agg.of 20 mm nominal size)
exposed work with curring etc.comp. incl. the cost of formwork but
excluding the cost of reinforce ment for R.C.C. work in. SLAB :-
having more then 10cm. and end upto 13cm. thickness.upto All floor
15 Providing and laying cement concrete 1:5:10 (1- Cement : 5- Coarse 9.00 Cum 2606.92
sand : 10- hand broken stone aggregates 40 mm nominal size) and
curing complete excluding cost of formwork in (A) Foundation and
16 Providing TMT Bar FE 500/500D reinforcement for R.C.C. work 5542.00 Kg 77.29
including bending, binding and placing in position complete upto All
17 Providing and laying cement concrete 1:1.5:3 (1- Cement : 1.5- 5.06 Cum 4870.28
Coarse sand : 3- crushed stone aggregates 20 mm nominal size)
and curing complete including cost of formwork in (A) Wall Caps /
18 Providing and laying Green marble (18 mm thick ) in Jambs & Sills 13.60 Sqm 1671.55
of Windows and pillers laid on 10 MM thick cement mortar 1:3
(using Sulphate Resistant Cement) (1 Cement - 3 -coarse sand) laid
and jointed with grey cement slurry including rubbing and polishing
19 Providing and fixing 35mm. Thick Panelled,glazed orPanelled and 5.00 Sqm 3916.09
glazed shutters for doors,windows andclearstory windows including
anodised alluminiumbutt hinges with necessary screws and Indian
TeakWood shutters with-(B) Partical board panells.12mm. thick
including applying primer and two coats of oil painting etc. complete
20 Providing 15mm thick cement plaster in single coat on Rough 638.70 Sqm 180.39
(Similar)side of single or half brick walls for interior plastering upto
All floor level and finished even and smooth in (i) Cement mortar
1:3 (1-cement:3-sand)
21 20 mm thick sand faced cement plaster on walls upto height 10 298.00 Sqm 315.69
metres above ground level consisting of 12mm thick backing coat of
C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M.
1:1 (1-cement : 1-sand) etc. complete.
22 Providing 10 mmthick cement plaster in single coat on fair side of 144.80 Sqm 186.09
Brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (I)cement mortar 1:3 (1 cement:3 sand)
.Upto floor two level finished even & Smooth with floating coat of
neat cement slurry.
23 Providing 10 mm thick cement plaster in single coat on 70.00 Sqm 161.53
brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-
sand) for plastering on ceilings and sofits of stairs upto floor two
level instead of plastering on walls.
24 Providing and laying 24" x 24" vitrified 8mm thick tile flooring over 88.00 Sqm 1476.54
20MM (average) base of cement mortar 1:6 (1- Cement : 6-Coarse
Sand) on new surface or fixing on existing flooring by adhe-sive
material including dismentalling of existing flooring and jointed with
colour cement slurry including finished with flush pointing and
cleaning the surface etc. complete. For Light shade
25 Finishing wall with weather proof exterior emulsion paint on wall 298.00 Sqm 120.26
surface(two coats) to give an required shape even shade after
thoroughly brushing the surface to rempve all dirt, and remains of
loose powdered materials etc complete.
26 Wall painting (two coats) with plastic emulsion paint of approved 144.80 Sqm 124.96
brands and manufacture on undecorated wall surfaces to give an
even shade including thorougnly brushinf the surface free from
mortar droppings and other foreign matter and sand papered
smooth including Applying two coats of Birla or Asian acrylic lappy
(purty) and two coats of primer of approved brand and manufacture
on new wall surface to give an even shade.
27 Ceiling painting (two coats) with plastic emulsion paint of approved 102.00 Sqm 130.48
brands and manufacture on undecorated wall surfaces to give an
even shade including thorougnly brushinf the surface free from
mortar droppings and other foreign matter and sand papered
smooth including Applying two coats of Birla or Asian acrylic lappy
(purty) and two coats of primer of approved brand and manufacture
on new wall surface to give an even shade.
28 White washing with lime on wall surface (two coats) to give an even 638.70 Sqm 12.69
shade including thoroughly booming the surface to remove all dirt,
dust; mortar drops and other foreign matter.
29 Providing, laying and jointing in true line and level 110 diametre 16.00 Rm 876.90
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to ISI
14735-1999 of approved make for drainage system pipe line, pipe
shall be jointed with each other with rubber lubricant, pipe shall be
fixed on wall using of PVC clamp of the size 110 mm diametre x
mm length x 145 mm heigh at every 2000 mm center to center or
shall be concealed in walls as directed including necessary fittings
such as bends, shoes etc. including testing of pipes and joints and
jointed with adhesive solvent cement including cost of all materials.
30 Providing and laying broken china mosaic flooring for 90.00 Sqm 779.70
terrace using 12 mm to 20 mm broken pieces of glazed tiles to be
laid over cement mortar 1:3 to plain or slope and to be tempered
to bring mortar creme out upto surface using white cement
including rounding off junctions and extending them upto 15 cm
along the wall,clearing with water and oxalic acid etc. as directed.
31 Providing and fixing Window having extruded Alluminium Colour 14.40 Sqm 1713.70
anodized Section frame main outer size 63.50 x 38.10 x 1.95mm (of
Jindal Section No. 4605, @ Wt. 1.094 Kg./Rmt.) horizontal Two
Track member size 61.85mm x 31.75mm x 1.20mm (of Jindal
Section No. 8687 @ Wt. 0.695 Kg./mt.) vertical member of size
61.85mm x 31.75mm x 1.30mm (of Jindal Section No. 8758 @ Wt.
of 0.659 Kg./mt.) with Sliding Shttuer of Horizontal member size
40mm x 18mm x 1.29mm (of Jindal Section No. 8949 @ Wt. of
0.456 Kg./mt.) Vertical member of size 40mm x 18mm x 1.29mm (of
Jindal Section No. 8947 @ Wt. of 0.456 Kg./mt. / Section 8948 @
Wt. 0.457 Kg/mt.) with 5mm thick transparent bronze colour tinted
float glass with powder coated alluminium fittings and fixtures and
transparent silicon section glass fixing to frame as per details etc.
complete for window
32 Providing and fixing M.S. grills of required pattern to wooden frames 216.00 Kg 163.02
of windows etc. with M.S. flats at required spacings and frame
alround, square or round bars with round headed bolts and nuts or
by screws. (B) ORNAMENTAL GRILL
33 Providing and fixing 20cm. x 15cm x 2.5 cm. thick year plate of 1.00 No 306.14
marble stone set in C.M. 1:4 including finishing and engraving letters
34 Providing & Fixing Marble Takti of Size 60cm x45 cm. including 2.00 No 2020.00
carving & painting the letters related to scheme & year as directed
Dismentled Material Credit Rs. 0 will be deducted from 1 St R.A. Bill
Rupees Twenty Four Lakh Sixty Four Thousand Five Hundred Three and Paise Twenty only
I \ We am \ are willing to carry out the work at ……………………… % above\bellow percent ( Should be written in figures
and words ) of the estimated rate mentioned above. Amount of My \ Our tender works put as under.
* Estimated Amount * Estimated Amount
Put to tender Rs…………………… Put to tender Rs……………………
Deduct……..……..% Add……..……..%
In words………………….……………… In words………………….………………
1.The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for
which no extra payment shall be made.
2.The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3.GST and Income tax TDS will be deducted at a source while making payments of bills
4.In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017
Cement Consumption/16/C Date:11/05/2017 as stated in
S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost
of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in
all the tender.
Signature of Contractor
Deputy Executive Engineer Executive Engineer
Panchayat R.& B. Sub Division Panchayat R.& B. Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1 SBD Commu Hall and CW Wall (Thikariyala Kerala Chandrpur).pdf
2 Spe Index.pdf
3 Specification.pdf
4 Sch -B.pdf
5 Qty Sheet.pdf
6 Test Shedual.pdf
7 All Circular_compressed.pdf
8 DRG.pdf
9 DRG.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .