Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.15Admitted-Finance PULLIYIL PARAMMA THODY HOUSE MELMURI PO MALAPPURAM 676517 MALAPPURAM | MALAPPURAM | KERALA | 676517 | +14.60% | ₹1.15 | L1 | Admitted-Finance |
| 2 | L2₹1.28Admitted-Finance SIVAJYOTHI ENGOLIPARAMBU KARANTHUR 673571 | KOZHIKODE | KERALA | 673571 | +27.88% | ₹1.28 | L2 | Admitted-Finance |
| 3 | L3₹1.45Admitted-Finance | +45.00% | ₹1.45 | L3 | Admitted-Finance |
| 4 | L4₹1.48Admitted-Finance KOZHIKALPARAMBATH H KOTTAPARAMBA PO KOZHIKODE 673008 | KOZHIKODE | KERALA | 673008 | +48.00% | ₹1.48 | L4 | Admitted-Finance |
Updated dates
Tender Value
₹72 L
EMD Value
₹1.4 L
Closing Date
8 Apr 2026, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Running contract for various urgent civil works including annual maintenance works of institute buildings (mainly academic buildings) in NITC (2025-26)
2026_NITC_902052_1
Engg/D1/JE3/426/2025-26
Open Tender
Civil Works
365 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.4 L
Yes
28 Apr 2026
11 Mar 2026
10 Apr 2026
11 Mar 2026
8 Apr 2026
11 Mar 2026
Running contract for various urgent civil works including annual maintenance works of institute buildings (mainly academic buildings) in NITC for a period of one year, scope of which is detailed in Annexure II of the Notice Inviting Tender. The quoted percentage will be applied on each individual items mentioned in the sheet 'Items' of this BoQ Excel file, while operating the contract.
Detailed Estimate
EARTH WORK
Earth work in surface excavation of all kinds of soil (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge.
Earth work in excavation of all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.
Earth work in excavation of ordinary rock by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Banking excavated earth of all kinds of soil by mechanical/manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift.
Filling quarry muck in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :Details of cost for 10 cum.
Earth work in excavation of all kinds of soil by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Excavation work of ordinary rock by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, by mechanical/manual means ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc, not exceeding 80 mm dia.
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, by mechanical/manual means ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc, not exceeding 80 mm dia. But not exceeding 300mm dia
Excavating trenches of required width in all kinds of soil for pipes, cables, etc. including excavation for sockets, and dressing of sides, by mechanical/manual means ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc. exceeding 300 mm dia but not exceed ng 600 mm
Excavating trenches of required width in ordinary rock for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. not exceeding 80 mm dia
Excavating trenches of required width in ordinary rock for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia ,
Excavating trenches of required width in ordinary rock for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : Pipes, cables exceeding 300 mm dia but not exceeding 600 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and for all lift
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in foundation, trenches, plinth, sides of foundation, etc. complete for all lift.
ySupplying and filling in plinth with sand under floo
ding watering, ramming, consolidating and dressing complete.1*0¸Surface dressing of all kinds of soil in the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50m and lift up to 1.5m.10`Excavating holes more than 0.10 cum & upto 0.5 cum in all kinds of soil including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5m.10üClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.10mClearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.10Felling trees having girth beyond 30 cm upto and including 60 cm girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.10;1F01.22mSupplying Chlorpyriphos emulsifiable concentrate of 20% in sealed containers including delivery as specified.101.23Diluting and injecting Chlorpyriphos E.C. 20% chemical emulsion with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) along external wall where the apron is not provided using chemical emulsion @ 7.5 litres/sqm on the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. completem10¯1Â01.24ÅDiluting and injecting Chlorpyriphos E.C. 20% chemical emulsion with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) for treatment of existing masonry using Chlorpyriphos E.C. 20% chemical emulsion with 1% concentration @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the holen10½1Ð01.25óTreatment at points of contact of wood work by chemical emulsion Chlorpyriphos (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.1+0Providing and laying in position cement concrete of grade 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering and shuttering - All work up to plinth level.:1?0 1 Providing and laying cement concrete of grade 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing..130Í1ä0 Providing and laying cement concrete of grade 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing..130Î1ä0Centering and shuttering including strutting, propping etc. and removal of formwork for Columns, piers, abutments, pillars, posts and struts4.3.3(Providing and laying cement concrete 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing.%1+0¼1È0Providing and fixing at or near ground level precast cement concrete 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete.-1K0Û1é0Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.1N03.13CProviding and fixing 18 mm thick ferrocement boards with cement mortar 1:3 with coarse sand and reinforced welded mesh(20 Gauge) , chicken mesh (10Kg) in required thickness for bedroom, kitchen cupboards including cost and conveyance of all materials, labour charges, etc., complete, as per direction of Engineer-in-charge. 130EProviding and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level!1(031ÞReinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) grade of concreteÔ1ê061=0ÖReinforced cement concrete work in beams, suspended floors, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).Ú1ð0@1G0Centering and shuttering including strutting, propping etc. and removal of formwork for Foundations, footings, bases of columns, etc. for mass concrete5.9.1ÃCentering and shuttering including strutting, propping etc. and removal of formwork for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.5.9.2ÈProviding, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).21H0I1k00170ÈThermo-Mechanically Treated Steel reinforcement bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.>1E0¶1Ç0ÉThermo-Mechanically Treated Steel reinforcement bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.>1E0¶1È0Thermo-Mechanically Treated Steel reinforcement bars of grade Fe-500D or more for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level.>1E0l1x0ô1Thermo-Mechanically Treated Steel reinforcement bars of grade Fe-500D or more for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level.>1E0l1x0ô1[Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.1#04.17"Providing and laying in position ready mixed or site batched design mix cement concrete of M25 grade with minimum cement content of 330 kg /cum for reinforced cement concrete work for all works upto plinth level; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.!1,0[1^0Â1Ó04.18ûProviding and fixing in position factory made precast RCC M-40 door and window frame of size 100 mmx 60 mm, fixing with hold fast embedded in 1:3:6 concrete block, having excellent smooth finish as per IS: 6523 with reinforcement of 3 Nos, 6 mm dia main bars tied with 3 ram M.S stirrups placed @ 200 mm C/C and 6 numbers high strength polymer blocks of required size for fixing hinges including providing 6 no specially designed M.S. galvanised sleeves for accomodating 6 mm dia fully threaded bolts for fixing hold fast on vertical members, providing suitable arrangement for recieving sliding door bolts and tower bolt etc. all complete, as per the direction of Engineer-in-charge. The frame shall be measured in running metre correct to two places of decimal..1T0Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4(1 cement :4 coarse sand)6.1.1Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)1 0M1b0×Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand)1 0|10¦Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4(1 cement :4 coarse sand)6.12.2ÃHalf brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4(1 cement :4 coarse sand)6.13.2Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonry 100 mm / 125mm thick with Grade 1 AAC blocks of density 551 to 650 kg/cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.11=0F1Z0Ö1é0ÑProviding and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick AAC with Grade-1 blocks of density 551-650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).11>0F1^0Ö1é0êLaterite masonry for foundation and basement upto plinth level including all cost of materials, labour charges etc. with neatly dressed laterite stone of size 35x20x20cm or nearest size, in cement mortar 1:6 (1 cement : 6 coarse sand)10-1>05.105.11÷Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size for superstructure above plinth level up to floor two level including all cost of materials, labour charges etc. in cement mortar 1:6 (1 cement : 6 coarse sand)10}105.12*Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For foundation, basement and plinth upto plinth level including all cost of materials, labour charges etc.using blocks of 200mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1¥05.13*Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For foundation, basement and plinth upto plinth level including all cost of materials, labour charges etc.using blocks of 200mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)p1¥05.14+Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For foundation, basement and plinth upto plinth level including all cost of materials, labour charges etc. using blocks of 150mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1¥05.15+Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For foundation, basement and plinth upto plinth level including all cost of materials, labour charges etc. using blocks of 150mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)o1¥05.16+Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For foundation, basement and plinth upto plinth level including all cost of materials, labour charges etc. using blocks of 100mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1¥05.17+Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For foundation, basement and plinth upto plinth level including all cost of materials, labour charges etc. using blocks of 100mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)p1¥05.183Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. using blocks of 200mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1«05.193Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. using blocks of 200mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)p1«05.203Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. using blocks of 150mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1«05.213Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. using blocks of 150mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)o1«05.223Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. using blocks of 100mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)5.233Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor two level, including all cost of materials, labour charges etc. using blocks of 100mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)5.244Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. using blocks of 200mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p105.254Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. using blocks of 200mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)o1¬05.264Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. using blocks of 150mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1¬05.274Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. using blocks of 150mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)p1¬05.284Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. using blocks of 100mm thickness, in cement mortar 1:6 (1 cement : 6 coarse sand)p1¬05.294Providing and laying factory made precast cement concrete solid blocks of grade M10 from approved manufacturer: For superstructure above plinth level up to floor five level, including all cost of materials, labour charges etc. using blocks of 100mm thickness, in cement mortar 1:4 (1 cement : 4 coarse sand)o1¬0ÿRandom rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with cement mortar 1:6 (1 cement : 6 coarse sand)10)1>0@Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level with cement mortar 1:6 (1 cement : 6 coarse sand), including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.10O1d0lDry rubble masonry in foundation and plinth including levelling up upto plinth level with blasted hard stone101+0\Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut granite stone slab for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of area upto 0.50 sqm and of colour black, Cherry/Ruby red\Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut granite stone slab for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of area over 0.50 sqm and of colour black, Cherry/Ruby redpProviding and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut granite stone slab for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of area upto 0.50 sqm and all colour and texture except black, Cherry/Ruby redpProviding and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut granite stone slab for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of area over 0.50 sqm and all colour and texture except black, Cherry/Ruby redÆProviding edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 10'130ÇProviding edge moulding to 18 mm thick granite stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 10'140Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.1041Q07.09ÌProviding and fixing wedge expansion type hold fasteners on C.C./R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc. complete. Fastener with threaded dia 6 mm7.10ÍProviding and fixing wedge expansion type hold fasteners on C.C./R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc. complete. Fastener with threaded dia 10 mm7.11ÍProviding and fixing wedge expansion type hold fasteners on C.C./R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc. complete. Fastener with threaded dia 12 mm7.12±Providing and fixing 75 mm high, 50 mm deep and 18 mm thick White Agaria Marble Stone slab table rubbed, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.<1U0107.13õProviding and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.!1:01'07.14 Providing and laying Vitrified wall tiles with diferent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Glazed vitrified tile polished finish of Size of tile 600x600 mm1)0Ê18.500.17.15 Providing and laying Vitrified wall tiles with diferent sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Glazed Vitrified tiles Matt/Antiskid finish of size 600 x 600 mm1)0Ê18.500.27.16Providing and Fixing Armstrong or equivalent Channelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a "Helmholtz" fluted perforation with consecutive 3mm wide groove followed by 21mm of visible pane. The edges of the panel shall be "tongue-and-grooved" to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Armstrong and approved by the Architect/ Engineer-in-Charge.Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) with Second class teak wood109.1.1Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge (Note: Butt hinges and necessary screws shall be paid separately) with Second class teak wood of 30 mm thick shutters1=0k19.5.1.2ZProviding and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled ur panelled and glazed shutters 25 mm to 40 mm thick using Second class teak wood170D19.7.1Providing and fixing panelling for panelled or panelled and glazed shutters of 25 mm to 40 mm thickness for doors, windows and clerestory windows using pre-laminated particle board 12mm thick with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured)10C1K0g10Å1 0kProviding and fixing panelling for panelled or panelled and glazed shutters of 25 mm to 40 mm thickness for doors, windows and clerestory windows using pre-laminated particle board 12mm thick with decorative lamination on both sides, Grade I, Type II, IS:12823 marked (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured)10C1K0g10Å1è01Providing and fixing glazing for panelled or panelled and glazed shutters of 25 mm to 40 mm thickness for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10kg/sqm) (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured)101²0nProviding and fixing panelling for panelled or panelled and glazed shutters of 25 mm to 40 mm thickness for doors, windows and clerestory windows using fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured)101Æ04Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not les
愠摮映硩湩卉⁉慭歲摥卉ㄺ㐳ⰱ䴠匮敨癡⁹敷杩瑨戠楲桧⁴楦楮桳摥戠瑵⁴楨杮獥眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整㨠㔷㙸砰⸳〱洠譭牐癯摩湩湡楦楸杮䤠䥓洠牡敫Ɽ䤠㩓㌱ㄴ⹍⹓栠慥祶眠楥桧⁴牢杩瑨映湩獩敨畢瑴栠湩敧楷桴渠捥獥慳祲猠牣睥瑥挠浯汰瑥›〵㑸砰⸲〵洠筭牐癯摩湩湡楦楸杮䤠㩓㈱ㄸ‷慭歲摥猠慴湩敬獳猠整汥戠瑵⁴楨杮獥眠瑩瑳楡汮獥瑳敥捳敲獷攠捴潣灭敬整㨠ㄠ㔲㙸破⸱〹洠筭牐癯摩湩湡楦楸杮䤠㩓㈱ㄸ‷慭歲摥猠慴湩敬獳猠整汥戠瑵⁴楨杮獥眠瑩瑳楡汮獥瑳敥捳敲獷攠捴潣灭敬整㨠ㄠ〰㕘堸⸱〹洠穭牐癯摩湩湡楦楸杮䤠㩓㈱ㄸ‷慭歲摥猠慴湩敬獳猠整汥戠瑵⁴楨杮獥眠瑩瑳楡汮獥瑳敥捳敲獷攠捴潣灭敬整㨠㜠砵㜴ㅸ㠮‰浭z倀潲楶楤杮愠摮映硩湩卉ㄺ㠲㜱洠牡敫瑳楡汮獥瑳敥畢瑴栠湩敧楷桴猠慴湩敬獳猠整汥猠牣睥瑥挠浯汰瑥›〵㍸砷⸱〵洠詭牐癯摩湩湡楦楸杮䤠㩓㈱ㄸ‷慭歲摥猠慴湩敬獳猠整汥戠瑵⁴楨杮獥⠠敨癡⁹敷杩瑨 楷桴猠慴湩敬獳猠整汥猠牣睥瑥挠浯汰瑥›㈱砵㐶㉸㔮‰浭倀潲楶楤杮愠摮映硩湩卉ㄺ㠲㜱洠牡敫瑳楡汮獥瑳敥畢瑴栠湩敧栨慥祶眠楥桧⥴眠瑩瑳楡汮獥瑳敥捳敲獷攠捴潣灭敬整㨠ㄠ〰㙸砰⸲〵洠襭牐癯摩湩湡楦楸杮䤠㩓㈱ㄸ‷慭歲摥猠慴湩敬獳猠整汥戠瑵⁴楨杮獥⠠敨癡⁹敷杩瑨 楷桴猠慴湩敬獳猠整汥猠牣睥瑥挠浯汰瑥›㔷㕸砰⸲〵洠ࠀ牐癯摩湩湡楦楸杮戠楲桧⁴楦楮桳摥戠慲獳ㄠ〰洠潭瑲捩慬捴湡潬正眠瑩‶敬敶獲愠摮愠瀠楡景氠癥牥栠湡汤獥漠灡牰癯摥焠慵楬祴眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整ᔮ㼀 ࠀ牐癯摩湩湡楦楸杮挠牨浯畩汰瑡摥戠慲獳ㄠ〰洠潭瑲捩慬捴湡潬正眠瑩‶敬敶獲愠摮愠瀠楡景氠癥牥栠湡汤獥漠灡牰癯摥焠慵楬祴眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整ᔮ㼀 ꨀ牐癯摩湩湡楦楸杮猠数楣污焠慵楬祴戠楲桧⁴楦楮桳摥戠慲獳挠灵潢牡牯眠牡牤扯潬正楷桴映畯敬敶獲漠灡牰癯摥焠慵楬祴椠据畬楤杮渠捥獥慳祲猠牣睥瑥挠浯汰瑥㐠‰浭ª倀潲楶楤杮愠摮映硩湩灳捥慩畱污瑩⁹牢杩瑨映湩獩敨牢獡畣扰慯摲漠慷摲潲敢氠捯獫眠瑩潦牵氠癥牥景愠灰潲敶畱污瑩⁹湩汣摵湩敮散獳牡⁹捳敲獷攠捴潣灭敬整〵洠ꩭ牐癯摩湩湡楦楸杮猠数楣污焠慵楬祴戠楲桧⁴楦楮桳摥戠慲獳挠灵潢牡牯眠牡牤扯潬正楷桴映畯敬敶獲漠灡牰癯摥焠慵楬祴椠据畬楤杮渠捥獥慳祲猠牣睥瑥挠浯汰瑥㘠‵浭ª倀潲楶楤杮愠摮映硩湩灳捥慩畱污瑩⁹牢杩瑨映湩獩敨牢獡畣扰慯摲漠慷摲潲敢氠捯獫眠瑩潦牵氠癥牥景愠灰潲敶畱污瑩⁹湩汣摵湩敮散獳牡⁹捳敲獷攠捴潣灭敬整㔷洠癭ࠀ牐癯摩湩湡楦楸杮㔠‰浭戠楲桧⁴楦楮桳摥戠慲獳挠灵戠慯摲漠慷摲潲敢欠潮景愠灰潲敶畱污瑩⁹楷桴渠捥獥慳祲猠牣睥11K0T倀潲楶楤杮愠摮映硩湩牢杩瑨映湩獩敨牢獡慨摮敬楷桴猠牣睥瑥挠浯汰瑥㩥ㄠ㔲洠呭牐癯摩湩湡楦楸杮戠楲桧⁴楦楮桳摥戠慲獳栠湡汤獥眠瑩捳敲獷攠捴潣灭敬整›〱‰浭S倀潲楶楤杮愠摮映硩湩牢杩瑨映湩獩敨牢獡慨摮敬楷桴猠牣睥瑥挠浯汰瑥㩥㜠‵浭pЈ倀潲楶楤杮愠摮映硩湩牢杩瑨映湩獩敨牢獡慨杮湩祴数映潬牯搠潯瑳灯数楷桴渠捥獥慳祲猠牣睥ⱳ攠捴潣灭敬整┮⨀ 㸀䨀 ࠁ牐癯摩湩湡楦楸杮愠畬業楮浵搠敩挠獡⁴潢祤琠扵汵牡琠灹湵癩牥慳票牤畡楬潤牯挠潬敳栨癡湩牢湡潬潧眠瑩卉ⱉ䤠⁓›㔳㐶浥潢獳摥漠桴潢祤潤牯眠楥桧⁴灵潴㌠‵杫愠摮搠潯楷瑤灵潴㜠〰洠⥭楷桴渠捥獥慳祲愠捣獥潳楲獥愠摮猠牣睥瑥挠浯汰瑥D1Y01®0ĹЈ倀潲楶楤杮愠摮映硩湩污浵湩畩硥牴摵摥猠捥楴湯戠摯⁹畴畢慬祴数甠楮敶獲污栠摹慲汵捩搠潯汣獯牥⠠慨楶杮戠慲摮氠杯楷桴䤠䥓卉㨠㌠㘵ⰴ攠扭獯敳湯琠敨戠摯ⱹ搠潯敷杩瑨映潲㘳欠潴㠠‰杫愠摮搠潯楷瑤牦浯㜠洠潴ㄠ〰‰浭Ⱙ眠瑩潤扵敬猠数摥愠橤獵浴湥⁴楷桴渠捥獥慳祲愠捣獥潳楲獥愠摮猠牣睥瑥挠浯汰瑥L1a0 1¿0u倀潲楶楤杮愠摮映硩湩牢杩瑨映湩獩敨牢獡慨灳愠摮猠慴汰猨晡瑥⁹祴数 楷桴渠捥獥慳祲猠牣睥瑥挠浯汰瑥›㔱‰浭t倀潲楶楤杮愠摮映硩湩牢杩瑨映湩獩敨牢獡慨灳愠摮猠慴汰猨晡瑥⁹祴数 楷桴渠捥獥慳祲猠牣睥瑥挠浯汰瑥›〹洠牐癯摩湩湡楦楸杮愠畬業楮浵猠楬楤杮搠潯潢瑬ⱳ䤠䥓洠牡敫湡摯獩摥⠠湡摯捩挠慯楴杮渠瑯氠獥桴湡朠慲敤䄠⁃〱愠数卉㨠ㄠ㘸⤸牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵漠桳摡ⱥ眠瑩畮獴愠摮猠牣睥瑥挠浯汰瑥›〳砰㘱洠牐癯摩湩湡楦楸杮愠畬業楮浵猠楬楤杮搠潯潢瑬ⱳ䤠䥓洠牡敫湡摯獩摥⠠湡摯捩挠慯楴杮渠瑯氠獥桴湡朠慲敤䄠⁃〱愠数卉㨠ㄠ㘸⤸牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵漠桳摡ⱥ眠瑩畮獴愠摮猠牣睥瑥挠浯汰瑥㈺〵ㅸ‶浭㠀㔮牐癯摩湩湡楦楸杮愠畬業楮浵琠睯牥戠汯獴卉⁉慭歲摥湡摯獩摥⠠湡摯捩挠慯楴杮渠瑯氠獥桴湡朠慲敤䄠⁃〱愠数卉㨠ㄠ㘸‸ 牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵漠桳摡ⱥ眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整㨠㌠〰ㅸ‰浭㠀㔮牐癯摩湩湡楦楸杮愠畬業楮浵琠睯牥戠汯獴卉⁉慭歲摥湡摯獩摥⠠湡摯捩挠慯楴杮渠瑯氠獥桴湡朠慲敤䄠⁃〱愠数卉㨠ㄠ㘸‸ 牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵漠桳摡ⱥ眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整㨠㈠〵ㅸ‰浭㠀㔮퐳ࠀ牐癯摩湩湡楦楸杮ㄠ㔲洠污浵湩畩慨摮敬ⱳ䤠䥓洠牡敫Ɽ愠潮楤敳愨潮楤潣瑡湩潮⁴敬獳琠慨牧摡䍁ㄠ‰獡瀠牥䤠⁓›㠱㠶 牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵漠桳摡ⱥ眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整1-0㠀㔮ࠀ牐癯摩湩湡楦楸杮愠畬業楮浵栠湡楧杮映潬牯猠湩汧畲扢牥搠潯瑳灯数Ⱳ䤠䥓洠牡敫Ɽ愠潮楤敳愨潮楤潣瑡湩潮⁴敬獳琠慨牧摡䍁ㄠ‰獡瀠牥䤠⁓›㠱㠶 牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵愠摮猠慨敤楷桴渠捥獥慳祲猠牣睥瑥挠浯汰瑥-1G0㠀㔮혵ࠀ牐癯摩湩湡楦楸杮愠畬業楮浵挠獡浥湥⁴瑳祡ⱳ䤠䥓洠牡敫Ɽ愠潮楤敳愨潮楤潣瑡湩潮⁴敬獳琠慨牧摡䍁ㄠ‰獡瀠牥䤠⁓›㠱㠶 牴湡灳牡湥⁴牯搠敹潴爠煥極敲潣潬牵愠摮猠慨敤楷桴渠捥獥慳祲猠牣睥瑥挠浯汰瑥1-0㠀㔮शࠁ牐癯摩湩湡楦楸杮戠楲桧⁴楦楮桳摥戠慲獳ㄠ〰洠潭瑲捩慬捴湡潬正卉⁉慭歲摥楷桴猠硩氠癥牥湡慰物漠湡摯獩摥⠠湡摯捩挠慯楴杮渠瑯氠獥桴湡朠慲敤䄠⁃〱愠数卉㨠ㄠ㘸⤸愠畬業楮浵氠癥牥栠湡汤獥漠灡牰癯摥焠慵楬祴眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整ᔮ䠀 琀簀 뤀퀀 Ѐ⸸㜵Ȉ倀潲楶楤杮愠摮映硩湩潰摷牥挠慯整整敬捳灯捩搠慲敷档湡敮獬㌠〰洠潬杮眠瑩敮散獳牡⁹捳敲獷攠捴潣灭敬整愠数楤敲瑣潩獮漠湅楧敮牥湩挭慨杲#1I0㠀㔮㈸ंProviding and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension of 48x40 mm (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19x19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer-in-charge"110㠀㔮甹ࠄ牐癯摩湩湡楦楸杮㈠‴浭琠楨正映捡潴祲洠摡噐⁃潤牯猠畨瑴牥慭敤漠瑳汹獥愠摮爠楡獬漠偵䍖栠汯潬⁷敳瑣潩景猠穩㤵㉸‴浭愠摮眠污桴捩湫獥′浭⠠₱⸰′浭 楷桴椠扮極瑬攠杤湩湯戠瑯楳敤潴攠楸瑳湩潤牯映慲敭吠敨猠祴敬湡慲汩業牴摥愠摮樠楯瑮愠⁴桴潣湲牥祢洠慥獮漠⹍⹓朠污慶楮敳⽤瀠慬瑳捩戠慲正瑥景猠穩㔷㉸〲洠慨楶杮眠污桴捩湫獥⸱‰浭愠摮猠慴湩敬獳猠整汥猠牣睥吠敨猠祴敬景琠敨猠畨瑴牥爠楥普牯散祢椠獮牥楴杮朠污慶楮敳⹍⹓琠扵景猠穩〲㉸‰浭愠摮ㄠ洠넨〠ㄮ洠⥭眠污桴捩湫獥吠敨氠捯慲汩洠摡灵漠䠧‧敳瑣潩Ɱ愠甠噐⁃潨汬睯猠捥楴湯漠楳敺ㄠ〰㉸‴浭愠摮㈠洠넨〠㈮洠⥭眠污桴捩湫獥ⱳ映硩摥琠桴桳瑵整瑳汹獥戠⁹敭湡景瀠慬瑳捩术污慶楮敳⹍⹓✠❕挠敬瑡吠敨猠畨瑴牥映慲敭映汩敬楷桴愠甠噐⁃畭瑬档浡敢敲楳杮敬瀠湡汥漠楳敺渠瑯氠獥桴湡㘠〲洠Ɑ栠癡湩癯牥愠汬琠楨正敮獳漠〲洠湡‱浭⠠₱⸰‱浭 慷汬琠楨正敮獳桔慰敮獬映汩敬敶瑲捩污祬愠摮琠敩戠牡愠⁴睴汰捡獥戠⁹湩敳瑲湩潨楲潺瑮污祬㘠洠慧癬湡獩摥䴠匮潲湡慦瑳湥摥眠瑩畮獴愠摮眠獡敨獲潣灭敬整愠数慭畮慦瑣牵牥猧猠数楣楦慣楴湯愠摮搠物捥楴湯漠湅楧敮牥椭档牡敧䘨牯圠䌮湡慢桴潲浯搠潯桳瑵整⥲⸮㼀 Ѐ⸸〶ŬĈ倀潲楶楤杮愠摮映硩湩㈱洠桴捩慰敮汬湩牯瀠湡汥楬杮愠摮朠慬楺杮椠瀠湡汥敬牯瀠湡汥敬湡汧穡摥猠畨瑴牥潦潤牯ⱳ眠湩潤獷愠摮挠敬敲瑳牯⁹楷摮
ws (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Marine plywood conforming to IS: 710H18.61ÊProviding and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge1'0:1G0a1o0É1 08.62Providing and fixing cup board shutters with 25 mm thick veneered particle board with decorative veneering on one side and commercial veneering on other side, IS:3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.1'081P0V108.63Providing and fixing bright/matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm8.64Providing and fixing bright/matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100mm8.65uProviding and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately).91Z08.66FProviding and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer- in-charge.81Z08.67ÄProviding and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer- in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)1%061m0}108.68Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer etc. including necessary nails, screws, etc., complete as per direction of Engineer-in-charge. 1>0O1c08.69Providing and fixing stainless steel fancy handle (200 mm size) of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.1108.70Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge.%1?08.71¸Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.%1W08.72Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) 1P08.73ûProviding and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge./1D08.74Providing and fixing Zebra blinds curtain of preferred colour, including cost and conveyance complete, as per instruction of Engineer-in-charge.8.75Providing and fixing bright finished Stainless Steel Aldrop (Sliding door bolt) (250x16x5 mm size) with necessary screws etc. complete.%1O0ÑStructural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.31D0F1M0R1]09Steel work in built up tubular (Electric resistance or induction butt welded, round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10 1L0~1 0=Steel work in built up tubular (hot-dip galvanized (Tata Structura or equivalent) round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10 12010½Steel work in built up tubular (hot-dip galvanized (Tata Structura or equivalent) round, square or rectangular hollow tubes etc.) for curved trusses (Arch, Parabolic, etc.), including uniformly machine bending the section to required curves, cutting, hoisting, lifting with mechanical cranes etc, and fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.12010Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.Æ10ÜProviding and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, using E.R.W. tubes, including applying priming coat of approved steel primer.101¡0ÚProviding and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, using G.I. pipes, including applying priming coat of approved steel primer.1010Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)180ÑProviding & fixing Stainless steel (grade 304) fly proof wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.1C0©Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.1I0ó40 mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.1$0 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.1$0Cement plaster skirting 18 mm thick up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.10Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.10GChequered precast cement concrete tiles 22 mm thick, made using ordinary cement mixed with dark shade pigment, in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)130.Polished 8 mm thick Raj Nagar marble tiles work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.1U04Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Makrana white second quality1011.23.1'Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Raj Nagar plain1011.23.2$Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Agaria White1011.23.3,Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur green marble1011.23.5)Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Pink plain marble101&011.23.6§Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.1B0ÀProviding and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.1C0òProviding and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.!1;01'0£Providing and laying vitrified floor tiles of size 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.1=0æ1þ0ÌProviding and laying Vitrified tiles of size 600x600 mm in floor (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).170140¶Providing and laying Vitrified tiles of size 600x600 mm (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.170Ô10ßProviding and laying Vitrified tiles of size 600x600 mm (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)170è1I0¸Providing and laying Double charge vitrified floor tiles polished finish of size 600 x 600 mm in floor (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.01]0±Providing and laying Glazed vitrified floor tiles polished finish of size 600 x 600 mm in floor (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.01V0¶Providing and laying Glazed vitrified floor tiles Matt/Antiskid finish of size 600 x 600 mm in floor (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.01[0¢Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm.1.010.23¬Fixing glazed/Ceramic/Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.>1k010.24-Grouting the joints of 600x600 mm sized flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Z1i010.25tDeduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles.1010.26AProviding and laying Polished Granite stone slab flooring of colour Black, Cherry/Ruby Red or equivalent in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.190D1Z010.27LProviding and laying Polished Granite stone slab flooring of all colour and texture, except Black, Cherry/Ruby Red, in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.190U1s010.28ÊProviding and laying good quality floor carpet with quick-set adhesive including cost and conveyance of all materials and labour charges etc. complete. Synthetic floor carpet of 4mm or nearest thickness111.505.1ñProviding and fixing on wall face single socketed unplasticised Rigid PVC rain water pipes of 110 mm diameter conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion@1m010 Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. 110 mm Couplerÿ1Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. 110 mm Single pushfit Couplerÿ1"Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. 110x110x110 mm Single tee with doorÿ1%Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. 110x110x110 mm Single tee without doorÿ1Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion. 110 mm Bend 87.5°ÿ1Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:1
祔数䄠湩汣摵湩潪湩楴杮眠瑩敳污爠湩潣普牯業杮琠卉㔺㠳ⰲ氠慥楶杮ㄠ‰浭朠灡映牯琠敨浲污攠灸湡楳湯ㄱ‰浭匠潨倨慬湩I䰀ࠁ牐癯摩湩湡楦楸杮ㄠ〱洠楤湵汰獡楴楣敳噐⁃楰数挠楬獰漠灡牰癯摥搠獥杩潴甠灮慬瑳捩獩摥ⴠ倠䍖爠楡慷整楰数祢洠慥獮漠〵㕸砰〵洠慨摲眠潯汰杵ⱳ猠牣睥摥眠瑩⹍⹓猠牣睥景爠煥極敲敬杮桴湩汣摵湩畣瑴湩牢捩潷歲愠摮映硩湩湩挠浥湥⁴潭瑲牡ㄠ㐺⠠‱散敭瑮›‴潣牡敳猠湡⥤愠摮洠歡湩潧摯琠敨眠污瑥挠浯汰瑥1<0Ȉ倀潲楶楤杮愠摮映硩湩潴琠敨椠汮瑥洠畯桴漠慲湩眠瑡牥瀠灩慣瑳椠潲牧瑡湩㔱挠楤浡瑥牥愠摮眠楥桧湩潮⁴敬獳琠慨㐴‰牧浡;1R0ࡓĈ倀潲楶楤杮愠摮映硩湩慦獬散汩湩瑡愠汬栠楥桧獴椠据畬楤杮瀠潲楶楤杮愠摮映硩湩景映慲敭眠牯慭敤漠灳捥慩敳瑣潩獮潰敷牰獥敳牦浯䴠匮桳敥獴愠摮†慧癬湡穩摥眠瑩楺据挠慯楴杮漠㈱‰浧⽳煳⠠潢桴†楳敤椠据畬楳敶 獡瀠牥䤠⁓›㜲‷湡潣獮獩楴杮漠湡汧汣慥獴漠楳敺㈠‵浭眠摩⁸⸱‶浭琠楨正眠瑩汦湡敧景㈠‷浭愠摮㌠洷Ɑ愠⁴㈱〰洠散瑮敲琠散瑮敲湯汦湡敧映硩摥琠桴散汩湩楷桴搠獡慦瑳湥牥ㄠ⸲‵浭搠慩砠㔠‰浭氠湯楷桴㘠洠楤潢瑬ⱳ漠桴牥映慬杮景挠敬瑡映硩摥琠桴湡汧慨杮牥景㈠砵〱へ㔮‰浭漠敲畱物摥氠湥瑧楷桴渠瑵…潢瑬景爠煥極敲楳敺愠摮漠桴牥攠摮漠湡汧慨杮牥映硩摥眠瑩湩整浲摥慩整䜠䤮档湡敮獬㐠砵㔱へ㤮洠畲湮湩瑡琠敨猠慰楣杮漠㈱〰洠散瑮敲琠散瑮敲潴眠楨档琠敨挠楥楬杮猠捥楴湯〠㔮洠桴捩潢瑴浯眠摥敧漠〸洠楷桴琠灡牥摥映慬杮獥漠㘲洠慥档栠癡湩楬獰漠〱㔮洠Ɑ愠⁴㔴‰浭挠湥牴潴挠湥牴ⱥ猠慨汬戠楦數湩愠搠物捥楴湯瀠牥数摮捩汵牡琠⹇⹉椠瑮牥敭楤瑡档湡敮楷桴挠湯敮瑣湩汣灩慭敤漠瑵漠⸲㐶洠楤⁸㌲‰浭氠湯⹇⹉眠物瑡攠敶祲樠湵瑣潩Ɱ椠据畬楤杮映硩湩数楲敭整档湡敮獬〠㔮洠桴捩㜲洠楨桧栠癡湩汦湡敧景㈠‰浭愠摮㌠‰浭氠湯Ⱨ琠敨瀠牥浩瑥牥漠散汩湩楦數潴眠污⽬慰瑲瑩潩楷桴琠敨栠汥⁰景爠睡汰杵瑡㐠〵洠散瑮敲楷桴㈠‵浭氠湯牤⁹慷汬猠牣睥⁀㌲‰浭椠瑮牥慶ⱬ椠据畬楤杮映硩湩景朠灹畳潢牡潴挠楥楬杮猠捥楴湯愠摮瀠牥浩瑥牥挠慨湮汥眠瑩桴敨灬漠牤⁹慷汬猠牣睥景猠穩⸳‵⁸㔲洠瑡㈠〳洠⽣Ᵽ椠据畬楤杮樠楯瑮湩湡楦楮桳湩潴愠映畬桳映湩獩景琠灡牥摥愠摮猠畱牡摥敧景琠敨戠慯摲眠瑩敲潣浭湥敤潪湩楴杮挠浯潰湵潪湩楴杮琠灡獥Ⱐ映湩獩楨杮眠瑩潪湩楴杮挠浯潰湵湩㌠氠祡牥潣敶楲杮甠瑰㔱‰浭漠潢桴猠摩獥漠潪湩⁴湡睴潣瑡景瀠楲敭畳瑩扡敬映牯戠慯摲污獡瀠牥洠湡晵捡畴敲❲灳捥晩捩瑡潩湡污潳椠据畬楤杮琠敨挠獯⁴景洠歡湩灯湥湩獧映牯氠杩瑨映瑩楴杮ⱳ朠楲汬ⱳ搠晩獵牥ⱳ挠瑵畯獴洠摡楷桴映慲敭漠数楲敭整档湡敮獬猠極慴汢⁹楦數Ɽ愠汬挠浯汰瑥獡瀠牥搠慲楷杮ⱳ猠数楣楦慣楴湯愠摮搠物捥楴湯漠桴湅楧敮牥椠桃牡敧戠瑵攠捸畬楤杮琠敨挠獯⁴景瀠楡瑮湩楷桴㨠ㄠ⸲‵浭琠楨正琠灡牥摥攠杤祧獰浵瀠慬湩戠慯摲挠湯潦浲湩潴䤠㩓㈠㤰ⴵ⠠慐瑲䤠 ㈺‱䈨慯摲眠瑩䥂⁓散瑲晩捩瑡潩慭歲⥳ߚ1⸲㔴ㄮࠔĈ倀潲楶楤杮愠摮映硩湩慦獬散汩湩瑡愠汬栠楥桧獴椠据畬楤杮瀠潲楶楤杮愠摮映硩湩景映慲敭眠牯慭敤漠灳捥慩敳瑣潩獮潰敷牰獥敳牦浯䴠匮桳敥獴愠摮†慧癬湡穩摥眠瑩楺据挠慯楴杮漠㈱‰浧⽳煳⠠潢桴†楳敤椠据畬楳敶 獡瀠牥䤠⁓›㜲‷湡潣獮獩楴杮漠湡汧汣慥獴漠楳敺㈠‵浭眠摩⁸⸱‶浭琠楨正眠瑩汦湡敧景㈠‷浭愠摮㌠洷Ɑ愠⁴㈱〰洠散瑮敲琠散瑮敲湯汦湡敧映硩摥琠桴散汩湩楷桴 dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, difusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant boardÚ112.45.3¼Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms.;1?0_1{0ÐProviding & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)..1<0´Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately)."120xProviding and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required./1=0«Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: Ridges plain (500 - 600mm)1I0±Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: Flashings/ Aprons.( Upto 600 mm)1I011.18ªProviding and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: Barge board (Upto 300 mm)1I011.19Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: Crimp curve1I011.20Providing and fixing tiled false ceiling of 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, (made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit), in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main 'T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm die and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre- painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.,1r011.21Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifications and as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the perfomance of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-Charge.$15011.22ÞRefixing on roof the dismantled pressed clay roofing tiles (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).10<1J011.23ÜRefixing on roof the dismantled pressed clay ridge tiles (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).18011.24Providing 200mm or equivalent square type UPVC gutter with necessary clamps, bolts, nuts and specials such as nozzles, sockets, stoppers, etc., including cost and conveyance of all materials and labour charges etc., complete as per the instructions of the dept. officers15011.25Providing and fixing in roof with necessary self tapping screws sandwich panel Trafford roofing sheet with total thickness of 50mm with polyurethane foam of Density 36 Kg/cum plus or minus 2 Kg/cum with thermal conductivity with of less than or equal to 22 MW/MK and form tensile strength (adhesion) at 80C Greater than or equal to 80Kpa and youngs modulus at 80C greater than or equal to 2500 Kpa sandwiched between two GI sheets. The external and internal sheet shall have thickness of 0.40mm and 0.30mm respectively. The external and internal sheet shall be JSW/TATA/Bhushan/LLoyds make having a minimum 150 GSM galvalume coating pre-painted with approved colour and shade by the Engineer in charge with an SMP coating of 18 microns over epoxy coats of 7 micronsA1f011.26üProviding and fixing false ceiling with PVC plain panel board of 7.5 mm or nearest thickness of approved quality in aluminium frame work with necessary edge/intermediate trims, clips, screws, etc. complete (aluminium framework shall be paid separately)17011.27 Providing and fixing false ceiling with PVC panel board of 7.5 mm or nearest thickness of approved wooden grain design & quality in aluminium frame work with necessary edge/intermediate trims, clips, screws, etc. complete (aluminium framework shall be paid separately)110c1v011.28YProviding and Fixing of Armstrong or equvalent Soft Fibre Acoustical Suspended Ceiling System with Optra (Microlook) EDGE TILES WITH ARMSTRONG 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 95 percentage, NRC 0.9 to 1.0, Light Reflectance 85percentage, Colour White, Fire Performance UK Class o Class 1 (BS 476 pt . 6 and 7) in module size of 600 x 600 x 15mm, suitable for Green Building application, with Recycled content of 66 percentage GW and 74 percentage RW 74 percentage. The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.00 Kgs/M2. The T Sections have a Galvanizing of 90 grams per m2. as per instruction of engineer in charge712 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)10-110912 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)10-130712 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)10-110912 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)10-130g12 mm cement plaster of mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.10-130J1W0}Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.1M0SFlush/ Ruled pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand)10YDistempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 gram/litre, of approved manufacturer, of required shade and colour, all complete, on new work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre1/0Ì1×0Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 gram/litre, of approved manufacturer, of required shade and colour, all complete, on old work (one or more coats) to give an even shade.1/0Ì1Ø0¿Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufac
猠湹桴瑥捩攠慮敭慰湩⁴景愠灰潲敶牢湡湡慭畮慦瑣牵潴朠癩湡攠敶桳摡湯渠睥眠牯㤀 爀ࠀ慐湩楴杮眠瑩睴牯洠牯潣瑡景猠湹桴瑥捩攠慮敭慰湩⁴景愠灰潲敶牢湡湡慭畮慦瑣牵景爠煥極敲潣潬牵漠敮⁷潷歲癯牥愠湵敤捲慯⁴景猠極慴汢桳摡楷桴漠摲湩牡⁹慰湩⁴景愠灰潲敶牢湡湡慭畮慦瑣牵潴朠癩湡攠敶桳摡190o10̈倀楡瑮湩楷桴漠敮漠潭敲挠慯獴漠祳瑮敨楴湥浡汥瀠楡瑮漠灡牰癯摥戠慲摮愠摮洠湡晵捡畴敲漠敲畱物摥挠汯畯潴朠癩湡攠敶桳摡湯漠摬眠牯190 1v̈倀楡瑮湩楷桴琠潷漠潭敲挠慯獴漠污浵湩畩慰湩⁴景愠灰潲敶牢湡湡慭畮慦瑣牵潴朠癩湡攠敶桳摡湯渠睥眠牯൫㈀ 樀瘀ࠀ慐湩楴杮眠瑩湯牯洠牯潣瑡景愠畬業楮浵瀠楡瑮漠灡牰癯摥戠慲摮愠摮洠湡晵捡畴敲琠楧敶愠癥湥猠慨敤漠汯潷歲120j1Ò̈䘀湩獩楨杮眠瑩灅硯⁹慰湩⁴琨潷漠潭敲挠慯獴 瑡愠汬氠捯瑡潩獮瀠敲慰敲湡灡汰敩獡瀠牥洠湡晵捡畴敲❲灳捥晩捩瑡潩獮椠据畬楤杮愠灰潲牰慩整瀠楲業杮挠慯ⱴ瀠敲慰慲楴湯漠畳晲捡ⱥ攠捴潣灭敬整湯猠整汥眠牯ཫᨀ 씀픀ࠀ楆楮桳湩楷桴䔠潰祸瀠楡瑮⠠睴牯洠牯潣瑡⥳愠⁴污潬慣楴湯牰灥牡摥愠摮愠灰楬摥愠数慭畮慦瑣牵牥猧猠数楣楦慣楴湯湩汣摵湩灡牰灯楲瑡牰浩湩潣瑡牰灥牡瑡潩景猠牵慦散瑥挠浯汰瑥ⱥ漠潣据敲整眠牯ཫᨀ 씀堀ࠀ牆湥档猠楰楲⁴潰楬桳湩湯渠睥眠牯獫⠠睴牯洠牯潣瑡⥳椠据畬楤杮愠挠慯⁴景眠潯楦汬牥1%0XȈ䘀敲据灳物瑩瀠汯獩楨杮漠汯潷歲漨敮漠潭敲挠慯獴 湩汣摵湩潣瑡漠潷摯映汩敬r␀ 眀ࠅ潐楬桳湩湩栠杩汧獯⽳慭瑴映湩獩敭慬業敮挠敬牡瀠汯獩湯眠潯潷歲椠敲畱物摥挠汯牯眯潯敤桳摡整瑸牵楷桴映汯潬楷杮瀠潲散獳椠桴敳畱湥散愠敤慴汩摥戠汥睯›ㄊ桔畳晲捡潴戠潰楬桳摥椠畲扢摥眠瑩慳摮瀠灡牥㠠⼰ㄠ〲渠愠摮琠敨楷桴猠湡慰数景ㄠ〶ㄯ〸渠獯㈊灁汰楹杮琠潷挠慯獴漠敳污牥眠瑩灳慲⁹畧湡污潬楷杮猠晵楦楣湥⁴牤楹杮琠浩潦猱⁴潣瑡愠摮㈠摮挠慯⁴獩愠汬睯摥琠牤⁹潦‸潴ㄠ′牨ਠ⸳传牤楹杮漠敳污牥挠慯ⱴ眠瑥爠扵楢杮眠瑩浥牥⁹汣瑯景映湩牥朠慲楤杮眠瑩浡汰慷整潴爠浥癯硥散獳猠慥敬慬敹湡慭敫琠敨猠牵慦散映牵桴牥猠潭瑯晡整桴獩眠瑥爠扵楢杮桴湥猠牵慦散椠灡汰敩楷桴猠数楣污朠慲敤洠汥浡湩楦汬牥潴映汩污桴浳污湡楢潨敬⽳牧潯敶瑥䘠汩敬潣瑡琠敢愠汬睯摥琠牤⁹潦‴潴㘠栠獲漠桷捩条楡楬桧⁴敷⁴畲扢湩獩搠湯桴獩猠牵慦散椠畦瑲敨污潬敷潴搠祲映牯ㄠ′牨ਠ⸴传桴獩猱⁴潣瑡漠敭慬業敮瀠汯獩獩愠灰楬摥眠瑩灳慲⁹畧獵湩敭慬業敮挠敬牡瀠汯獩湡敭慬業敮琠楨湮牥椠敲畱物摥瀠潲潰瑲潩吠楨猱⁴潣瑡椠污潬敷潴搠祲映牯㈠‴牨桴湥琠楨牤⁹畳晲捡獩愠慧湩映湩敷⁴畲扢摥猠潭瑯ⱨ眠楨档椠畦瑲敨污潬敷潴搠祲映牯ㄠ′牨吠敨映湩污洠汥浡湩潰楬桳椠灡汰敩楷桴挠浯牰獥潳牰獥畳敲猠牰祡朠湵甠楳杮洠汥浡湩汣慥潰楬桳愠摮洠汥浡湩桴湩敮業數湩爠煥極敲牰灯牯楴湯挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥椭桃牡敧䘨湩污挠慯⁴潴戠潤敮椠‱牯㈠氠祡牥楷桴畯⁴慧⁰景琠浩ഩ㤀 ㌀ࠀ敍慬業敮瀠汯獩楨杮漠潷摯眠牯漨敮漠潭敲挠慯⥴.ἀ 䈀ࠀ敌瑴牥湩楷桴戠慬正䨠灡湡瀠楡瑮漠灡牰癯摥戠慲摮愠摮洠湡晵捡畴敲1 0FȈ刀ⵥ敬瑴牥湩楷桴戠慬正䨠灡湡瀠楡瑮漠灡牰癯摥戠慲摮愠摮洠湡晵捡畴敲.␀ 氀ࠀ慐湩楴杮⠠湯牯洠牯潣瑡⥳眠瑩汢捡慊慰慰湩⁴景愠灰潲敶牢湡湡慭畮慦瑣牵潴朠癩湡攠敶桳摡130¬Ȉ䘀湩獩楨杮䘠潬牯楷桴漠敮漠潭敲挠慯獴漠牰浥畩汦潯畧牡䄨数⁸汦潯畧牡牯攠畱癩污湥⥴眠瑩楓楬潣敮愠摤瑩癩獥漠敲畱物摥猠慨敤愠数慭畮慦瑣牵牥猠数楣楦慣楴湯ᙳ㸀 가ࠀ楆楮桳湩汆潯獲眠瑩睴牯洠牯潣瑡景瀠敲業浵映潬牯朠慵摲⠠灁硥映潬牯朠慵摲漠煥極慶敬瑮 楷桴匠汩捩湯摡楤楴敶景爠煥極敲桳摡獡瀠牥洠湡晵捡畴敲灳捥晩捩瑡潩獮1>0ų؈刀灥楡獲琠汰獡整景琠楨正敮獳ㄠ′浭琠〲洠湩瀠瑡档獥漠牡慥㈠㔮猠敭整獲愠摮甠摮牥楷桴挠浥湥⁴潭瑲牡ㄠ㐺⠠‱散敭瑮㨠㐠映湩慳摮 湩汣摵湩畣瑴湩桴慰捴湩瀠潲数桳灡ⱥ爠歡湩畯⁴潪湩獴愠摮瀠敲慰楲杮愠摮瀠慬瑳牥湩桴畳晲捡景琠敨眠污獬挠浯汰瑥ⱥ椠据畬楤杮搠獩潰慳景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲1.0n1q010ŵ؈刀灥楡獲琠汰獡整景琠楨正敮獳ㄠ′浭琠〲洠湩瀠瑡档獥漠牡慥㈠㔮猠敭整獲愠摮甠摮牥楷桴挠浥湥⁴潭瑲牡ㄠ㐺⠠‱散敭瑮㨠㐠挠慯獲慳摮 湩汣摵湩畣瑴湩桴慰捴湩瀠潲数桳灡ⱥ爠歡湩畯⁴潪湩獴愠摮瀠敲慰楲杮愠摮瀠慬瑳牥湩桴畳晲捡景琠敨眠污獬挠浯汰瑥ⱥ椠据畬楤杮搠獩潰慳景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲1.0n1q010ȦĈ䘀硩湩档睯桫瑡湩攠楸瑳湩灯湥湩湩汣摵湩浥敢摤湩档睯桫瑡湩映潬牯牯眠污獬挠瑵楴杮洠獡湯祲映牯栠汯晤獡獴浥敢摤湩潨摬映獡獴椠散敭瑮挠湯牣瑥汢捯獫漠楳敺ㄠ‵⁸〱砠ㄠ‰浣眠瑩散敭瑮挠湯牣瑥㨱㨳‶ㄨ挠浥湥⁴›″潣牡敳猠湡›‶牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩⥥慰湩楴杮琠潷挠慯獴漠灡牰癯摥眠潯牰獥牥慶楴敶琠楳敤景挠潨歷慨獴愠摮洠歡湩潧摯琠敨搠浡条獥琠慷汬湡汦潯獲愠敲畱物摥挠浯汰瑥ⱥ椠据畬楤杮搠獩潰慳景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲䐠潯档睯桫瑡ᡳ㐱㈮ㄮȨĈ䘀硩湩档睯桫瑡湩攠楸瑳湩灯湥湩湩汣摵湩浥敢摤湩档睯桫瑡湩映潬牯牯眠污獬挠瑵楴杮洠獡湯祲映牯栠汯晤獡獴浥敢摤湩潨摬映獡獴椠散敭瑮挠湯牣瑥汢捯獫漠楳敺ㄠ‵⁸〱砠ㄠ‰浣眠瑩散敭瑮挠湯牣瑥㨱㨳‶ㄨ挠浥湥⁴›″潣牡敳猠湡›‶牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩⥥慰湩楴杮琠潷挠慯獴漠灡牰癯摥眠潯牰獥牥慶楴敶琠楳敤景挠潨歷慨獴愠摮洠歡湩潧摯琠敨搠浡条獥琠慷汬湡汦潯獲愠敲畱物摥挠浯汰瑥ⱥ椠据畬楤杮搠獩潰慳景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲圠湩潤⁷档睯桫瑡ᡳ㐱㈮㈮ȳĈ䘀硩湩档睯桫瑡湩攠楸瑳湩灯湥湩湩汣摵湩浥敢摤湩档睯桫瑡湩映潬牯牯眠污獬挠瑵楴杮洠獡湯祲映牯栠汯晤獡獴浥敢摤湩潨摬映獡獴椠散敭瑮挠湯牣瑥汢捯獫漠楳敺ㄠ‵⁸〱砠ㄠ‰浣眠瑩散敭瑮挠湯牣瑥㨱㨳‶ㄨ挠浥湥⁴›″潣牡敳猠湡›‶牧摡摥猠潴敮愠杧敲慧整㈠‰浭渠浯湩污猠穩⥥慰湩楴杮琠潷挠慯獴漠灡牰癯摥眠潯牰獥牥慶楴敶琠楳敤景挠潨歷慨獴愠摮洠歡湩潧摯琠敨搠浡条獥琠慷汬湡汦潯獲愠敲畱物摥挠浯汰瑥ⱥ椠据畬楤杮搠獩潰慳景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲䌠敬敲瑳牯⁹楷摮睯挠潨歷慨獴Ș1⸴⸲ำࠁ楆楸杮挠潨歷慨⁴湩攠楸瑳湩灯湥湩湩戠楲正 䍒⁃慷汬眠瑩慤桳映獡整敮獲䌯敨業慣慦瑳湥牥景愠灰潲牰慩整猠穩㌨渠獯漠慥档瘠牥楴慣敭扭牥漠潤牯挠潨歷慨⁴湡′潮湯攠捡敶瑲捩污洠浥敢景眠湩潤⁷档睯桫瑡⥳湩汣摵湩潃瑳漠慤桳映獡整敮獲 档浥捩污映獡整敮10ŝȈ䴀歡湩桴灯湥湩湩戠楲正洠獡湯祲映牯搠潯⽲眠湩潤⽷挠敬敲瑳牯⁹楷摮睯湩汣摵湩楤浳湡汴湩湩映潬牯漠慷汬祢挠瑵楴杮洠獡湯祲愠摮洠歡湩潧摯琠敨搠浡条獥琠慷汬ⱳ映潬牯湩湡慪扭潣灭敬整潴洠瑡档攠楸瑳湩畳晲捡⽩楤灳獯污漠畭扬⽡爠扵楢桳琠桴敮牡獥⁴畭楮楣慰畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲1#0®刀湥睥湩汧獡慰敮ⱳ眠瑩異瑴⁹湡慮汩桷牥癥牥渠捥獥慳祲椠据畬楤杮爠捡楫杮漠瑵琠敨漠摬瀠瑵祴›汆慯⁴汧獡慰敮景渠浯湩污琠楨正敮獳㐠洠眨楥桧⁴潮⁴敬獳琠慨〱杫猯浱ة㐱㔮ㄮ}Ȉ刀湥睥湩汦慯⁴汧獡慰敮景渠浯湩污琠楨正敮獳㐠洠眨楥桧⁴潮⁴敬獳琠慨〱杫猯浱Ⱙ眠瑩潷摯湥映汩敬獴眠敨敲敶敮散獳牡10zȈ刀湥睥湩汦慯⁴汧獡慰敮景渠浯湩污琠楨正敮獳㐠洠眨楥桧⁴潮⁴敬獳琠慨〱杫猯浱 湡敲楦楸杮攠楸瑳湩潷摯湥映汩敬獴.ᨀ ∀ࠁ敒敮楷杮眠潯敤慢瑴湥湩爠潯獦甠楳杮匠污眠潯慢瑴湥ⱳ椠据畬楤杮洠歡湩潧摯琠敨栠汯獥椠慷汬愠摮瀠楡瑮湩楷桴漠汩琠灹潷摯瀠敲敳癲瑡癩景愠灰潲敶牢湡湡慭畮慦瑣牵潣灭敬整湩汣摵湩敲潭慶景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲1 0ʼnȈ刀湥睥湩潷摯湥戠慥獭⠠潮⁴硥散摥湩⸴〰洠瑥敲湩氠湥瑧⥨椠潲景獵湩潈汬捯潷摯戠慥獭湩汣摵湩慭楫杮朠潯桴潨敬湩眠污獬愠摮瀠楡瑮湩楷桴漠汩琠灹潷摯瀠敲敳癲瑡癩景愠灰潲敶牢湡湡慭畮慦瑣牵潣灭敬整湩汣摵湩敲潭慶景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲10ÏЈ刀歡湩畯⁴潪湩獴椠楬敭漠散敭瑮洠牯慴湡牰灥牡湩桴畳晲捡潦敲瀭楯瑮湩牯爠灥慬瑳牥湩Ⱨ椠据畬楤杮搠獩潰慳景爠扵楢桳琠桴畤灭湩牧畯摮污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湩䌭慨杲10E1d0Ȉ倀潲楶楤杮樠楯瑳欨牡楲獥 湩汣摵湩潨獩楴杮楦楸杮椠潰楳楴湯愠摮愠灰祬湩潷摯瀠敲敳癲瑡癩湯甠敮灸獯摥猠牵慦散攠捴潣灭敬整d
with Hollock wood.10öProviding and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.1.0PRepair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.1,0Á1÷0>Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)1+0 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm10ÎCleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (iv) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.140ÉDisconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.1=0}Providing & fixing Indian type (Orissa pattern) White vitreous china water closet squatting pan of size 580x440 mm along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in-charge. 1.0E1Q01²0åCutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge.1 014051N013.23Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.1013.24oHacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.1013.25Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.1'0N1p013.26¹Repair to existing RCC structure including replacing corroded steel bars and fixing new additional TMT steel bars using welding, drilling, fixing to existing structure etc. as required.+1q0ÍDemolishing cement concrete of 1:3:6 or richer mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.130ÍDemolishing cement concrete of 1:4:8 or leaner mix (i/c equivalent design mix) manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.120¾Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.ÕDemolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.10±Removing mortar from bricks dismantled from brick work in cement mortar and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured)10ßDemolishing stone rubble masonry in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.1 0ÇDismantling doors, windows and clerestory windows (steel or wood) shutters of area 3 sq. metres and below, including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead.110S1i0ÄDismantling doors, windows and clerestory windows (steel or wood) shutters of area beyond 3 sq. metres, including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead.110N1f0Taking out doors, windows and clerestory window shutters (steel or wood) of area 3 sq. metres and below, including stacking within 50 metres lead.180Q1g0Taking out doors, windows and clerestory window shutters (steel or wood) of area beyond 3 sq. metres, including stacking within 50 metres lead.180L1d0ÏDismantling wood work of sectional area 40 square centimetres and above in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead.10ËDismantling wood work of sectional area below 40 square centimetres in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead.10Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flatsg115.17.2Dismantling tile work using tiles of thickness 10 mm to 25 mm in floors and roofs, laid in cement mortar, including stacking material within 50 metres lead.10Dismantling G.S. Sheet roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead.10Dismantling Asbestos Cement sheet roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead.1)0§Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.10ÿDismantling G.I. pipes above 40 mm nominal bore (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge.10ºDismantling of flushing cistern of all types (C.I /PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.10¥Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.1$0åDismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.1(0öDemolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars.1014.23²Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge.1 014.24,Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.10zFencing with G.I. barbed wire, with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used.10SProviding and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade130ä17016.70.27Taking out existing CC interlocking paver blocks from footpath/central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.100hLaying old cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost)14015.06¯Providing and fixing White Vitreous china Orissa pattern water closet squatting pan of size 580x440 mm with integral type foot rests with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.*1S01ó01"0=1[0Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with ISI marked white solid plastic seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.F1\01Ö0ù10!1?0uProviding and fixing Orissa pattern white vitreous china water closet squatting pan (Indian type) of size 580x440 mm.1S0iProviding and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan.91d0ËProviding and fixing white coloured P.V.C. low level flushing cistern of 10 litre capacity with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.$1[0[Providing and fixing white solid plastic seat with lid for pedestal type W.C. pan complete.160Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.H1a0Providing and fixing flat back white vitreous china wash basin of size 630x450mm including making all connections but excluding the cost of fittings.1041>0G1P0Providing and fixing flat back white vitreous china wash basin of size 550x400mm including making all connections but excluding the cost of fittings.1041>0G1P0Providing and fixing flat back white vitreous china wash basin of size 450x300mm including making all connections but excluding the cost of fittings.1041>0G1P0Providing and fixing Surgeon type white vitreous china wash basin of size 660x460mm including making all connections but excluding the cost of fittings.1!071A0J1S0Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings : Size 450x300x150 mmx117.27.1Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings : Size 600x450x200 mmw117.27.2ÉProviding and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard boardground fixed to wooden cleats with C.P. brass screws and washers complete.130ÊProviding and fixing mirror of superior glass (of approved quality) and of rectangular shape and 453x357 mm size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.10a1k0ËProviding and fixing mirror of superior glass (of approved quality) and of rectangular shape and 1500x450 mm size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.10a1l0ªProviding and fixing PTMT Waste Coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms for wash basin and sink, of approved quality and colour.120ªProviding and fixing PTMT Waste Coupling 38 mm dia of 83 mm length and 77mm breadth weighing not less than 60 gms for wash basin and sink, of approved quality and colour.120Providing and fixing PTMT Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms, for Wash basin and sink.1%0&1*0 Providing and fixing PTMT Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms, for Wash basin and sink.1+0îProviding and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.1/0ßProviding and fixing PTMT towel ring trapezoidal shape 215 mm long,200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour,weighing not less than 88 gms.1$0Providing and fixing 450 mm long PTMT towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms, complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.100Providing and fixing 600 mm long PTMT towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not less than 190 gms, complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.10016.25þProviding and fixing UPVC SWR soil, waste and vent pipes conforming to IS:13592 Type-B, jointing with solvent cement including cutting holes in walls and floors wherever required and making good the same as directed by Engineer-in-Charge : 110mm diameter16.26ýProviding and fixing UPVC SWR soil, waste and vent pipes conforming to IS:13592 Type-B, jointing with solvent cement including cutting holes in walls and floors wherever required and making good the same as directed by Engineer-in-Charge : 90mm diameter16.27þ Providing and fixing UPVC SWR soil, waste and vent pipes conforming to IS:13592 Type-B, jointing with solvent cement including cutting holes in walls and floors wherever required and making good the same as directed by Engineer-in-Charge: 75mm diameter16.28üProviding and fixing UPVC SWR soil, waste and vent pipes conforming to IS:13592 Type-B, jointing with solvent cement including cutting holes in walls and floors wherever required and making good the same as directed by Engineer-in-Charge: 63mm diameter16.29üProviding and fixing UPVC SWR soil, waste and vent pipes conforming to IS:13592 Type-B, jointing with solvent cement including cutting holes in walls and floors wherever required and making good the same as directed by Engineer-in-Charge: 50mm diameter16.30üProviding and fixing UPVC SWR soil, waste and vent pipes conforming to IS:13592 Type-B, jointing with solvent cement including cutting holes in walls and floors wherever required and making good the same as directed by Engineer-in-Charge: 40mm diameter16.31Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC tee with access door : 110mm16.32Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC tee with access door : 90mm16.33Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC tee with access door : 75mm16.34Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC tee with access door : 63mm16.35Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC tee with access door : 50mm16.36Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC tee with access door : 40mm16.37/Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC bend of required degree with access door : 110mm16.38.Providing and fixing unplasticized Rigid PVC moulded fittings/accessories conforming to IS:14735 for soil, waste and vent pipes conforming to IS:13592 Type B including jointing with solvent cement, etc. complete as directed by the Engineer-in-Charge UPVC bend of required degree with access door : 90mm16.39.Providing and fixing unplasticized Rigid PVC mo
( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20rnm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 1/0o10ÂConstructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design .with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 100o10 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.71V0PProviding and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.!1]0hProviding and fixing C.P. brass bib cock of approved quality conforming to IS:8931 of 15 mm nominal bore1(0Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms of 15 mm nominal bore120Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms of 15 mm nominal bore120Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 of 15 mm nominal bore150Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 of 15mm nominal bore1+0Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.100Providing and fixing PTMT bib cock 15mm nominal bore, 86 mm long, weighing not less than 88 gms, of approved quality and colour.1"061@0Providing and fixing PTMT bib cock 15 mm nominal bore, 165 mm long, weighing not less than 110 gms, of approved quality and colour.1"071B0j2-in-1 PTMT bib cock of 15mm nominal bore having two outlets controlled by two independent control handles10PTMT bib cock of 15mm nominal bore having outlet compatible with inlet connection pipes used for manual & automatic washing machines1 011@0a1Providing and fixing PTMT pillar cock 15 mm nominal bore, 107 mm long, weighing not less than 110 gms, of approved quality and colour.1%0:1E0Providing and fixing PTMT push cock 15 mm nominal bore, 80 mm long, weighing not less than 46 gms, of approved quality and colour.1$081B0´Providing and fixing 150 mm nominal size square type PTMT grating with openable circular lid of 100 mm diameter (of the inner hinged round grating), of approved quality and colour.1051A0G1f0ÑProviding and fixing PTMT Ball cock 20 mm nominal bore of approved quality, colour and make complete with Epoxy coated 120 mm long aluminium rod with L.P./ H.P.H.D. plastic ball weighing not less than 198 gms.1)01±017.49ÑProviding and fixing PTMT Ball cock 25 mm nominal bore of approved quality, colour and make complete with Epoxy coated 152 mm long aluminium rod with L.P./ H.P.H.D. plastic ball weighing not less than 440 gms.1)01±017.50ÑProviding and fixing PTMT Ball cock 40 mm nominal bore of approved quality, colour and make complete with Epoxy coated 206 mm long aluminium rod with L.P./ H.P.H.D. plastic ball weighing not less than 690 gms.1)01±017.51[Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms1)017.52^Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms1+017.53Providing and fixing unplasticised P.V.C. connection pipe of 15 mm nominal bore and 30cm length with PTMT Nuts, collar and bush of approved quality and colour.190`1017.54Providing and fixing unplasticised P.V.C. connection pipe of 15 mm nominal bore and 45cm length with PTMT Nuts, collar and bush of approved quality and colour.19017.55Providing and fixing PTMT extension nipple of 25mm nominal bore, weighing not less than 62 gms, for water tank pipe, fittings of approved quality and colour.1+017.56yCutting holes up to 30x30 cm in walls with common burnt clay F.P.S. (non modular) bricks, including making good the same.1%017.57,Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.17017.58Providing and fixing Rectangular type (100 mm nominal size) Stainless Steel grating with openable rectangular lid, of approved quality and colour.<1S017.59XProviding and fixing C.P. brass Health Faucet of approved quality conforming to IS:8931.1-017.60ÅProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall : 20mm nominal dia pipes17.61ÅProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall : 25mm nominal dia pipes17.62ÅProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall : 32mm nominal dia pipes17.63ÅProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall : 40mm nominal dia pipes17.64ÅProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall : 50mm nominal dia pipes17.65ÅProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 10kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Exposed on wall : 63mm nominal dia pipes17.66üProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 15kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls, etc. 20mm nominal dia pipes17.67üProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 15kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls, etc. 25mm nominal dia pipes17.68üProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of 15kgf/cm2 pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124), including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls, etc. 32mm nominal dia pipes17.69ºProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating : 25mm nominal dia pipes17.70ºProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating : 32mm nominal dia pipes17.71ºProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating : 40mm nominal dia pipes17.72ºProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating : 50mm nominal dia pipes17.73ºProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating : 63mm nominal dia pipes17.74ºProviding and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating : 90mm nominal dia pipes17.75¸Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 10kgf/cm2 Pressure rating110mm nominal dia pipes17.76¼Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 12.5kgf/cm2 Pressure rating : 63mm nominal dia pipes17.77¼Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 12.5kgf/cm2 Pressure rating : 90mm nominal dia pipes17.78½Providing and fixing Unplasticized Polyvinyl Chloride (UPVC) pipes of specified pressure rating for domestic water supply, conforming to IS:4985 including all UPVC plain & brass threaded fittings(as per IS:7834/IS:10124). This includes jointing of pipes & fittings with solvent cement, testing of joints, trenching, refilling, complete as per direction of Engineer in Charge. External work : 12.5kgf/cm2 Pressure rating : 110mm nominal dia pipes17.79ÄProviding and fixing rigid UPVC pipes of at least 4kgf/cm2 rating as per IS:4985, complete with fittings such as reducers, couplings, adaptors, clamps, etc. including cutting and making good the walls and ceiling for waste pipes, bath wastes, overflow, kitchen equipment, waste connections and condensate drainage including cutting of masonry/RCC walls as required and making good the same as directed by the Engineer-in-Charge : 63mm nominal dia pipes17.80ÄProviding and fixing rigid UPVC pipes of at least 4kgf/cm2 rating as per IS:4985, complete with fittings such as reducers, couplings, adaptors, clamps, etc. including cutting and making good the walls and ceiling for waste pipes, bath wastes, overflow, kitchen equipment, waste connections and condensate drainage including cutting of masonry/RCC walls as required and making good the same as directed by the Engineer-in-Charge : 50mm nominal dia pipes17.81ÄProviding and fixing rigid UPVC pipes of at least 4kgf/cm2 rating as per IS:4985, complete with fittings such as reducers, couplings, adaptors, clamps, etc. including cutting and making good the walls and ceiling for waste pipes, bath wastes, overflow, kitchen equipment, waste connections and condensate drainage including cutting of masonry/RCC walls as required and making good the same as directed by the Engineer-in-Charge : 20mm nominal dia pipes17.82Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 20mm UPVC Ball Valve (12.5kg/cm2)17.83Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 25mm UPVC Ball Valve (16kg/cm2)17.84Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 32mm UPVC Ball Valve (16kg/cm2)17.85Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement): 40mm UPVC Ball Valve (6kg/cm2)17.86Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 50mm UPVC Ball Valve (6kg/cm2)17.87Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 63mm UPVC Ball Valve (6kg/cm2)17.88Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 90mm UPVC Ball Valve (10kg/cm2)17.89Providing and fixing UPVC ball valve of approved quality (screwed end/pasted end as per site requirement) : 110mm UPVC Ball Valve (10kg/cm2)»Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete, for pipes 100 to 250 mm diameter1(0dConstructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1. cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc, complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5é1ó0tConstructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1. cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc, complete as per standard design: Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5é1ó0xConstructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1. cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete
敲敳癲潩Ⱳ猠睥条…慷整牴慥浴湥⁴汰湡ⱴ琠湵敮獬⼠猠扵慷⁹湡牢摩敧搠捥瑥牰灥牡摥戠⁹業楸杮椠桴慲楴景㔠㨠㈠⠠‵慰瑲湩整牧污挠祲瑳污楬敮猠畬牲⁹›′慰瑲慷整⥲映牯瘠牥楴慣畳晲捡獥愠摮㌠㨠ㄠ⠠″慰瑲湩整牧污挠祲瑳污楬敮猠畬牲⁹›‱慰瑲眠瑡牥 潦潨楲潺瑮污猠牵慦散湡灡汰楹杮琠敨猠浡牦浯渠来瑡癩椨瑮牥慮⥬猠摩楷桴琠敨栠汥⁰景猠湹桴瑥捩映扩牥戠畲桳桔慭整楲污猠慨汬洠敥⁴桴敲畱物浥湥獴愠灳捥晩敩湩䄠䥃㈭㈱㌭ⵒ〲〱椠攮戠⁹敲畤楣杮瀠牥敭扡汩瑩⁹景挠湯牣瑥祢洠牯桴湡㤠┰挠浯慰敲楷桴挠湯牴汯挠湯牣瑥獡瀠牥䐠义ㄠ㐰‸湡敲楳瑳湡⁴潴ㄠ‶慢票牤獯慴楴牰獥畳敲漠敮慧楴敶猠摩吠敨挠祲瑳污楬敮猠畬牲⁹桳污敢挠灡扡敬漠敳晬栭慥楬杮漠牣捡獫甠⁰潴愠眠摩桴漠⸰〵浭桔潷歲猠慨汬戠慣牲敩畯⁴污潣灭敬整愠数灳捥晩捩瑡潩湡桴楤敲瑣潩景琠敨攠杮湩敥湩挭慨杲吠敨瀠潲畤瑣瀠牥潦浲湡散猠慨汬挠牡祲朠慵慲瑮敥映牯ㄠ‰敹牡条楡獮⁴湡⁹敬歡条120ǿ1ȗ0Н1ч0ɑȈ倀潲楶楤杮☠䄠灰祬湩潰祬敭潭楤楦摥汦硥扩敬挠浥湥慴楴畯敮慧楴敶猠摩慷整灲潲景湩潣瑡湩楷桴攠慬瑳捩眠瑡牥牰潯楦杮瀠汯浹牥湯椠瑮牥潩慷汬瀠慬瑳牥猠牵慦散椠桴敲潣瑡ㅀ⸴㔳欠ㄯ‰煳漠敮挠慯⁴景猠汥牰浩湩景挠浥湥慴楴畯慷整灲潲景湩潰祬敭⡲楤畬楴湯眠瑩慷整湩琠敨爠瑡潩漠㨱⤱愠摮琠潷挠慯獴漠散敭瑮瑡潩獵眠瑡牥牰潯楦杮瀠汯浹牥⠠楤畬楴湯眠瑩慷整湩琠敨爠瑡潩漠㨳‱ 晡整捳慲灰湩湡牰灯牥祬挠敬湡湩桴畳晲捡潴爠浥癯牰ⵥ硥獩楴杮瀠楡瑮映汩…潬獯慰瑲捩敬楴汬瀠慬瑳牥椠楶楳汢ⱥ挠浯汰瑥湩愠汬爠獥数瑣愠数桴楤敲瑣潩景䔠杮湩敥湩䌭慨杲1`0ƥȈ倀潲楶楤杮愠摮映硩湩慦瑣牯⁹慭敤瀠敲慣瑳删䍃瀠牥潦慲整牤楡潣敶獲慨楶杮挠湯牣瑥景猠牴湥瑧潮⁴敬獳琠慨ⵍ㔲景猠穩〱〰㑸〵㕸‰浭敲湩潦捲摥眠瑩‸浭搠慩映畯潮潬杮瑩摵湩污☠㤠渠獯挠潲獳猠捥楴湯污吠䴮吮潨灯戠牡ⱳ椠据畬楤杮瀠潲楶楤杮㔠‰浭搠慩瀠牥潦慲楴湯⁀〱‰潴ㄠ㔲洠⽣Ᵽ椠据畬楤杮瀠潲楶楤杮攠杤楢摮湩楷桴䴠匮汦瑡景猠穩〵洠⁸⸱‶浭挠浯汰瑥ⱥ愠汬愠数楤敲瑣潩景䔠杮湩敥湩挭慨杲"1E0ͤЈ䌀敬湡湩畳晲捡獥愠摮爠浥癯湩楤瑲畤瑳楢摲搠潲灰湩Ⱨ朠敲獡ⱥ漠汩污慧ⱥ映湵畧ⱳ洠湯敫⁹敢瑡ⱳ瘠来瑥扡敬朠潲瑷瑥湩汣摵湩牰癯摩湩Ⱨ愠灰祬湩湡慷桳湩桴畳晲捡楷桴挠敨業慣汣慥楮杮愠敧瑮愠灡牰癯摥戠⁹湅楧敮牥椭档牡敧景愠灰潲敶牢湡湡慭畮慦瑣牵牥楷桴琠敨栠汥⁰景爠煥極敲捳畲扢牥湡污潳挠敬湡湩楷桴洠捡楨敮漠数慲整慷整敪⁴業數楷桴搠獥物摥焠慵瑮瑩⁹景映湩楳楬慣眠敨敲敶敲畱物摥楷桴畯⁴慣獵湩湡⁹捳慲捴楨杮 慤慭敧琠桴畳晲捡湡楦慮汬⁹慷桳湩桴畳晲捡楷桴挠敬湡眠瑡牥眠瑩桴敨灬漠牰獥畳敲樠瑥洠捡楨敮潣灭敬整椠污敲灳捥ⱴ椠据畬楤杮琠歡湩污牰捥畡楴湯潴猠晡来慵摲瘠湥楴慬潴獲楷摮睯ⱳ搠潯獲攠捴祢猠極慴汢潣敶楲杮猠獡琠癡楯湡⁹慤慭敧琠桴畢汩楤杮猯牴捵畴敲污獡瀠牥搠物捥楴湯漠湅楧敮牥湩挭慨杲吨敨爠瑡獩椠据畬楳敶漠污慭整楲污…慬潢牵湩潶癬摥攠捸灥⁴捳晡潦摬湩⥧.ሀ 䬀樀、뜀ࠄ牐癯摩湩湡畳灰祬湩灓湡牤汥䜠慬獳倠湡汥潣灭楲楳杮漠‶浭琠楨正栠慥⁴瑳敲杮桴湥摥洠湯汯瑩楨汦慯⁴汧獡景愠灰潲敶潣潬牵愠摮猠慨敤眠瑩敲汦捥楴敶猠景⁴潣瑡湩湯猠牵慦散⌠㈠漠灡牰癯摥挠汯畯湡桳摡潳愠潴洠瑡档琠敨挠汯畯湡桳摡景琠敨䤠啇湩琠敨瘠獩潩慰敮獬攠捴Ⱞ愠汬挠浯汰瑥潦桴敲畱物摥瀠牥潦浲湡散獡猠数楣楦摥獡瀠牥琠敨䄠捲楨整瑣牵污搠慲楷杮ⱳ愠数桴灡牰癯摥猠潨⁰牤睡湩獧獡猠数楣楦摥湡獡搠物捥整祢琠敨䔠杮湩敥椠桃牡敧潆慰浹湥ⱴ漠汮⁹桴捡畴污愠敲景朠慬獳漠慦散⌠ㄠ漠桴汧獡灳湡汥戨瑵攠捸畬楤杮琠敨愠敲景朠潲癯獥愠摮眠慥桴牥猠汩捩湯敳污湡⥴瀠潲楶敤湡楦數湩瀠獯瑩潩Ɱ猠慨汬戠敭獡牵摥椠煳⠠慐浹湥⁴潦暠硩湩景匠慰摮敲汇獡慐敮獬椠桴畣瑲楡汧穡湩獩椠据畬敤湩挠獯⁴景爠汥癥湥⁴瑉浥⤪⠮⥩䌠汯畯敲楴瑮摥映潬瑡朠慬獳㘠浭琠楨正猠扵瑳慲整眠瑩敲汦捥楴敶猠景⁴潣瑡湩湯映捡‣ⰲ栠癡湩牰灯牥楴獥愠楶楳汢楌桧⁴牴湡浳瑩慴据嘨呌 景㈠‵潴㌠‵Ⱕ䰠杩瑨爠晥敬瑣潩湩整湲污ㄠ‰潴ㄠ┵楬桧⁴敲汦捥楴湯攠瑸牥慮〱琠〲┠桳摡湩潣晥楦楣湥⁴〨㈮ⴵ〠㈮⤸愠摮唠瘠污敵漠⸳‰潴㌠㌮圠洯′⁋瑥吠敨瀠潲数瑲敩景瀠牥潦浲湡散朠慬獳猠慨汬戠敤楣敤祢琠捥湨捩污猠湡瑣潩楮杮愠瑵潨楲祴愠数桴楳整爠煥極敲敭瑮ᠮⴀ 瘀ࠀ牐癯摩湩湡楦楸杮挠湯散污摥栠湩敧漠灡牰癯摥焠慵楬祴映牯ㄠⴹ〲浭琠楨正搠潯楷桴猠慴湩敬獳猠整汥猠牣睥潣灭敬整㨠1$0ƼȈ䌀楨灰湩景甠獮畯摮眯慥潣据敲整洠瑡牥慩景㜠洵癡牥条桴捩湫獥牦浯猠慬獢敢浡ⱳ挠汯浵獮攠捴楷桴洠湡慵桃獩汥愠摮 牯戠⁹瑳湡慤摲瀠睯牥搠楲敶数捲獵楳湯琠灹牯漠灡牰癯摥洠歡湩汣摵湩慴数楲杮漠污摥敧ⱳ洠歡湩煳慵敲猠潨汵敤獲漠慣楶楴獥椠据畬楤杮挠敬湡湩桴硥潰敳潣据敲整猠牵慦散愠摮爠楥普牯散敭瑮眠瑩楷敲戠畲桳獥攠捴湡楤灳獯污漠敤牢獩映牯愠汬氠慥湡楬瑦污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湉䌭慨杲e䐀 밀ࠁ桃灩楰杮漠湵潳湵⽤敷歡挠湯牣瑥慭整楲污漠〵浭愠敶慲敧琠楨正敮獳映潲汳扡ⱳ戠慥獭潣畬湭瑥眠瑩慭畮污䌠楨敳湡⽤漠祢猠慴摮牡潰敷牤癩湥瀠牥畣獳潩祴数漠景愠灰潲敶慭敫椠据畬楤杮琠灡牥湩景愠汬攠杤獥慭楫杮猠畱牡桳畯摬牥景挠癡瑩敩湩汣摵湩汣慥楮杮琠敨攠灸獯摥挠湯牣瑥畳晲捡湡敲湩潦捲浥湥⁴楷桴眠物牢獵敨瑥愠摮搠獩潰慳景搠扥楲潦污敬摡愠摮氠晩獴愠汬挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥䤭桃牡敧1D0ƽȈ䌀楨灰湩景甠獮畯摮眯慥潣据敲整洠瑡牥慩景㈠‵浭愠敶慲敧琠楨正敮獳映潲汳扡ⱳ戠慥獭潣畬湭瑥眠瑩慭畮污䌠楨敳湡⽤漠祢猠慴摮牡潰敷牤癩湥瀠牥畣獳潩祴数漠景愠灰潲敶慭敫椠据畬楤杮琠灡牥湩景愠汬攠杤獥慭楫杮猠畱牡桳畯摬牥景挠癡瑩敩湩汣摵湩汣慥楮杮琠敨攠灸獯摥挠湯牣瑥畳晲捡湡敲湩潦捲浥湥⁴楷桴眠物牢獵敨瑥愠摮搠獩潰慳景搠扥楲潦污敬摡愠摮氠晩獴愠汬挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥䤭桃牡敧1E0ƉȈ䌀敬湡湩景爠楥普牯散敭瑮戠牡灵潴ㄠ′浭搠慩敭整牦浯爠獵⁴牦浯琠敨爠楥普牯楣杮戠牡潴朠癩瑩愠琠瑯污爠獵⁴牦敥猠整汥猠牵慦散戠⁹獵湩污慫楬敮挠敨業慣畲瑳爠浥癯牥漠灡牰癯摥洠歡楷桴瀠楡瑮戠畲桳愠摮爠浥癯湩潬獯慰瑲捩敬晡整㐲栠畯獲漠瑩灡汰捩瑡潩楷桴眠物牢獵湡桴牯畯桧祬眠獡楨杮眠瑩慷整湡污潬楷杮椠⁴潴搠祲污潣灭敬整愠数楤敲瑣潩景䔠杮湩敥湉䌭慨杲1*0ƊȈ䌀敬湡湩景爠楥普牯散敭瑮戠牡扡癯㈱洠楤浡瑥牥映潲畲瑳映潲桴敲湩潦捲湩慢獲琠楧敶椠⁴潴慴畲瑳映敲瑳敥畳晲捡祢甠楳杮愠歬污湩档浥捩污爠獵⁴敲潭敶景愠灰潲敶慭敫眠瑩慰湩⁴牢獵湡敲潭楶杮氠潯敳瀠牡楴汣獥愠瑦牥㈠‴潨牵景椠獴愠灰楬慣楴湯眠瑩楷敲戠畲桳愠摮琠潨潲杵汨⁹慷桳湩楷桴眠瑡牥愠摮愠汬睯湩瑩琠牤ⱹ愠汬挠浯汰瑥獡瀠牥搠物捥楴湯漠湅楧敮牥䤭桃牡敧.⨀ ⬀ࠁ牐癯摩湩Ⱨ洠硩湩湡灡汰楹杮匠剂倠汯浹牥⠠ㅀ┰漠散敭瑮眠楥桧⥴洠摯晩敩散敭瑮瑩潩獵戠湯潣瑡䀠㈠㈮欠散敭瑮瀠牥猠浱漠畳晲捡牡慥洠硩摥眠瑩灳捥晩敩牰灯牯楴湯漠灡牰癯摥瀠汯浹牥漠档灩数潰瑲潩景删䍃愠数灳捥晩捩瑡潩獮愠摮搠物捥楴湯漠湅楧敮牥䤭档牡敧挠浯汰瑥湩愠汬爠獥数瑣Ἦ⨀ 䌀戀 케ࠀ牐癯摩湩Ⱨ洠硩湩湡灡汰楹杮䔠潰祸戠湯楤杮愠桤獥癩慨楶杮挠癯牥条⸲〲猠浱欯景愠灰潲敶慭敫漠档灩数潰瑲潩景删䍃愠数灳捥晩捩瑡潩獮愠摮搠物捥楴湯漠湅楧敮牥䤭档牡敧挠浯汰瑥湩愠汬爠獥数瑣Ἦ㔀 ꠀࠂ牐癯摩湩Ⱨ洠硩湩湡灡汰楹杮匠剂瀠汯浹牥⠠景愠灰潲敶慭敫 潭楤楦摥䌠浥湥⁴潭瑲牡漠㈱洠癡牥条桴捩湫獥湩瀠潲潰瑲潩景ㄠ㐺⠠‱散敭瑮›‴牧摡摥挠慯獲慳摮眠瑩潰祬敭業楮畭┲戠⁹瑷景挠浥湥⁴獵摥 獡瀠牥猠数楣楦慣楴湯湡楤敲瑣潩獮漠湅楧敮牥椭档牡敧上瑯㩥䴠慥畳敲敭瑮愠摮瀠祡敭瑮›桔牰ⵥ敭獡牵浥湥⁴景琠楨正敮獳猠慨汬戠潤敮樠獵⁴晡整桴畳晲捡牰灥牡瑡潩獩挠浯汰瑥摥愠摮倠祡敭瑮甠摮牥琠楨瑩浥猠慨汬戠慭敤漠汮⁹晡整牰灯牥眠瑥挠牵湩慨敢湥搠湯湡畳晲捡慨敢湥猠瑡獩慦瑣牯汩⁹癥污慵整祢猠畯摮湩 慴灰湩楷桴愠戠畬瑮洠瑥污椠獮牴浵湥⁴湡⽤牯琠敨㜠洵楳敺挠扵牣獵楨杮猠牴湥瑧瑡琠敨攠摮漠㠲搠祡潴戠潮⁴敬獳琠慨〳丠匯浱㉭⸩1*0>1o0ƧȈ圀瑡牥瀠潲景湩牴慥浴湥⁴景删䍃猠湵桳摡楷桴娠捹獯汩匯歩条牡ⵤ㈷⽗楓潬慸䉗支畱癩污湥⁴牯慧潮楳慬敮猯汩硯湡ⵥ慢敳慷整牰潯楦杮匠汯瑵潩ㄨ氠瑩敲漠祚潣楳⽬煥極慶敬瑮☠㈠‰楬牴獥漠慷整瑳物敲楦獲⁴…′楬牴獥漠祚潣牰浩⽥煥極慶敬瑮愠摤摥愠摮猠楴牲摥⠠潴慴㌲氠瑩敲⥳ 楴汬椠⁴敭瑥桴慳畴慲楴湯氠癥汥愠摮琠獥楴杮愠数䥒䕌⁍牯戠⁹慷整牤灯整瑳椠桷捩慷整牤灯潤渠瑯愠獢牯畢⁴牤灯敲慭湩漠潲汬Y10Ȉ倀潲楶楤杮☠䄠灰祬湩敷瑡敨牰潯敳污湡⁴㔲浭ㅸ洰湯漠瑵牥樠楯瑮ⱳ漠灡牰癯摥洠歡潣普物業杮琠卉☠搠物捥整祢䔠杮湩敥湩挭慨杲1D0oviding and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made."150|10Providing and fixing factory made 30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)"1A0a1y0)Providing and fixing factory made 30 mm thick single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/ mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)"1A0a101Cutting or drilling on concrete, stones, rocks, tiles or similar type of materials using core cutting machine (wet cutting or dry cutting as per site conditions) of size 50 mm in diameter including clearing of debris and patching the surface wherever required as per the instruction of Engineer-in-charge.¥1»026.500.124.152Cutting or drilling on concrete, stones, rocks, tiles or similar type of materials using core cutting machine (wet cutting or dry cutting as per site conditions) of size 100 mm in diameter including clearing of debris and patching the surface wherever required as per the instruction of Engineer-in-charge.¥1¼026.500.224.162Cutting or drilling on concrete, stones, rocks, tiles or similar type of materials using core cutting machine (wet cutting or dry cutting as per site conditions) of size 150 mm in diameter including clearing of debris and patching the surface wherever required as per the instruction of Engineer-in-charge.¥1¼026.500.324.17]Providing, mixing and applying ready-to-use non-shrink high-performance repair microconcrete (of approved make) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 40 N/Sqmm2).: 12mm average thicknessG124.18]Providing, mixing and applying ready-to-use non-shrink high-performance repair microconcrete (of approved make) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 40 N/Sqmm2).: 25mm average thicknessG124.19]Providing, mixing and applying ready-to-use non-shrink high-performance repair microconcrete (of approved make) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 40 N/Sqmm2).: 50mm average thicknessG124.20nProviding, mixing and applying ready-to-use non-shrink high-performance repair microconcrete (of approved make) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 40 N/Sqmm2).: above 50mm, upto 100m average thicknessG124.21dProviding, mixing and applying ready-to-use non-shrink high-performance repair microconcrete (of approved make) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 40 N/Sqmm2).: above 100mm average thicknessG19HIRE CHARGES OF PLANTS & MACHINERY (Based on requirement)-Hydraulic Excavator (3D) with driver and fuel0020#Hydraulic Excavator of 1 cum bucketHour0051
metre
MORTAR
Cement mortar 1:4 (1 cement : 4 fine sand).
CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement concrete of grade 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), excluding the cost of centering and shuttering - All work up to plinth level.
Providing and laying in position cement concrete of grade 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources), excluding the cost of centering and shuttering - All work up to plinth level.
Centering and shuttering including strutting, propping etc. and removal of formwork for foundations, footings, bases for columns
Centering and shuttering including strutting, propping etc. and removal of formwork for retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Extra for laying concrete in or under foul positions.
REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of formwork for suspended floors, roofs, landings, balconies and access platforms
Centering and shuttering including strutting, propping etc. and removal of formwork for shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of formwork for lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of formwork for columns, pillars, piers, abutments, posts and struts
Centering and shuttering including strutting, propping etc. and removal of formwork for edges of slabs and breaks in floors and walls under 20 cm wide
metre
MASONRY WORK
Laterite masonry for foundation and basement upto plinth level including all cost of materials, labour charges etc. with available dismantled laterite stone, in cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with available brick in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand)
STONE WORK
Dry rubble masonry in foundation and plinth including levelling up upto plinth level with departmental stone (dismantled stone)
Random rubble masonry with available dismantled hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with cement mortar 1:6 (1 cement : 6 coarse sand)
CLADDING WORK
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
WOOD AND P. V. C. WORK
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
one set
metre
one set
metre
STEEL WORK
Welding by gas or electric plant including transportation of plant at site etc. complete.
FLOORING
ROOFING
metre
metre
Providing and fixing 6 mm thick multipurpose cement fiber board false ceiling tiles (High pressure steam cured, Type-B, Category-III as per IS: 14862 :2000) of approved texture of size 595x595 mm (Everest DuraCeil or equivalent) in true horizontal level, suspended on interlocking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main "T" runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross "T" of size 24x28 mm made out of 0.33 mm (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x28 mm made of 0.33 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to from grid of size 600x600 mm, resting on periphery walls/partitions on a Perimeter wall angle pre-coated steel of size 24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 6 mm thick multipurpose cement fiber board false ceiling tiles of approved texture in the grid, including, cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main "T" runners to be suspended from ceiling using aluminium slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85x30x0.8 mm, spaced at 1200 mm centre to centre along main "T". Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only cement fiber board false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The cement fiber board ceiling tile shall be non-combustible as per B.S. 476 part IV, have 100% humidity resistance and also having thermal conductivity <0.2 W/mK.
FINISHING
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
REPAIRS TO BUILDING
Dismantling and Demolishing
ROAD WORK
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of M-35 grade, 60mm thickness & of required size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per direction of Engineer-in-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of M-30 grade, 80mm thickness & of required size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per direction of Engineer-in-Charge.
SANITARY INSTALLATIONS
WATER SUPPLY
Providing and fixing unplasticised PVC connection pipe with brass unions of 30 cm length and 20 mm nominal bore
Providing and fixing unplasticised PVC connection pipe with brass unions of 45 cm length and 15 mm nominal bore
Providing and fixing unplasticised PVC connection pipe with brass unions of 45 cm length and 20 mm nominal bore
DRAINAGE
Extra for depth beyond 45 cm of brick masonry chamber of 455x610 mm size, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber of 500x700 mm size, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber of 600x850 mm size, with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
per litre
per litre
ALUMINIUM WORK
WATER PROOFING
Grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Grading roof for water proofing treatment with cement mortar 1:3 (1 cement : 3 coarse sand)
For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
RAIN WATER HARVESTING & TUBEWELLS
CONSERVATION OF HERITAGE BUILDINGS
STRUCTURAL GLAZING ALUMINIUM COMPOSITE PANEL
NEW TECHNOLOGIES AND MATERIALS
MANPOWER SUPPLY (Based on requirement)
Mason/Carpenter/Plumber/Fitter/Mistry/Nozzleman (Skilled)
Glazier/Painter/Mate/Bandhani/Bhisti (Semi-skilled)
Beldar/Helper/Coolie/Sewer man (Unskilled)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
BOQ_948143.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid