| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC L1 bidder. | |
| 2 | L2₹8.2 L+₹37,100 (4.73%)Rejected-AOC NO 03 1ST FLOOR KMV COMPLEX KODGEHALLI TINDLU MAIN ROAD NEAR RAILWAY UNDER PASS KODGEHALLI SAHAKARNAGAR BANGALORE | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.6 L+₹80,000 (10.2%)Rejected-AOC 14 15 A CHANDU MASTER ROAD VISHNUPURAM CHERANALLOOR ERNAKULAM KERALA 682034 | ERNAKULAM | KERALA | 682034 | L3 | Rejected-AOC L3 |
Tender Value
₹9.1 L
EMD Value
₹13,714
Closing Date
6 Sept 2021, 12:00 pmClosed
Chief Executive Officer
Chief Executive Officer, Park Center, Technopark
Rectification and Relocation of Fire Alarm Panel at Technopark Kollam Campus IT Building SEZ, Kundara, Kollam
2021_ETPK_435329_1
ETPK/PH-V/21-22/AT-126
Open Tender
Miscellaneous Works
Item Rate
80 days
Kundara
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,828
₹13,714
5 Jan 2022
16 Aug 2021
7 Sept 2021
17 Aug 2021
6 Sept 2021
18 Aug 2021
Amount
Loop rectification ( Replacement of faulty Loop Card), Panel Rectification, Programming, testing & commissioning of All Loop Micro processor based 2 wire fault tolerant loop, required loop networkable type (each loop accessing 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. Panel will have 6x40 characters, blue LCD with backlight illumination.The Panel Shall have ingress protection IP30. The Panel Shall have 80 Zone scan be used with or without zone LED's. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger 2 x 12 volt /17 AH, conforming to BS5839 Standards and Duly Approved by LPCB including all accessories as required for complete installation. Make : SECUTRON
Supply, installation, testing & commissioning of Intelligent Analog Addressable Type low profile Photoelectric Type smoke detector.Hard Addressable Having rotary decade Address swicthes from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA(below false ceiling) including all accessores as required for complete installation. Make : SECUTRON
Supply, installation, testing & commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54/LPCB/VDS/UL/BSA having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved including all accessories required for complete installation Make : SECUTRON
Supply, installation, testing & commissioning Of Addressable Type Loop Powered sounder complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA including all accessories required for complete installation Make : SECUTRON
Supply,Installation,Testing & Commissioning of Analogue Addressable Fault input module including all accessories required for complete installation. Make : SECUTRON
Supply,Installation,Testing & Commissioning of Analogue Thermal/Heat sensor 135 Degree F Make : SECUTRON
Supply, laying, testing and commisioning and making terminations for 2 Core x 1.5 Sq.mm cable, Armoured Screened FRLS Twin Twisted PVC Insulated copper cable along with all accessories required for complete installation, making terminations etc where required Make : Polycab/Havels
Relocation of Fire Panel to a more suitable location (within a radius 20 meters) as per the directions of engineer in charge.
Supply and installation of 3X3 Metal box installation
Relocation of Old smoke detector (within 5-10 meters) as per the directions of engineer in charge.
Supply installation testing and commissioning of Isolator module with supply voltage of 17 VDC to 28 VDC and Maxumum Current through loop : 1A , 3A peek, Isolating voltage of : <14 VDC MAKE : RAVEL / MORLEY
SLN AUTOMATION INDIA PRIVATE LIMITED
COCHIN FIRE TECH INDIA PVT. LTD.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_618568.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .