Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | ₹36.9 L Quoted ₹38.4 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED |
| 2 | L2₹40.2 L+₹1.8 L (4.76%)Rejected-AOC | ₹40.2 L+₹1.8 L (4.76%) | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 3 | L3₹41.7 L+₹3.3 L (8.60%)Rejected-AOC | ₹41.7 L+₹3.3 L (8.60%) | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
| 4 | L4₹42.7 L+₹4.4 L (11.4%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹42.7 L+₹4.4 L (11.4%) | L4 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
17 Sept 2024, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE ARMY GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAR TO ROOF AND FALSE CEILING IN BUILDING NO NP 17 ORs LINE EXHAUST CEILING FANS AGAINST BER PROVN OF 02 X ACs AND RP GATE NO 2 AT MIL STN DHRANGADHRA
2024_MES_667572_1
GE(A)/GNR/TOKEN/49 of 2024-25
Open Tender
Civil Works
Item Rate
180 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY GANDHINAGAR
₹83,000
Yes
1 Jan 2025
23 Jul 2024
24 Sept 2024
23 Jul 2024
17 Sept 2024
6 Aug 2024
23 Jul 2024 - 4 Aug 2024
Amount
Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) n.exc 1.5 Sqm each complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonry, built in CM including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for walling of random rubble, uncoursed well bounded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed.
M & L for walling (Except stone) of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc 20mm for sand stone and dressing to face stones and dressing of face beds and joints as specified ,of random rubble walling ,uncoursed or brought upto courses completed as specified and directed .
Dismantling floor ,hearth or wall tiling incl cement mortar bedding (but not backing) complete all as specified and as directed .
Dismantling wrought iron or mild steel work of any description not otherwise proviceded for
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing complete all as specified and directed.
M & L, non skid White ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 Sqm, over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed
M & L, non skid White ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, in floors over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed
M & L, glazed coloured ceramic tiles in vertical surface as in skirting & dado, 7 to 8 mm thick area exc 0.05 Sqm but n.exc 0.18 Sqm over and including 10 mm thick rendering in CM1:4 set & jointed in neat cement slurry & pointed in coloured cement to match complete all as specified and directed.
M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:4 complete all as specified and directed.
M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 and finishing even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces and applying two coat of oil bound distemper over and including a layer of wall care putty to achive a smooth finish surface (average thickness 1 mm) complete all as specified and directed.
Preparation of old plastered surfaces by complete removal of existing treatment and applying two coat of oil bound distemper over and including a layer of wall care putty (average thickness 1 mm) complete all as specified and directed.
Preparing of plastered or unplastered old decorated surfaces of walls by complete removal of existing treatment, moulds, moss and efflorescent salt and treating oil and greasy spots and applying three coat of white wash on walls including cornices etc complete all as specified and directed
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coats of cement base paint complete all as specified and directed.
S&F in repair 18/19 mm thick prelaminated particle board interior grade ,prelaminated one side with decorative choice laminations and other side balancing white lamination fixed with screws to timber frame work in cup boards ,rebated or flat ege complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast ,filling etc complete all as specified and directed.
S&F in repair Stainless steel Door hinges medium weight, cold rolled 100 mm size all as specified and directed.
M&L, preparing of Old wooden surface exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F standard aluminium section powder coated any colour as approved for door frames / three track shutters, window, ventilator frames/three track shutters sliding/fixed /louvered and partitions etc including jointing cleat and rubber beading/linning, Pivot ,locking aragement and fixed in position with stainless steel screws all as specified and as directed.
Supply and Fixing sheet glass 4.8 mm thick ordinary quality and glazing with oil putty or rubber and aluminium beading in squares n. exc 0.5 sqm in each pane complete all as specified and directed.
Supply and Fixing in repair ot 3mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56 mm nomonal dia of bar and 1.18 mm avrage width of aperture ,fixed with tined tacks or galvanised wire staples complete all as specified and as directed.
M&L, preparing of new steel surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F in aluminium, anodised barrel tower bolts 150mm long of extruded section and fixed complete all as specified and directed.
S&F, aluminium handles 150mm size, cast type, anodised complete all as specified and directed.
Dismantling Asbestos cement (Corrugated semicorrugated ,etc) sheets in roof coverings
M & L, Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in single length complete all as specified and directed.
M & L Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L for , false ceiling consisting of wall angles ,main T ,cross T all of size 25 mm X25mmX1.4mm thick power coated GI grid frame work jointed angle as directed and mild steel hooks not less than 4 mm dia with arrangement for adjusting heights of ceiling with and incl provision of 4 mm thick E boards sheet in panels of size 600mmX600mm with necessary off cuts and fixing arrangements for ceiling ,tube light fitting incl dismantling of existing false ceiling complete all as specified and as directed.
Dismantling timber scantling 40 sqcm and over in section ,an any position (framed)
Taking down of roof trusses, above 4 mtr & up to 8 mtr coupled rafters or trussed beams
S&F rolled mild steel section as in main and cross beams hip and jack rafters , purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed.
S&F for mild steel for roof truses (framed) ,trussed purlins crane gantires ,rails and fasternings and heavy bracket framming (beam tee angle channel or flat sections )including distance pieces , clats etc and confir to Fe-410-w (GdeE-250) quality A including one shop coat of zinc chrome primer complete all as specified and directed.
S&F MS angle iron framed work as in doors or gate of angle or other section conforming to Fe 290 (Gde E-165) with gusset plates rails braces etc complete including hangin galso fastenin gand fxing complete as specified and directed .
S&F in repairs bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe.
S&F in repairs Stop valves /Angle cock/ concealed stop valves cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe.
S&F in repair 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed.
S&F in repair vitreous china squatting pan, orrisa pattern, size 580mm x 440mm white, with integral foot rests (excluding flushing cistern & flush pipe) including making good to disturbed floor with PCC complete all as specified and directed.
S&F in repairs PVC low level 10 lit capacity valveless syphonic action type flushing cistern including 32mm dia PVC flush pipe fixed in repairs complete all as specified and directed
S&F Brass chromium plated Tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete.
Dismantling of water tank & n exc 1000 ltr capacity in litres and removing to store
Supply & Fix 1000 litre capacity three layered rotational moulded polythylene water storage tanks (cylindrical vertical with closed top ) hoisted and fixed in position complete all as specified and directed.
Refixing old serviceable 15 mm GI tubing and connection in new or old position (concealed in Wall, ceiling & floor etc.) including necessary fittings & fixtures etc. complete all as specified and directed
S&F 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors incl cutting chases where required complete complete all as specified and directed
Refixing old serviceable 20 mm GI tubing and connection in new or old position (concealed in Wall, ceiling floor etc.) including necessary fittings & fixtures etc. complete all as specified and directed
S&F 20 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors incl cutting chases where required complete complete all as specified and directed
S&F in repair 20mm Gate valves with iron wheel head screwed both ends for iron pipe and fixed.
S&F in repair white glazed earthen ware vitreous china wash hand basin of size 550x400 mm with and including CI brackets ,32mm bore bras CP waste coupling lintel /out let PVC flexible pipe 600mm size for 15mm with brass nut and washers etc complete.
Supply & Fix in repair 15 mm dia pillar tap (long nose)cast copper alloy with capstan head chromium plated fancy type, screwed down high pressure, with or without lettered "Hot or Cold" with long swan neck swivel type screwed for iron pipe and fixed complete all as specified and directed.
S & F Soap dish chromium plated approximate size 160x 160x90mm complete all as specified and directed.
S&F 5.5mm thick glass shelf of size 600mm long fancy type fixed and including Chromium plated grils, screws and wooden /plastic cleats complete all as specified and directed
S&F 5.5mm thick glass corner shelf assembly fancy type size 250mmx250mmfixed with and including chromium plates brass screws and wooden /plastic cleats complete all as specified and directed
S & F Aluminium Hat pegs of 6 pegs,solid body 125mm to 175 mm complete.
S & F Brass chromium plated shower rose 125mm size incl shower arm complete all as specified and directed.
S & F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Supply & Fix in repairs, 75mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and fixed to wall with PVC holding clamps complete all as specified and directed.
S&F in repairs, 110mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repairs, 125/110mm bore PVC (SWR) 'P’ trap complete all as specified and directed.
S&F in repairs, 75mm bore dia PVC floor trap (SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed.
S&F in repairs, 110mm bore PVC(SWR) bends any radius, complete all as specified and directed.
S &F PVC (SWR) 75 mm dia vent cowl
M&L for 20 mm thick Granite (of any type of coloured) tiles maxhine cut in skirting/dado laid over cement screed and jointed with grey cement slurry ,and pointed with grey cement slurry ,and pointed with white cement with adimixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick screed bed in CM 1:6 incl moulding, chamfering of edges complete.
M&L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded Stone aggregate) as in plinth protection finisheed even and smooth without using extra cement complete.
Demolition of precast concrete articles and pre-cast cement concrete block walling, ashlar fencings, dressed stone work including all quoins, arches, pillars etc. built in cement mortar complete all as specified and directed.
M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed .
All as per item No. 72 above but in except block
M&L, providing cement concrete1:2:4 type B1 as in , coping ,benching, bressumers, steps, incl necessary form work and demolition of existing cement work complete all as specified and as directed.
Demolition of plain cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
S&F Harrison rails, mild steel chromium plated with fixing brackets ,stops ,rolleres etc complete all as specified and as directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and directed.
M&L for RCC (Nominal Mix) type B0 1:2:4 12.5mm graded aggregate ) as in Beams, cantilevers ,bressummers lintels over 1.5 m span on walls,beams and columns etc complete all as specified and as directed.
Form work to side and soffits of floor or roof beams , beam haunching s , girders bressummers lintels , cantilevers , shelves including sup - ports ,overhangs etc also splays between floors ans beams etc .
M&L for MS TMT bars10mm dia and over cut to Length bent to shape required including cranking, bending, spirally for hooping for columns with an incl MS wire(Annealed not less than .90 mm Dia) or securing with clips complete all as specified and directed.
Supply & fix purpose made crew bolts with hexogonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexogonal or square nut 16-20 mm dia and exc. 22cm and nexc. 30 cm long complete all as specified and as directed.
S&F Steel windows with side hung shutters including Box type hinges with steel handle, and steel tower bolt complete with glazing bars, dovetailed or welded including taking down old windows complete all as specified and directed.
S&F Steel windows with side hung shutters including Box type hinges with steel handle, and steel tower bolt, complete with out glazing bars, dovetailed or welded complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L, preparation old previously treated steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint on the steel surfaces, complete all as specified and directed.
S&F M.S Framed work such as grills gratings etc with ends of bars sholdered and/or riveted into spikes ,framed guard bars /railings all as directed .
Excavation in trenches any type of soil not exc 1.5m wide and not exc 1.5 m in depth and getting out in soil/disintegrated soil
M & L Returning filling in incl spreading incl leveling, watering and welll ramming in layers n,exc 25cm layers
Removing excavation mtrl n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point in rock
PCC (1:4:8) type D 2 using 40mm graded aggement as in fdn filling land mass concrete
M/L Brick work with sub class 'B' bricks straight or curved on plan exc 6 M mean radius in CM 1:6
RCC (Nominal Mix) type B 0 1:2:4 (12.5 mm graded aggregate) as in columns, pillars, piers, posts and struts etc
M & L for mild steel TMT bars 10mm dia and over , cut to length ,bend to shape required, uncluding cranding ,bending sporally for hooping spirally for hooping for columns, hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or ssecuring with clips .
All as per item No. 93 above but 8mm dia stirrups.
Form work to side of concrete foundations, footings, base of columsns, raft and beams, side and soffits (if any) of foundations and plinth beam and similar work
Form work to sides of pillars, posts, etruts, piers columns and stanchions.
Framed work as in door or gates of angle or other section with gusset plate, rails, braces etc, complete, drilled for fixing of steel sheetings or other covering. Door etc, to to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitings (exclusive of steel sheeting or other covering, running rail or girders)and hanging, also fastening and fixing in Fe 410-W Gde E-250) quality -A complete.
M/L 15 mm thick rendering in CM 1:4 on Fair face of brick masonary/concrete surfaces incl finishing even and smooth w/o using extra cement
M/L 5mm thk rendering in CM 1:4 on fair faces of brick masonry/concrete surfaces incl finishing even and smooth w/o using extra cement.
M&L for 2 coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth over a coat of red oxide incl preparation of surfaces.
Applying two coats of cement base paint over a coat of white wash on new plastered surfaces of wall including preparation of surfeces
Taking down carefully copper/aluminium point wiring (Light, fan, socket or power etc.) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etc all as specified and directed by Engr-in-charge.
M&L for point wiring for one light/fan/bell point controlled by one switch one way in & including PVC casing and capping using FRLS PVC sheathed multistrand copper conductor wire 1.5 sqmm single core for one light/fan point controlled by one switch including modular white cover plate with frame of suitable modules over modular metal flush box concealed type for earth continuity insulated PVC sheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge. Note : (a) wiring shall be done by using proper colour coding.
All as per srl item No. 103 here-in-before but for 05 Amp socket outlet on independent board complete all as specified.
All as per srl item No. 103 here-in-before but for 05 Amp socket outlet on same board complete all as specified.
All as per srl item No. 103 here-in-before but for 15 Amp independent socket outlet using 2.5 sqmm single core wire (for phase, nuetral and earth) complete all as specified.
S&F switch piano, flush type 5 Amps one way 230 volts complete all as specified.
S&F socket outlet 3 pin 6 Amps flush type 230 volts complete all as specified.
S&F socket outlet 2-in-1 3 pin 6 & 16 Amps flush type 230 volts complete all as specified.
S&F switch one way 15 Amp flush type 230 volts complete all as specified.
S&F ceiling rose 3 terminal size 50x65mm surface type 230 volts complete all as specified.
S&F led COMPACT fitting for LED tube double side connection of 1x20W, 220V, AC decorative box type 4ft with integral LED driver including 18W, T8 tube rod complete all as directed by Engr-In-charge.
S&F DB with metal plug and socket double pole with MCB SP of 20 Amps, 230 V, 10 KA all as specified and as directed by Engineer-in-charge.
S&F Distribution Board VTPN, 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including 3 pole MCCB 63 Amps rating, 16KA breaking capacity for incoming supply and provision of MCB SP/TP for out going supply complete
S&F Sheet metal enclosure double door for DB's SPN 12 way 240 V having 200 A rated bus bar complete all as specified and directed by Engr-in-charge.
S&F MCB SPN 32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge.
S&F MCB SP 6-32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge.
Taking down carefully old unsv submain wiring of any type/any size with PVC conduit or casing caping complete all as specified and directed.
M&L in replacement for Sub main wiring complete with FRLS PVC insulated sheathed stranded copper conductor wire 4.0 Sq mm 02 runs (for Phase & Neutal) along with earth wire FRLS PVC insulated sheathed stranded copper conductor wire of size 4.0 sq mm wire drawn through in & including PVC casing caping complete all as specified and directed by Engineer-in-Charge.
S&F fan regulator stepped type, electronic, flush type on the existing phenolic laminated sheet etc. complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fans 1200mm sweep energy effcient five star rated 230 volts with brushless direct current motor (BLDC) with blades, down rods, electronic regulator control type and accessories and connecting up with ceiling rose to fan complete all as specified and directed by Engineer-in-Charge.
Taking down carefully old unserviceable main switches/ Distribution board any type including fuses MCB etc after removing all connection and making good the disturb surface all as directed by Engineer-in-charge.
Supply and fix of exhaust fan 300 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with blades, and frame and louvers including connetion with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e. anchor nut, bolt, washer, grounting and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Labour only for cutting/opening in stone masonry wall suitable for exhaust fan of 300mm dia and makng good the disturbed surface complete all as specified and directed by Engineer-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, 230Volts, single phase, 50 Hz AC, energy saving high density PUF insulation complete with all accessories such as safety valve, thermostate, NRV, inlet and outlet (cold & hot) PVC pipes utpo 450mm long with 15A plug top etc. complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth Lead 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth wire of 4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 15mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 20 mm bore light grade 7.5m
S&F 30W New generation energy saving and environmental friendly long life LED building security light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 for bldg security light with GI pipe bracket of suitable size for fitting complete all as specified and directed by Engineer-in-Charge.
Disconnecting carefully and taking down the existing ceiling fan of any size, and depositing to MES E/M store for safe custody complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of 1.5 ton high wall split Air Conditioner of nominal cooling capacity, 5 star, duel iverter, Eco-friendly Refrigerator, suitable connecting electrical cable with top for installation, commissionning with outdoor unit stand complete all as specified and directed.
S&F Voltage stabilizer for automatic operation single phase naturally air-cooled type & designed for input between 170v to 250 V with output voltage stabilized at 230V accuracy of + 2.5 and capacity 4 KVA including complete testing all as specified and directed by Engineer-in-Charge.
M&L for sub main wiring complete with FRLS PVC insulated unsheathed copper conductor wire 4.0 Sqmm 02 runs (for Phase & Neutral along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 4.0 Sqmm wire drawn through in & includng PVC casing & capping or conduit as per site requirement complete all as specified and directed by Engineer-in-Charge. Note : 02 Run of cable of 01 Run of conduit shall be mearued as one unit.
S&F metal plug and socket double pole with MCB SP of 20 Amps, 230 V, 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply and fix of exhaust fan 230 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with blades, and frame and louvers including connetion with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e. anchor nut, bolt, washer, grounting and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix of exhaust fan 380 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with blades, and frame and louvers including connetion with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e. anchor nut, bolt, washer, grounting and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix of exhaust fan 450 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with blades, and frame and louvers including connetion with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e. anchor nut, bolt, washer, grounting and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fans 1200mm sweep energy effcient five star rated 230 volts with brushless direct current motor (BLDC) with blades, down rods, electronic regulator control type and accessories and connecting up with ceiling rose to fan complete all as specified and directed by Engineer-in-Charge.
Singh Engineer And Contractor (BID ID -3092078)
AMI CONSTRUCTIONS (BID ID -3092336)
ALBA AC AND REF SERVICES (BID ID -3089985)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .