Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.7 LAdmitted-Finance | ₹53.7 L | L1 | Admitted-Finance |
| 2 | L2₹56.6 LAdmitted-Finance KIZHAKKE PARAVILA VEEDU RANDALUMMUKKU EZHUKONE P O | PATHANAMTHITTA | KERALA | 689694 | ₹56.6 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SIVAGOPAL MG L1 | RAJAN N (MAHALEKSHMI CONSTRUCTIONS) L2 |
|---|---|---|---|---|---|
| 1.001) SITC (Supply Installation Testing and Commissioning) OF 8 Mtr LOW MAST LIGHTS WITH 4 Nos OF 100W LED FLOOD LIGHTS NEAR ANGANWADI JUNCTION - ELECTRICAL WORKS | |||||
| 1.00 | 90.15.1.1
Supply installation testing and commissioning of Octogaonal Pole made of hot dip
galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm
base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part
III fixed head frame including round arm luminary carriage suitable to install 4/6 nos
luminaries in symmetrical arrangement including connector foundation bolt 4 nos
existing RCC foundation and junction box etc, complete 8 Meters | 1 | each | 26,000 ₹26,000 | 27,584 ₹27,584 |
| 1.00 | 90.15.4.7
Supply Conveyance, installation, testing and commissioning of 100W LED Flood
light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip
make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal
surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,
acrylic cover complete with THD less than 10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment
should be seperatly accessible for maintenance (LM 79&80 certificates from NABL
accredited Third party lab to be produced mentioning chip manufacturer) | 4 | each | 9,100 ₹36,400 | 9,634 ₹38,536 |
| 1.00 | 90.14.1.2
Fabrication, supply, conveyance, installation testing and commissioning of floor or
wall mounting, dust and vermin proof, cubicle type MV panel board comprising of
the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly
as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved
design and requirement, with front and rear access facility, bus bar chambers, hinged
doors for all switch gear compartments, earthing the doors using 4 sq mm braided
copper conductor, providing necessary cut-outs for mounting meters, relays,
indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber
and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles
etc shall not be used for the fabrication of panel assembly. The measurments will be
taken the area of the complete sheets used for panel board including partitions,
folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA
sheet, powder coated (excluding base frame) | 2 | sqm | 2,250 ₹4,500 | 2,379 ₹4,758 |
| 1.00 | 90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU'
section rubber beeding suitable for 1.60/ 2.00 mm sheet | 4 | metre | 680 ₹2,720 | 7 ₹28 |
| 1.00 | 90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall
mounting panel board | 10 | kg | 250 ₹2,500 | 162 ₹1,620 |
| 1.01 | OD283174/2025-2026
Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital
timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single
core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core
copper conductor cable. | 1 | each | 1,300 ₹1,300 | 5,482 ₹5,482 |
| 1.01 | OD283177/2025-2026
Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way
neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC
insulated single core copper conductor cable. | 1 | each | 510 ₹510 | 1,792 ₹1,792 |
| 1.01 | 2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral),240
volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli
amperes in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
40 amps | 1 | each | 2,290 ₹2,290 | 2,786 ₹2,786 |
| 1.01 | 2.10.3
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Double pole | 1 | each | 610 ₹610 | 692 ₹692 |
Tender Value
₹61.8 L
EMD Value
₹50,000
Closing Date
30 Mar 2026, 3:00 pmClosed
Regional Engineer
Kerala State Nirmithi Kendra (KESNIK) Second floor ,Civil Station, Kottarakkara
this work consists of construction of supply installation testing and commissioning) of 8 mtr low mast lights with 4 nos of 100w led flood lights , interlock laying works, concrete road -127m padinjare vellamthetty-kizhakke vellamthetty
2026_KSNK_847880_1
KSNK/TECH/KTR/AGPVT-162/2026
Open Tender
Civil Works - Buildings
365 days
Vellamthetti, Pathanapuram, Kollamvv
As Per NIT
7 documents required · 7 mandatory
₹2,500
₹50,000
Yes
22 Jun 2026
18 Mar 2026
1 Apr 2026
18 Mar 2026
30 Mar 2026
18 Mar 2026
18 Mar 2026 - 30 Mar 2026
1) SITC (Supply Installation Testing and Commissioning) OF 8 Mtr LOW MAST LIGHTS WITH 4 Nos OF 100W LED FLOOD LIGHTS NEAR ANGANWADI JUNCTION - ELECTRICAL WORKS
90.15.1.1 Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
90.15.4.7 Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.14.1.2 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2 Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD283174/2025-2026 Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable.
OD283177/2025-2026 Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable.
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.10.3 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
5.3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.16.4.2 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
9.1.2 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
OD283175/2025-2026 Supplying, installing, testing and commissioning of wall mounted Single phase 2 wire energy meter with Meter box poly carbonate body having range of 32 Amp with enclosure made out of powder coated 16 SWG sheet suitable for fixing in surface/ recess with fuse unit 32 amp with neutral link, its interconnection etc. The enclosure shall have lockable door with glass window and all mounting accessories etc. complete as required Including all laison works & KSEB Charges.
OD283176/2025-2026 Deposit for KSEB Post for bringing electric connection to Low mast pole.
1) SITC (Supply Installation Testing and Commissioning) OF 8 Mtr LOW MAST LIGHTS WITH 4 Nos OF 100W LED FLOOD LIGHTS NEAR ANGANWADI JUNCTION - CIVIL WORKS
2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD283179/2025-2026 Supply and fixing Name Board of Project, with Angles ,Flats, Square Pipe, ACP Sheet (complete 4 sides) including Nut and bolt etc complete. As per the directions of Engineer-In-Charge
2) ANGANWADI - INTERLOCK LAYING WORKS
2.1.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
51.2.3 Filling with Quarry Muck <br> Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
3) CONCRETE ROAD -127m PADINJARE VELLAMTHETTY-KIZHAKKE VELLAMTHETTY (NEAR GURUMANDIRAM)
2.1.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
16.78.3 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.1.2 Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
4) SUPPLY OF PLASTIC CHAIRS AT VELLAMTHETTY NAGAR
OD283921/2025-2026 High-quality virgin plastic chair ,build for lasting durability. Ergonomic design ensuring prolonged sitting comfort. Vibrant colours having a cheerful and attractive appeal. Glossy finish on the chair adds an appealing touch . Easy to clean (Branded items).As per the directions of Engineer-In-Charge
5) DR RETAINING WALL OF STREAM AT VELLAMTHETTY NAGAR
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
4.3.2 Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
6) RCC CULVERT NEAR ANGANWADI
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.9.6 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.2.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.2.1 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)
13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats
7) WATER TANK -18 HOUSES
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.08 MB
tenderconditions.pdf
Tender Documents • 0.64 MB
epaymentform.pdf
Other Document • 0.01 MB
agreement.pdf
Additional Documents • 0.29 MB
BOQ_1433012.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid