Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC H NO 1566 2 SECTOR 30 B CHANDIGARH | NA | NA | 160001 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹16.3 L+₹47,769 (3.02%)Rejected-AOC SPRINGDALE MARKET SEC 123 SUNNY ENCLAVE MOHALI 140301 | MOHALI | S A S NAGAR | PUNJAB | 140301 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹17.9 L+₹2.0 L (12.9%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹17.9 L+₹2.1 L (13.0%)Rejected-AOC FLAT NO 203 GH 5 SECTOR 27 PANCHKULA 134116 HRY | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC Quoted L4 | |
| 5 | L5₹18.0 L+₹2.2 L (13.6%)Rejected-AOC | L5 | Rejected-AOC Quoted L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Jun 2023, 6:00 pmClosed
GE AF Chandigarh
GE AF Chandigarh PIN-160003 C/o 56APO
REPAIRS TO BOUNDARY WALL, GATE, COURTYARD AND PATH AT SECTOR 28, 31 AND 47 AT CHANDIGARH UNDER GE (AF) CHANDIGARH
2023_MES_594759_2
GE(AF)/CHD/T-08/2023-24
Open Tender
Civil Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE AF Chandigarh
₹40,000
Yes
30 Aug 2023
6 Jun 2023
3 Jul 2023
6 Jun 2023
27 Jun 2023
13 Jun 2023
6 Jun 2023 - 9 Jun 2023
Amount
Demolition of brick masonry built in cement mortar including all quoins/ arches/ pillars etc. but excluding ashlars facings, dressed stone work, precast concrete articles and disposing off the rubbish debris to distance exc. 1.50 KM and n. exc. 3.00 KM complete all as specified and directed.
M&L for brick work straight or curved on plan exceeding 6 metre mean radius using old size sub class 'B' burnt bricks built in cement mortar (1:6) complete all as specified and directed.
All as per item No. 2.00 above but except bricks. Note: Old re-usable bricks retrieved vide item No. 1.00 above shall be re-used after cleaning etc. and quoted rate shall be deemed to include for the same.
M&L providing precast cement concrete louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame in cement concrete (1:2:4) type B-0 (using 12.5 graded stone aggregate) set in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc. including racking out of joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for keyed pointing in cement mortar (1:4) in walls or to brick on edge in floors, surface channels, roofs, etc. complete all as specified and directed.
M&L for keyed pointing in cement mortar (1:4) including raking out joints/ pointing from brick work in walls or to brick on edge in floors, surface channels, roofs, etc. complete all as specified and directed.
Demolition of reinforced cement concrete of any description & in any position (below or above ground level), not exceeding 15cm thickness, including removal of rubbish to a place as approved by civic body complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for providing RCC (1:1½:3) type A-1 using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under reamed piles and mass concrete complete all as specified and directed.
Use and waste of formwork to foundations, footings, bases of columns, rafts & raft beams, sides & soffits of foundation & plinth beams and similar works; vertical or batter for rough finished surface of concrete complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, kitchen shelves etc. (laid, bedded and pointed in any mortar) complete all as directed and specified.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigments (in top layer) laid as per manufacturer's instructions complete all as specified and directed.
M&L sand filling under floors or in foundation including watering, well ramming & consolidating in layers not exceeding 25cm thick complete all as specified and directed.
M&L for coloured chequered cement concrete tiles of size 30cm x 30cm x 25mm/ 40cm x 40cm x 25mm thick, factory made with grey cement and pigment; set, jointed and pointed in neat cement slurry and pointed with white cement and pigment as in floors laid over and including 20mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floors complete all as specified and directed.
M&L cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in roof kerbs or mud stops, sides of interlocking paver blocks and similar works complete all as specified and directed.
M&L 75mm thick PCC (1:3:6) type C-2 using 40mm stone graded aggregate as in floors/ hardstanding/ plinth protection laid in panels including filling of joints by bitumen and sand in ratio (1:2) complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position (below or above ground level) not exceeding 15cm thick including removal of rubbish to a place as approved by civic body complete all as specified and directed.
M&L for taking down hanging mild steel gate not exceeding 1.50 Sqm each and refixing in the same opening after carrying out necessary repair work with welding such as change of rusted hold fast, hinging device, pintol, pivotel and locking arrangement, PCC of hold fast etc. complete all as specified and directed.
Dismantling structural steel work as in doors, gates etc. all as specified and directed.
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
M&L cutting holes in brick/ stone walls built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar (1:3) or cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate for the required depth of embedded portion of holdfasts or lugs measured from the face of jamb into the wall n. exc. half brick including making good complete all as specified and directed.
M&L preparation of newly plastered or previously untreated surface of walls and applying two coats of cement base paint complete all as specified and directed.
M&L preparation of old treated surface of walls and applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.
Dismantling plain or corrugated steel/ fibre sheeting any gauge and thickness including Nainital or similar pattern roof covering all as specified and directed.
S&F Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength 550Mpa as in roof covering fixed with self tapping screws as per manufacturer’s instruction complete all as specified and directed.
S&F fibre glass reinforced translucent corrugated sheeting 2mm thick fixed with coach screws and washers with two corrugations side lap as in roof, wall etc. complete all as specified and directed.
S&F rolled mild steel roof trusses (framed), trussed purlins, posts, rafters, crane gantries, rails & fastenings & heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Gde Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over one coat of red oxide primer on new steel surface any description exc. 10cm width or girth including preparation of surface complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on steel or iron surfaces of any description over 10cm width or girth including preparation of old painted surfaces complete all as specified and directed.
M&L taking down rolling shutter and re-fixing the same in existing location after repairs including cleaning, welding, oiling, greasing etc. complete all as specified and directed.
M&L for preparation of old surfaces of floors/ tiles/ paver block/ chequered tiles etc. including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of terra cotta paint complete all as specified and directed.
Excavation in trenches in soft/ loose soil n. exc. 1.5m deep and n. exc. 1.5m wide for foundations, laying pipe line, cable etc. or n. exc. 10sqm on plan for shafts, wells, cesspits, manholes, pier holes etc. and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick with soils complete all as specified and directed.
Removing excavated soil n. exc. 50m and depositing where directed at a level n. exc. 1.50m above the starting point complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using mechanically crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
R R Traders
M/S MATLOOB AHMED
B N FRIENDS AND CO
M/S GOYAL ASSOCIATES
Baba Engineers and Contractors
M/S Bangali Ram
Harbhajan Singh Sandhu and Sons
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .