Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC NOT SPECIFIED | ₹23.1 L Quoted ₹29.2 L | L1 | Accepted-AOC AWARD |
| 2 | L2₹34.2 L+₹5.0 L (17.2%)Rejected-Finance | ₹34.2 L+₹5.0 L (17.2%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | Rejected-Technical BLOCK NO 1 VPO BUDAIN TEHSIL UCHANA DISTT JIND | JIND | HARYANA | - | - | Rejected-Technical Proof of Immovable Properties, Cancelled Cheque, Applicant/Employee Diploma Holder self Declaration with Copy of Diploma Certificate not attached |
| Sl No | Description | Qty | Unit | RAM PHAL SINGH CONT L2 | ALTOZ AUTOMATION L1 |
|---|---|---|---|---|---|
| 1.00 | Online multi::parametric COD, BOD, TSS and pH Analyzer With GPRS data transmission to CPCB/SPCB portal Supplied with Spectrophotometry Sensor (COD, BOD, TSS), pH::lyser (pH) and con::cube terminal
Make: S::CAN, AUSTRIA | 1 | Each | 16,00,000 ₹16,00,000 | 14,00,000 ₹14,00,000 Lowest |
| 2.00 | Electromagnetic Flow Meter upto 20 inch
Make: Badger/ABB
Description
Product Type: 1M - M1000
Certification: A - GENERAL SAFETY/PURPOSE
Meter Size: 180 - 18` / DN450
Process Connections: FAA - ASME: CLASS 150 FLG: RF
Base Material: C1 - CARBON STEEL
Liner Material: P - PTFE
Electrodes : A - Hastelloy C-22 (Standard / Measuring,
Empty pipe and Grounding)
Grounding rings: X - NO GND RINGS
Meter Lay Length: S - STANDARD
Transmitter: SA - SENSOR MOUNT: LOCAL DSP: AL
ENCL: IP67
Power Supply: AB - 9-36V DC
Hardware: C - M20 THRD: POLY CABLE GLANDS
Junction Box: X - NONE
Remote Cable Length: WW - NONE
Input/Output Channel: DBA - STD INPUT/OUTPUT
Communications: R - STD COMMS
Wiring Method: XX - NONE STD
Programming: EA - Standard (Default Metric units)
Testing and Tagging: F - 0,3%: 3-POINT: FACTORY
CALIBRATED | 1 | Each | 6,00,000 ₹6,00,000 | 5,50,000 ₹5,50,000 Lowest |
| 3.00 | Operation and Maintenance during defect cum liability period | 12 | Per Month | 15,000 ₹1,80,000 | 12,000 ₹1,44,000 Lowest |
| 4.00 | Operation and Maintenance for First Year after defect cum liability period | 12 | Per Month | 15,000 ₹1,80,000 | 12,000 ₹1,44,000 Lowest |
| 5.00 | Operation and Maintenance for Second Year after defect cum liability period | 12 | Per Month | 15,000 ₹1,80,000 | 12,000 ₹1,44,000 Lowest |
| 6.00 | Operation and Maintenance for Third Year after defect cum liability period | 12 | Per Month | 19,000 ₹2,28,000 | 15,000 ₹1,80,000 Lowest |
| 7.00 | Operation and Maintenance for Fourth Year after defect cum liability period | 12 | Per Month | 19,000 ₹2,28,000 | 15,000 ₹1,80,000 Lowest |
| 8.00 | Operation and Maintenance for Fifth Year after defect cum liability period | 12 | Per Month | 19,000 ₹2,28,000 | 15,000 ₹1,80,000 Lowest |
Tender Value
₹16.3 L
EMD Value
₹32,664
Closing Date
18 Jun 2026, 11:00 amClosed
GAUTAM KUMAR
Sonipat PHED No. 2
Providing and Fixing of inlet effluent monitoring system for data transfer to PHED HSPCB and CPCB and server 2 No of UV flow meter at Inlet and Byepass of STP as per guideline of Haryana State Pollution control Board and monitoring of 7 MLD
2026_HRY_528389_1
202648451547 410C 4886 A896 EAD8EABE6F9F587PUH
Open Tender
Civil Works
Works
60 days
Ganaur
2 documents required · 2 mandatory
₹1,000
₹32,664
Yes
7 Aug 2026
11 Jun 2026
18 Jun 2026
11 Jun 2026
18 Jun 2026
11 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Online multi::parametric COD, BOD, TSS and pH Analyzer With GPRS data transmission to CPCB/SPCB portal Supplied with Spectrophotometry Sensor (COD, BOD, TSS), pH::lyser (pH) and con::cube terminal
Make: S::CAN, AUSTRIA | 1 | Each | - | - |
| 2 | Electromagnetic Flow Meter upto 20 inch
Make: Badger/ABB
Description
Product Type: 1M - M1000
Certification: A - GENERAL SAFETY/PURPOSE
Meter Size: 180 - 18` / DN450
Process Connections: FAA - ASME: CLASS 150 FLG: RF
Base Material: C1 - CARBON STEEL
Liner Material: P - PTFE
Electrodes : A - Hastelloy C-22 (Standard / Measuring,
Empty pipe and Grounding)
Grounding rings: X - NO GND RINGS
Meter Lay Length: S - STANDARD
Transmitter: SA - SENSOR MOUNT: LOCAL DSP: AL
ENCL: IP67
Power Supply: AB - 9-36V DC
Hardware: C - M20 THRD: POLY CABLE GLANDS
Junction Box: X - NONE
Remote Cable Length: WW - NONE
Input/Output Channel: DBA - STD INPUT/OUTPUT
Communications: R - STD COMMS
Wiring Method: XX - NONE STD
Programming: EA - Standard (Default Metric units)
Testing and Tagging: F - 0,3%: 3-POINT: FACTORY
CALIBRATED | 1 | Each | - | - |
| 3 | Operation and Maintenance during defect cum liability period | 12 | Per Month | - | - |
| 4 | Operation and Maintenance for First Year after defect cum liability period | 12 | Per Month | - | - |
| 5 | Operation and Maintenance for Second Year after defect cum liability period | 12 | Per Month | - | - |
| 6 | Operation and Maintenance for Third Year after defect cum liability period | 12 | Per Month | - | - |
| 7 | Operation and Maintenance for Fourth Year after defect cum liability period | 12 | Per Month | - | - |
| 8 | Operation and Maintenance for Fifth Year after defect cum liability period | 12 | Per Month | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
BOQ_607392.xls
BOQ • 0.26 MB
6H3QYDZ163033.pdf
Additional Documents • 15.11 MB
OT0163033.pdf
Other Document • 1.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .