Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.6 L+₹78,429 (5.30%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹17.8 L+₹3.1 L (20.7%)Rejected-Finance 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹18.2 L+₹3.5 L (23.4%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹19.4 L+₹4.6 L (31.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Jan 2022, 6:00 pmClosed
GE UTILITY
GE UTILITY AMBALA CANTT 133001
CLEANING MAINT OF SEWAGE LINES MANHOLES AND CONNECTED WORK IN SECTOR B UNDER GE UTILITY AMBALA CANTT
2021_MES_492548_1
CA NO GE U AMB 52 OF 2021 22
Open Tender
Civil Works
Item Rate
270 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹40,000
Yes
11 Jan 2022
4 Dec 2021
5 Jan 2022
4 Dec 2021
3 Jan 2022
18 Dec 2021
4 Dec 2021 - 11 Dec 2021
Amount
Cleaning of under ground existing SGSW/RCC/HDPE any dia of pipes line up to 1.50 mtr depth including manholes of any size working/running conditions and to remove blockage of sewage lines and manholes by steel/bamboo rodding including desludging, descaling and dechoking of lines whereever required, flushing the entire stretch with water making the stretch clean and funtional. Removal & depositing any type of sludge/debries to excavated area, spreading necessary Insecticides where sludge is deposited all as specified and directed by Engr in-charge. Note:- (i) All sludge/debries should be deposited in nearest pit & cover with sand & necessary disinfection be carried out removing/depositing of sludge/debries exc 500 mtr beyond the site & covering the entire sludge & solids with local earth. (ii) The cost of said provision shall be included in the rate quoted by the Contractor.
Description all as per serial item No. 1 here-in-before but depth of line exc 1.50 m and n. exc 3.0m
Description all as per serial item No. 1 here-in-before but depth of line exc 3.0 m and above. Note: For item No 1 to 3 (i) (During the cleaning of sewage lines/manholes contractor should have kept stand by non clog pump/motor with sufficient capacity and cable as directed by Engr-in-Charge at their own cost without extra payment from Deptt. (ii) The cost of said provision shall be included in the rate quoted by the Contractor.
Cleaning of under ground existing SGSW/RCC/HDPE any dia of pipes line and depth exc 3.0 mtr and above including manholes of any size working/running conditions including removal of blockages any kind of sewage lines and manholes by mechanical equipments and desludging, descaling and dechoking of lines whereever required, flushing the entire stretch with water making the stretch clean and funtional. Removal & depositing any type of sludge/debries in to excavated area, spreading necessary Insecticides where sludge is deposited all as specified and directed by Engr-in-Charge. Note:- (i) (All sludge/debries should be deposited in nearest pit & cover with sand & necessary disinfection be carried out OR Removing/depositing of sludge/debries exc 500 mtr beyond the periphery of defence land & covering the entire sludge & solids with local earth). (ii) Contractor must have appropriate machine with suitable staff. (iii) The quoted rates shall be included the said provisions.
Demolition of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc., complete all as specified.
Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) remove and spread in low lying area al directed by Engr-in-Charge n exc. to 250 m distance complete all as specified and as directed by Engineer-in-Charge.
Demolition of concrete of any description and in any position not otherwise specifically provided for cement concrete (reinforced) remove and spread in low lying area al directed by Engr-in-Charge n exc. to 250 m distance complete all as specified and as directed by Engineer-in-Charge. (Reinforcement cut as required to facilitate demolition)
Excavation in trenches not exc 1.5 m deep & not execeding 1.5m wide for foundation or shaft, wells, cesspits, manholes, pier holes etc n.exc 10sqm on plan and n.exc 1.5mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Desciption all as per serial item No. 8 here in before but 1.5m deep & not exc 3.00m deep
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil all as specified and directed.
Description all as per item No 10 here in before but exc. 1.5 mtr and not exc.3.00 mtr deep. Notes for Ser Item No. 8 to 11 (i) Bailing and Pumping out of water where required shall be carried out as per clause 3.17 & 3.18 of SSR (Part-II) of 2020. (ii) Timbering, planking and strutting if required shall be carried out as per clause 3.24, 3.24.1 & 3.24.6 of SSR (Part-I) of 2009. (iii) The rates quoted by contractor shall deemed to be included for above provisions. Nothing extra shall be paid on this account.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 150 mm and thrown in low lying area n, exc. 250 m distance as directed by Engr-in-Charge.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 200 mm and thrown in low lying area n, exc. 250 m distance as directed by Engr-in-Charge.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) concrete bed to 150mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) concrete bed to 200mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested.
M&L DWC (Double wall corrugated) HDPE pipes of size 150mm (ID dia ) confirming to IS -16098 Part-II of strength/stiffness class SN 8 laid in trenches on conrete bed to level/gradient, jointing as per manufacturers instructions including jointing accessories as required complete all as specified & directed by Engr-in-Charge.
M&L DWC(Double wall corrugated) HDPE pipes of size 200mm (ID dia ) confirming to IS -16098 Part-II of strength/stiffness class SN 8 laid in trenches on conrete bed to level/gradient , jointing as per manufacturers instructions including jointing accessories as required complete all as specified as directed by Engr-in-Charge.
Returning, filling in foundation/trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil/materials to a distance exceeding 100 Mtr and depositing where directed at a level not exceeding 1.5 Mtr from the starting point, complete all as specified and as directed by Engineer-in-Charge.
M&L PCC in surface channels,benching in sewers,drains etc type B1 (1:2:4) using 20 mm graded crushed stone aggregate complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter (Flat rough finished). complete all as specified and directed.
Use and waste form work to faces of walls, retaining walls, RCC circular manholes, parapets, rough, finish surfaces of manholes etc. all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flatall as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizintal or sloping & similar work exc 10cm but n exc 20cm wide Roughed finished surface of concrete all as specified and directed by Engr-in-Charge.
S & F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips. complete all as specified and directed.
Description all as per srl item No 26 here-in before but 8 mm dia.
M & L RCC M-30 design mix (using 20 mm graded crushed stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete
M&L reinforced cement concrete M-30, (design mix) (20 mm graded crushed stoneaggregates) in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified.
M&L RCC M-30 design mix (using 20 mm graded crushed stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Cutting existing road of premix carpet, WBM and hardcore complete and make good with PCC 1:2:4 type B-1 after laying of pipe complete all as specified and directed by Engr-in-Charge.
S&F mild steel rungs as in steps of manhole confirming to Fe-290 GDE E- 165 complete all as specified and as directed.
S&F manhole cover SFRC factory made of size 560 mm dia with steel frame heavy duty all as specified
M & L rubber moulded precast concrete interlocking paver block (50% grey and 50% coloured) any shape and size of 60 mm thickness, M-35 Grade with grey cement and pigment over and including 50 mm sand cushion all as directed.
Material and labour 75mm thick cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in floor, finishing cement concrete surface complete laid in alternate bays, making impressions of expended metal while the concrete is green all as specified and directed by Engr-in-charge..
M&L brick work with sub class ’B’ brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1 :4 complete all as specified and directed by Engr-in Charge. (Raising & Manholes)
M&L 15 mm thick rendering in cement mortor 1:4 with water proofing compound (2% by weight of cement) finished even and smooth without using extra cement on fair faces of brick work or concrete surfaces. (Note- WPC shall be measured and paid separetely)
Supply only water proofing compound.
Cleaning and removing of blockage from Manholes of any size and upto 2.0m depth incl removing the soil, roots or any other materials from the manholes working/running conditions and flushing the entire stretch with water making the stretch clean and funtional including removal & depositing any type of sludge/debries to excavated area, spreading necessary Insecticides where sludge is deposited all as specified and directed by Engr in-charge.
Cutting into existing manholes, for connecting new drain pipe/bend/Tee upto 150 mm bore pipe and making good to pipe or wall leak proof and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) manholes and filling cut of walls by cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate smooth finish and reforming benching, complete all as specified and as directed.
Cutting into existing manholes, for connecting new drain pipe/bend/Tee of 200 mm bore pipe and making good to pipe or wall leak proof and rendering cutting out existing benching for and forming branch channels (1/2 round or 3/4 section) manholes and filling cut of walls by cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) smooth finish and reforming benching, complete all as specified and as directed.
M & L providing cement concrete (1:2:4) type B1 (20 mm graded crushed stone aggregate) in lintels upto 1.5 m clear span, up to 60 cm in height, copings, benching, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
M & L pre-cast cement concrete 1:1.5:3 type B-1 (using 20mm graded crushed stone aggregate) as in man hole cover, with plain fair faces including necessary form work complete all as specified and as directed by Engr-in-Charge.
Note:- Amount of credit of Rs. 8750.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
M/S M S BUILDER AND CONTRACTORS
Puneet Sharma
s.v.builders
JMB BUILDERS & ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .