Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 LAccepted-Finance | L1 | Accepted-Finance l1 | |
| 2 | Rejected-Technical KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | Mahesh KR L1 | Power Care Electrical L2 |
|---|---|---|---|---|---|
| 1.00VAKERIKKUNNU PARAMBIL DWS | |||||
| 1.00 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 4 | metre | 170 ₹680 Lowest | 200 ₹800 |
| 1.00 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 3 | metre | 20 ₹60 Lowest | 50 ₹150 |
| 1.00 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | 122 | metre | 150 ₹18,300 Lowest | 200 ₹24,400 |
| 1.00 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 1 | each | 275 ₹275 Lowest | 300 ₹300 |
| 1.00 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 amps | 1 | each | 3,000 ₹3,000 Lowest | 3,200 ₹3,200 |
| 1.01 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | 1 | each | 1,000 ₹1,000 Lowest | 1,200 ₹1,200 |
| 1.01 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | 1 | set | 10,000 ₹10,000 Lowest | 11,000 ₹11,000 |
| 1.01 | 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 10 | metre | 260 ₹2,600 | 250 ₹2,500 Lowest |
| 1.01 | OD349621/2025-2026:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system | 1 | each | 405 ₹405 | 25 ₹25 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,373
Closing Date
16 Feb 2026, 3:30 pmClosed
ASSISTANT ENGINEER
ASSISTANT ENGINEER PANAMARAM BP 670721
PROVISION OF TANK AAND ELECTRIC MOTOR FACILITIES DOR DWSS PROJECCTSVARIOUS DIVISIONS 210
2025_LSGD_813096_6
AE/LSGD/PNM/BLK/06/2025-26 TENDER (4))
Open Tender
Electrical Works
Item Rate
PANAMARAM BP
Please refer Tender documents.
7 documents required · 7 mandatory
₹920
₹10,373
Yes
15 Jul 2026
7 Feb 2026
17 Feb 2026
7 Feb 2026
16 Feb 2026
7 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1VAKERIKKUNNU PARAMBIL DWS | |||||
| 1.001 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | - | metre | - | - |
| 1.002 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | - | metre | - | - |
| 1.003 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | - | metre | - | - |
| 1.004 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | - | each | - | - |
| 1.005 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 amps | - | each | - | - |
| 1.006 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | - | each | - | - |
| 1.007 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | - | set | - | - |
| 1.008 | 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | - | metre | - | - |
| 1.009 | OD349621/2025-2026:Providing and fixing 2 X 25 mm X 3 mm GI strip test joint for earthing system | - | each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
viewnit.pdf
Tender Documents • 0.03 MB
viewsbd.pdf
Tender Documents • 1.64 MB
BOQ_1403614.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .