Loading…
Loading…
Tender Value
₹24.1 Cr
EMD Value
₹48.2 L
Closing Date
12 May 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
TENDER
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual Contractual Turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
8 conditions · 4 needing a document upload
1. Earnest money deposit (scanned copy of the instrument to be attached) 2. Experience certificate (scanned copy of the credentials to be attached) 3. Turn over details (scanned copy of the attested certificates from the employer/ client, audited balance sheet duly certified by the chartered accountant etc., to be attached) 4. Details of strength of staff employed
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
All works tenders or service tenders invited by railways through e-tendering on IREPS, having advertised value of Rs 10 lakh and above, contractors are eligible to take payment from Railways through a Letter of credit (LC) arrangement. (Ref: RB letter no.2018/CE-I/CT/9 dated 04.06.18) (i) For all the tenders having advertised cost of Rs 10 lakh or above, the contractor shall have the option to take payment from Railways through a letter of credit (LC) arrangement. (ii) T h i s option of taking payment through L C arrangement h a s t o be exercised in !REPS (Indian Railway Electronic Procurement System - the e-application on which tenders are called by Railways) by the tenderer at the time of bidding itself, and the tenderer shall affirm having read over and agreed to the terms and conditions of the LC option.(iii) The option so exercised, shall be an integral part of the bidder's offer. (iv) T h e above option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract. (v) In case tenderer opts for payment through LC, necessary procedure for LC mode of payment shall be followed to deal release of payment through LC:
Provision of Indoor and Outdoor signalling and Telecommunication arrangements at Neyyatinkara station for stage-I & Stage-II works in connection with doubling of track between Thiruvananthapuram Central and Kanniyakumari Station
ERS-SG-CN-02-2026
ERS-SG-CN-02-2026
Open
Works - General
12 Months
Ernakulam, Kerala
₹0
₹48.2 L
12 May 2026
17 Apr 2026
28 Apr 2026
339 items across 7 schedules · ₹18,93,35,776.54 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply o f Electronic Interlocking (Hot Standby) f o r stations w i t h Signalling functions u p t o 1 2 5 u n i t s a s per Function table enclosed along with 15% spares, tools, manuals and Instruments. Centralised E.I to be provided a s p e r R D S O S p e c . No. RDSO/SPN/192/2019/Ver 2.0 o r latest. (Functions include a l l v i t a l a n d non vital inputs a n d outputs t o E I except read back inputs) | Set | 1.00 | 1,14,34,483.51 | 1,14,34,483.51 |
| 2 | Incremental rate for signalling functions in EI SYSTEM over and above 125 functions under item No 1 (Per Unit=Per Function) | Per Unit | 275.00 | 1,04,018.64 | 2,86,05,126 |
| 3 | Supply of fan less embedded industrial grade computers (Similar to Moxa V2406 or better) with a l l accessories suc h a s k e y board, mouse, antivirus e t c . o f i n d u s t r i a l g r a d e as per approved Specification as recommended by latest RDSO Specification(RDSO/SPN/192 or 203 or latest) for EI | Numbers | 3.00 | 3,75,562.03 | 11,26,686.09 |
| 4 | Supply o f Power Supply arrangement for VDU and Embedded PC. This includes supply of 2 N o s of 110VDC/24DC, 1 0 A DC-DC converter a n d 2 N o s o f 1 1 0 V D C / 1 1 0 V AC, 500VAInverter in (1+1) configuration. (as per Technical Specification enclosed) | Set | 3.00 | 2,14,096.98 | 6,42,290.94 |
| 5 | Supply of Double Key Lock | Numbers | 1.00 | 481.77 | 481.77 |
| 6 | Supply and Installation of work space as per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement) | Numbers | 1.00 | 9,48,672.1 | 9,48,672.1 |
| 7 | Installation, Wiring, testing, Soldering o f all EI equipments, earthing o f EI Equipment, Relay R a c k s a n d Power Equipment etc. including s u p p l y of power cable and Documents/Manuals etc. (Per Unit= Per EI Hut) | Per Unit | 1.00 | 9,25,301.63 | 9,25,301.63 |
| 8 | D e s i g n a n d d r a w i n g f o r complete indoor signalling work for new PI/RRI/EI (Per unit = Per PI/RRI/EI) | Per Unit | 2.00 | 3,55,737.9 | 7,11,475.8 |
| 9 | C o m m i s s i o n i n g o f Electronic Interlocking system (Per Unit = Per EI) | Per Unit | 2.00 | 31,901.72 | 63,803.44 |
| 10 | "Training of Railway Personnel in installation, commissioning, testing, troubleshooting and in diagnosing f a u l t s u s i n g diagnostic tools/flow charts including supply of necessary documents. (Per Unit= 60 Man Days)" | Per Unit | 1.00 | 72,995.54 | 72,995.54 |
| 11 | " C a r r y i n g o u t A u t o m a t i c Factory Acceptance test for any station having Centralized EI configuration" | Station | 2.00 | 1,56,701.19 | 3,13,402.38 |
| 12 | "Carrying out Automatic Site Acceptance test for any station having Centralized EI configuration." | Station | 2.00 | 6,31,595 | 12,63,190 |
| 13 | P r e p a r a t i o n o f c i r c u i t s , location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared i n A 3 / A 2 / U s i z e as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. a) Preparation of soft copy in AUTO CADD from A3 size hard copy | Sheet | 300.00 | 218.3 | 65,490 |
| 14 | P r e p a r a t i o n o f c i r c u i t s , location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared i n A 3 / A 2 / U s i z e as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.c)Preparation of soft copy in AUTO CADD from U size hard copy | Sheet | 4.00 | 1,548.45 | 6,193.8 |
| 15 | "Supply, of Datalogger with 512 Digital Input and 32 Analog Input as per RDSO specification No. IRS:S-99/2006 Amdt 3 (or) latest w i t h p o w e r supply arrangements. (This work does not includes wiring of inputs from Relay to Intermediate tag block & from intermediate t a g block t o Datalogger equipment)" | Numbers | 1.00 | 4,46,627.2 | 4,46,627.2 |
| 16 | "Supply o f Fault Analysis Terminal for analysis of fault and generating reports for Datalogger installed at stations. As per Technical Specifications." | Numbers | 1.00 | 54,723.27 | 54,723.27 |
| 17 | Supply o f Protocol Converter suitable for Electronic Interlocking system equipment | Numbers | 1.00 | 68,051.41 | 68,051.41 |
| 18 | Supply of External 4wire leased line modem for enabling RT U connectivity with Dataloggers at Stations | Numbers | 2.00 | 39,622.8 | 79,245.6 |
| 19 | S u p p l y o f i s o l a t i o n transformer 600:470 ohms a s per IRS T C 76-2001 amd 1 or latest | Numbers | 2.00 | 791.12 | 1,582.24 |
| 20 | "Installation o f Datalogger o f Capacity 512 Digital a n d 3 2 A n a l o g . This includes transportation of materials to Site location and provision o f Ladder a n d c a b l e trough arrangements including connection to the BRC earth. Also includes carrying out of pre- commission checklist a n d Networking of datalogger. (This schedule doesn't c o v e r w i r i n g and preparation of simulation chart)" | Numbers | 1.00 | 29,500 | 29,500 |
| 21 | "Preparation o f Simulation Database which includes chart preparation for o n - l i n e and off-line simulation for display i n V D U for station o r Auto section. (Per Unit = Per Datalogger)" | Per Unit | 2.00 | 59,000 | 1,18,000 |
| 22 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 512.00 | 285.86 | 1,46,360.32 |
| 23 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wagos required is included as per schedule | Numbers | 20.00 | 285.86 | 5,717.2 |
| 24 | Installation o f Fault Analysis Terminal (for analysis o f fault a n d generating reports for Datalogger installed at stations) | Numbers | 1.00 | 23,452.83 | 23,452.83 |
| 25 | Installation of isolation transformer 600:470 ohms as per IRS TC 76-2001 or latest | Numbers | 2.00 | 339.05 | 678.1 |
| 26 | Supply of indicative type Surge Protection Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed) | Numbers | 1.00 | 22,756.39 | 22,756.39 |
| 27 | Supply and Provision of Earthing as per R D S O Specification RDSO/SPN/197/2008 or latest ( a s per Technical Specification enclosed) | Numbers | 10.00 | 28,118.51 | 2,81,185.1 |
| 28 | " S u p p l y a n d provision o f Earthing arrangements for EI/MSDAC buildings as per RDSO specifications as required for the EI system along with supply of all required materials. Earthing shall be carried out as per RDSO/SPN/197/2008 and RDSO Lr .No STS/L/SSI/CA/US&S Dt 2 6 . 0 7 . 2 0 1 1 forTypical Earthing connections for EI. Painting of earthing diagram as replica of the ground on backside wall of relay room as per the instruction of Site In-charge.(Per unit= Per goomty/station)" | Per Unit | 1.00 | 2,91,723.2 | 2,91,723.2 |
| 29 | Supply o f earth electrodes (GI) a s per Drg no SG/CN/02/13 | Numbers | 60.00 | 1,618.75 | 97,125 |
| 30 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 60.00 | 1,707.55 | 1,02,453 |
| 31 | "Full Location: Supply and fixing of GI Flat of size 1050x25x3mm as given in enclosed drawing t o connect all cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts o f size 8x25mm w ith Two flat and one spring washer of 23set. B) GI nuts/bolts o f s i z e 12x40mm with t w o flat and one spring washer of 02set as per site incharge" | Location Box | 75.00 | 1,370.66 | 1,02,799.5 |
| 32 | "Half Location: Supply and fixing of GI Flat of size 550x25x3mm a s given in enclosed drawing t o connect all cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts o f size 8x25mm w ith Two flat and one spring washer of 23set. B) GI nuts/bolts o f s i z e 12x40mm with t w o flat and one spring washer of 02set as per site incharge" | Location Box | 15.00 | 846.75 | 12,701.25 |
| 33 | "Installation of 230V Class B & Class C Surge Protection Device. This includes transportation o f materials t o site. Installation to be carried out as per the direction o f R a i l w a y Engineer. Necessary copper wire for Power Wiring and connecting the earth t o be supplied a s part o f the schedule. All other miscellaneous materials required for installation shall be supplied by the contractor." | Numbers | 1.00 | 9,752.74 | 9,752.74 |
| 34 | Supply o f 16-Channel Earth Leakage Detector a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest | Numbers | 1.00 | 1,70,020 | 1,70,020 |
| 35 | Supply a n d Provision o f H R C Fu s e ( base and carrier with 4/6/10/16/20A/32 A fuse as per the load condition at location boxes, cable h u t s e t c . a s p e r a p p r o v e d circuit diagram. This work also includes painting of particulars o f H R C fuse b l o c k i n s t a l l e d in power panel instructed b y Railway representative at site. (HRC fuse block, Fuses, wires, C u . lugs a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor.) | Numbers | 40.00 | 459.97 | 18,398.8 |
| 36 | Supply of Power Panel for IPS Room (using phynolic sheet 1200mm x 1200mm x 10mm and erecting it using MS angles 25mm x 25mm x 6mm and fixing of meters, stabilizer and ammeter b y pass switches, H RC fuse blocks, P B T terminals 6 0 m m centre and connecting the power equipments t o the power panel a s p e r approved power diagram, in the power room.) | Numbers | 1.00 | 31,873.7 | 31,873.7 |
| 37 | Supply of Stackable type VRLA batteries 2V, 300Ah - 1 c e l l a s per RDSO Specifications IRS S: 93/96 with Amnd 1 or latest | Numbers | 24.00 | 5,575 | 1,33,800 |
| 38 | "Supply, installation and wiring of 230/24V - 1A transformer rectifier conforming to RDSO spec. IRS S 91/2014 with latest Amendment in power room for LVR" | Numbers | 1.00 | 12,335.32 | 12,335.32 |
| 39 | Supply of IPS to suit 6 Line R E station as per R D S O Specifications RDSO/SPN/165 or latest (This schedule d o e s n o t include Batteries) As per drawing enclosed | Set | 1.00 | 13,07,398.11 | 13,07,398.11 |
| 40 | Supply of Low maintenance secondary cells of t h e following capacities with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 132.00 | 3,379.2 | 4,46,054.4 |
| 41 | Supply of Low maintenance secondary cells of t h e following capacities with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document.d)Supply of Secondary cells - 2V-200AH capacity | Numbers | 60.00 | 7,040 | 4,22,400 |
| 42 | Supply of track feed battery charger IRS:S 89-2013 | Numbers | 33.00 | 4,375.25 | 1,44,383.25 |
| 43 | Supply of 'B type choke IRS:S 65-83 | Numbers | 66.00 | 2,855.6 | 1,88,469.6 |
| 44 | Supply o f Modular Terminal Block of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers | 2000.00 | 194.95 | 3,89,900 |
| 45 | Supply of DIN channel for the terminal | Metre | 15.00 | 344.87 | 5,173.05 |
| 46 | S u p p l y o f E N D p l a t e s f o r modular terminal block | Numbers | 124.00 | 36.86 | 4,570.64 |
| 47 | S u p p l y o f E N D c l a m p f o r modular terminal block | Numbers | 114.00 | 26.35 | 3,003.9 |
| 48 | Supply o f operating tool, screw driver and stripper f o r m o d u l a r terminal. These tools shall b e o f Wago/Phoenix make or similar and model suitable for the modular terminal supplied | Numbers | 1.00 | 12,246.29 | 12,246.29 |
| 49 | "Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor" | Numbers | 1.00 | 25,774.2 | 25,774.2 |
| 50 | "Installation o f distilled w a t e r plant with provision o f w a t e r supply connection from water t a p t o water t a n k , w a t e r t a n k to distilled water plant using G . I Pipes 25mm dia and with regulating valves, provision of separate p o w e r s u p p l y s o c k e t and wiring. This work includes fixing of 2 Nos. of rails on the wall a n d grouting a s i n s t r u c t e d by Railway representative at site. (Cut rails will be supplied by Railways)." | Numbers | 1.00 | 11,745.65 | 11,745.65 |
| 51 | I n s t a l l a t i o n o f 1 6 - C h a n n e l Earth Leakage Detector. T h i s includes transportation of materials t o Site location and provision of cable trough arrangements including connection to the BRC earth. Also includes carrying out of pre-commission checklist. | Numbers | 1.00 | 17,586.67 | 17,586.67 |
| 52 | Commissioning of IPS, this schedule includes arrangement of OEM engineer f o r checking the Installation and carrying out adjustments of IPS m o d u l e s a n d s u b m i s s i o n o f Pre- commissioning checklist | Set | 1.00 | 59,000 | 59,000 |
| 53 | Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 or latest.This work includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This a l s o includes wiring o f a l l modules, proper earthing of equipments and all other works connected for testing and commissioning of the same. Necessary powdered c o a t e d Aluminium ladder arrangements including cable trench, pipes, bolts, a n d other accessories is included in this schedule.[Earthing is not covered under this schedule] | Set | 1.00 | 77,160.07 | 77,160.07 |
| 54 | Fixing o f Modular terminal block/fuse block along w i t h accessories with provision of fixing h o l e s o n hylam sheet/side angles of Location Box and fixing b y Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers | 2000.00 | 28.97 | 57,940 |
| 55 | Supply o f 2 4 Core x 1 . 5 Sq.mm PVC i n s u l a t e d Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre 58000.00 | — | 388.15 | 2,25,12,700 |
| 56 | S u p p l y o f 1 2 C x 1 . 5 S Q M M PVC insulated Armoured, unscreened underground Railway Signalling copper cable a s p e r I R S : S-63/2014 REV.4 | Metre 55000.00 | — | 215.92 | 1,18,75,600 |
| 57 | "Supply of 2x2.5 sq.mm PVC insulated Armoured, unscreened, underground Railway Signalling Copper cable as per spec IRS.S.63/2014(Rev.4.0) or latest" | Metre 12000.00 | — | 98.76 | 11,85,120 |
| 58 | Supply o f Underground j e l l y fi l l e d 6 QUAD, 0.9MM Dia a s p e r spec IRS:TC 30-05 with amd 5 or latest | Metre 35000.00 | — | 301.05 | 1,05,36,750 |
| 59 | Supply of 24 Fibre armoured OFC cable as per R D S O Specification RDSO/SPN/TC/ 110/2020 Rev. 0 or latest | Metre | 6000.00 | 95.23 | 5,71,380 |
| 60 | Supply of 48 Fibre armoured OFC cable as per R D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest | Metre 21000.00 | — | 126.32 | 26,52,720 |
| 61 | S u p p l y o f P o l y t h e n e Insulated Polythene Sheathed armoured Jelly Filled Telephone Cable with Poly-AL Moisture Barrier, 10 Pairs, 0.63 MM Conductor Diameter as per RDSOSpecification N o . IRS:TC-41/97 with amendment 1 or latest | Metre | 500.00 | 123.9 | 61,950 |
| 62 | "Supply of OFC Patch cord (FC-PC/SC- PC/LC- PC t o FC-PC/SC-PC/LC-PC s o as to suit for switches and FMS supplied)" | Metre | 30.00 | 374.03 | 11,220.9 |
| 63 | supply of switch board cable, finolex/Deltron make or better 0.5mm, 50 pair conforming to IRS/TC/24-91 | Metre | 30.00 | 230.13 | 6,903.9 |
| 64 | Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R&M o r AMP o r Molex or Krone Or D-LinkMakes | Metre | 300.00 | 34.73 | 10,419 |
| 65 | Supply o f Digital Distribution Frame (120 ohms)for terminating 1 6 E 1 s of wrapping type & Mountable on 19" rack similar to TVSmake or better. | Numbers | 2.00 | 6,309.53 | 12,619.06 |
| 66 | Supply a n d fixing o f 3 2 w a y U-Link panels (Wrapping type )with U links and mountable on 19"rack. | Numbers | 4.00 | 13,523.03 | 54,092.12 |
| 67 | Supply a n d provision o f normal joint using Thermo shrink jointing kit (RDSO s p e c s No TC/77/2012 ( Re v. 3 ) with amendment No.1&2 o r latest.& jointing kit t o be inspected b y RDSO) f o r 4 / 6 quad cable normal joint. The work includes excavation of joint pit of size 1mX1.5mX1.5m and closing the same after completion of cable joint as p e r t h e i n s t r u c t i o n o f Railway representative at site. | Numbers | 30.00 | 4,628.91 | 1,38,867.3 |
| 68 | Supply and installation of 24 Fibre Joint enclosure f o r armoured optical fibre cable conforming t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 6.00 | 13,647.37 | 81,884.22 |
| 69 | Supply and installation of 48 fibre Joint enclosure f o r armoured optical fibre cable conforming to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 10.00 | 20,060 | 2,00,600 |
| 70 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions o f Railway representative a t site.) as per drawing enclosed | Numbers | 450.00 | 262.65 | 1,18,192.5 |
| 71 | Preparation of Cement concrete for covering of G I Pipes/cables. Providing & Laying in position cement concrete o f specified proportion including cost o f cement, centering a n d shuttering w ith 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and all o t h e r misc materials required for the work should be supplied by Contractor). | cum | 130.00 | 9,361.46 | 12,16,989.8 |
| 72 | Laying of STP/OFC/Power Cable/ switch board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case c a p i n g and c l a m p i n g on the w a l l / Ro o f tops/ Shelters w i t h suitable clamping and hose to be provided where ever bends/ curves (PVC conduit/ Case capping and other accessories to be supplied by the contractor) | Metre | 4800.00 | 37.3 | 1,79,040 |
| 73 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 900.00 | 64.1 | 57,690 |
| 74 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying o f c a b l e s i s n o t i n c l u d e d i n this schedule.) | Metre | 100.00 | 32.05 | 3,205 |
| 75 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0 . 6 m to accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s per t h e i n s t r u c t i o n s of Railway Representatives a t s i t e . ( L a y i n g of cables is not included in this schedule). | Metre | 100.00 | 314.41 | 31,441 |
| 76 | Breaking o f Platform concrete having 0.3 feet thickness - 0.5 feet thickness and to a width of 0.3 Mtr using cutter machine and removal of RCC slabs on the Passenger Platform, trenching to a depth o f 0 . 6 m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering w i t h cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 100.00 | 2,224.44 | 2,22,444 |
| 77 | Excavation of trench along route of existing cable duct, opening the slabs to accommodate a d d i t i o n a l cable laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t site. (Laying of cables is not included in this schedule.)[Cement,M Sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 1300.00 | 161.92 | 2,10,496 |
| 78 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site after l a y i n g o f D W C / RC C p i p e s . During excavation o f trench, i t h a s t o be ensured that the excavated soil does not mix with the ballast available. The depth o f 1 m trench shall b e from the bottom of sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 300.00 | 385.45 | 1,15,635 |
| 79 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 60.00 | 501.03 | 30,061.8 |
| 80 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 360.00 | 208.54 | 75,074.4 |
| 81 | Construction of Support for the GI pipes laid in RCC Box type bridges | Numbers | 10.00 | 367.41 | 3,674.1 |
| 82 | Provision of GI pipes 50mm/100mm dia on excavated trenches/platforms/over the ground without abutments and supports | Metre | 60.00 | 118.22 | 7,093.2 |
| 83 | Provision o f G I pipes (50/100mm dia) for cable laying in hard rocky area with off sets at b o t h e n d s duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes s h a l l b e closed w i t h b r i c k masonry abutments work so that no cable is exposed, The work shall be carried out a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 312.00 | 182.87 | 57,055.44 |
| 84 | L a y i n g o f signaling/power/ telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this schedule). | Metre 160500.00 | — | 18.18 | 29,17,890 |
| 85 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating t h e trench by ramming and levelling." | Metre | 900.00 | 15.4 | 13,860 |
| 86 | "Refilling o f cable trench 0 .5 m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling." | Metre | 100.00 | 7.77 | 777 |
| 87 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g of concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation a n d refilling t h e p i t and consolidating it by ramming. The cable m a r k e r s s h a l l b e p r o v i d e d a t an interval of 20 Mtrs. within station limits a n d 5 0 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing." | Numbers | 450.00 | 123.35 | 55,507.5 |
| 88 | Excavation of cable coil pit to a size of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables i n r e a r o f relay rooms/ A F T C huts, apparatus cases e t c . T h e w o r k includes coiling the u n d e r g r o u n d c a b l e s a n d placing closely one layer o f country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks o f size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 30.00 | 949.05 | 28,471.5 |
| 89 | Cutting of rock up to a depth of 300 mm and width of 300mm where rock is visible from surface, concreting to ground level after laying cables with 1 c e m e n t : 2 s a n d : 4 graded stone aggregate 20mm nominal size and c u r i n g o f concrete t o t h e required number of days, except in bridges, culverts, level c r o s s i n g s , track c r o s s i n g s , c a b l e pits, rocky soil including marking o f cable alignment, clearing of debris etc., complete to the finished ite m o f w ork a s directed by site in-charge. Drg.No.SK/CN/NEW/1. All the material is to be arranged by contractor | Metre | 500.00 | 600.96 | 3,00,480 |
| 90 | " R o a d c r o s s i n g / T r a c k Crossing through Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion of HDPE /DWC pipe of size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a H D P E p i p e o r any other combination a s directed b y the site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre | 650.00 | 1,351.45 | 8,78,442.5 |
| 91 | Blowing/Drawing o f O F C cable/Power c a b l e / S i g n a l l i n g c a b l e inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated HDPE pipe. ( This includes Transportation o f m a t e r i a l s from nominated stores to site) | Metre 27000.00 | — | 23.43 | 6,32,610 |
| 92 | Supply of Main LED Signal Aspect - Green as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 12.00 | 10,030 | 1,20,360 |
| 93 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 20.00 | 8,850 | 1,77,000 |
| 94 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 18.00 | 9,233.5 | 1,66,203 |
| 95 | Supply o f subsidiary Signal Aspect - Route LED as per RDSO Specifications S P E C I F I C A T I O N NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 35.00 | 5,703.33 | 1,99,616.55 |
| 96 | Supply of subsidiary Signal Aspect - Calling on L E D a s p e r RDSO Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 13.00 | 5,726.13 | 74,439.69 |
| 97 | Supply o f subsidiary Signal Aspect - Shunt LED a s p e r RDSO Specification S P E C I F I C A T I O N NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 45.00 | 5,740.7 | 2,58,331.5 |
| 98 | S u p p l y o f C o l o u r l i g h t S i g n a l pole 140mm dia, 4 . 6 m / 3 . 6 m t a l l with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) | Numbers | 4.00 | 5,841 | 23,364 |
| 99 | S u p p l y o f C o l o u r l i g h t S i g n a l pole 140mm dia, 4 . 6 m / 3 . 6 m t a l l with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers | 16.00 | 4,737.7 | 75,803.2 |
| 100 | Supply o f surface b a s e t o s u i t CLS Signal pole 140mm dia with necessary inspection as p e r specification/ drawing/ description enclosed in this document. | Numbers | 20.00 | 6,814.5 | 1,36,290 |
| 101 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply of l a d d e r w i t h p l a t f o r m ( 4 . 6 m ) for CLS(Galvanised) | Numbers | 4.00 | 5,698 | 22,792 |
| 102 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of l a d d e r w i t h p l a t f o r m ( 3 . 6 m ) for CLS(Galvanised) | Numbers | 16.00 | 5,494.5 | 87,912 |
| 103 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as per s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. | Numbers | 7.00 | 5,087.5 | 35,612.5 |
| 104 | Supply o f Ground type shunt signal - complete w i t h surfa c e b a s e , signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 9.00 | 7,463.5 | 67,171.5 |
| 105 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary i n s p e c t i o n a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers | 10.00 | 16,874 | 1,68,740 |
| 106 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary i n s p e c t i o n a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 10.00 | 14,278 | 1,42,780 |
| 107 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. a) Supply of Junction type route indicator - 1 way | Numbers | 3.00 | 15,121.7 | 45,365.1 |
| 108 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way | Numbers | 1.00 | 22,260.7 | 22,260.7 |
| 109 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal | Numbers | 11.00 | 3,663 | 40,293 |
| 110 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as p e r specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 4.00 | 3,569.5 | 14,278 |
| 111 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as p e r specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 7.00 | 2,645.5 | 18,518.5 |
| 112 | Supply of Signal post telephone with facility of p a g i n g a n d talk-back i n c l u d i n g voice communication e q u ip m e n t w i t h suitable switching arrangement at the Signal post and at S M ' s r o o m a s p e r specification e n c l o s e d i n t h i s d o c u m e n t . This includes drawl of tail cable through GI pipe 25mm dia and 2 mtrs long duly clamped to Signal post with bend as required a t site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table t o p . T h e wiring shall b e done using wire PVC 16/0.2mm copper. [ Ta l k - b a c k e q u i p m e n t complete including housing b o x , w i r e PVC 1 6 / 0 . 2 0 m m a n d all other miscellaneous materials required for t h e w o r k s h a l l b e supplied b y the Contractor]. | Numbers | 4.00 | 11,897.35 | 47,589.4 |
| 113 | S u p p l y o f plug-in t y p e , S t y l e QL1, Magnetically Latched Neutral Line 24V DC, 11F/4B contacts Relay complete w i t h plug board (base plate), connectors and retaining clips and conforming to BRS 935A and RDSO Spn. No IRS S34 and S-23 or latest. The interlocking code for this unit shall be "ABDEG" | Numbers | 22.00 | 7,076.52 | 1,55,683.44 |
| 114 | Supply of Plug in Type Q-Series Relay QBAT (2F/2B)(Miniature, Tractive armature, AC Immune, D . C Biased Track Relay) A.C. immunity level of 80 Volt A.C, coil nominal resistance o f 9 O h m s , confirming t o BRS spec no. 939A & 966F2 and RDSO specification No. 8 4 / 8 8 o r latest. The interlocking code for this unit shall be "ABEJX" | Numbers | 6.00 | 9,858.79 | 59,152.74 |
| 115 | Supply of Relay, Non-AC Immune, plug-in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 250.00 | 4,366.63 | 10,91,657.5 |
| 116 | Supply of Relay, AC Immune, plug-in- type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers | 250.00 | 4,639.03 | 11,59,757.5 |
| 117 | Supply of electronic time delay units (120/60 secs) w i t h p l u g boards, connectors and retaining c l i p s with n e c e s s a r y i n s p e c t i o n as per s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. | Numbers | 4.00 | 2,742.03 | 10,968.12 |
| 118 | Supply of lamp proving relays(QECX- 61) for a)LED a s p e c t s w i t h plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 90.00 | 5,901.5 | 5,31,135 |
| 119 | Supply of QBCA1 - heavy duty contact relays with necessary inspection as per specification/ | Numbers | 33.00 | 6,613.75 | 2,18,253.75 |
| 120 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 r e l a y s / p l u g i n t y p e as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , w i r i n g a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g r e s is t o r s and condensers, M S fl a t s 2 5 m m x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 40.00 | 4,945.51 | 1,97,820.4 |
| 121 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 r e l a y s / p l u g i n t y p e as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , w i r i n g a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g r e s is t o r s and condensers, M S fl a t s 2 5 m m x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 5.00 | 8,786.26 | 43,931.3 |
| 122 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 r e l a y s / p l u g i n t y p e as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , w i r i n g a n d termination as per approved circuit diagram and painting the particulars.[Wire P V C copper, 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , f o r fi x i n g r e s is t o r s and condensers, M S fl a t s 2 5 m m x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 2.00 | 11,355.02 | 22,710.04 |
| 123 | Supply of QTA2 - track relays with plug boards, connectors and retaining clips with necessary inspection as per specification | Numbers | 32.00 | 4,070 | 1,30,240 |
| 124 | Supply of QSPA1 type relays with plug boards, connectors and retaining clips with necessary inspection a s per specification/drawing/ | Numbers | 38.00 | 7,139 | 2,71,282 |
| 125 | Supply of powder coated FTOT o f 500 capacity | Numbers | 5.00 | 50,593.8 | 2,52,969 |
| 126 | Concreting and e r e c t i o n o f cable t e r m i n a t i o n r a c k 500/210/140 Terminals capacity o n teakwood base f r a m e o f size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in t h e cables a n d painting as per standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation b o l t s and n u t s w i t h washers, cement, sand, s t o n e j e l l y , t e a k w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity | Numbers | 5.00 | 13,668.26 | 68,341.3 |
| 127 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram b o a r d u s i n g p l y w o o d of thickness 1 2 m m - t e a k w o o d fi n i s h o f size 1800mm x 1200mm w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination r a c k s h a l l be c o v e r e d with phynolic s h e e t of thickness 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ nylon s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply o f PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and n u t s a n d washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s bars, teakwood 5 0 m m x 50mm for cable c l a m p s , 2 5 m m x 1 0 0 m m f o r base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 2250.00 | 167.99 | 3,77,977.5 |
| 128 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram b o a r d u s i n g p l y w o o d of thickness 1 2 m m - t e a k w o o d fi n i s h o f size 1800mm x 1200mm w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination r a c k s h a l l be c o v e r e d with phynolic s h e e t of thickness 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ nylon s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply o f PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and n u t s a n d washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s bars, teakwood 5 0 m m x 50mm for cable c l a m p s , 2 5 m m x 1 0 0 m m f o r base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination using PBT fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 250.00 | 201.27 | 50,317.5 |
| 129 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e w o r k includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all o t h e r m i s c e l l a n e o u s materials required for the work shall be supplied by the Contractor]. | Per Relay | 50.00 | 695.67 | 34,783.5 |
| 130 | S u p p l y o f aspiratio n t y p e smoke detector. Highly sensitive smoke aspiration system for Monitoring of r o o m s a n d equipment's for earliest possible fire detection For Relay rooms a s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 7,08,081.12 | 7,08,081.12 |
| 131 | S u p p l y o f s i n g l e L o o p Analog addressable Fire A l a r m system with loop capacity of connecting maximum 50 devices. The panel shall h a v e a b u i l t i n p o w e r s u p p l y and battery c h a r g e r R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 3,11,682.08 | 3,11,682.08 |
| 132 | Supply of Multi Sensor detector Dual Optical/ Thermal a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 50.00 | 16,042.23 | 8,02,111.5 |
| 133 | Supply o f Addressable Single action indoor manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,494.38 | 9,494.38 |
| 134 | Supply of Sounder having range of 81 dbA to 92 d b A a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 2.00 | 11,420.51 | 22,841.02 |
| 135 | S u p p l y o f I n t e l l i g e n t addressable Monitor module a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 6.00 | 9,494.38 | 56,966.28 |
| 136 | S u p p l y o f I n t e l l i g e n t addressable control module a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 6.00 | 9,494.38 | 56,966.28 |
| 137 | Supply o f Auto-dialer f o r S M S alarm generation & routing in case of Fire Alarm to concerned persons a s per RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 43,931.48 | 43,931.48 |
| 138 | S u p p l y o f 2 c o r e 1 . 5 s q . m m FRLS Copper unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 350.00 | 296.94 | 1,03,929 |
| 139 | S u p p l y o f L H S C a b l e R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 150.00 | 2,246.07 | 3,36,910.5 |
| 140 | Supply of L H S control module. RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 1,55,660.6 | 1,55,660.6 |
| 141 | Supply and Installation of Air sampling CPVC Pipes w i t h a l l required accessories for Aspiration system) | Set | 1.00 | 76,137.76 | 76,137.76 |
| 142 | Supply of BIS listed semi-automatic stainless steel fire extinguisher with UL approved clean gas with auto manual reverse stainless steel valve 'NASA 200 MAR' or similar having capacity of 2kg, and made of stainless steel 304 grade with Indian Railway logo put on each unit. | Per Unit | 7.00 | 24,780 | 1,73,460 |
| 143 | Supply o f Relay Module a s p e r RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,867.99 | 9,867.99 |
| 144 | Supply of TCIP Module /Networking card for interfacing the Fire Alarm and Detection systems | Numbers | 1.00 | 30,881.44 | 30,881.44 |
| 145 | Installation, testing and commissioning charges of fire alarm system including programming of devices and fire alarm panel | Set | 1.00 | 95,933.57 | 95,933.57 |
| 146 | Supervision, programming,testing & Commissioning o f Aspiration smoke detection | Set | 1.00 | 83,751.53 | 83,751.53 |
| 147 | Supply of SPD Life tester, designed for on- site testing o f s u r g e protective devices (SPD). It shall indicate the health status of GDT/ MOV based SPD of voltage range upto 1000V. It shall indicate the status of SPD by measuring its electrical parameters. | Numbers | 1.00 | 1,20,729.41 | 1,20,729.41 |
| 148 | Supply o f B l o c k Filter U n i t u s e d in conjunction w ith block instrument in 25KV, 50Hz AC traction area as per specification No IRS:S-68/89 including latest amendment | Numbers | 2.00 | 18,161.86 | 36,323.72 |
| 149 | Supply of Thermal Imager Pocket, with accessories as per Technical specification | Numbers | 1.00 | 1,06,188.2 | 1,06,188.2 |
| 150 | Supply o f Coating Thickness Gauge, with accessories, as per Technical specification | Numbers | 1.00 | 29,500 | 29,500 |
| 151 | Supply of Hydrometer | Numbers | 2.00 | 228.94 | 457.88 |
| 152 | S u p p l y o f G I p i p e s - 5 0 m m d i a - 3.65mm thick as per Technical specification | Metre | 180.00 | 457.88 | 82,418.4 |
| 153 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 552.00 | 1,119.16 | 6,17,776.32 |
| 154 | Supply o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 M e t e r s a s per specification N o . I S 4984: 2016 with l a t e s t a m e n d m e n t s a n d Material Grade:PE 80 | Metre | 650.00 | 853.55 | 5,54,807.5 |
| 155 | S u p p l y a n d l a y i n g o f P V C Warning Tape colour Orange, width o f 250mm ( 1 0 " ) by printing w i t h b l a c k letters ' I n d i a n RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 1000.00 | 46.15 | 46,150 |
| 156 | Supply of Electronic Cable Route Marker 3M make o r similar, Model: R F I D ( 1 4 2 1 ) and installation, cable detection o f capacity to detect the cable upto 5 feet depth. | Numbers | 500.00 | 2,441.72 | 12,20,860 |
| 157 | Supply o f H D P E P i p e 4 0 m m (outer dia)/33 mm (inner dia) with couplers | Metre 27000.00 | — | 60.93 | 16,45,110 |
| 158 | Supply a n d Installation o f Wall/Rack m o u n t a b l e 2 4 F i b r e management system (FMS) c o n f o r m i n g to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 or latest similar to COMMSCOPE make or better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length ( A l l other materials required for splicing are to be supplied by contractor ) | Numbers | 7.00 | 18,686.74 | 1,30,807.18 |
| 159 | Supply a n d Installation o f Wall/Rack m o u n t a b l e 4 8 F i b r e management system (FMS) c o n f o r m i n g to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 or latest similar to COMMSCOPE make or better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos o f Patch cords of required length (All other materials required for splicing are to be supplied by contractor) | Numbers | 8.00 | 32,885.01 | 2,63,080.08 |
| 160 | Supply and Installation of surface Wall mountable type 1 9 inch 1 2 U network Rack with front glass doo r w i t h lock a n d rack fixing multipoint A C Power trip & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager) | Numbers | 8.00 | 6,761.51 | 54,092.08 |
| 161 | Supply and Installation of covered 19inch Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories | Numbers | 3.00 | 65,734.12 | 1,97,202.36 |
| 162 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. | Numbers | 160.00 | 1,622.5 | 2,59,600 |
| 163 | Supply of Track Feed Resistance | Numbers | 33.00 | 287.77 | 9,496.41 |
| 164 | Supply of PBT terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 9000.00 | 61.44 | 5,52,960 |
| 165 | Supply of PBT terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 4000.00 | 93.02 | 3,72,080 |
| 166 | Supply of PBT terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 500.00 | 103.84 | 51,920 |
| 167 | Supply o f 4 w i r e D T M F b a s e d way station equipment complete a s per RDSO specification No.IRS.TC@45<47@93 a n d 4 wire control telephone with audio visual indication and reset button fitted on telephone conforming to specification No.IRS-TC@45&47@97 or latest. | Set | 2.00 | 9,086 | 18,172 |
| 168 | Manufacture and supply of teak wood tool box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g. Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k . Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o. Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site.[Teak wood tool box made o f 25mm teak wood plank, perspex sheet, all the tools mentioned a b o v e , p a d l o c k a n d other miscellaneous items shall be supplied by the Contractor]. | Set | 1.00 | 29,185.6 | 29,185.6 |
| 169 | Supply a n d installation o f teakwood glass fronted b o x o f s i z e 3 0 0 m m x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for t h e w o r k s h a l l b e supplied b y the Contractor]. | Numbers | 5.00 | 7,505.45 | 37,527.25 |
| 170 | Installation of combined type point machine-IRS type a n d connecting all ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose p i p e w i t h 3/0.75mm and 7/1.40mm copper w ire a n d painting. This work includes provision o f insulation to stretcher bars, throw bar lug a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire P V C 7/1.4mm copper, P V C hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 17.00 | 16,383.88 | 2,78,525.96 |
| 171 | Painting of existing colour light Signals as per standard practice. T h e work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel p a i n t o n the Signals - complete as instructed by Railway representative at site. [Aluminium paint, red-oxide a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 4.00 | 2,442 | 9,768 |
| 172 | F i l l i n g e a r t h a r o u n d location boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below t h e foundation top. T h i s work includes consolidation of earth by watering and ramming.The earth shall b e taken from Railway premises as instructed by Railway representative at site. | cum | 5.00 | 231.3 | 1,156.5 |
| 173 | Excavatio n o f pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection of colour light signals up to 4 aspects. [Foundation bolts, cement, M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 20.00 | 9,213.28 | 1,84,265.6 |
| 174 | "Erection o f surface base, signal pole, mounting of colour light signal up to 4 aspects complete o n Signal pole/ Off- set bracket, (for LED/ filament bulbs) with lenses, triple p o l e l a m p holder, filament switching u n i t s , CLS t r a n s f o r m e r , current regulators (whichever is applicable), fixing of l a d d e r w i t h platform complete and concreting o f ladder s h o e , fi x i n g of number plates, m a r k e r b o a r d , lens g u a r d , fi x i n g of speed l i m i t board wherever necessary, termination of tail cables, wiring o f signal unit with PVC w i r e 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through b o l t s h a l l be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects c o m p le t e , l a d d e r with shoes and platform, Speed limit board, LED a s p e c t s , c u r r e n t r e g u l a t o r s , lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone j e l l y 20/25mm d i a , M sand, Signal C o l l a r R i n g s , w i r e P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead w o o l , p a i n t s PVC/Nylon sleeves, enameled n u m b e r plates. enameled marker boards, E W S locks, and a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 20.00 | 8,287.08 | 1,65,741.6 |
| 175 | "Excavation of pit and casting concrete foundation as per Drg, No.SG/CN/02/10 using metallic templates, f o r erection of ground t y p e c o l o u r l i g h t shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 9.00 | 4,645.17 | 41,806.53 |
| 176 | "Erection o f Ground type shunt signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing o f lens guards, number plate, termination o f tail cables, wiring of signal u n i t w i t h P V C wire 3/0.75mm copper, provision o f E W S locks and painting o f one coat o f red oxide and two coats of Aluminium/ enamel paint. (Supply o f Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this s c h e d u l e ) . [ W i r e PVC 3/0.75mm c o p p e r , l e n s g u a r d s , E W S locks, Enameled number plates, b o l t s and nuts, lead wool, paints and all other miscellaneous materials s h a l l be supplied by the Contractor]." | Numbers | 9.00 | 3,170.44 | 28,533.96 |
| 177 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f Post type shunt Signals, termination o f tail cables and w i r i n g using wire P V C 3/0.75mm copper, provision of EWS l o c k and painting of one coat of red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n t h e C L S p o s t and provision of a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 7.00 | 2,306.03 | 16,142.21 |
| 178 | Fixing of junction type route indicators - 1 way to 6 ways - complete/ fixing of additional lim b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. ( S u p p l y o f j u n c t i o n t y p e Route Indicators - complete and additional limb is not covered in this schedule). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing a n d w i r i n g o f direction t y p e route indicator - 1 way | Numbers | 3.00 | 2,238.04 | 6,714.12 |
| 179 | Fixing of junction type route indicators - 1 way to 6 ways - complete/ fixing of additional lim b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. ( S u p p l y o f j u n c t i o n t y p e Route Indicators - complete and additional limb is not covered in this schedule). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing a n d w i r i n g o f direction t y p e route indicator - 3 way | Numbers | 1.00 | 2,679.26 | 2,679.26 |
| 180 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 14.00 | 8,914.5 | 1,24,803 |
| 181 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 16.00 | 7,145.44 | 1,14,327.04 |
| 182 | Alteration to existing DC Track Circuits to suit RE/Non R E standard a s per approved signaling p l a n . T h i s work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 4.00 | 4,234.65 | 16,938.6 |
| 183 | Alteration to existing DC Track Circuits to suit RE/Non R E standard a s per approved signaling p l a n . T h i s work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 4.00 | 3,850.31 | 15,401.24 |
| 184 | Excavation o f p i t , casting concrete foundation a n d erection o f apparatus case full s i z e a s p e r Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly o f s i z e 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and a l l other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers | 75.00 | 11,333.1 | 8,49,982.5 |
| 185 | "Excavation o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock f o r t h e f r o n t d o o r and latching arrangement for the back door, and fi x i n g o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]""" | Numbers | 15.00 | 8,787.04 | 1,31,805.6 |
| 186 | Excavation o f p i t , erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r cable throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide a n d t w o c o a t s of aluminium paints.(Supply o f C T boxes is not covered in this schedule. Rails of different length shall be supplied by Railways. T h e contractor shall cut lengthy rails wherever required.) [Cement, M sand, stone jelly o f size 20/25mm, p a i n t , varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts a n d n u t s with washers, E W S locks, p a i n t s a n d a l l other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 5.00 | 4,999.16 | 24,995.8 |
| 187 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables a n d shifting and turning the location boxes to clear of the infringement as instructed b y t h e Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes t o the required level shall be done as instructed by the Railway representative a t site. I f the e x i s t i n g e a r t h connections t o the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers | 5.00 | 5,348.81 | 26,744.05 |
| 188 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables a n d shifting and turning the location boxes to clear of the infringement as instructed b y t h e Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes t o the required level shall be done as instructed by the Railway representative a t site. I f the e x i s t i n g e a r t h connections t o the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers | 5.00 | 3,545.06 | 17,725.3 |
| 189 | Termination of new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ battery b o x e s / CT boxes/ cable termination racks a s per approved circuit diagram. The terminal p a r t i c u l a r s a r e to be repainted /corrected o n t h e doors of apparatus c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing t h e opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases w i t h masonry brick work and sealing t h e bottom o f the apparatus cases/ c a b l e termination r a c k s w i t h cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm c o p p e r , s e a l i n g c o m p o u n d , bricks, cement, M sand and all other required miscellaneous materials s h a l l be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 150.00 | 73.59 | 11,038.5 |
| 190 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges e x c l u d i n g cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n the terminal b o a r d , drilling of necessary holes, termination o f cables, wiring, identification o f c a b l e s using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting o f particulars on sleeves andalso on the inner side of t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall b e sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination on 25/60mm PBT terminals (new location) (Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit 10750.00 | — | 172.14 | 18,50,505 |
| 191 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges e x c l u d i n g cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n the terminal b o a r d , drilling of necessary holes, termination o f cables, wiring, identification o f c a b l e s using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting o f particulars on sleeves andalso on the inner side of t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall b e sealed w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet) (Per Unit = Per Fuse block) | Per Unit | 250.00 | 209.93 | 52,482.5 |
| 192 | Painting o f existing apparatus case (Inside and Outside) - Full size | Numbers | 5.00 | 2,365.69 | 11,828.45 |
| 193 | "Painting of existing apparatus case (Outside) - Full size" | Numbers | 5.00 | 1,182.15 | 5,910.75 |
| 194 | Painting o f existing apparatus case (Inside and Outside) - Half size | Numbers | 5.00 | 2,263.01 | 11,315.05 |
| 195 | "Painting of existing apparatus case (Outside) - Half size" | Numbers | 5.00 | 1,132.2 | 5,661 |
| 196 | Installation o f s i n g l e line FM type tokenless block instruments on the block counter. The work involves termination of cables on the test panel a n d b l o c k c o u n t e r , b l o c k wiring, interconnection between t e s t panels and block instrument b y underground signaling cable and painting the instrument as per the instructions of Railway representative at site.(Supply o f block instruments, block counters and underground cables is not covered in this schedule).fixing terminals, wire P V C 1 6 / 0 . 2 m m c o p p e r , 3/0.75mm, paint, and all other miscellaneous materials required f o r t h e w ork shall be supplied by the contractor]. | Numbers | 2.00 | 16,783.2 | 33,566.4 |
| 197 | Provision of signaling arrangement during Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station | 2.00 | 33,631.06 | 67,262.12 |
| 198 | Provision o f P A system a n d Magneto telephone communication a t stations/ tents as per the instructions of Railway representative a t site. The P A system and magneto telephones will be returned to the contractor after the completion o f NI working. Signalling cables available may be used for the communication.(Hiring o f P A system equipments and magneto telephones shall b e d o n e b y the Contractor)[All other miscellaneous materials required for the work shall b e supplied b y the Contractor]. (Per Unit= Per set per day) | Per Unit | 6.00 | 1,637.25 | 9,823.5 |
| 199 | Installation and wiring of existing Way station equipment DTM F a n d control telephones. T h e w o r k involves fixing the released way station equipment on the wall at an appropriate place in consultation with Railway representative a t s i t e , w i r i n g and interconnecting t h e s a m e w i t h test panel, control telephones and batteries.(Supply o f w a y station equipment, control telephones and b a t t e r ie s i s n o t i n c l u d e d in this schedule). [Wire PVC 3/0.75mm & 16/0.2mm copper, MS clamps for fixing arrangements, PVC tubes 25mm dia for interconnections and all other miscellaneous items required f o r the work shall be supplied by the Contractor]. | Numbers | 2.00 | 8,016.98 | 16,033.96 |
| 200 | Installation o f m a g n e t o telephones with Nicad pack | Numbers | 12.00 | 3,322.6 | 39,871.2 |
| 201 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 4.00 | 3,972.14 | 15,888.56 |
| 202 | Painting, erection a n d concreting of Goods warning boards on rails as per the Signalling plan. The work includes manufacturing of clamps and fixing the board to the rails, supply and fixing of scotch lite reflectors and concreting the rail post to a size of 600mm x 600mmx900mm. (Supply o f goods warning boards are not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor h a s t o c u t t h e m t o the required lengths).[Stone jelly o f size 2 0 / 2 5 m m d i a , M sand, cement, M.S.flats, scotch lite strips (14 Nos) for each board, fixing bolts and nuts, paint and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 4.00 | 5,398.39 | 21,593.56 |
| 203 | Provision of HDPE Pipe of dia 40/33 mm | Metre 27000.00 | — | 26.11 | 7,04,970 |
| 204 | Laying o f DWC/Split D W C P i p e s for Track Crossing/Road Cutting/Trenches | Metre | 1800.00 | 42.46 | 76,428 |
| 205 | "Releasing o f existing r e l a y racks/ cable termination racks along with all the terminals, fuse blocks, relays, with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing, t h e fl o o r shall b e levelled and cement plastered" | Rack | 5.00 | 1,977.19 | 9,885.95 |
| 206 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly a t a p l a c e as instructed b y Railway representative at site. Also the resultant pits shall be r e - s u r f a c e d a n d consolidating by ramming and levelling" | Numbers | 2.00 | 1,580.36 | 3,160.72 |
| 207 | Releasing of existing point lay-out with facing point lock,split stretchers, e l e c t r i c a l d e t e c t o r , l o c k bars, point/trap indicators cranks, rods etc., carefully without D a m a g i n g the materials, accounting a n d stacking them neatly a t a place as instructed by Railway representative at site. | Set | 2.00 | 2,852.7 | 5,705.4 |
| 208 | Removal o f obstructing sleepers, and rails available in the path of cable trench (Above the ground) | Numbers | 50.00 | 235.47 | 11,773.5 |
| 209 | Removal o f obstructing sleepers, and rails available in the path of cable trench (buried inside ground) | Numbers | 35.00 | 3,205.7 | 1,12,199.5 |
| 210 | Jungle cutting along with the cable route | Metre | 500.00 | 5.84 | 2,920 |
| 211 | Releasing of hand plunger lock s i n g l e / d o u b l e along with switch extension pieces, stretcher bars, point/ trap indicators and o t h e r fixtures c a r e f u l l y without damaging the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Set | 2.00 | 2,389.28 | 4,778.56 |
| 212 | Releasing o f existing apparatus cases (Full/ Half/ Q u a r t e r s i z e ) without d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f a l l types E K T s , S e c o n d a r y Cells, power equipments, ' E ' type locks, etc., and b r e a k i n g t h e c o n c r e t e foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials s h a l l b e accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers | 30.00 | 3,006.71 | 90,201.3 |
| 213 | Breaking of concrete and releasing the existing cable termination boxes, after releasing t h e b a s e p l a n k , Terminal blocks, Fuse Blocks, Terminal Boards, c u t rails, pipes, e t c . , c l o s i n g the resultant pits and consolidating i t by ramming a n d levelling. The released materials s h a l l b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 2.00 | 2,004.94 | 4,009.88 |
| 214 | Releasing o f existing S M ' s control panel including base plank, and other gadgets connected very carefully without causing any damage t o the panel, accounting and stacking them neatly at a place as instructed by Railway representative a t s i t e . The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered | Set | 1.00 | 5,257.24 | 5,257.24 |
| 215 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or w i t h o u t Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the c o n c r e t e f o u n d a t i o n , c l o s i n g the resultant p i t and resurfacing it by ramming and levelling. | Numbers | 12.00 | 3,083.03 | 36,996.36 |
| 216 | Dismantling a n d releasing o f existing Point machines ( a l l t y p e s ) including ground connections a n d other a c c e s s o r i e s available complete without a n y damage t o the gadgets, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. | Numbers | 2.00 | 2,698.69 | 5,397.38 |
| 217 | Releasing o f S e c o n d a r y c e l l s and battery stands available in the battery r o o m along with connecting strips, w i r e s a n d terminal boxes carefully without causing any damage to the batteries, accounting a n d stacking them neatly at a place as instructed by Railway representative a t s i t e . After releasing a n y h o l e s i n t h e walls/ flooring shall b e fi l l e d w i t h cement mortar and plastered. | Set | 1.00 | 5,395.99 | 5,395.99 |
| 218 | Releasing of existing Block Instruments (all types), Block counters, batteries, block filter, block bell equipment etc., carefully without a n y damage, accounting and stacking them neatly at a place as instructed by Railway representative at site | Numbers | 2.00 | 1,773.23 | 3,546.46 |
| 219 | Releasing of point rods with rod roller t r e s t l e s , c o m p l e t e a s s e m b l y. This includes releasing of all cranks, compensators and 'A' type concrete foundation o n t h e r o d run. The resultant pits a r e t o be covered with earth a n d consolidated b y ramming and levelling. c)Releasing of point roddings | Metre | 20.00 | 14.71 | 294.2 |
| 220 | Releasing of existing TLD boxes with stumps and terminals after releasing a l l t h e bond wires. T h e released materials s h a l l be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 30.00 | 159.29 | 4,778.7 |
| 221 | Releasing of all power equipments including equipment stands, terminal boards, power panel etc., in the power r o o m carefully without causing any d a m a g e t o the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked a t a place as instructed by Railway representative at site. After releasing any holes in the walls/flooring s h a l l b e fi l l e d with cement mortar and plastered. | Set | 1.00 | 12,640.13 | 12,640.13 |
| 222 | R e l e a s i n g o f e x i s t i n g control equipments - complete including way station equipments, telephones, power supply for way station equipment and telephones, a l o n g w i t h all wiring, accounting and stacking them neatly a t a place a s instructed b y Railway representative at site. | Set | 1.00 | 6,012.04 | 6,012.04 |
| 223 | Survey of Cable Route and Preparation of Cable Route Plan | Kilometre | 8.00 | 716.01 | 5,728.08 |
| 224 | Videography of cable Route | Kilometre | 8.00 | 519.85 | 4,158.8 |
| 225 | P r o t e c t i o n a d j u s t m e n t s a n d re- instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 300.00 | 847.59 | 2,54,277 |
| 226 | Protection, adjustment and reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Te c h n i c i a n ) etc., for executing additional S & T portion of works. The w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination o f cables, minor patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing etc as p e r i n s t r u c t i o n of Railway representatives at size. | Man- Days | 150.00 | 1,073.45 | 1,61,017.5 |
| 227 | Transportation o f Signalling materials by road a s p e r t h e instructions of Railway representative a t s i t e . The w o r k also includes l o a d i n g and unloading o f the materials a ) Tr a n s p o r t a t i o n o f Signalling materials upto 100kms | MT-Km | 1000.00 | 22.75 | 22,750 |
| 228 | Transportation o f Signalling materials more than 100km | MT-Km 15000.00 | — | 13.91 | 2,08,650 |
| 229 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as p e r t h e i n s t r u c t i o n o f Railway representative at site. | Hour | 50.00 | 1,202.5 | 60,125 |
| Schedule total | ₹13,08,52,865.5 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NYYStation-1VolumeIPartI.pdf
ATTACHMENT
NYYStation-2VolumeIPartII.pdf
ATTACHMENT
NYYStation-3Volume_II_Ch_I__Conditions_of_Contract.pdf
ATTACHMENT
NYYStation-4VolumeIICh-IIPVC.pdf
ATTACHMENT
NYY_station_5_Volume_II_Ch_III_Specifications_of_Signaling_Works_compressed.pdf
ATTACHMENT
NYY_station_6_Volume_II_Ch_IV_Technical_conditions_10_7_Copy.pdf
ATTACHMENT
Policeverificationletter.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCcorrectionsslips_compressed.pdf
ATTACHMENT
NYYMASTERSIP_04062025.pdf
ATTACHMENT
cablecutpenaltyletter.pdf
ATTACHMENT
AnnxVclarification14052024.pdf
ATTACHMENT
corr.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .