Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.9 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | ₹18.9 L Quoted ₹21.7 L | L-1 | Accepted-AOC L1 |
| 2 | L-2₹22.9 L+₹1.1 L (5.28%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | ₹22.9 L+₹1.1 L (5.28%) | L-2 | Rejected-AOC L2 |
| 3 | L-3₹27.6 L+₹5.9 L (27.2%)Rejected-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹27.6 L+₹5.9 L (27.2%) | L-3 | Rejected-AOC L3 |
| 4 | L-4₹29.9 L+₹8.2 L (37.8%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹29.9 L+₹8.2 L (37.8%) | L-4 | Rejected-AOC L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical No slow progress show cause notice served |
| Sl No | Description | Qty | Unit | Shiv Enterprises L3 | Pradeep Bros L1 | SNOWY ENGINEERING INC L2 | M/S ADHIKARI CONSTRUCTION CO. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Dehydration and Filteration of 11 KV grade Transformer oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achieving the dielectric strength to 40 KV for 1 minute with a sphere gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any KVA transformer etc as specified and directed by Engr in charge. Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | 2,500 | Ltr | 10 ₹25,000 | 10 ₹25,000 | 12 ₹30,000 | 9.99 ₹24,975 Lowest |
| 2.00 | M&L for Taking out HT OCB/VCB/RMU,11 KV grade 400 Amps rating from HT panel for servicing / repairs by dismantling the HT OCB operating mechanism, inspection of control wiring realignment of moving contacts with fixed contacts assy, vaccum interrupter ,checking of relays for protection, greasing of all moving parts of mechanis, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB , fixed in its original position , testing for functions, and commissioning complete all as directed by Engr in charge. | 8 | Each job | 3,000 ₹24,000 | 2,000 ₹16,000 Lowest | 3,985 ₹31,880 | 4,999 ₹39,992 |
| 3.00 | M&L for Supply and fixing of push button suitable for 400 amps OCB complete all as specified and directed. | 2 | Each | 100 ₹200 | 50 ₹100 Lowest | 75 ₹150 | 499 ₹998 |
| 4.00 | M&L for Calibration of 11 KV grade HT OCB/VCB relays of various types / Make by OEM through primary & Secondary injection method by bringing relay test kit, software PC system and other required measuring equipments to the site, after testing refixing to OCB 11 KV panel all as directed by Engr-in-Charge. Note- Certificate of this test will be provided by the contractor free of cost. | 13 | Each Job | 2,000 ₹26,000 | 2,000 ₹26,000 | 700 ₹9,100 Lowest | 1,999 ₹25,987 |
| 5.00 | Testing of HT current transformer (set of three) through primary current injection method and also checking the connected panel wiring by brining required test kit and other required testing equipment and also checking tripping and closing operation complete all as directed by Engr-in-Charge. | 8 | Each Job | 1,000 ₹8,000 | 500 ₹4,000 Lowest | 950 ₹7,600 | 1,999 ₹15,992 |
| 6.00 | Supply, install, test, commissioning of 11 KV grade HT OCB/VCB/RMU current transformer in repair CT of 11 KV grade with CT ratio 300/150/5-5 fixed with HT OCB/VCB/RMU 11 KV including necessary cable connection etc suitable for fixing in HT panel board of any make including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as specified and directed. | 8 | Each | 5,000 ₹40,000 | 12,000 ₹96,000 | 6,878 ₹55,024 | 1,999 ₹15,992 Lowest |
| 7.00 | M & L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in OCBs 11 KV feeders checking of control wiring meters, relay and tripping system complete all as directed by Engr-in-Charge. | 1 | Each Job | 1,000 ₹1,000 | 1,500 ₹1,500 | 849 ₹849 Lowest | 4,999 ₹4,999 |
| 8.00 | S & F in repair Potential Transformer for HT OCB 11/110 volts/3, 100 VA resincast epoxy moulded with metal enclosure as per site requirement and connecting bus bar including providing bus bar, testing for functionality complete all as directed by Engr-in-Charge. | 1 | Each set | 15,000 ₹15,000 | 18,000 ₹18,000 | 7,930 ₹7,930 | 4,999 ₹4,999 Lowest |
| 9.00 | Supply and fixing in repair HT Voltmeter, range 0 to 15 KV auxillary supply 110 Volts suitable for fixing with existing HT OCB 11 KV panel complete all as directed by Engr-in-Charge. | 1 | Each | 1,000 ₹1,000 | 1,500 ₹1,500 | 950 ₹950 Lowest | 4,999 ₹4,999 |
| 10.00 | Supply and fixing in repair ammeter suitable for fixing with existing HT OCB 11 KV panel ratio like 300/5,200/5,100/5 complete all as directed by Engr-in-Charge. | 1 | Each | 1,000 ₹1,000 | 1,500 ₹1,500 | 800 ₹800 Lowest | 4,999 ₹4,999 |
Tender Value
₹35.0 L
EMD Value
₹70,000
Closing Date
19 Feb 2026, 6:00 pmClosed
GE I RnD Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
REPAIR MAINT OF EXTERNAL ELECTRIFICATION TRANSFORMER VCB LT PANELS LT UG CABLE AND ALLIED WORKS IN DIPAS DIPR CFEES AND RAC OF KWC AREA UNDER GE I RnD DELHI
2026_MES_750208_1
GE/RND/T-82/DLI/2025-2026
Open Tender
Civil Works
Item Rate
240 days
Delhi
As per tender documents
2 documents required · 2 mandatory
₹500
GE I RnD Delhi
₹70,000
21 Apr 2026
28 Jan 2026
21 Feb 2026
28 Jan 2026
19 Feb 2026
12 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Dehydration and Filteration of 11 KV grade Transformer oil through stream line filteration plant for extracting moisture content in the oil and carbon deposits and achieving the dielectric strength to 40 KV for 1 minute with a sphere gap of 2.5 mm and also checking the acidity of oil with acidity test kit and submitting the necessary test kit report /certificate, refilling the filtered oil into any KVA transformer etc as specified and directed by Engr in charge. Note: The filtration includes taking necessary connection to filtration plant from the transformer to their hose pipe by opening the inlet and outlet of transformers and closing the same after filtration. | 2,500 | Ltr | - | - |
| 2 | M&L for Taking out HT OCB/VCB/RMU,11 KV grade 400 Amps rating from HT panel for servicing / repairs by dismantling the HT OCB operating mechanism, inspection of control wiring realignment of moving contacts with fixed contacts assy, vaccum interrupter ,checking of relays for protection, greasing of all moving parts of mechanis, checking and realignment of mechanism for its proper functioning and operation, re-assembling of HT VCB , fixed in its original position , testing for functions, and commissioning complete all as directed by Engr in charge. | 8 | Each job | - | - |
| 3 | M&L for Supply and fixing of push button suitable for 400 amps OCB complete all as specified and directed. | 2 | Each | - | - |
| 4 | M&L for Calibration of 11 KV grade HT OCB/VCB relays of various types / Make by OEM through primary & Secondary injection method by bringing relay test kit, software PC system and other required measuring equipments to the site, after testing refixing to OCB 11 KV panel all as directed by Engr-in-Charge. Note- Certificate of this test will be provided by the contractor free of cost. | 13 | Each Job | - | - |
| 5 | Testing of HT current transformer (set of three) through primary current injection method and also checking the connected panel wiring by brining required test kit and other required testing equipment and also checking tripping and closing operation complete all as directed by Engr-in-Charge. | 8 | Each Job | - | - |
| 6 | Supply, install, test, commissioning of 11 KV grade HT OCB/VCB/RMU current transformer in repair CT of 11 KV grade with CT ratio 300/150/5-5 fixed with HT OCB/VCB/RMU 11 KV including necessary cable connection etc suitable for fixing in HT panel board of any make including modification required at site to be carried to fix CT upto recess/coils including removing the burnt CTs complete all as specified and directed. | 8 | Each | - | - |
| 7 | M & L for checking of Potential Transformer by conducting ratio test/meggering for IR values, provided in OCBs 11 KV feeders checking of control wiring meters, relay and tripping system complete all as directed by Engr-in-Charge. | 1 | Each Job | - | - |
| 8 | S & F in repair Potential Transformer for HT OCB 11/110 volts/3, 100 VA resincast epoxy moulded with metal enclosure as per site requirement and connecting bus bar including providing bus bar, testing for functionality complete all as directed by Engr-in-Charge. | 1 | Each set | - | - |
| 9 | Supply and fixing in repair HT Voltmeter, range 0 to 15 KV auxillary supply 110 Volts suitable for fixing with existing HT OCB 11 KV panel complete all as directed by Engr-in-Charge. | 1 | Each | - | - |
| 10 | Supply and fixing in repair ammeter suitable for fixing with existing HT OCB 11 KV panel ratio like 300/5,200/5,100/5 complete all as directed by Engr-in-Charge. | 1 | Each | - | - |
stage.html
html • 0.05 MB
technical_840252.pdf
techsummary_840252.pdf
finance_840252.pdf
BOQ Comparative Chart
xlsx
finsummary_840252.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
TDR.pdf
Tender Documents • 1.36 MB
BOQ_840252.xls
BOQ • 1.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .