Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC AWARDED DUE TO L1 | |
| 2 | L2₹33.5 L+₹76,325 (2.33%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹34.6 L+₹1.9 L (5.89%)Rejected-Finance 10 SUBASH COLONY DEFENCE LAB ROAD RATANDA JODHPUR 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance Rejected due to L3 | |
| 4 | L4₹38.9 L+₹6.2 L (19.0%)Rejected-Finance 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | L4 | Rejected-Finance Rejected due to L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to not uploaded relevant documents as per NIT conditions |
Tender Value
Refer Docs
EMD Value
₹82,000
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SHIKARGARH
Military Engineer Services, Garrison Engineer, Shikargarh, Near ASC Supply Depot, Ratanada Jodhpur-342011
SPL REPAIR TO AIR COOLING SYSTEMS OF WARDS AT MILITARY HOSPITAL JODHPUR UNDER GE SHIKARGARH
2022_MES_526501_1
8760/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SHIKARGARH JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE SHIKARGARH
₹82,000
Yes
2 Aug 2022
21 Jun 2022
21 Jul 2022
21 Jun 2022
19 Jul 2022
5 Jul 2022
21 Jun 2022 - 27 Jun 2022
60 days
Amount
Supply, installation, testing and commissioning of air cooling system with floor mounted high static air cooling unit of following capacity and specification including dismantling of existing unit and depositing in MES E/M store yard at Shikargarh :-
High Static Air Cooling Unit Double Skin 7000 CFM shall be Floor Mounted Double Skin (Inner Panel Shall be made out of 0.6mm GI Plain and Outer Panel shall be 0.6mm thick powder coated GI with 25 mm Thick Puff Insulation having density of 40 Kg / Cu.M) giving 90% efficiency at 500 FPM air velocity across the pads with Tank Made out of 18 Guage Stainless Steel of capacity not less than 200 Ltr,Cellulose Pad of 300 mm thick, pad area 14 Sqft, having Pre filters of aluminium wire mesh and filter frame made of GI sheet. The filter shall have 90% down to 10 microns filtration efficiency. BLOWER DIDW Forward Curved, suitable size Centrifugal blower Fan Heavy Duty having Forward Curved Impeller, Water Re-circulation Pump shall be of 0.5 HP of Monobloc type, 3 HP Motor shall be suitable for 415V, 50 cycles, AC power supply with IP 55 protection for enclosure incl suitable size of DOL starter with enclosure for 3 ph motor, DIDW (Double Inlet Double Width) Made out of 16 Guage GI enclosed in suitable housing and mounted on EN 8 Shaft duly dynamically and statically balanced.
All as per Srl No 1.01 above but 5000 CFM, water tank not less than capacity 150 Ltr, Cellulose Pad area 10 Sqft & 3 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 9000 CFM, water tank not less than capacity 250 Ltr, Cellulose Pad area 18 Sqft & 7.5 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 8000 CFM, water tank not less than capacity 200 Ltr, Cellulose Pad area 16 Sqft & 5 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 10000 CFM, water tank not less than capacity 250 ltr, Cellulose Pad area 20 Sqft & 7.5 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 16000 CFM, water tank not less than capacity 350 ltr, Cellulose Pad area 32 Sqft & 10 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 6000 CFM, water tank not less than capacity 150 ltr, Cellulose Pad area 12 Sqft & 5 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 4000 CFM, water tank not less than capacity 150 ltr, Cellulose Pad area 8 Sqft & 3 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 12000 CFM, water tank not less than capacity 300 ltr, Cellulose Pad area 24 Sqft & 7.5 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
All as per Srl No 1.01 above but 14000 CFM, water tank not less than capacity 350 ltr, Cellulose Pad area 28 Sqft & 10 HP Motor incl suitable size of DOL starter with enclosure for 3 ph motor
Notes for Item Nos 1.01 to 1.10 :- (i) Cabinet Make - Evapoler ECO COOLING SOLUTION -JAIPUR / ZECO-Jaipur /Cool Air System (CAIR) - Delhi or equivalent as approved by GE. (ii) Make of monoblock water pump –Kirloskar / Crompton / KSB (iii) Blower Fan Make – NICOTRA / KRUGER / BLOWTECH (iv) Blower Motor Make – ABB / BHARAT BIJLEE / HAVELLS / CROMPTON / MARATHON / SEIMENS (v) Necessary T&P required for shifting / Installation on Terrace (G+3) of Military Hospital and Taking down of existing Air cooling system to be dismantled and deposit to MES E/M yard situated at approx 10 to 11 Km away at Shikargarh shall be included in the item rate quoted by contractor. (vi) Necessary civil work like plastering / PCC and anti vibration pad will also included on the quoted rates. (vi) During installation of news systems / dismantling of existing Air cooling system, if any damage occur in the MH bldg, the shall be repaired by the Contractor at his own.
Supply and fixing Complete Canvas Clothes (Zip arrangement) with S/S body frame of suitable size of any description as per existing and directed by Engr-in-Charge
Supply, Installation & testing of Galvanised Sheet FABRICATED DUCT as required at site with Connectors, GI Flanges, turning vanes, with proper duct sealing etc with RTV duct Sealant, Complete as reqd at site as per the specifications :-
(a) 20 Gauge- FABRICATED Duct
(b) 22 Gauge- FABRICATED Duct
(c) 24 Gauge- FABRICATED Duct
Supply & fixing of 12mm thick of Aluminium Coated Nitrile rubber insulation for Galvanised Sheet Fabricated Duct complete all as directed by Engr-in-Charge.
Supply & fixing of adjustable type supply air diffuser of size 12 x 12 inch, made by aluminium fabricated in various wards duct complete all as directed by Engr-in-Charge.
M&L for sub main wiring with 3 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 1 run 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from DB to starter, complete all as directed. Note : Three run of 4 Sq.mm and one run of 4 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. Make of wire : Finolex/Havells/KEI/Polycab, Make of PVC conduit : Finolex/Modi/Polycab.
All as per Srl item No 6 but 10 Sqmm
All as per Srl item No 6 but 16 Sqmm
Supply and lay 25 mm bore galvanised steel tubing medium grade with all fittings and fixtures laid in trench or ceiling or laying in floors complete all as directed.
SANJOLI CONSTRUCTION COMPANY
Panwar Electricals
Shree Karni Electrovision
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .