Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 869B INDIAN CENTRIFUGE ENGINEERING SOLUTIONS PRIVATE LIMITED ETTUMANOOR KOTTAYAM KOTTAYAM KERALA 686631 | KOTTAYAM | KERALA | 686631 | Admitted-Finance |
Tender Value
₹32.9 L
EMD Value
₹50,000
Closing Date
14 Oct 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer, Sabarimala Development Project, Travancore Devaswom Board, Pathanamthitta-689645
SDP-Nilakkal- MnM festivals in 1200 ME- Overhauling and operation of Incinerator Unit I and II including supply of spares and labour (New Incinerator)
2024_TDB_695675_1
SDP/EE/ET-104/24-25
Open Tender
Miscellaneous Works
Item Rate
90 days
Nilakkal
Refer NIT
4 documents required · 4 mandatory
₹2,950
₹50,000
16 Oct 2024
10 Oct 2024
15 Oct 2024
10 Oct 2024
14 Oct 2024
10 Oct 2024
Amount
Appendix A
Maintenance, repairing and complete overhauling of primary chamber. (2 set) Cleaning the refractory lined furnace walls, arch, Patch work to the refractory lining and insulation layer using fire create cement ,bricks etc , making good the refractory lined charging door and ash doors using castables, and ceramic wool. The rate also includes complete painting (2 coats) of primary chamber out surface using heat resistant aluminium paint.
Maintenance, repairing and complete overhauling of secondary chamber . (2 set)Cleaning the refractory lined furnace walls, arch, Patch work to the refractory lining and insulation layer using fire create cement ,bricks etc , making good the refractory lined ash doors using castables, and ceramic wool. The rate also includes complete painting (2 coats)of secondary chamber out surface using heat resistant aluminium paint.
Complete dismantling of mono -bloc burner assembly in primary and secondary chamber for the incinerators, cleaning of electrodes, solenoid valves, blower fans, transformer, burner rod, nozzle, photocell, sight glass, diffuser plate, cone etc., Reassembling and tuning of burner assembly for proper combustion of system.
Dismantling, overhauling, cleaning, and minor repair works to the FD fan assembly .The work includes complete cleaning of the impeller, motor, coupling and re assembling , and necessary patch work to the casing and painting .
Dismantling of horizontal refractory lined duct connecting the secondary chamber with ventury scrubber , removing the defective refractory layer form the duct, cleaning and re casting the duct using refractory cement (grade whytete/K). the work also includes providing necessary ‘Y’ type jagers inside the surface for strengthening the refractory lining.
Maintenance to the ventury scrubbing unit of each incinerator by dismantling all the water inlet connections from the unit, cleaning the spray nozzles, inside surface, damper mechanism, thermo well and re assembling the unit using new gaskets, nuts bolts etc. the defective gaskets, nuts bolts , .
Maintenance to the droplet separator unit of each Incinerator by dismantling the unit from the incinerator assembly , and de-ashing the same using suitable chemical solution, Re assembling the unit using new high quality gasket, nuts, bolts and painting using heat resistant hammer tone painting .The work includes repairing and cleaning of ‘U’ bend connecting the droplet separator with ID fan consumables.
Supply, fabrication and fixing of droplet separator having 800 mm dia, 2600 mm hight straight portion made of 6mm thick ms plate,800 x 375 conical portion having 340mm height made of 6mm ms plate, 8 mm thick bottom plate provision for fixing of vetury scrubber unit, scrubbing water pump inlet and outlet connection, U bend having 410mm dia made of 4mm MS sheet for connecting the droplet with ID fan suction duct, drain point, manhole etc. The rate inclusive of complete dismantling of existing droplet separator applying 2 coat hammer tone paint. transportation charges from work shop to Sabarimala, consumables like welding rod;cutting wheel LPG, packing, oxygen etc
Supply and installation of Centrifugal type Induced Draft fan , The specifications & scope of supply is as follows Fan casing and impeller made of Mild steel having Capacity 4750 M3/hr @ 450mm WC, The scope of supply inclusive of shaft, bearing bloc, bearings, bearing sleeve, Pulley, Belt and structural platform for mounting the fan casing fabricated using MS C channel, angle etc. The rate is also inclusive of charges for dismantling the existing ID fan from the foundation, making necessary modifications to the inlet/ outlet duct connections, installing the new ID fan assembly , transportation charges, loading charges etc
Labour charges for cleaning of fuel day tank, fuel lines, fuel filter , Rectification of leakages to the fuel line, valves, fuel pump, Replacement of gland packing, gaskets, oil seal for both the incinerators .
Labour charges for checking and necessary repairs of control panel board and related parts of Incinerator ensuring perfect and trouble free operation of all switches, contactors, OLR, MCBs, fuses, sequence controller, temperature controller, RTD, thermocouple, motors, photocell, visual and alarm monitors, limit switches, indication lamps, etc. and cleaning of all terminals using Carbon tetra chloride, painting of panel board.
Appendix – B – (Spare parts)
Thermocouple K Type (For primary chamber)
Thermocouple KER 710 (For secondary chamber)
V Belt B-97
RTD assembly for ventury outlet
Hose Metallic Braided 3/8 x 40
Digital Temperature Controller 0-1200degC
Contactor 32 A,230 V coil
Contactor 12 A ,230 V coil
Overload Relay 14-23A
Overload Relay 1.4-2.3A
roller bearing 1312 K
sleeve H 312
Star/delta timer
Appendix – C – (Labour charges)
Engaging overall BANDHANI for 70 days. (1 No. /shift for 2 shifts/day) (2*70=140 Nos.)
Engaging SCAVENGER for loading of garbages into the incinerator for 70 days.(2 Nos. of machines) (3 Nos./shift for 2 shifts/day /machine) (3*2*70*2)=840 Nos.)
Engaging SCAVENGER to segregate bio-degradable waste and plastic materials from the garbages for 70 days (5 Nos./shift for 3 shifts/day)(5*2*70)=1050 Nos.)
Appendix – D
Conveyance charges for departmentally supplied Diesel
Cloth Mask
Rubber Gloves 14''
Rubber Gloves 18''
Appendix – E (Elephant Guard)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
Appendix – F
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm)
HARILAL P.V
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .