Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC 676301 | MALAPPURAM | KERALA | 676301 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.5 L+₹708 (0.28%)Accepted-AOC EDAYUR PO VALANCHERY MALAPPURAM | MALAPPURAM | KERALA | 676552 | L2 | Accepted-AOC L2 |
Tender Value
₹2.5 L
EMD Value
₹6,224
Closing Date
15 Sept 2023, 2:00 pmClosed
OFFICEOFASSISTANTENGINEERLIDEWKUTTIPPURAM
OFFICEOFASSISTANTENGINEERLIDEWKUTTIPPURAM
Annual PlanWSS 22623 Electrical Work in Kuttippuram Grama panchayatElectrical repairs to Athikkal WSSGeneral Electrical Work
2023_LSGD_600290_1
24/2023-24/AE/LID EW/KTPM
Open Tender
Civil Works - Water Works
Item Rate
120 days
OFFICEOFASSISTANTENGINEERLIDEWKUTTIPPURAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹6,224
Yes
5 Jun 2024
5 Sept 2023
16 Sept 2023
5 Sept 2023
15 Sept 2023
5 Sept 2023
Amount
Electrical repairs
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD79211/2023-2024:Supply and fixing phase indication lamp (led) blue on existing board and giving connection
OD79212/2023-2024:Supply and fixing phase indication lamp (led) red/yellow on existing board and giving connection
OD82261/2023-2024:Supply and fixing 63A TPN SDF with sheet steel enclosure and HRC fuses on existing board and giving connection as required
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD79217/2023-2024:Supply and fixing 3 phase ammeter accuracy class 1 on existing board and giving connection
OD79218/2023-2024:Supply and fixing 3 phase volt meter accuracy class 1 on existing board and giving connection
OD79263/2023-2024:Supply and fixing TPMCB sheet steel enclosure on surface and giving connection as required
OD79264/2023-2024:Supply and fixing 6/10 A DPMCB on existing board and giving connection as required
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD79808/2023-2024:Supply and fixing 63A 4pole ON LOAD Change over switch with sheet steel enclosure on existing board and giving connection as required
90.14.24.20:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
OD81495/2023-2024:Supply, conveyance, installation,testing and commissioning of fully automatic star delta stater suitable for upto 25HP motor on existing board including giving connections.
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD81833/2023-2024:Supply and providing superior quality brassbolt with hexagonnal/square head,nut and washers for the following size etc as required 12*3mm.
OD81834/2023-2024:Supply and providing superior quality brass bolt with hexagonal/square head ,nut and washers for the following size etc as required 25*6 mm
OD81835/2023-2024:Supply and fixing 2*25*5 mmGI strip test joint for earthing
OD81836/2023-2024:Supply and fixing25mm*3mm GI Strip earth lead from test joint to earth plate
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD81854/2023-2024:Supply installation testing and commissioning of vertical open well submersible motorpumpset , 15 HP 3 phase 380/400 V ,50 Hz,,2800rpm,56-128mts,600-180lpm with 63mm outlet 6 stage TEXMO EAVM 70/06 or equivalent make of CRI/TEXMO/KIRLOSKER/V GUARD in the open well using chain pully block/tripole,scaffolding etc giving connection to delivery pipe using leack proof materials tied and suspended on suppot with nylon rope and clamps including giving electric connections and conducting trial run at full load satisfactorily
OD82311/2023-2024:Supply and laying good quality 75mm HD pipe(ISI marked) with specials and giving connection using lrack proof materials as required
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
OD82765/2023-2024:Dismantling the existing electric connections of 15HP open well submersible motor pump set, Detaching the delivery pipe connections to pump set, Lifting the Motor pump set to the top of the well using chain pully block/tri-pole etc.
OD82764/2023-2024:Lifting, leading the 15HP motor pump set and transporting the same to nearest workshop through special conveyance and unloading there.
OD82763/2023-2024:Decoupling the 15HP motor pump set, separating the motor in to stator and rotor, Pump into impeller, shaft, bearing/sleeve etc.
OD83902/2023-2024:Supply of new cast iron impellar set of 15 hp pumpset
OD83911/2023-2024:Charges for assembling the motor pumpset in full shape using reconditioned/repaired parts painting with enamel paint and conducting trial at full load
OD83924/2023-2024:Lifting,leading, and loading the reconditioned motor pump set from work shop to vehicle and transporting back to pump house
OD83976/2023-2024:Errection charges for reconditioned motor pumpset into openwell by lowering to bottom of well using chain pully block/tripole,scaffolding etc giving connection to the delivery pipe of GI , tied to the existing rope,giving all eletrical connections and conducting trial at full load satisfactorily
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD84165/2023-2024:Supply and installation of 9w LED Bulb 240V AC
90.17.14.4:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia
OD84446/2023-2024:Supply and providing HD Collar 75mm
OD84484/2023-2024:Supply and providing 75mm GI Tee as required
OD84496/2023-2024:Supply and providing Hose Collar 75mm
OD84548/2023-2024:Supply and replacing the wornout GM bush for impellar with new one inciuding all industrial works and labour charges as required.
OD84799/2023-2024:Supply and fixing dust and vermin proof 3phase syntex meter board GSMB 6535 as required
OD84800/2023-2024:Supply and providing63 A HRC fuse link with base and giving connection in the existing meter board
OD84802/2023-2024:Supply and providing 63A neutral link mounted on DMC/SMC base and giving connection in the existing meter board
OD94299/2023-2024:Dismandling ,Lifting leading loading the unserviceable/scrap / materials transporting the same to kuttippuram panchayat office unloading there and handover to concerned authority
OD95133/2023-2024:Charges for preparation of KSEB Test report for submitting to the concerned KSEB Section office
MOIDEENKUTTY KOLAMBAN
Bidder Name
AK ELECTRICALS
MOIDEENKUTTY KOLAMBAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_891581.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .